Optimization-based calibration of hydrodynamic drag coefficients for a semisubmersible platform using experimental data of an irregular sea state

For the simulation of the coupled dynamic response of floating offshore wind turbines, it is crucial to calibrate the hydrodynamic damping with experimental data. The aim of this work is to find a set of hydrodynamic drag coefficients for the semisubmersible platform of the Offshore Code Comparison Collaboration, Continuation, with Correlation and unCertainity (OC6) project which provides suitable results for an irregular sea state. Due to the complex interaction of several degrees of freedom (DOF), it is common to calibrate drag coefficients with the time series of decay tests. However, applying these drag coefficients for the simulation of an irregular sea state results in misprediction of the motions. By using numerical optimization, it is possible to calibrate multiple drag coefficients simultaneously and effectively, while also considering several DOF. This work considers time series of structural displacements from wave tank tests of the OC6 project and from simulations of the same load cases in OpenFAST. Results are transferred into the frequency domain and the deviation between power spectral densities of surge, pitch and heave from experiment and numerical simulation is used as an objective function to obtain the best fitting drag coefficients. This novel numerical optimization approach enables finding one set of drag coefficients for different load cases, which is a major improvement compared to decay-test-tuned drag coefficients.

42 ENGINEERING↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

An Operational Resilience Metric for Modern Power Distribution Systems

The electrical power system is the backbone of our nations critical infrastructure. It has been designed to withstand single component failures based on a set of reliability metrics which have proven acceptable during normal operating conditions. However, in recent years there has been an increasing frequency of extreme weather events. Many have resulted in widespread long-term power outages, proving reliability metrics alone do not provide adequate energy security. As a result, researchers have focused their efforts on a new set of metrics based on the concept of resilience to ensure efficient operation of power systems during extreme events. A resilient system has the ability to resist, adapt, and recover from disruptions. Therefore, resilience has demonstrated itself as a promising concept for currently faced challenges in power distribution systems. In this work, we propose a real-time resilience metric for modern power distribution systems. The metric is an aggregation of the controllable assets adaptive capacity, or their temporal flexibility in real and reactive power. This metric gives information to the magnitude and duration of a disturbance which the system can respond to without having to drop loads or have stability issues in voltage or frequency. We demonstrate the impact to resilience in a case study under normal operation and during a power contingency on a microgrid. In the future, this information can be used by operators to make more informed decisions based on system resilience in an effort to prevent power outages.

42 ENGINEERING↗

AMAROK: A Radio Frequency Development Platform for High-Power, Full-Scale Positive Ion Sources for DIII-D Neutral Beam Injectors

Next-generation neutral beam injection (NBI) systems demand RF ion sources capable of efficiently coupling >120 kW at 2–4-MHz frequencies, yet existing designs face voltage standoff and impedance-matching challenges. To address this, the advanced multicoil antenna for RF operations at kilowatts (AMAROK) was developed as a high-power RF inductively coupled plasma (ICP) source delivering up to 200 kW in the 2–4-MHz range via four phase-controlled generators for flexible power sharing. Two antenna designs—a single-strap multiturn (MT) and a multistrap single-turn (ST) design—were evaluated to optimize resonance, impedance matching, and power coupling across plasma loads. Here, a semi-analytical self-resonant frequency (SRF) model, validated experimentally, predicts resonance trends for arbitrary turn counts and tubing diameters, enabling rapid antenna optimization. Strap-to-strap mutual inductance in the ST configuration showed strong spatial dependence, guiding generator operation and total load inductance. These insights informed a custom π -topology matching network, achieving stable impedance matching over a wide range of plasma-driven loads. Collectively, these results position AMAROK as a versatile testbed for advancing high-power RF source technology in fusion NBI applications.

DIII-D↗

Utilization of Additive Manufacturing for the Rapid Prototyping of C-Band Radiofrequency Loads

Additive manufacturing is a versatile technique that shows promise in providing quick and dynamic manufacturing for complex engineering problems. Research has been ongoing into the use of additive manufacturing for potential applications in radiofrequency (RF) component technologies. Here, we present a method for developing an effective prototype load produced from 316L stainless steel on a direct metal laser sintering machine. The model was tested using simulation software to verify the validity of the design. The load structure was manufactured by an online digital manufacturing company, showing the viability of using easily accessible tools to manufacture RF structures. The produced load was able to produce an S11 value of −22.8 dB at a C-band frequency of 5.712 GHz while under a vacuum. In a high-power test, the load was able to terminate a peak power of 8.1 MW. The discussion includes future applications of the present method and how it will help to improve the implementation of future accelerator concepts.

36 MATERIALS SCIENCE↗

Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation

In this paper, we propose and solve a robust control problem for inverter-based resources under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance, grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the AC and DC sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, a robust control problem is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem. Then, in the middle layer a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Here, numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in literature to show the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Forming Interphase Microgrids in Distribution Systems Using Cooperative Inverters

Interphase-microgrids formed by three islanded single-phase feeders in distribution systems are proposed in this paper. Loss of utility caused by natural and human-made disasters may isolate each residential subdivision from the utility. In this case, the household loads are supplied by distributed generation (DG) units which may not be enough to meet the load demand. This can lead to deviations in voltage and frequency, and the deviations may vary for each phase. The proposed solution is to form an interphase-microgrid by seamlessly interconnecting the islanded single-phase feeders. This interphase-microgrid can effectively balance the load demands and DG generation in distribution systems after losing the utility supply. This paper presents different case studies to demonstrate the viability of forming interphase-microgrids for residential distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strain Gauge Diagnostic Development for use in Vessel Health Monitoring for Hydro-shots

Six-foot vessels are a crucial component to protecting high fidelity equipment at DARHT. Analysis shows these vessels have a limited life span (~10 shots) due to fatigue, ratcheting, and damage accumulation. Vessel health monitoring and diagnostics can help inform decision on a vessel’s fitness for service. Strain gauges are an easy and effective sensor for use in vessel health monitoring. In early March, J-2 executed a qualification shot, uniform blast loading with minimal fragments, with bi-axial strain gauges fielded at four locations around vessel. Several damage features were extracted from the data, and frequency content helps to validate computer modelling of the vessel response. Permanent plastic strain at each location was significant with location one having the most strain at the end state, with 230 micro-strain. However, residual pressure in the vessel could be a major factor in this strain. PEEQ is a measure of total plastic equivalent strain accumulation. The equivalent strain at location one exceeded the plastic strain limit four times and accumulated the most PEEQ with 2036 micro-strain. As expected, this qualification shot did contribute to damage in the vessel, and should be considered in its fitness for service, but not critical enough to pull it from service. Frequency content also gave valuable information on the modal response of the vessel and contributes to the understanding of how the vessel responds to the initial blast load with an expected lower frequency membrane/breathing mode and transitioning to higher frequency bending modes in the vessel wall.

42 ENGINEERING↗

Heterogeneous Fe‐N‐C Cocatalyst for Hydroquinone Oxidation Enables Aerobic Oxidation of Primary Alcohols to Aldehydes

Abstract Benzoquinone (BQ) is commonly used as a cocatalyst in multi‐component catalyst systems for aerobic oxidation of organic molecules. Such methods often proceed by a redox cascade in which a secondary catalyst supports aerobic oxidation of hydroquinone (HQ) to BQ. The present study shows that a commercially available non‐precious metal heterogeneous catalyst, PAJ‐Fe‐N‐C, is much more efficient than established homogeneous catalysts for aerobic oxidation of HQ to BQ, and this improved reactivity is crucial to support aerobic oxidation of primary alcohols to aldehydes with the homogeneous iridium catalyst, [Ir(trop 2 DAD]OTf (trop 2 DAD= N , N ‐bis(5‐ H ‐dibenzo[ a , d ]cycloheptene‐5‐yl)‐1,4‐diazabuta‐1,3‐diene). The combination of this heterogeneous/homogeneous catalyst system operates with Ir catalyst loadings as low as 0.05 mol % and turnover frequencies ≥350 h −1 .

Asmaul Hoque, Md [Department of Chemistry Universi↗

Heterogeneous Fe‐N‐C Cocatalyst for Hydroquinone Oxidation Enables Aerobic Oxidation of Primary Alcohols to Aldehydes

Abstract Benzoquinone (BQ) is commonly used as a cocatalyst in multi‐component catalyst systems for aerobic oxidation of organic molecules. Such methods often proceed by a redox cascade in which a secondary catalyst supports aerobic oxidation of hydroquinone (HQ) to BQ. The present study shows that a commercially available non‐precious metal heterogeneous catalyst, PAJ‐Fe‐N‐C, is much more efficient than established homogeneous catalysts for aerobic oxidation of HQ to BQ, and this improved reactivity is crucial to support aerobic oxidation of primary alcohols to aldehydes with the homogeneous iridium catalyst, [Ir(trop 2 DAD]OTf (trop 2 DAD= N , N ‐bis(5‐ H ‐dibenzo[ a , d ]cycloheptene‐5‐yl)‐1,4‐diazabuta‐1,3‐diene). The combination of this heterogeneous/homogeneous catalyst system operates with Ir catalyst loadings as low as 0.05 mol % and turnover frequencies ≥350 h −1 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the Value of Energy Storage for Power System Reliability and Resilience Applications

Abstract Purpose of Review The need for energy storage in the electrical grid has grown in recent years in response to a reduced reliance on fossil fuel baseload power, added intermittent renewable investment, and expanded adoption of distributed energy resources. While the methods and models for valuing storage use cases have advanced significantly in recent years, the value of enhanced resilience remains an open research question. Recent Findings The findings of the recent research indicate that energy storage provides significant value to the grid, with median benefit values for specific use cases ranging from under $10/kW-year for voltage support to roughly $100/kW-year for capacity and frequency regulation services. While the value of lost load is used widely to estimate the benefits of mitigating short-duration outages, reaching as high as $719/kilowatt-year, there is no consensus when it comes to monetizing the value of improving grid resilience. Summary This paper presents a use case taxonomy for energy storage and uses the taxonomy to conduct a meta-analysis of an extensive set of energy storage valuation studies. It reviews several approaches for monetizing reliability and resiliency services and presents a proposed approach for valuing resiliency for energy storage investments.

25 ENERGY STORAGE↗

Electric Vehicle Infrastructure Consequence Assessment

With consumers’ growing interest in electric vehicles, extreme fast charging stations are poised to provide high-power charging to rapidly recharge light-duty passenger vehicles. High-power charging requires high-level communication between vehicle and charger to govern the charging process. The coupling of power and communication increases the potential scale of cyberattacks. Using a full Western Electricity Coordinating Council planning model, load manipulation from high-power charging infrastructure is investigated. Two cases of load manipulation are studied: (i) a discrete, widespread system event and (ii) loads modulated near the Western Interconnect’s resonant frequency. In (i) some generation trips and in (ii) oscillations are observed on the California Oregon Intertie. Neither scenario results in significant adverse effects to the grid.

33 ADVANCED PROPULSION SYSTEMS↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Discovery of a Hybrid System for Photocatalytic CO 2 Reduction via Attachment of a Molecular Cobalt-Quaterpyridine Complex to a Crystalline Carbon Nitride

While recent reports have demonstrated the attachment of molecular catalysts to amorphous, graphitic carbon nitrides (g-CN) for light-driven CO 2 reduction, approaches to the utilization of crystalline carbon nitrides have remained undiscovered. Herein, a functional hybrid photocatalyst system has been found using a crystalline carbon nitride semiconductor, poly(triazine imide) lithium chloride (PTI-LiCl), with a surface-attached CoCl 2 (qpy-Ph-COOH) catalyst for CO 2 reduction. The molecular catalyst attaches to PTI-LiCl at concentrations from 0.10 to 4.30 wt % and exhibits ∼96% selectivity for CO production in a CO 2 -saturated, aqueous 0.5 M KHCO 3 solution. Optimal loadings were found to be within 0.42–1.04 wt % with rates between 1,400 and 1,550 μmol CO/g·h at an irradiance of 172 mW/cm 2 (λ = 390 nm) and apparent quantum yields of ∼2%. This optimized loading is postulated to represent a balance between maximal turnover frequency (TOF; 300+ h –1 ) and excess catalyst that can limit excited-electron lifetimes, as probed via transient absorption spectroscopy. An increase in the incident irradiance yields a concomitant increase in the TOFs and CO rates only for the higher catalyst loadings, reaching up to 2,149 μmol CO/g·h with a more efficient use of the catalyst surface capacity. The lower catalyst loadings, by comparison, already function at maximal TOFs. Higher surface loadings are also found to help mitigate deactivation of the molecular catalysts during extended catalytic testing (>24 h) owing to the greater net surface capacity for CO 2 reduction, thus representing an effective strategy to extend lifetime. The hybrid particles can be deposited onto an FTO substrate to yield ∼60% Faradaic efficiency for photoelectrochemical CO production at −1.2 V vs Ag/AgCl bias. In conclusion, these results demonstrate the synergistic combination of a crystalline carbon nitride with a molecular catalyst that achieves among the highest known rates in carbon-nitride systems for the light-driven CO 2 reduction to CO in aqueous solution with >95% selectivity.

CO2 reduction↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

The resilience value of residential solar + storage systems in the continental U.S.

Abstract Behind the meter rooftop solar plus storage (PVESS) has the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Whereas the bill reduction and environmental benefits of PVESS are well studied, its monetary resilience benefits are less understood. The increasing trend of power interruptions driven by extreme weather events heightens the need to understand these benefits. This study leverages various publicly available datasets to perform a cost benefit analysis of adding to determine the resilience value of PVESS for a typical single family home in each county in the continental U.S. We find that PVESS is very effective to technically mitigate interruptions across the country. However, the monetary benefits in the base case only cover about 14% of battery costs, with no county exceeding 60%. This is somewhat expected, given that PVESS provide other monetary benefits that are not part of this analysis. Through sensitivities, we find that higher frequency of extreme weather events roughly triples the resilience value of PVESS and that higher values of lost load double the same metric. Our sensitivity analysis shows that the benefit cost ratio of PVESS for customers living in areas with higher-than-average frequency of long duration interruptions and value of lost load is already above one even without considering other value streams. We conclude with recommendations that regulators and utilities could implement to enable customers to calculate and capture the resilience value of PVESS more efficiently.

Baik, Sunhee↗

Frequency-domain modeling of floating wind arrays with shared mooring lines

A frequency-domain model for floating wind turbine dynamics has been extended to model floating wind farms with couplings from shared mooring systems. The model, called RAFT, could previously calculate the mean offsets and wave-induced response spectra for single floating wind turbines. Now, the model supports multiple floating wind turbines, each with their own properties and responses, along with mooring lines that run directly between floating wind turbines in the array, meaning that shared mooring lines or fully suspended dynamic power cables can be included. This capability is achieved by setting up an array-level solution of the system mean offsets and assembling the full system matrices for solving the dynamic response. The quasi-static mooring model MoorPy is used to linearize the mooring system properties. To compute the floating wind turbine relative motions, phase offsets are applied to each turbine's response as a function of wave frequency based on the wavelength and relative positions in the array. These differential motions are then applied to mooring system tension Jacobians to compute the tension loads in the shared mooring lines. Overall, the capability provides a frequency-domain analog to the modeling capabilities of the floating support structure in FAST.Farm. Mean offsets and power spectral density plots of responses are compared between RAFT and FAST.Farm to verify the implementation. The results indicate good agreement within the expectations of a frequency-domain modeling approach and suggest correct implementation of the shared mooring aspects. Additionally, a unique comb-like frequency response in the shared mooring line tensions has been observed. This phenomenon has a clear physical basis and may be an important design consideration for future shared mooring systems.

17 WIND ENERGY↗

Autonomous Grid Support Functionality in Variable-Speed Drive-Based End-Use Loads

High penetration of inverter-based resources into power systems causes lower inertia, and it becomes more challenging to maintain grid stability during contingency events. While conventional demand response and shedding at the load side suffer from slow response, impact by unavailability, and issues from communication, variable-speed drives (VSDs) are becoming strong candidates for fast frequency response (FFR) thanks to their fast response and reduced user impact from variable power adjustment capability. In this letter, we propose an autonomous frequency support control method for a residential refrigerator with a VSD, a promising target small end-use load for FFR. We analyze the effect of the proposed controller on grid stability, and we verify the performance through laboratory experiments with a commercially available refrigerator.

24 POWER TRANSMISSION AND DISTRIBUTION↗