Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Future of the MUSiC Experiment Data

The Measurements of Uranium Subcritical and Critical (MUSiC) experiment was a highly enriched uranium (HEU) experiment performed at the National Criticality Experiments Research Center (NCERC) executed between December 2020 and April 2021. The experiment intended to measure criticality and reactor kinetics parameters in a bare HEU system. The experiment concurrently measured radiation signatures from the system while utilizing different neutron source types. This was an attempt to benchmark both detectors and analysis techniques against one another for identical measurements. The experiment consisted of the Rocky Flats HEU hemi-shells constructed into ten configurations spanning between deeply subcritical (about 14 kgs) to supercritical (about 60 kgs). Two of the ten configurations were supercritical and the other eight were subcritical. The two supercritical configurations, often referred to as the critical configurations, were documented into an International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmark evaluation and submitted to the technical review group (TRG). The subcritical configurations of the MUSiC experiment were examined using three different detection systems. The systems include: the NoMAD He-3 neutron detector which consists of 15 He-3 tubes surrounded by a polyethylene matrix, a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD), and a trans-stilbene organic scintillator array (OSCAR) provided by the University of Michigan. The NoMAD and RAM-RODD data are planned to be evaluated in two separate ICSBEP evaluations utilizing neutron noise methods such as Feynman Variance-to-Mean, Rossi-α and the pulsed neutron source method. Each of the subcritical configurations were examined using three different source types including: a Cf-252 source in the center, with only the intrinsic neutron source in the HEU, and with an external D-T neutron generator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of the MUSIC 3 He Multiplicity Data

A measurement campaign called the Measurement of Uranium Subcritical and Critical (MUSiC) was performed on a range of configurations of highly-enriched uranium (HEU) from December 2020 through April of 2021. While part of the focus was to measure reactor kinetics parameters on delayed supercritical systems, an additional focus was performing neutron noise measurements on subcritical configurations from deeply subcritical to nearly delayed critical. Multiple detector systems were used to perform these measurements, such as a 3 He multiplicity detector called the Neutron Multiplicity Array Detector (NoMAD) and a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD). Also included were a scintillator system from the University of Michigan and a set of small 3He tubes that have previously been used to measure Rossi-α values on near-critical systems. The focus of this paper will be a comparison of prospective analysis methods for the NoMAD measurements. Previous subcritical measurements at the National Criticality Experiments Research Center (NCERC) submitted to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) used the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This relies on the time correlations of neutron detections to infer the spontaneous fission rate and neutron multiplication of a system through binning the time tagged detections and analyzing resulting histograms of the numbers of counts. However, there are other neutron noise methods that rely on similar processes, such as the Hansen-Dowdy formalism which uses a slightly different methodology to extract multiplication from the neutron multiplicity counting moments. Comparisons can be made between these experimental results and those obtained through simulations to validate or identify deficiencies in analysis, detection methods, or the underlying nuclear data. Different time gating strategies and their effects on count rate uncertainties are also investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Road to PROSPECT-II

The Precision Reactor Oscillation and SPECTrum (PROSPECT) experiment is based in a segmented liquid scintillator antineutrino detector situated approximately 7 meters from the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Its main goal is to investigate short-baseline antineutrino oscillations. The first phase of data collection, known as PROSPECT-I, was held from 2018 to 2019 and was used for several high-precision analyses, including multiple measurements of the $^{235}U$ antineutrino spectrum and searches for $eV$-scale sterile antineutrino oscillations. The collaboration is now preparing for the second phase, PROSPECT-II, which features an upgraded detector design. This advancement will enhance sensitivity and statistical power, allowing for a broader range of analyses beyond those achieved in PROSPECT-I. As we transition into this new phase, new questions have arisen concerning background simulation and its potential differences from those conducted during the initial phase of the experiment. Moreover, it is essential to ascertain, through simulations, the positive effects that an improved detector could have on the study of oscillations. This information is crucial for justifying the proposed enhancements, and I will cover all of this in the talk.

43 PARTICLE ACCELERATORS↗

Measuring the Muon Neutrino Magnetic Moment in the NOvA Near Detector

Measuring an enhanced neutrino magnetic moment would be a clear indication of physics beyond the Standard Model, shedding light on the correct beyond Standard Model theory or the potential Majorana nature of neutrinos. It would manifest in the NOvA near detector as an excess of neutrino-on-electron elastic scattering interactions at low electron recoil energies. Leveraging an intense and highly pure muon neutrino beam, along with a finely segmented liquid scintillator detector technology specifically designed for electromagnetic shower separation, enables NOvA to achieve a potentially world-leading sensitivity in probing the effective muon neutrino magnetic moment. This analysis, based on neutrino data collected between 2014 and 2021, corresponding to an exposure of $13.8\times10^{20}$ protons-on-target, yields a result consistent with the Standard Model-only hypothesis with a p-value of 0.31. An upper limit on the effective muon neutrino magnetic moment is set at $\mu_{\nu_\mu}<19.1\times 10^{-10}\mu_B$ at $90\%$ confidence level. Despite facing statistical limitations stemming from low cross section of the signal process, systematic uncertainties have a significant impact on this result. To address these challenges, the NOvA Test Beam experiment focuses on mitigating some of the largest systematic uncertainties within NOvA by investigating particle interactions and energy deposition in a small-scale replica NOvA detector. This thesis describes the calibration of the NOvA Test Beam detector, which is a crucial step in analysing the Test Beam data before they can be utilised to reduce NOvA systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Colloidal Behavior of Plutonium Oxide in Concentrated Electrolyte Solutions

The Hanford Site in Washington State manages legacy high-level radioactive waste streams that display major chemistry and engineering challenges, including the high salt levels and pH values that correspond to conditions under which many classical concepts describing chemical reactivity cannot be applied. One particular challenge that needs to be tackled at Hanford is that Pu concentrations, [Pu], in the soluble phases of the tank wastes are higher than expected based on the solubility of crystalline PuO2, which is widely accepted to be caused by the formation of PuO2 colloid, consisting of nano- to submicron-sized particles (PuO2 NPs). Fundamental research underpinning the behavior of PuO2 NPs under conditions not only relevant to the Hanford tank waste but at high ionic strength in general is needed to reliably predict the chemical reactivity of PuO2 NPs and develop engineering solutions to safely and efficiently process high-level radioactive waste into forms suitable for long-term storage. In this work, we study the behavior of PuO2 NPs (particle size ~100 nm) under high ionic strength conditions by reacting it with highly concentrated (up to 5 M) salt solutions. We explore different electrolyte compositions to elucidate the impact of different anions (NO3-, Cl-, ClO4-, SO42-, C2O42-, CO32-) on the stability of PuO2 NP in the acidic and alkaline pH regime. PuO2 NP aggregation and precipitation as function electrolyte concentration is tracked by a combination of liquid scintillation counting, dynamic light scattering for determination of particle size distributions, and zeta potentials as a proxy for particle charge. At acidic pH, electrolytes containing non-coordinating anions, such as NaNO3, NaCl, and NaClO4 mostly stabilize PuO2 NPs over a large electrolyte concentration range, showing only subtle differences in their reactivity. Other electrolyte anions show a more pronounced effect on the PuO2 NP stability: SO42-, binds directly to the particles’ surface, reverses the particle charge, and precipitates the PuO2 NPs efficiently even at intermediate sulfate concentrations (>0.1 M). In contrast, C2O42- is found to lead to high [Pu] in solution, in the milli-molar range, even at mildly acidic pH (~4). Thermodynamic modeling of the dissolved Pu concentrations using PHREEQC is unable to predict the observed [Pu] in the acidic pH regime, supporting the influence of colloids in maintaining elevated [Pu]. It is noteworthy that the current thermodynamic databases do not include constants for colloidal Pu phases and cannot accurately predict many of the high ionic strength solutions relevant to this work. The mechanisms and models responsible for these observations will need further investigation in the future. At high pH values (~12), PuO2 NPs exhibits classical sol-gel chemistry, meaning that upon destabilization of the colloidal sol, for example by addition of concentrated NaOH, highly porous and viscid PuO2 coagulates are formed that consist of a three-dimensional network likely held together by physical interactions. The PuO2 NP coagulate shows no significant reversibility of the aggregation when contacted with concentrated brines; however, PuO2 NPs can be efficiently resuspended in solution by addition of diluted electrolytes, alkaline solutions containing high amounts of carbonate, or simple addition of water. Especially carbonate is shown to stabilize PuO2 NPs in solution at high pH, characterized by stable colloidal suspensions that are resistant against sedimentation during centrifugation. Thermodynamic modeling of the carbonate system was able to predict an increasing dissolved Pu concentration with increasing carbonate concentration. However, the model was profoundly sensitive to the fixed redox potential and does not include any thermodynamic constants for colloidal Pu species.

Neumann, Julia↗

Latest Results from the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment based at Fermilab, IL, USA, that observes $\nu_\mu(\bar{\nu}_\mu) \to \nu_\mu(\bar{\nu}_\mu)$ disappearance and $\nu_\mu(\bar{\nu}_\mu) \to \nu_e(\bar{\nu}_e)$ appearance oscillations from a beam of neutrninos provided by the NuMI beamline at Fermilab. The experiment is made up of two functionally identical liquid scintillation detectors, both situated 14.6 mrad off-axis to the beam direction and made out of PVC extrusion cells arranged in alternating horizontal and vertical planes. The experiment is sensitive not only to standard three-flavor neutrino oscillations, but also to beyond standard model (BSM) searches such as sterile neutrino and non-standard interaction (NSI) of neutrinos with matter searches. The latest results from 3-flavor neutrino oscillation analysis, the NOvA-T2K joint analysis, searches for sterile neutrinos and non-standard interactions of neutrinos with matter, will be discussed here.

Choudhary, Brajesh [Delhi Tech. U.] (ORCID:0000000↗

Measurement of the Muon Flux at the Sanford Underground Research Facility with the LUX-ZEPLIN Dark Matter Detector

High-energy cosmic-ray muons reaching deep underground laboratories can cause events in detectors that mimic signals expected from dark matter particles, neutrinos, or rare decays. Knowledge of the muon flux and energy spectrum is important for evaluating the background rate caused by muons and their secondaries. In this paper, we report the measurement of the cosmic-ray muon flux in the Davis Campus of the Sanford Underground Research Facility with the LUX-ZEPLIN detector. Using 366.4~days of exposure, the muon rate through the detector was measured as $10.94\pm0.17_\textrm{stat.}~\textrm{day}^{-1}$ with energy thresholds of 20~MeV in the inner xenon detector and 8 MeV in the outer liquid scintillator detector. This rate corresponds to a muon flux of $(5.09\pm0.08_\textrm{stat.}\pm0.10_\textrm{sys.})\times10^{-9}~\textrm{cm}^{-2}\textrm{s}^{-1}$ in the Davis Cavern.

Akerib, D. S. [SLAC; Stanford U., Phys. Dept.; KIP↗

Optimizing Neutrino Flavor Conversion Measurements through Machine Learning

The phenomenon of neutrino flavor conversion whereby the flavor of a neutrino particle can change between its time of production and later detection was the first definitive evidence of physics beyond the Standard Model. Some of the oscillation parameters used to describe this conversion are not yet well measured, leaving important questions still open regarding flavor conversion both in vacuum and as neutrinos travel through matter. NOvA is a long-baseline neutrino oscillation experiment that uses Fermilab's predominantly $\nu_\mu$ NuMI beam. A 14 kton oil-based liquid scintillator far detector 810 km away is used to measure neutrino oscillation through the $\nu_\mu$ disappearance and $\nu_e$ appearance channels. Super-K is a 50 kton water Cherenkov detector, which measures the disappearance of $\nu_e$ produced during solar fusion. The high density environment of the sun decreases the $\nu_e$ survival probability at higher energies observable in Super-K compared to the vacuum-dominated oscillations at lower energies. However, the transition region is overshadowed by radioactive background in the detector. In both of these experiments, the separation of neutrino detection events from background and classification of neutrino flavor are crucial tasks that benefit from the introduction of machine learning. Chapter 1 gives an overview of neutrinos and the context under which flavor conversion is measured in this dissertation. Chapters 2-7 present the results of a Bayesian sampling approach for the latest NOvA 3-flavor oscillation analysis with $26.6 \times 10^{20}$ protons on target in neutrino mode and $12.5 \times 10^{20}$ in antineutrino mode collected over 10 years. Chapters 8-13 present the results of extending the Super-K solar analysis to lower energies during its fourth phase with 2970 days of livetime.

Yankelevich, Alejandro Jaime [UC, Irvine]↗

Optimizing Neutrino Flavor Conversion Measurements through Machine Learning

The phenomenon of neutrino flavor conversion whereby the flavor of a neutrino particle can change between its time of production and later detection was the first definitive evidence of physics beyond the Standard Model. Some of the oscillation parameters used to describe this conversion are not yet well measured, leaving important questions still open regarding flavor conversion both in vacuum and as neutrinos travel through matter. NOvA is a long-baseline neutrino oscillation experiment that uses Fermilab's predominantly $\nu_\mu$ NuMI beam. A 14 kton oil-based liquid scintillator far detector 810 km away is used to measure neutrino oscillation through the $\nu_\mu$ disappearance and $\nu_e$ appearance channels. Super-K is a 50 kton water Cherenkov detector, which measures the disappearance of $\nu_e$ produced during solar fusion. The high density environment of the sun decreases the $\nu_e$ survival probability at higher energies observable in Super-K compared to the vacuum-dominated oscillations at lower energies. However, the transition region is overshadowed by radioactive background in the detector. In both of these experiments, the separation of neutrino detection events from background and classification of neutrino flavor are crucial tasks that benefit from the introduction of machine learning. Chapter 1 gives an overview of neutrinos and the context under which flavor conversion is measured in this dissertation. Chapters 2-7 present the results of a Bayesian sampling approach for the latest NOvA 3-flavor oscillation analysis with $26.6 \times 10^{20}$ protons on target in neutrino mode and $12.5 \times 10^{20}$ in antineutrino mode collected over 10 years. Chapters 8-13 present the results of extending the Super-K solar analysis to lower energies during its fourth phase with 2970 days of livetime.

Yankelevich, Alejandro Jaime [UC, Irvine]↗

Optimizing Neutrino Flavor Conversion Measurements through Machine Learning

The phenomenon of neutrino flavor conversion whereby the flavor of a neutrino particle can change between its time of production and later detection was the first definitive evidence of physics beyond the Standard Model. Some of the oscillation parameters used to describe this conversion are not yet well measured, leaving important questions still open regarding flavor conversion both in vacuum and as neutrinos travel through matter. NOvA is a long-baseline neutrino oscillation experiment that uses Fermilab's predominantly $\nu_\mu$ NuMI beam. A 14 kton oil-based liquid scintillator far detector 810 km away is used to measure neutrino oscillation through the $\nu_\mu$ disappearance and $\nu_e$ appearance channels. Super-K is a 50 kton water Cherenkov detector, which measures the disappearance of $\nu_e$ produced during solar fusion. The high density environment of the sun decreases the $\nu_e$ survival probability at higher energies observable in Super-K compared to the vacuum-dominated oscillations at lower energies. However, the transition region is overshadowed by radioactive background in the detector. In both of these experiments, the separation of neutrino detection events from background and classification of neutrino flavor are crucial tasks that benefit from the introduction of machine learning. Chapter 1 gives an overview of neutrinos and the context under which flavor conversion is measured in this dissertation. Chapters 2-7 present the results of a Bayesian sampling approach for the latest NOvA 3-flavor oscillation analysis with $26.6 \times 10^{20}$ protons on target in neutrino mode and $12.5 \times 10^{20}$ in antineutrino mode collected over 10 years. Chapters 8-13 present the results of extending the Super-K solar analysis to lower energies during its fourth phase with 2970 days of livetime.

Yankelevich, Alejandro Jaime [UC, Irvine] (ORCID:0↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

A study of the scintillation light induced in liquid xenon by electrons and alpha particles

The time dependence and the intensity of the primary scintillation light in liquid Xe excited by Am-241 alpha particles and Bi-207 internal-conversion electrons were measured at different electric-field strengths. High-purity liquid Xe was used to fill a parallel-plate ionization chamber equipped with a CaF2 window coupled to a UV-sensitive photomultiplier tube. The effect of the specific ionization density on the scintillation light and the time correlation between the light signal and the charge signal is reported. It is demonstrated that the fast scintillation signal produced in liquid Xe by an ionizing particle provides an ideal trigger in a detector aiming at a complete three-dimensional event reconstruction with an excellent background rejection capability.

Aprile, Elena↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$\nu$NS Detection

The Scintillating Bubble Chamber (SBC) Collaboration is developing liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering (CE$\nu$NS) of low-energy (MeV-scale) neutrinos. The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This device will calibrate the background discrimination power and sensitivity of superheated argon to nuclear recoils at energies down to 100 eV. A second functionally-identical detector with a focus on radiopure construction is being built for SBC's first dark matter search at SNOLAB. The projected spin-independent sensitivity of this search is approximately $10^{-43}$ cm$^2$ at 1 GeV$/c^2$ dark matter particle mass. The scalability and background discrimination power of the liquid-noble bubble chamber make this technique a compelling candidate for future dark matter searches to the solar neutrino fog at 1 GeV$/c^2$ particle mass (requiring a $\sim$ton-year exposure with non-neutrino backgrounds sub-dominant to the solar CE$\nu$NS signal) and for high-statistics CE$\nu$NS studies at nuclear reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics Potential of a Future Large n Detector in Korea

The demand for underground labs for neutrino and rare event search experiments has been increasing over the last few decades. Yemilab, constructed in October 2022, is the first deep (1~km) underground lab dedicated to science in Korea, where a large cylindrical cavern (D: 20~m, H: 20~m) was excavated in addition to the main caverns and halls. The large cavern could be utilized for a low background neutrino experiment by a liquid scintillator-based detector (LSC) where a 2.26 kiloton LS target would be filled.It's timely to have such a large but ultra-pure LS detector after the shutdown of the Borexino experiment so that solar neutrinos can be measured much more precisely. Interesting BSM physics searches can be also pursued with this detector when it's combined with an electron linac, a proton cyclotron (IsoDAR source), or a radioactive source. This talk discusses the concept of a candidate detector and the physics potential of a large liquid scintillator detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of scintillation light dependence on Liquid Argon purity in the ICARUS detector

Previous studies have investigated the correlation between impurities concentration in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield.These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N$_{2}$), can influence LAr scintillation properties without necessarily affecting electron lifetime.Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetime in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS detector consists of two cryostats that have shown different behaviors in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats and presents the methodology used to extract scintillation timing characteristics and their correlation with LAr purity.

Saia, C. [Catania Astrophys. Observ.] (ORCID:00090↗