Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Liquid-Hydrogen-Cooled 450-hp Electric Motor Test Stand Being Developed

With growing concerns about global warming, there is a need to develop pollution-free aircraft. One approach is to use hydrogen-fueled airc raft that use fuel cells or turbogenerators to produce electric power to drive the electric motors that turn the aircraft#s propulsive fan s. Hydrogen fuel would be carried as a liquid, stored at its boiling point of 20.5 K (-422.5 ?F). Conventional electric motors, however, are too heavy to use on an aircraft. We need to develop high-power, lig htweight electric motors (high-powerdensity motors).

Kascak, Albert F.↗

Fire and Ice - Safety, Comfort, and Getting the Firefighters' Job Done

Daily life for firefighters consists of working with life-threatening hazards in hostile environments. A major hazard is excessive ambient heat. New hazards have arisen from protective gear that was intended to increase survival time of firefighters while finding and rescuing victims. The insulation is so good now that a firefighter's metabolic heat buildup cannot escape. This forces body core temperatures to life threatening levels in about 20 minutes of moderate activity. Using NASA space suit technology, Oceaneering Space Systems developed a liquid cooling garment prototype that will remove up to 250 watts of metabolic heat. After testing and certification as an approved accessory for firefighter use, this garment will be available for use by any individual encapsulated in protective clothing. This demonstration will present a high surface area circulated liquid cooling garment displayed on a mannequin and available for attendees to try on to experience the effects of active cooling.

Foley, Tico↗

datacenterCoolingModel

ExaDigiT is a framework for developing comprehensive digital twins of liquid-cooled supercomputers, which has three main modules: (1) a python-based Resource Allocator and Power Simulator (RAPS), (2) a Modelica-based Thermo-Fluidic cooling model, and (3) a C++-based augmented reality model built on Unreal Engine 5. The Modelica-based cooling model is primarily built-on the open-source Transient Simulation Framework of Reconfigurable Models (TRANSFORM) library and the open-source autocsm library. The library follows the templating architecture developed in the TRANSFORM and the autocsm libraries. This tool can be easily extended to model other Frontier-like liquid cooled supercomputers.

Kumar, Vineet [Oak Ridge National Laboratory (ORNL↗

Developing a Hybrid Space Suit Simulator as a Research Tool for Assessing Extravehicular Activity Relevant Workload

Suited testing time is limited and hard to come by, expensive, and requires a whole team to operate and monitor the suit; however, pressurized spacesuits are not always necessary for initial developmental efforts or assessment of informatics. The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA Johnson Space Center (JSC) is developing a Hybrid Space Suit Simulator (HS3) to support characterization of human performance during planetary surface exploration analogs. The primary goal of HS3 is to create a low cost, modular, and unpressurized suit simulator for use as a research tool which provides relevant physical and cognitive workload approximations with EVA-like immersion during planetary extravehicular activity (EVA) simulations. HS3 consists of a soft suit, communication, thermal control, gloves, boots, helmet, and integrated bioinformatics/sensors. The modular design of HS3 allows it to be modified to support test objectives as needed. HS3 enables H-3PO and NASA to complete critical human health and performance testing to address open risks and knowledge gaps in a timely, repeatable, and controlled manner. Four engineering runs were completed with HS3 as a baseline for capability. General workload was assessed while traversing on a passive treadmill and conducting geology tasks. Liquid cooling temperature, suit temperature, and metabolic rates were collected during one extended three-hour engineering run. For the duration of the engineering run the suit temperature was 26.6 ± 1.58 °C while suit humidity was 53.7 ± 5.11 %. Helmet temperature was higher than suit temperature at 27.8 ± 1.58 °C. Helmet humidity was lower than average suit humidity at 50.12 ± 11.3 °C. The liquid cooling temperature remained stable at 22.4 ± 1.62 °C. Resting metabolic rate was 597 ± 88 BTU/hr while metabolic rate increased during traverse tasks at 1500 ± 319 BTU/hr and geology tasks at 921 ± 129 BTU/hr. Following the engineering runs, a characterization study will be conducted. The subjects will perform EVA-like scenarios in both a shirtsleeve only and donned HS3, consisting of EVA task circuit focused on traversing, geological rock sampling, and task board manipulation. The characterization study will provide data capability for implementing HS3 in analog EVA testing environments.

Monica Hew↗

Composite with In Situ Plenums

A document describes a high-performance thermal distribution panel (TDP) concept using high-conductivity (greater than 800 W/mK) macro composite skin with in situ heat pipes. The processing technologies proposed to build such a panel result in a one-piece, inseparable assembly with high conductance in both the X and Y planes. The TDP configuration can also be used to produce panels with high structural stiffness. The one-piece construction of the TDP eliminates the thermal interface between the cooling plenums and the heat spreader base, and obviates the need for bulky mounting flanges and thick heat spreaders used on baseline designs. The conductivity of the TDP can be configured to exceed 800 W/mK with a mass density below 2.5 grams per cubic centimeter. This material can provide efficient conductive heat transfer between the in situ heat plenums, permitting the use of thinner panel thicknesses. The plenums may be used as heat pipes, loop heat pipes, or liquid cooling channels. The panel technology used in the TDP is a macro-composite comprised of aluminum-encapsulated annealed pyrolytic graphite (APG). APG is highly aligned crystalline graphite with an in-plane thermal conductivity of 1,700 W/mK. APG has low shear strength and does not constrain the encapsulating material. The proposed concept has no thermal interfaces between the heat pipes and the spreader plate, further improving the overall conductance of the system. The in situ plenums can also be used for liquid cooling applications. The process can be used to fabricate structural panels by adding a second thin sheet.

Montesano, Mark↗

Biomedical Support of U.S. Extravehicular Activity

The world's first extravehicular activity (EVA) was performed by A. A. Leonov on March 18, 1965 during the Russian Voskhod-2 mission. The first US EVA was executed by Gemini IV astronaut Ed White on June 3, 1965, with an umbilical tether that included communications and an oxygen supply. A hand-held maneuvering unit (HHMU) also was used to test maneuverability during the brief EVA; however the somewhat stiff umbilical limited controlled movement. That constraint, plus difficulty returning through the vehicle hatch, highlighted the need for increased thermal control and improved EVA ergonomics. Clearly, requirements for a useful EVA were interrelated with the vehicle design. The early Gemini EVAs generated requirements for suits providing micro-meteor protection, adequate visual field and eye protection from solar visual and infrared radiation, gloves optimized for dexterity while pressurized, and thermal systems capable of protecting the astronaut while rejecting metabolic heat during high workloads. Subsequent Gemini EVAs built upon this early experience and included development of a portable environmental control and life support systems (ECLSS) and an astronaut maneuvering unit. The ECLSS provided a pressure vessel and controller with functional control over suit pressure, oxygen flow, carbon dioxide removal, humidity, and temperature control. Gemini EVA experience also identified the usefulness of underwater neutral buoyancy and altitude chamber task training, and the importance of developing reliable task timelines. Improved thermal management and carbon dioxide control also were required for high workload tasks. With the Apollo project, EVA activity was primarily on the lunar surface; and suit durability, integrated liquid cooling garments, and low suit operating pressures (3.75 pounds per square inch absolute [psia] or 25.8 kilopascal [kPa],) were required to facilitate longer EVAs with ambulation and significant physical workloads with average metabolic rates of 1000 BTU/hr and peaks of up to 2200 BTU/hr. Mobility was further augmented with the Lunar Roving Vehicle. The Apollo extravehicular mobility unit (EMU) was made up of over 15 components, ranging from a biomedical belt for capturing and transmitting biomedical data, urine and fecal containment systems, a liquid cooling garment, communications cap, a modular portable life support system (PLSS), a boot system, thermal overgloves, and a bubble helmet with eye protection. Apollo lunar astronauts performed successful EVAs on the lunar surface from a 5 psia (34.4 kPa) 100% oxygen environment in the Lunar Lander. A maximum of three EVAs were performed on any mission. For Skylab a modified A7LB suit, used for Apollo 15, was selected. The Skylab astronaut life support assembly (ALSA) provided umbilical support through the life support umbilical (LSU) and used open loop oxygen flow, rather than closed-loop as in Apollo missions. Thermal control was provided by liquid water circulated by spacecraft pumps and electrical power also was provided from the spacecraft via the umbilical. The cabin atmosphere of 5 psia (34.4 kPa), 70% oxygen, provided a normoxic atmosphere and because of the very low nitrogen partial pressures, no special protocols were required to protect against decompression sickness (DCS) as was the case with the Apollo spacecraft with a 5 psi, 100% oxygen environment.

Gernhardt, Michael L.↗

Century: Zap Energy’s 100-kW-Scale Repetitive Sheared-Flow-Stabilized Z -Pinch System with Liquid Metal Cooling

Zap Energy is developing the sheared-flow-stabilized (SFS) Z-pinch concept for commercial applications. The SFS Z pinch relies on plasma self-organization, in the sense that plasma dynamics play a critical role in confinement. Using plasma axial current for confinement and compression eliminates the need for external confinement or heating technologies. This compact magnetic confinement technology could, in turn, provide the basis for a cost-effective deuterium-tritium fusion power plant. In addition to a robust experimental program pushing plasma performance towards breakeven conditions, Zap Energy has parallel programs developing power handling systems suitable for future power plants. Technologies under development include high average-power repetitive pulsed power, high duty-cycle cathodes, and liquid metal wall systems. Century is the name of Zap Energy’s first effort to integrate these three components into an operational system capable of firing non-reacting hydrogen SFS Z-pinch plasmas into a liquid-metal-lined container at sustained repetition rates on the order of 0.1 Hz. Here, the pulsed power driver and liquid metal heat exchanger are both designed to sustain input powers of 100 kW. Construction and initial operations with an interim ~10 kW liquid metal heat exchanger are described.

Century↗

Efficient Refrigerated Display Cases - Can They Flex Their Power? Preprint

Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Heat-transfer tests of aqueous ethylene glycol solutions in an electrically heated tube

As part of an investigation of the cooling characteristics of liquid-cooled engines, tests were conducted with an electrically heated single-tube heat exchanger to determine the heat-transfer characteristics of an-e-2 ethylene glycol and other ethylene glycol-water mixtures. Similar tests were conducted with water and commercial butanol (n-butyl alcohol) for check purposes. The results of tests conducted at an approximately constant liquid-flow rate of 0.67 pound per second (Reynolds number, 14,500 to 112,500) indicate that at an average liquid temperature 200 degrees f, the heat-transfer coefficients obtained using water, nominal (by volume) 30 percent-70 percent and 70 percent-30 percent glycol-water mixtures are approximately 3.8, 2.8, and 1.4 times higher, respectively, than the heat-transfer coefficients obtained using an-e-2 ethylene glycol.

Bernardo, Everett↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

Machine Learning Analysis of Temperature-Strain Relationships for Structural Health Monitoring of Pipes: Self-powered wireless sensor system for health monitoring of liquid-sodium cooled fast reactors

This report presents machine learning (ML) analysis of temperature-strain relationships for structural health monitoring of nuclear reactor stainless steel (SS) pipes with the strain gauge sensor directly printed on the pipe with a 3D conformal aerosol jet printer. We investigate correlations for two sensor pairs installed on the same SS304 pipe: commercial K-type thermocouple with a printed gold strain gauge (TC3-SG3), and commercial K-type thermocouple with commercial Kyowa strain gauge (TC0-SG0). The temperature ranges for the sensor pairs TC0-SG0 and TC3-SG3 are 20.00°C to 266.37°C and 39.95°C to 219.28°C respectively. ML algorithms in this study include Linear Regression (baseline method), Ridge Regression, Lasso Regression, and Gradient Boosting. Performance evaluation metrics include Root Mean Square Error (RMSE), Mean Square Error (MSE), Mean Absolute Error (MAE), R 2 Score, and Explained Variance. Using advanced feature engineering techniques, we extracted 27 temperature-based features and 30 strategic inclusion features. The best performance was obtained with the Gradient Boosting method, which achieves prediction accuracy of R 2 = 0.9999 and RMSE = 7.69 μStrain for TC0-SG0, and R 2 = 0.9998 and RMSE = 18.03 μStrain for TC3-SG3. While the temperature-strain correlations are weaker for the gauge directly printed on the pipe than for the commercial strain gauge, deployment-ready performance exceeding industry standards is achieved for both sensor pairs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Liquid-helium-cooled Michelson interferometer

Interferometer serves as a rocket-flight spectrometer for examination of the far infrared emission spectra of astronomical objects. The double beam interferometer is readily adapted to make spectral scans and for use as a detector of discrete line emissions.

Augason, G. C.↗