Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

HBU R and D Cask Transportation Options - 20436

The TN-32B HBU Demonstration Cask was successfully loaded in November 2017 with 32 high burnup (HBU) fuel assemblies at Dominion's North Anna Nuclear Plant and is collecting thermal data as intended. The first two phases of this very successful project sponsored by DOE and EPRI was designed to collect thermal data of HBU fuel to support extended storage. The next phase of the project requires the cask be licensed for transportation so the cask can be relocated to a site (to be determined by DOE) to facilitate long term monitoring and additional research on the fuel. This is a unique challenge given the constraints that exist for this particular bolted metal cask. The TN-32B cask is a 234,288 lb. (storage configuration) dry storage system that was selected for this project and it was modified to provide thermal data and the ability to collect gas samples after loading. Several major issues must be addressed to obtain the transport license including protecting the seven lid penetrations that were made to allow for the insertion of the thermocouples into the selected fuel assemblies after the cask was loaded. In order to protect the integrity of the research, the payload must remain as is. Therefore, the cask system must be placed into the transportation configuration without rewetting the fuel, replacing the lid and without removing the thermocouple instrumentation that is currently installed. A critical portion of the design and engineering that was performed in the first two phases of the project was to ensure that future transportation of the cask was integrated into the approach. Efforts were made to accommodate requirements such as containment boundary leakage testing, installation of impact limiter brackets and lid bolts suitable for transportation. Due to the science requirements of the project, the fuel selected was intended to yield the highest payload temperatures permitted to provide the greatest value for the researchers. This resulted in higher than usual external dose rates and surface temperatures that warranted performing as much preparatory work prior to cask loading to ensure ALARA and personnel safety to the greatest extent practical rather than working on a loaded cask. In addition to the work performed prior to cask load, there are remaining challenges such as protecting the modified lid, design and fabrication of impact limiters that accommodate the modified cask lid and preserving the thermocouple connections for continued monitoring. The project team is currently performing the necessary calculations, engineering, and design to support the licensing as required by the US NRC. Pre-application meetings have been held to inform the regulator of the planned technical approach to ensure compliance with the applicable regulations. The current plan is to obtain the transportation C of C by the end of 2021. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Nuclear Spent Fuel Disposal in Clay-Bearing Rock - Process Model Development and Experimental Studies (M2SF-21SN010301072)

The DOE R&D program under the Spent Fuel Waste Science Technology (SFWST) campaign has made key progress in modeling and experimental approaches towards the characterization of chemical and physical phenomena that could impact the long-term safety assessment of heatgenerating nuclear waste disposition in deep-seated clay/shale/argillaceous rock. International collaboration activities such as heater tests, continuous field data monitoring, and postmortem analysis of samples recovered from these have elucidated key information regarding changes in the engineered barrier system (EBS) material exposed to years of thermal loads. Chemical and structural analyses of sampled bentonite material from such tests as well as experiments conducted on these are key to the characterization of thermal effects affecting bentonite clay barrier performance and the extent of sacrificial zones in the EBS during the thermal period. Thermal, hydrologic, and chemical data collected from heater tests and laboratory experiments has been used in the development, validation, and calibration of THMC simulators to model near-field coupled processes. This information leads to the development of simulation approaches (e.g., continuum and discrete) to tackle issues related to flow and transport at various scales of the host-rock, its interactions with barrier materials, and EBS design concept.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impacts of Hurricane Disturbance on Water Quality across the Aquatic Continuum of a Blackwater River to Estuary Complex

Hurricanes cause landscape-scale disturbances that affect biogeochemical cycling and water quality in coastal ecosystems. During Hurricane Irma’s passage through northern Florida, water movements driven by wind velocities up to 105 km h-1 caused a salinity peak in an estuary/blackwater river complex. Water quality was monitored across the 15 km site to detect the magnitude and duration of disturbance. Saline water intruded 15 km inland into a freshwater portion of the river that peaked at a salinity of 2 psu. Due to the volume of precipitation from the hurricane, significant runoff of freshwater and dissolved organic matter (DOM) caused a decrease in salinity, dissolved oxygen (DO), and Chlorophyll-a concentrations while increasing turbidity and fluorescent dissolved organic matter (fDOM). The disturbance caused rapid changes observed by in-situ water quality monitors over a 3-week period, but some effects persisted for longer periods as shown by 3-month weekly water sampling. This disturbance caused shifts in DOM loading, altered salinity dynamics, and reshaped landscapes due to wind and wave surge both in upland marsh and downstream estuary. Hurricane disturbance temporarily and abruptly alters the aquatic continuum, and observations of system response can help us understand the mechanisms associated with ecosystem resilience and recovery.

54 ENVIRONMENTAL SCIENCES↗

Label-Free Anti-Brownian Trapping of Single Nanoparticles in Solution

Today, biomolecular nanoparticles are prevalent as diagnostic tools and molecular delivery carriers, and it is particularly useful to examine individuals within a sample population to quantify the variations between objects and directly observe the molecular dynamics involving these objects. Using interferometric scattering as a highly sensitive label-free detection scheme, we recently developed the interferometric scattering anti-Brownian electrokinetic (ISABEL) trap to hold a single nanoparticle in solution for extended optical observation. In this perspective, we describe how we implemented this trap, how it extends the capabilities of previous ABEL traps, and how we have begun to study individual carboxysomes, a fascinating biological carbon fixation nanocompartment. By monitoring single nanocompartments for seconds to minutes in the ISABEL trap using simultaneous interferometric scattering and fluorescence spectroscopy, we have demonstrated single-compartment mass measurements, cargo-loading trends, and redox sensing inside individual particles. These experiments benefit from rich multiplexed correlative measurements utilizing both scattering and fluorescence with many exciting future capabilities within reach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AN AUTOMATED ANCHORING SYSTEM FOR AN UNMANNED SURFACE VEHICLE

The goal of this thesis is to simulate, design and build an automated device that allows unmanned vessels to anchor themselves in specified locations while being United States Coast Guard Navigation Rules compliant. This is a part of a larger project funded by the U.S. Department of Energy for Florida Atlantic University to build an unmanned platform with an Undershot Water Wheel on it. By simulating the environment of the South Florida Intercoastal Water Ways, forces acting on the line, anchor and the vessel are analyzed. These forces are used as the guide for the design and build of a line locking mechanism that takes the tension off the winch and a sensor package to monitor the environment the platform is in as well as control of the system. Based off experimental testing, the system was successful in handling all emulated environments with loads exceeding 150lbs of tension.

Fosbrook, Amanda↗

Demonstration of the surveillance test article for an advanced reactor surveillance test program

Operational environments in generation IV reactors involve corrosive and irradiative conditions at elevated temperatures. Typical reactor operations consist of transients which impose cyclic loads on reactor components. These cyclic loads, combined with corrosive and irradiative environments, result in synergistic degradation of component materials. However, limited data exists on the coupled damage effects on materials for reactor environments. While the surrogate material surveillance concept has been used in light water reactors to assess irradiation damage, existing material surveillance technologies are not suitable for in-situ monitoring of coupled material degradation. The materials surveillance program focuses on material degradation management and the estimation of remaining life of reactor components through surveillance test articles. This paper presents the design and analysis methodology of a bi-metal surveillance test article, which uses difference in thermal expansion coefficient between two metals to induce in-situ cyclic loads. This report presents the work conducted in FY 25, to test the surveillance test article in air and salt environments. These test specimens were evaluated after thermal cycle exposure and remaining life is measured through creep test.

36 - MATERIALS SCIENCE↗

Real-time Simulation Model of a Vanadium Redox Flow Battery Energy Storage System with Power Electronics Integration

This paper presents a real-time (RT) model of a 20 kW multi-stack vanadium redox flow battery (VRFB) system including power electronics converters in a single real-time framework. Implemented on a Typhoon HIL 604 device, this model is designed to simulate the operation of the flow battery with system-level controls. To provide a realistic overview of a VRFB system, the model incorporates a closed-loop control system for managing the speeds of two centrifugal pumps and an electro-thermal model of the battery stacks, enabling realtime temperature estimation. Furthermore, a two-stage power electronics topology and associated control solution are presented, operating with distinct strategies for interfacing the battery model with the main grid and a local load. Results from simulations demonstrate that the VRFB model is well suited for RT environment, and system can manage power during both charging and discharging cycles, while a SCADA monitor is used to display critical variables for safe, efficient, and reliable operation of the VRFB systems.

Rezende Da Costa Reis Kimpara, Renata [ORNL] (ORCI↗

Fracture Sustainability in Enhanced Geothermal Systems: Experimental and Modeling Constraints

Enhanced geothermal systems (EGS) offer the potential for a much larger energy source than conventional hydrothermal systems. Hot, low-permeability rocks are prevalent at depth around the world, but the challenge of extracting thermal energy depends on the ability to create and sustain open fracture networks. Laboratory experiments were conducted using a suite of selected rock cores (granite, metasediment, rhyolite ash-flow tuff, and silicified rhyolitic tuff) at relevant pressures (uniaxial loading up to 20.7 MPa and fluid pressures up to 10.3 MPa) and temperatures (150–250 °C) to evaluate the potential impacts of circulating fluids through fractured rock by monitoring changes in fracture aperture, mineralogy, permeability, and fluid chemistry. Because a fluid in disequilibrium with the rocks (deionized water) was used for these experiments, there was net dissolution of the rock sample: this increased with increasing temperature and experiment duration. Thermal-hydrological-mechanical-chemical (THMC) modeling simulations were performed for the rhyolite ash-flow tuff experiment to test the ability to predict the observed changes. These simulations were performed in two steps: a thermal-hydrological-mechanical (THM) simulation to evaluate the effects of compression of the fracture, and a thermal-hydrological-chemical (THC) simulation to evaluate the effects of hydrothermal reactions on the fracture mineralogy, porosity, and permeability. Furthermore, these experiments and simulations point out how differences in rock mineralogy, fluid chemistry, and geomechanical properties influence how long asperity-propped fracture apertures may be sustained. Such core-scale experiments and simulations can be used to predict EGS reservoir behavior on the field scale.

15 GEOTHERMAL ENERGY↗

Experimental Investigation on the Performance Loss of Cross-Linked Polymers During Photo-Oxidative Aging

Abstract Polymeric substances have seen an unprecedented integration in countless applications and fields of life, subjecting them to a broad range of environmental conditions, which can cause a form of damage to the structural and mechanical properties of these components known as aging. In this study we investigate the effects of the degradation of polymeric materials due to the extended exposure to sunlight, which can be simulated through controlled photo-oxidative aging using ultraviolet (UV) radiation as the main catalyst of this phenomenon. The effects on mechanical behavior and chemical properties of four polymeric materials with different mechanical characteristics was accordingly monitored throughout the study. The materials range in hardness with the polyurethane adhesive being the hardest and acting plastically, followed by an acrylic which exhibits greater hardening with time, a polyurethane sealant, which behaves in an elastomeric manner, and a silicon sealant, which is the softest of the set. Samples were prepared and subjected to UV radiation at three different temperatures namely 45, 60 and 80°C, for different aging periods ranging from 1 day for higher temperatures to 150 days for lower ones. The samples were then subjected to the Fourier transform Infrared spectroscopy (FTIR) test to monitor the change in the chemical composition of the materials along the aging durations and conditions. The materials were then subjected to mechanical testing along two modes of mechanical loading, which are a simple tension until failure and a double-cyclic test with progressively increasing strain limits after every two successful cycles until the sample reaches failure. The samples are loaded at constant strain rates throughout both tests. These tests revealed the change of behavior of our materials along the aging periods and conditions. The changes in mechanical behavior vary across each individual material depending on the aging temperature and period, with the changes ranging from hardening to softening, embrittlement or an increase in the maximum strain the material can endure before failure. A general trend would be that most materials become harder after photo-oxidation, however due to the range of temperatures in the aging conditions, thermo-oxidation, which causes softening in some of the polymers, has an increasingly notable effect at higher temperatures. A visible correlation can be noted between the change in mechanical behavior and a change in absorbance of Infrared Radiation (IR) in the FTIR spectrum, as the greater the crosslinking throughout the polymer matrix, the lower the absorbance of IR radiation due to the increased stiffness of the overall macro-molecular structure.

Korayem, Abd-Elrahman↗

Unlocking Failure Mechanisms and Improvement of Practical Li-S Pouch Cells Through in Operando Pressure Study

For Lithium-sulfur (Li-S) battery commercialization, the study at a pouch cell level is essential, as some problems ignored or deemed minimal at the smaller level could have a greater effect on the performance of the larger pouch cell. Herein, the failure mechanisms of Li-S pouch cells are deeply investigated via in operando pressure analysis. It is found that highly porous structures of cathodes/separators and slow electrolyte diffusion through cathodes/separators can both lead to poor initial wetting. Additionally, Li-metal anode dominates the thickness variation of the whole pouch cell, which is verified by in situ measured pressure variation. Consequently, a real-time approach that combined normalized pressure with dP/dV analysis is proposed and validated to diagnose the morphology evolution of Li-metal anode. Moreover, applied pressure and porosity/tortuosity ratio of the cathode are both identified as independent factors that influence anode performance. In addition to stabilizing anodes, high pressure is proven to improve the cathode connectivity and avoid cathode cracking over cycling, which improves the possibility of developing cathodes with high sulfur mass loading. This work provides insights into Li-S pouch cell design (e.g., cathode and separator) and highlights pathways to improve cell capacity and cycling performance with applied and monitored pressure

25 ENERGY STORAGE↗

Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

A. Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development for a PC-Fired Unit

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at Coalfired Power Plants

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Full-scale Demonstration of Multi-process Sensor at a Cycling PC-fired Boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Hybrid Analytics Solution for Power Plant Operations

Expert Microsystems, Inc., MapEx Software Inc. and XMPLR Energy LLC have teamed to submit a proposal to the US Department of Energy’s Office of Fossil Energy to improve the efficiency, reliability and flexibility of existing coal-based power plants. The project, titled Hybrid Analytics Solution to Improve Coal Power Plant Operations (the “Hybrid Analytics” project), will develop, demonstrate and commercialize a novel approach that integrates two proven real-time monitoring techniques. The Hybrid Analytics approach integrates into a single, integrated solution: a) an established, advanced data-driven analytics solution that includes artificial intelligence, advanced pattern recognition and machine-learning techniques and b) a well-proven, first principle thermal heat balance model solution. The future role of coal plants will depend on the ability to cycle and follow loads to meet marginal power demands, accommodate renewables and support the grid. Essential to success in this new role is a plant’s ability to maintain high reliability, efficiency and flexibility. However, these changing operational demands put significant stresses on power plant components that directly impact the ability to deliver these requirements. In the past, plants have independently monitored performance using physics-based solutions (heat rate, boiler losses, etc.) and reliability using data-driven analytics (advanced pattern recognition). The Hybrid Analytics solution integrates both approaches to enhance fault detection, provide automated diagnostics and estimates of remaining time to act, and provide critical, enhanced and accurate real-time information to coal plant operators. As a result, coal plants can improve efficiency, reliability, and flexibility and can cost-effectively maintain their key role in the power delivery system.

01 COAL, LIGNITE, AND PEAT↗

Unlocking Failure Mechanisms and Improvement of Practical Li–S Pouch Cells through In Operando Pressure Study

For Lithium-sulfur (Li-S) battery commercialization, the study at a pouch cell level is essential, as some problems ignored or deemed minimal at the smaller level could have a greater effect on the performance of the larger pouch cell. Herein, the failure mechanisms of Li-S pouch cells are deeply investigated via in operando pressure analysis. It is found that highly porous structures of cathodes/separators and slow electrolyte diffusion through cathodes/separators can both lead to poor initial wetting. Additionally, Li-metal anode dominates the thickness variation of the whole pouch cell, which is verified by in situ measured pressure variation. Consequently, a real-time approach that combined normalized pressure with dP/dV analysis is proposed and validated to diagnose the morphology evolution of Li-metal anode. Moreover, applied pressure and porosity/tortuosity ratio of the cathode are both identified as independent factors that influence anode performance. In addition to stabilizing anodes, high pressure is proven to improve the cathode connectivity and avoid cathode cracking over cycling, which improves the possibility of developing cathodes with high sulfur mass loading. Here, this work provides insights into Li-S pouch cell design (e.g., cathode and separator) and highlights pathways to improve cell capacity and cycling performance with applied and monitored pressure.

25 ENERGY STORAGE↗