Harmonic cancellation within AC low voltage distribution for a realistic office environment

An increase of non-linear loads, primarily from power electronics, has substantially increased current harmonics in commercial buildings, which contributes to decreased transformer efficiency / lifespan and poor power quality. This study uses recorded power consumption data from common miscellaneous electric loads (MELs) seen in offices, combined with detailed characterizations of example MELs, to simulate harmonic cancellation within building circuits. Typically, harmonic cancellation studies assume that AC converters operate across their rated power range. However, this study finds that common MELs operate below 40% of rated power the majority of the time when not quiescent; 89% of sampled devices never operated above 60% of rated power. Simulations using these more realistic power levels indicate current-harmonic cancellation (3rd to 13th harmonic) is significantly lower than that predicted when using full-range power assumptions, resulting in minor errors for low-order harmonics and larger errors for higher order harmonics. Furthermore, increased MELs load diversity increases harmonic cancellation, but insufficiently to eliminate errors. In contrast, blending lighting loads with MELs on the secondaries of distribution transformers improves harmonic cancellation to near those predicted by traditional methods. These results indicate that realistic power levels, as well as better characterization of harmonics from typical MELs, should be used to estimate harmonic cancellation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind turbine response in waked inflow: A modelling benchmark against full-scale measurements

Predicting the power and loads of wind turbines in waked inflow conditions still presents a major modelling challenge. It requires the accurate modelling of the atmospheric flow conditions, wakes of upstream turbines and the response of the turbine of interest. Rigorous validations of model frameworks against measurements of utility-scale wind turbines in such scenarios remain limited to date. In this study, six models of different fidelity are compared against measurements from the DanAero experiment. The two benchmark cases feature a full-wake and partial-wake scenario, respectively. The simulations are compared against local pressure forces and inflow velocities measured on several blade sections of the downstream turbine, as well as met mast measurements and standard SCADA data. Regardless of the model fidelity, reasonable agreements are found in terms of the wake characteristics and turbine response. For instance, the azimuth variation of the mean aerodynamic forces acting on the blade was captured with a mean relative error of 15-20%. Additionally, while various model-specific deficiencies could be identified, the study highlights the need for further full-scale measurement campaigns with even more extensive instrumentation. Furthermore, it is concluded that validations should not be limited to integrated and/or time-averaged quantities that conceal characteristic spatial or temporal variations.

17 WIND ENERGY↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Techno-Economic Analysis of Repurposing Natural Gas Transmission Pipeline Networks to Accommodate Hydrogen Blends

Blending hydrogen into natural gas infrastructure could supplement natural gas supply and increase resilience for applications such as ammonia production, peaking and load-following power plants, and heating. The United States has an extensive network of natural gas pipelines, but the feasibility of employing this infrastructure to transport hydrogen is unclear. We analyze the costs associated with repurposing three distinct natural gas transmission pipelines in different locations within the United States to carry blends of hydrogen up to 100% via three different pipeline network modification methods and compare against the cost of building a new dedicated hydrogen pipeline. We conduct a sensitivity analysis on the hoop stress limit of the existing pipe, techno-economic parameters, emissions, and relative capacity. The results show that the capital costs required to upgrade a pipeline can vary from tens of millions to billions of dollars depending on the length and capacity of the existing pipeline section, whether the existing pipeline already operates at or below its maximum allowable operating pressure, whether future demand is expected to increase or decrease, the network modification method selected, and pipe material costs. The delivered cost of energy to end users is impacted less by the levelized cost of transporting hydrogen blends than by the cost of the natural gas and hydrogen fuels being transported. The emissions impact of blending hydrogen into natural gas transmission networks scales proportionally with the amount of energy displaced with low-emission hydrogen (such as from natural gas with carbon capture and sequestration or electrolysis powered by nuclear, renewable, or geothermal electricity), therefore low blend ratios (e.g., < 20% vol. hydrogen) will result in low emissions impacts. Factors such as permitting and right-of-way costs, the proximity of the pipeline to hydrogen demand and production, and the compatibility of and/or retrofitting costs of end-use gas-fueled technologies will likely be greater drivers in determining whether converting a particular natural gas pipeline to carry hydrogen makes economic sense.

08 HYDROGEN↗

Ion temperature anisotropy in the tokamak scrape-off layer

Understanding tokamak exhaust-power heat loads on divertor plates depends critically on having a realistic model of the scrape-off layer (SOL) plasma. The Braginskii fluid model is often solved to understand the SOL plasma behavior. This model is based on the collisional limit for transport along the magnetic field B → . The ions and electron gyrofrequencies are assumed to be much larger than the Coulomb collision frequencies, which are nonetheless, sufficiently large to yield common parallel and perpendicular temperatures for each species, i.e. the temperatures are assumed to be isotropic. Additionally, in certain circumstances such as encountered for the tokamak H-mode, the ion temperature can be quite anisotropic. In this work, the anisotropy effects are implemented in the two-dimensional (2D) transport code UEDGE. Various geometries (1D slab, 2D slab and a toroidal tokamak geometry) are used to study the 2D structure of ion temperature anisotropy and its effects on plasma transport in detail. Results show that the effects of ion temperature anisotropy on the plasma parallel transport are substantial near the magnetic X-point, which leads to different steady state density profiles in the divertor regions. The extra mirror force introduced by ion temperature anisotropy can be one of the main forces contributing to the plasma flow in the SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Do ambient shear and thermal stratification impact wind turbine tip-vortex breakdown?

Modern wind turbines experience uneven inflow conditions across the rotor, due to the ambient flow’s shear and thermal stratification. Such conditions alter the shape and length of turbine wakes and thus impact the loads and power generation of downstream turbines. To this end, understanding the spatial evolution of the individual wakes under different atmospheric conditions is key to controlling and optimising turbine arrays. With this numerical study we aim to obtain a better understanding of the fundamental physics governing the near-wake dynamics of wind turbines under shear and thermal stability, by examining their tip-vortex breakup mechanisms. Our approach considers scale-resolving simulations of a single turbine wake under a linear shear profile as well as the application of harmonic tip perturbations to trigger flow instabilities. For the subsequent analysis we use the proper orthogonal decomposition (POD) method to extract coherent structures from the flow, and we also calculate mean kinetic energy fluxes to quantify each coherent structure’s contribution to wake recovery. The wake’s helical spiral is found to hinder wake recovery for all studied ambient flow conditions, whereas the mutual inductance instability has positive MKE flux leading to an enhanced wake recovery. Finally, the ambient shear has the largest impact on the local MKE flux with respect to downstream location by changing the shape of the curve and location of extrema, whereas thermal stratification has only a minimal impact on the magnitude of the near-wake local MKE flux distribution.

17 WIND ENERGY↗

Direct Envelope Modeling of Load-Resonant Inverter for Wireless Power Transfer Applications

This paper presents the application of direct envelope modeling technique to primary side LCC tuned resonant wireless power transfer system. The method adapted here decomposes the HF resonant inverter output to a fundamental component and two dominant sidebands. The small-signal dutycycle-to-primary-coil-current-envelope transfer function of a primary side LCC tuned WPT system is then derived as the summation of the responses to the fundamental and the sideband components. The theoretical and simulation results are in good agreement indicating the validity of the approach to be applied to WPT systems.

Galigekere, Veda Prakash↗

Hierarchical Model-Free Transactive Control of Residential Building Loads: An Actual Deployment

The transformation of electricity systems into more sustainable configurations brought some new challenges. The uncertain, intermittent, and variable nature of renewable energy sources require a significant amount of load demand flexibility, in which grid-interactive buildings (GEBs) are important flexible assets for electricity systems. In this regard, many demand response (DR) tools have been developed to harness this demand flexibility. However, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a real-world field implementation and testing of a hierarchical model-free transactive DR control approach on actual GEBs. The control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. The proposed approach was tested using a total of five GEBs, each having three zones. The results show that the proposed approach can mostly achieve all intended objectives, including flexibility estimation, peak load reduction, power tracking, and controlling GEBs while maintaining occupants’ comfort.

Amasyali, Kadir↗

dsgrid (Demand-Side Grid Toolkit) [SWR-21-52]

The demand-side grid model harnesses decades of sector-specific energy modeling expertise to understand current and future U.S. electricity load for power systems analyses. The API provides tools for submitting datasets to dsgrid projects, validating individual datasets and project data as a whole, querying, analysis, and visualization.

Hale, Elaine↗

thevenin: An Equivalent Circuit Modeling Package [SWR-24-132]

This package is a wrapper for the well-known Thevenin equivalent circuit model for simulating battery behavior with a focus on ease of use. The model is comprised of a single series resistor followed by any number of parallel RC pairs. The package includes an intuitive "experiment" interface, which simplifies the programming of constant or dynamic current, voltage, and/or power-driven loads, making it ideal for a wide range of applications, from basic tests to complex simulations. It also supports state-of-charge (SOC) and temperature-dependent properties, allowing the model to be more easily calibrated against real cells.

Randall, Corey↗

ANL Design Team Analysis: Transportable Modular Reactor by Balance of Plant Elimination

HolosGen LLC is developing “Holos-Quad” a transportable gas-cooled reactor, with integral load following power conversion systems equipping subcritical power modules (SPMs), fully comprised within standard transport containers. The design eliminates the Balance of Plant (BoP) and greatly simplifies the design layout. A closed-loop full Brayton gas thermodynamic cycle converts the fuel cartridges thermal energy into electricity. This ARPA-E project utilizes advanced reactor modeling tools and manufacturing-testing of a scaled SPM equipped with a surrogate fuel cartridge to eliminate the most significant technology gaps to accelerate commercialization. The Argonne Design Team contributes to the research by demonstrating feasibility of various aspects of the Holos-Quad design by performing high-fidelity neutronic modeling, and investigating various reactivity control systems. This work consists of two main tasks: evaluation of HolosGen’s design features and alternative options study for reactivity control.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Techno-Economic Analysis Using REopt for Community Solar on Multifamily Affordable Housing Properties [Slides]

Multifamily affordable housing (MFAH) providers can identify and prioritize properties in their portfolios for which community solar development is feasible by following portfolio screening steps in a process outlined by NREL. Once MFAH providers have identified the most feasible sites, they can conduct more detailed analyses for a select number of sites to assess how distributed energy resources such as solar plus storage can help them meet their goals. The step is completed using NREL's REopt (https://reopt.nrel.gov/tool), a free techno-economic optimization model that determines DER sizes and dispatch strategies that minimize the life cycle cost of energy at a site. This presentation describes how to perform this step using REopt to help MFAH providers answer questions such as: What size solar PV system will result in the most energy bill savings at this site? What size solar-plus-storage system would be needed to power critical loads through a utility grid outage? What is the financial impact of rate switching, net metering, and/or meter aggregation? What percentage of the site's load can be offset with renewable energy? What are the emissions benefits of this renewable generation?

14 SOLAR ENERGY↗

MG-RAVENS: Working Group Update [Slides]

Problem Statement: Users in industry, who are planning the deployment and operation of microgrids, face a multi-domain problem that requires multiple engineering tools to solve; Existing tools lack interoperability, which requires tedious recreation and conversion of equipment models, and creates opportunities for errors in translation or through inconsistent assumptions; Microgrid modelers waste time reinventing the wheel because it is challenging to reuse existing distribution, load, generation, power flow, optimization models for new use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Can a Nuclear-Assisted Biofuels System Enable Liquid Biofuels as the Economic Low-carbon Replacement for All Liquid Fossil Fuels and Hydrocarbon Feedstocks and Enable Negative Carbon Emissions?

This report integrates the results of a series of studies and workshops to address the question: Can a nuclear-assisted biofuels system enable liquid biofuels as the economic low-carbon replacement for all liquid fossil fuels and hydrocarbon feedstocks and simultaneously enable negative carbon emissions? “Economic” is defined as economically competitive relative to other low-carbon replacement options for crude oil. “All” refers to the capability to replace the 18 million barrels of oil per day used by the United States. “Nuclear-assisted” refers to the provision of massive quantities of low-carbon heat and hydrogen at the refinery to fully utilize the carbon content of the cellulosic biomass feedstocks for liquid hydrocarbon production. A system is proposed that decarbonizes about half of the U.S. economy while improving long-term soil productivity and sequestering carbon from the atmosphere. In the U.S. almost half the energy consumed by the final customer is in the form of liquid hydrocarbons produced from crude oil. Liquid hydrocarbons are used as (1) an energy source, (2) a method for daily-to-seasonal energy storage, (3) a chemical feedstock, (4) a chemical reducing agent, (5) a method to enhance high-temperature heat transfer in many furnaces and industrial processes and (6) other purposes. As a consequence, the U.S. consumes ~18 million barrels of crude oil per day to produce liquid hydrocarbons. While there are substitutes for liquid hydrocarbons for some applications, our assessment is that the costs and difficulty will dramatically increase if liquid hydrocarbon use goes much below the equivalent of 10 million barrels per day of crude oil. New uses of liquid hydrocarbons to partly replace coal and natural gas could increase demand beyond the equivalent of 10 million barrels of oil per day. One can produce and burn liquid hydrocarbons from biomass without any net addition of carbon dioxide to the atmosphere. Plants grow by removing carbon dioxide from the atmosphere; thus, burning biomass does not result in any net addition of carbon dioxide to the atmosphere. Biomass is typically 40% oxygen. To remove this oxygen to create hydrocarbon liquids, there are two options. The first option is to use biomass as (1) a feedstock, (2) an energy source to operate the process and (3) a supply of carbon to remove the biomass oxygen as carbon dioxide. The second option is to use external heat and hydrogen to remove the oxygen as water and produce liquid hydrocarbons. The use of massive quantities of external heat and hydrogen for hydrocarbon liquid fuels production reduces the biomass feedstock per unit of liquid hydrocarbon product by more than a factor of two reducing land use by more than a factor of two. Many cellulosic feedstocks unsuitable for liquid hydrocarbon production are viable feedstocks with external heat and hydrogen inputs. As a result, there is sufficient cellulosic feedstocks to meet U.S. and global liquid fuels hydrocarbon demand without significant impacts on food and fiber prices. The heat and hydrogen (heat plus electricity) are produced using base-load nuclear power plants—the most economic form of nuclear energy. If low-price natural gas, there is also the option of producing hydrogen from natural gas with sequestration of the carbon dioxide. The biomass is locally processed in depots to produce commodity feedstocks that can be shipped long distances to large biorefineries (250,000 barrels per day, oil equivalent) similar to existing refineries except modifications of front-end processes. The depot system enables local recycle of nutrients back to the soil. The biorefinery can produce variable quantities of liquid hydrocarbon fuels and carbon dioxide for sequestration enabling removal of carbon dioxide from the atmosphere. Preliminary estimates are that the liquid hydrocarbon costs are equivalent to crude oil at between $60 and $70 per barrel. The largest cost is for hydrogen with biomass feedstocks and refinery costs a smaller fraction of the total cost.

09 BIOMASS FUELS↗

Characterization of Harsh Environments, At-Risk Microgrid Components, and Hardening Technologies (Report Version 0.1)

Microgrid implementation can help improve electrical service, reliability, and resilience for localized communities. However, they may be susceptible to damage from natural disasters and extreme weather events, which often coincide with times of greater community dependence on microgrids due to likely increased vulnerability of equipment on the main grid. Microgrid equipment can be protected against these hazards through various hardening techniques. The selection of hardening mitigations may depend on the actual risk of the hazard in the specific location and for the specific type of system, as well as cost and feasibility factors. This report summarizes a framework that can be used to characterize risk to a microgrid system from a list of natural hazards enumerated by FEMA. We also describe hardening techniques and mitigations that can be used for specific energy generation, storage, loads, and power delivery elements within a microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗