Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “log response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Safety and Efficacy of Stereotactic Ablative Radiation Therapy for Renal Cell Carcinoma Extracranial Metastases

Purpose: Renal cell carcinoma is refractory to conventional radiation therapy but responds to higher doses per fraction. However, the dosimetric data and clinical factors affecting local control (LC) are largely unknown. We aimed to evaluate the safety and efficacy of stereotactic ablative radiation therapy (SAbR) for extracranial renal cell carcinoma metastases. Methods and Materials: We reviewed 175 metastatic lesions from 84 patients treated with SAbR between 2005 and 2015. LC and toxicity after SAbR were assessed with Response Evaluation Criteria in Solid Tumors (RECIST) version 1.1 and Common Terminology Criteria for Adverse Events (CTCAE) version 4.0. Predictors of local failure were analyzed with χ{sup 2}, Kaplan-Meier, and log-rank tests. Results: In most cases (74%), SAbR was delivered with total doses of 40 to 60 Gy, 30 to 54 Gy, and 20 to 40 Gy in 5 fractions, 3 fractions, and a single fraction, respectively. The median biologically effective dose (BED) using the universal survival model was 134.5 Gy. The 1-year LC rate after SAbR was 91.2% (95% confidence interval, 84.9%-95.0%; median follow-up, 16.7 months). Local failures were associated with prior radiation therapy (hazard ratio [HR], 10.49; P<.0001), palliative-intent radiation therapy (HR, 4.63; P=.0189), spinal location (HR, 5.36; P=.0041), previous systemic therapy status (0-1 vs >1; HR, 3.52; P=.0217), and BED <115 Gy (HR, 3.45; P=.0254). Dose received by 99% of the target volume was the strongest dosimetric predictor for LC. Upon multivariate analysis, dose received by 99% of the target volume greater than BED of 98.7 Gy and systemic therapy status remained significant (HR, 0.12 and 3.64, with P=.0014 and P=.0472, respectively). Acute and late grade 3 toxicities attributed to SAbR were observed in 3 patients (1.7%) and 5 patients (2.9%), respectively. Conclusions: SAbR demonstrated excellent LC of metastatic renal cell carcinoma with a favorable safety profile when an adequate dose and coverage were applied. Multimodality treatment with surgery should be considered for reirradiation or vertebral metastasis. A higher radiation dose may be required in patients who received previous systemic therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reference-free structural variant detection in microbiomes via long-read co-assembly graphs

Motivation: The study of bacterial genome dynamics is vital for understanding the mechanisms underlying microbial adaptation, growth, and their impact on host phenotype. Structural variants (SVs), genomic alterations of 50 base pairs or more, play a pivotal role in driving evolutionary processes and maintaining genomic heterogeneity within bacterial populations. While SV detection in isolate genomes is relatively straightforward, metagenomes present broader challenges due to the absence of clear reference genomes and the presence of mixed strains. In response, our proposed method rhea, forgoes reference genomes and metagenome-assembled genomes (MAGs) by encompassing all metagenomic samples in a series (time or other metric) into a single co-assembly graph. The log fold change in graph coverage between successive samples is then calculated to call SVs that are thriving or declining. Results: We show rhea to outperform existing methods for SV and horizontal gene transfer (HGT) detection in two simulated mock metagenomes, particularly as the simulated reads diverge from reference genomes and an increase in strain diversity is incorporated. We additionally demonstrate use cases for rhea on series metagenomic data of environmental and fermented food microbiomes to detect specific sequence alterations between successive time and temperature samples, suggesting host advantage. Our approach leverages previous work in assembly graph structural and coverage patterns to provide versatility in studying SVs across diverse and poorly characterized microbial communities for more comprehensive insights into microbial gene flux.

59 BASIC BIOLOGICAL SCIENCES↗

Close-Call Action Log Form

"Close Call Action Log Form" ("CCALF") is the name of both a computer program and a Web-based service provided by the program for creating an enhanced database of close calls (in the colloquial sense of mishaps that were avoided by small margins) assigned to the Center Operations Directorate (COD) at Johnson Space Center. CCALF provides a single facility for on-line collaborative review of close calls. Through CCALF, managers can delegate responses to employees. CCALF utilizes a pre-existing e-mail system to notify managers that there are close calls to review, but eliminates the need for the prior practices of passing multiple e-mail messages around the COD, then collecting and consolidating them into final responses: CCALF now collects comments from all responders for incorporation into reports that it generates. Also, whereas it was previously necessary to manually calculate metrics (e.g., numbers of maintenance-work orders necessitated by close calls) for inclusion in the reports, CCALF now computes the metrics, summarizes them, and displays them in graphical form. The reports and all pertinent information used to generate the reports are logged, tracked, and retained by CCALF for historical purposes.

Spuler, Linda M.↗

Reverberation measurements of the inner radius of the dust torus in 17 Seyfert galaxies

We present the results of a dust reverberation survey for 17 nearby Seyfert 1 galaxies, which provides the largest homogeneous data collection for the radius of the innermost dust torus. A delayed response of the K-band light curve after the V-band light curve was found for all targets, and 49 measurements of lag times between the flux variation of the dust emission in the K band and that of the optical continuum emission in the V band were obtained by the cross-correlation function analysis and also by an alternative method for estimating the maximum likelihood lag. The lag times strongly correlated with the optical luminosity in the luminosity range of M{sub V} = –16 to –22 mag, and the regression analysis was performed to obtain the correlation log Δt (days) = –2.11 – 0.2 M{sub V} assuming Δt∝L {sup 0.5}, which was theoretically expected. We discuss the possible origins of the intrinsic scatter of the dust lag-luminosity correlation, which was estimated to be approximately 0.13 dex, and we find that the difference of internal extinction and delayed response of changes in lag times to the flux variations could have partly contributed to intrinsic scatter. However, we could not detect any systematic change of the correlation with the subclass of the Seyfert type or the Eddington ratio. Finally, we compare the dust reverberation radius with the near-infrared interferometric radius of the dust torus and the reverberation radius of broad Balmer emission lines. The interferometric radius in the K band was found to be systematically larger than the dust reverberation radius in the same band by the about a factor of two, which could be interpreted by the difference between the flux-weighted radius and response-weighted radius of the innermost dust torus. The reverberation radius of the broad Balmer emission lines was found to be systematically smaller than the dust reverberation radius by about a factor of four to five, which strongly supports the unified scheme of the Seyfert type of active galactic nuclei (AGNs). Moreover, we examined the radius-luminosity correlations for the hard X-ray (14-195 keV) and the [O IV] λ25.89 μm emission-line luminosities, which would be applicable for obscured AGNs.

79 ASTRONOMY AND ASTROPHYSICS↗

Operational Experience with the Frontier System in CMS

The Frontier framework is used in the CMS experiment at the LHC to deliver conditions data to processing clients worldwide, including calibration, alignment, and configuration information. Each central server at CERN, called a Frontier Launchpad, uses tomcat as a servlet container to establish the communication between clients and the central Oracle database. HTTP-proxy Squid servers, located close to clients, cache the responses to queries in order to provide high performance data access and to reduce the load on the central Oracle database. Each Frontier Launchpad also has its own reverse-proxy Squid for caching. The three central servers have been delivering about 5 million responses every day since the LHC startup, containing about 40 GB data in total, to more than one hundred Squid servers located worldwide, with an average response time on the order of 10 milliseconds. The Squid caches deployed worldwide process many more requests per day, over 700 million, and deliver over 40 TB of data. Several monitoring tools of the tomcat log files, the accesses of the Squids on the central Launchpad servers, and the availability of remote Squids have been developed to guarantee the performance of the service and make the system easily maintainable. Following a brief introduction of the Frontier framework, we describe the performance of this highly reliable and stable system, detail monitoring concerns and their deployment, and discuss the overall operational experience from the first two years of LHC data-taking.

Blumenfeld, Barry↗

Post-fire time series of sensor and geochemistry sample data from surface water, groundwater, precipitation, soil, and vegetation across Oak Creek watershed, Washington

This dataset supports a broader study examining wildfire impacts on hydrologic connectivity across 5 sites within the Oak Creek watershed and the resulting biogeochemical impacts. Stream sites were selected using the Advanced Terrestrial Simulator (ATS) hydrologic model to identify locations with varying groundwater contributions and hydrologic responses across different burn severity scenarios. The Retreat Fire burned from July 23 to August 2 in 2024, affecting the five study sites at varying burn severities. Each site is equipped with YSI EXO2 sondes logging sub-hourly throughout the year, and grab samples are collected approximately every six weeks. YSI sondes are used to measure temporally resolved proxies for groundwater inputs (specific conductivity) and organic matter (fluorescent dissolved organic matter; fDOM) along with basic water quality and depth. Grab samples of surface water, groundwater, and precipitation are analyzed for water stable isotopes and conductivity to understand endmembers for hydrologic mixing Grab samples of surface water, groundwater, soil water, and litter/vegetation/soil leachates are analyzed for organic matter composition measured by Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR-MS) to understand organic matter dynamics. Game camera photos are provided in a separate data package available at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3018598. Future versions of this dataset will include time series data from YSI EXO2 sondes (fDOM, dissolved oxygen, temperature, depth, specific conductance, turbidity, pH), BaroTROLL sensors (air temperature and barometric pressure), rain gauges (precipitation), and data from the soil and vegetation samples. Because this study is ongoing, this data package will be updated regularly to include newly collected data and the additional data types. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) a folder of field photos; (2) a folder of surface water sample data; (3) a folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data; (4) a data checks report; (5) file-level metadata; (6) data dictionary; (7) field metadata; (8) readme; (9) international generic sample number (IGSN) mapping file; and (10) field protocols. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) total dissolved nitrogen data and averages; (3) stable water isotopes and averages; (4) methods codes; (5) FTICR-MS methods; and (15) a subfolder of 9.4 Tesla (9.4T) FTICR-MS data. This folder contains the processed data and three subfolders, one containing the .xml files, one containing the water CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .xml, .d, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, .png, .mov, or .mp4.

Biogeochemistry↗

Low cost automated precise time measurement system

The Aerospace Guidance and Metrology Center (AGMC) has the responsibility for the dissemination of Precise Time and Time Interval (PTTI) to Air Force timing systems requiring microsecond time. In order to maintain traceability to the USNO Master Clock in Washington D.C., and accomplish efficient logging of time and frequency data on individual precision clocks, a simple automatic means of acquiring precise time has been devised. The Automatic Time Interval Measurement System (ATIMS) consists of a minicomputer (8K Memory), teletype terminal, electronic counter, Loran C receiver, time base generator and locally-manufactured relay matrix panel. During the measurement process, the computer controls the relay matrix which selects for comparison 13 atomic clocks against a reference clock and the reference versus Loran C. Through use of the system teletype, the operator is able to set the system clock (hours, minutes and seconds), examine and/or modify all clock data and constants, and set measurement intervals. This is done in a conversational manner. A logic flow diagram, system schematic, source listing and software components are included in the presentation.

Alpert, A.↗

A carbon nanotube based resettable sensor for measuring free chlorine in drinking water

Free chlorine from dissolved chlorine gas is widely used as a disinfectant for drinking water. The residual chlorine concentration has to be continuously monitored and accurately controlled in a certain range around 0.5–2 mg/l to ensure drinking water safety and quality. However, simple, reliable, and reagent free monitoring devices are currently not available. Here, we present a free chlorine sensor that uses oxidation of a phenyl-capped aniline tetramer (PCAT) to dope single wall carbon nanotubes (SWCNTs) and to change their resistance. The oxidation of PCAT by chlorine switches the PCAT-SWCNT system into a low resistance (p-doped) state which can be detected by probing it with a small voltage. The change in resistance is found to be proportional to the log-scale concentration of the free chlorine in the sample. The p-doping of the PCAT-SWCNT film then can be electrochemically reversed by polarizing it cathodically. This sensor not only shows good sensing response in the whole concentration range of free chlorine in drinking water but is also able to be electrochemically reset back many times without the use of any reagents. This simple sensor is ideally suited for measuring free chlorine in drinking water continuously.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Impact of Frictional Healing on Stick-Slip Recurrence Interval and Stress Drop: Implications for Earthquake Scaling: The impact of healing on stick-slip

We report that interseismic frictional healing is an essential process in the seismic cycle. Observations of both natural and laboratory earthquakes demonstrate that the magnitude of stress drop scales with the logarithm of recurrence time, which is a cornerstone of the rate and state friction (RSF) laws. However, the origin of this log linear behavior and short time “cutoff” for small recurrence intervals remains poorly understood. Here we use RSF laws to demonstrate that the back-projected time of null-healing intrinsically scales with the initial frictional state θ i . We explore this behavior and its implications for (1) the short-term cutoff time of frictional healing and (2) the connection between healing rates derived from stick-slip sliding versus slide-hold-slide tests. We use a novel, continuous solution of RSF for a one-dimensional spring-slider system with inertia. The numerical solution continuously traces frictional state evolution (and healing) and shows that stick-slip cutoff time also scales with frictional state at the conclusion of the dynamic slip process θ i (=D c /V peak ). This numerical investigation on the origins of stick-slip response is verified by comparing laboratory data for a range of peak slip velocities. Slower slip motions yield lesser magnitude of friction drop at a given time due to higher frictional state at the end of each slip event. In conclusion, our results provide insight on the origin of log linear stick-slip evolution and suggest an approach to estimating the critical slip distance on faults that exhibit gradual accelerations, such as for slow earthquakes.

58 GEOSCIENCES↗

Relationship of Thematic Mapper simulator data to leaf area index of temperate coniferous forests

Regional relationships between remote sensing data and the leaf area index (LAI) of coniferous forests were analyzed using data acquired by an Airborne Thematic Mapper. Eighteen coniferous forest stands with a range of projected leaf area index of 0.6-16.1 were sampled from an environmental gradient in moisture and temperature across west-central Oregon. Spectral radiance measurements to account for atmospheric effects were acquired above the canopies from a radiometer mounted on a helicopter. A strong positive relationship was observed between LAI of closed canopy forest stands and the ratio of near-infrared and red spectral bands. A linear regression based on LAI explained 83 percent of the variation in the ratio of the atmospherically corrected bands. A log-linear equation fit the asymptotic characteristic of the relationship better, explaining 91 percent of the variance. The positive relationship is explained by a strong asymptotic inverse relationship between LAI and red radiation and a relatively flat response between LAI and near-infrared radiation.

Peterson, David L.↗

Biodosimetry as a New Paradigm for Determination of Radiation Risks and Risk-Mitigation in Astronauts Exposed to Space Radiation

Predicting risk of cancer in astronauts exposed to space radiation is challenging partly because uncertainties of absorption of dose and the processing of dose-related damage at the cellular level degrade the confidence of predicting the expression of cancer. Cellular biodosimeters that simultaneously report: 1) the quantity of absorbed dose after exposure to ionizing radiation, 2) the quality of radiation delivering that dose, and 3) the macromolecular profiles related to malignant transformation in cells absorbing that dose would therefore be useful. An approach to such a multiparametric biodosimeter will be reported, This is the demonstration of two dose-responsive field-effects of enhanced protein-expression. In one case, expression of keratin 18 (K18) in cultures of human mammary epithelial cells (HMEC) irradiated with cesium-137 gamma-rays is enhanced following exposure of log phase cells to relatively low doses of 30 to 90 cGy. K18 has been reported by a marker for tumor staging and for apoptosis. In the second case, expression of connexin 43 (Cx43) is increased in irradiated stationary phase cultures of HMEC, indicating enhanced formation of gap junctions. Gap junctions have been reported to be involved in bystander effects following irradiation. It is a biodosimeter for assessing radiogenic damage. It is suggested further that such biomolecular dosimetry may introduce a new paradigm for assessing cancer risk and risk-mitigation in individuals, a requirement for managing radiation health in astronauts during extended missions in space. This new paradigm is built upon the statistical power provided by the use of functional genomics and proteomics represented in combined gene- and protein-expression assays.

Richmond, Robert↗

Spectral-density estimation with the Gaussian integral transform

The spectral-density operator $\hat{ρ}(ω) = δ(ω–\hat{H})$ plays a central role in linear response theory as its expectation value, the dynamical response function, can be used to compute scattering cross sections. In this work, we describe a near optimal quantum algorithm providing an approximation to the spectral density with energy resolution $\Delta$ and error $\epsilon$ using $O(\sqrt{\text{log}_2 (1/ε)[\text{log}_2 (1 / Δ) + \text{log}_2 (1/ε)]/ Δ)}$ operations. This is achieved without using expensive approximations to the time-evolution operator, but instead exploiting qubitization to implement an approximate Gaussian integral transform of the spectral density. Finally, we also describe appropriate error metrics to assess the quality of the spectral function approximations more generally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave bistatic reflectivity dependence on the moisture content and matric potential of bare soil

Results are presented of an experimental program to determine the functional dependence of the microwave reflectivity of nonvegetated soil surfaces upon volumetric soil moisture and matric potential. A combination evaporation-drainage field experiment was conducted on a bare Captina slit loam with reflectivity, soil moisture content, and matric potential monitored for extended time periods. Results show that for a restricted pressure range (approximately -0.05 to -0.75 bar) there is excellent linear correlation between the log of bistatic reflectivity and both volumetric moisture content and matric potential. Layering effects due to steep moisture content (and matric potential) gradients in the profile are demonstrated to have two distinct and significant effects on the reflectivity response. At near saturation of rough surfaces a very thin dry surface layer appears to modify the effective roughness. This leads to a saturation of reflectivity at high moisture contents. As the surface proceeds to dry further, deeper layers produce coherent interference patterns in the reflectivity response, particularly at the higher frequencies.

Waite, W. P.↗

Assessing the potential of composite confining systems for secure and long-term CO 2 retention in geosequestration

A potential geologic target for CO 2 storage should ensure secure containment of injected CO 2 . Traditionally, this objective has been achieved by targeting reservoirs with overlying seals-regionally extensive, low permeability units that have been proven capable of retaining buoyant fluid accumulations over geologic time. However, considering that the amount of CO 2 is limited by a decadal injection period, vertical migration of CO 2 can be effectively halted by a composite system of discontinuous shale/silt/mudstone barriers in bedded sedimentary rocks. Here, we studied the impact of depositional architectures in a composite confining system on CO 2 migration and confinement at reservoir scale. We stochastically generated lithologically heterogeneous reservoir models containing discontinuous barriers consistent with statistical distributions of net-sand-to-gross-shale ratio (NTG) and horizontal correlation lengths derived from well log data and observations of producing hydrocarbon fields in Southern Louisiana. We then performed an extensive suite of reservoir simulations of CO 2 injection and post-injection to evaluate the sensitivity of CO 2 plume migration and pressure response of the composite system to a series of geologic and fluid parameters including the lateral continuity of barriers, NTG, permeability anisotropy within the sand body, and capillary pressure contrast between the sand and shale facies. The results indicate that lateral continuity of barriers and NTG are the dominant controls on CO 2 plume geometry and pressure build-up in the reservoir, while the impact of NTG is particularly pronounced. The significance of intraformational barriers becomes apparent as they facilitate the local capillary trapping of CO 2 . Those barriers improve the pore space occupancy by promoting a more dispersed shape of the plume and ultimately retard the buoyancy-driven upward migration of the plume post injection.

58 GEOSCIENCES↗

Determining CDOM Absorption Spectra in Diverse Aquatic Environments Using a Multiple Pathlength, Liquid Core Waveguide System

We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, aCDOM, and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values and showed a linear response across all four pathlengths. Values of aCDOM measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of aCDOM for MPLCW measurements was 0.002 - 231.5 m-1. At low CDOM concentrations spectrophotometric aCDOM were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples.

Miller, Richard L.↗

Operational Characteristics of Four Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.

Ku, Yu-Tsuan E.↗

Biomedical Application of Aerospace Personal Cooling Systems

Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.

Ku, Yu-Tsuan E.↗

Operational Characteristics of Two Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

Ku, Yu-Tsuan E.↗