Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Gait Characterization and Analysis of Hereditary Amyloidosis Associated with Transthyretin Patients: A Case Series

Hereditary amyloidosis associated with transthyretin (ATTRv), is a rare autosomal dominant disease characterized by length-dependent symmetric polyneuropathy that has gait impairment as one of its consequences. The gait pattern of V30M ATTRv amyloidosis patients has been described as similar to that of diabetic neuropathy, associated with steppage, but has never been quantitatively characterized. In this study we aim to characterize the gait pattern of patients with V30M ATTRv amyloidosis, thus providing information for a better understanding and potential for supporting diagnosis and disease progression evaluation. We present a case series in which we conducted two gait analyses, 18 months apart, of five V30M ATTRv amyloidosis patients using a 12-camera, marker based, optical system as well as six force platforms. Linear kinematics, ground reaction forces, and angular kinematics results are analyzed for all patients. All patients, except one, showed a delayed toe-off in the second assessment, as well as excessive pelvic rotation, hip extension and external transverse rotation and knee flexion (in stance and swing phases), along with reduced vertical and mediolateral ground reaction forces. The described gait anomalies are not clinically quantified; thus, gait analysis may contribute to the assessment of possible disease progression along with the clinical evaluation.

Vilas-Boas, Maria do Carmo (ORCID:000000025012789X↗

Information transfer as a framework for optimized phase imaging

In order to efficiently image a non-absorbing sample (a phase object), dedicated phase contrast optics are required. Typically, these optics are designed with the assumption that the sample is weakly scattering, implying a linear relation between a sample’s phase and its transmission function. In the strongly scattering, nonlinear case, the standard optics are ineffective, and the transfer functions used to characterize them are uninformative. We use the Fisher information (FI) to assess the efficiency of various phase imaging schemes and to calculate an information transfer function (ITF). We show that a generalized version of Zernike phase contrast is efficient given sufficient prior knowledge of the sample. We show that with no prior knowledge, a random sensing measurement yields a significant fraction of the available information. Finally, we introduce a generalized approach to common path interferometry that can be optimized to prioritize sensitivity to particular sample features. Each of these measurements can be performed using Fourier lenses and phase masks.

Koppell, Stewart↗

Color Transformations of Photometric Measurements of Galaxies in Optical and Near-infrared Wide-field Imaging Surveys*

Abstract Over the past 2 decades, wide-field photometric surveys in optical and infrared domains reached a nearly all-sky coverage thanks to numerous observational facilities operating in both hemispheres. However, subtle differences among exact realizations of Johnson and SDSS photometric systems require one to convert photometric measurements into the same system prior to analysis of composite data sets originating from multiple surveys. It turns out that the published photometric transformations lead to substantial biases when applied to integrated photometry of galaxies from the corresponding catalogs. Here we present photometric transformations based on piece-wise linear approximations of integrated photometry of galaxies in the optical surveys SDSS, DECaLS, BASS, MzLS, DES, DELVE, KiDS, VST ATLAS, and the near-infrared surveys UKIDSS, UHS, VHS, and VIKING. We validate our transformations by constructing k -corrected color–magnitude diagrams of non-active galaxies and measuring the position and tightness of the “red sequence.” We also provide transformations for aperture magnitudes and show how they are affected by the image quality difference among the surveys. We present the implementation of the derived transformations in python and idl and also a web-based color transformation calculator for galaxies. By comparing DECaLS and DES, we identified systematic issues in DECaLS photometry for extended galaxies, which we attribute to the photometric software package used by DECaLS. As an application of our method, we compiled two multi-wavelength photometric catalogs for over 200,000 low- and intermediate-redshift galaxies originating from CfA FAST and Hectospec spectral archives.

Astronomy & Astrophysics↗

Dynamic wavelength control of laser pulse profiles at picosecond to nanosecond timescales

We report on a novel combined laser pulse shaping and dynamic wavelength encoding capability based on a simple architecture implementing direct space to time mapping. There are several potential applications that can be enabled by the ability to control the instantaneous intensity or wavelength of an optical waveform on a picosecond-to-nanosecond timescale. To our knowledge, no known methods can access this temporal regime with a practical architecture. Here, we demonstrate an extension of the Space–Time Induced Linearly Encoded Transcription for Temporal Optimization (STILETTO) technique that can generate optical waveforms with a programmable instantaneous wavelength vs. time. We experimentally demonstrate the technique by generating self-gated spectrograms and show that it can encode dynamic wavelength vs time profiles at timescales not achievable by any other known method.

47 OTHER INSTRUMENTATION↗

Arrays of Si vacancies in 4 H -SiC produced by focused Li ion beam implantation

Point defects in SiC are an attractive platform for quantum information and sensing applications because they provide relatively long spin coherence times, optical spin initialization, and spin-dependent fluorescence readout in a fabrication-friendly semiconductor. The ability to precisely place these defects at the optimal location in a host material with nano-scale accuracy is desirable for integration of these quantum systems with traditional electronic and photonic structures. Here, we demonstrate the precise spatial patterning of arrays of silicon vacancy (${V}_{Si}$) emitters in an epitaxial 4H -SiC (0001) layer through mask-less focused ion beam implantation of Li + . We characterize these arrays with high-resolution scanning confocal fluorescence microscopy on the Si-face, observing sharp emission lines primarily coming from the ${V1}^{{\prime}}$ zero-phonon line (ZPL). The implantation dose is varied over 3 orders of magnitude, leading to ${V}_{Si}$ densities from a few per implantation spot to thousands per spot, with a linear dependence between ZPL emission and implantation dose. Optically-detected magnetic resonance (ODMR) is also performed, confirming the presence of V2 ${V}_{Si}$. Our investigation reveals scalable and reproducible defect generation.

36 MATERIALS SCIENCE↗

Linear Modelling from Betatron Phase Measurements at the Fermilab Recycler NOvA ring

Utilizing the measurement of coherent betatron oscillation phase has emerged as fast and precise approach for identifying and rectifying errors in implementing a desired lattice in CESR (Cornell Electron Storage Ring). One key advantage of betatron phase measurement over β measurement is its sensitivity to phase variations between widely separated points. This methodology has been successfully implemented for the Recycler NOvA Ring at Fermilab, with the adoption of TAO (Tool for Accelerator Optics) developed by Cornell University. By employing this technique, a linear model of the Recycler NOvA ring is established, enabling the correction of quadrupole errors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exactly unitary discrete representations of the metaplectic transform for linear-time algorithms

The metaplectic transform (MT), a generalization of the Fourier transform sometimes called the linear canonical transform, is a tool used ubiquitously in modern optics, for example, when calculating the transformations of light beams in paraxial optical systems. The MT is also an essential ingredient of the geometrical-optics modeling of caustics that we recently proposed. In particular, this application relies on the near-identity MT (NIMT); however, the NIMT approximation used so far is not exactly unitary and leads to numerical instability. Here, we develop a discrete MT that is exactly unitary, and approximate it to obtain a discrete NIMT that is also unitary and can be computed in linear time. We prove that the discrete NIMT converges to the discrete MT when iterated, thereby allowing the NIMT to compute MTs that are not necessarily near-identity. Finally, we then demonstrate the new algorithms with a series of examples.

47 OTHER INSTRUMENTATION↗

Nonlinear X-ray Optics

Novel X-ray free-electron lasers (XFELs) are capable of producing radiation with unprecedented properties. Specifically, their ultrashort coherent X-ray pulses can generate extreme peak intensities where ordinary rules of light-matter interaction may no longer apply, and nonlinear processes start to become important. XFELs have made it possible to observe some of the most important coherent non-sequential nonlinearities, including X-ray-optical sum frequency generation (SFG), X-ray second harmonic generation (XSHG), two-photon absorption (TPA) and nonlinear two-photon Compton scattering (2PCS). In particular, the 2PCS experiment has led to unexpected results, namely the observation of a substantial anomalous red shift in the energy of photons generated by nonlinear two-photon X-ray Compton scattering in beryllium. The energy shift is in addition to the predicted nonlinear Compton shift and was neither expected from extrapolations from linear X-ray interactions nor from nonlinear effects at optical wavelengths. Our results suggest a novel nonlinear scattering mechanism that can only be observed at high fields at X-ray wavelengths, where the photon energy is a significant fraction of the electron rest mass (and thus a significant momentum transfer to the electron occurs during the scattering) and where the interaction is not dominated by the quiver motion of the electron in the field (ponderomotive potential) as is usually the case at longer (optical) wavelengths. The goal of this research project was the investigation of fundamental nonlinear X-ray-matter interactions. As these processes are typically weak, part of this research is the exploration of more efficient nonlinear X-ray processes by studying novel mechanisms including solid-state effects, the assistance of optical radiation and novel phase-matching techniques. These experiments require extremely large X-ray field strengths, such as produced by XFELs. Nonlinear X-ray effects can lead to important applications in many research fields. For example, it could lead to instantaneous plasma diagnostics for materials in extreme conditions, as a method for combining atomic-scale structural sensitivity with chemical specificity, or as a probe of electron dynamics in solids on the attosecond (1 as = 10 -18 s) time- and Ångstrom (10 -10 m) length scales. In addition, a detailed understanding of nonlinear X-ray matter interactions is crucial for understanding and extending the limits of structural determination at high intensity such as in serial femto-crystallography. The results could have a profound impact on advanced XFEL light sources such as the LCLS-II.

47 OTHER INSTRUMENTATION↗

Broadband 2DES detection of vibrational coherence in the S x state of canthaxanthin

The nonadiabatic mechanism that mediates nonradiative decay of the bright S 2 state to the dark S 1 state of carotenoids involves population of a bridging intermediate state, S x , in several examples. The nature of S x remains to be determined definitively, but it has been recently suggested that S x corresponds to conformationally distorted molecules evolving along out-of-plane coordinates of the isoprenoid backbone near a low barrier between planar and distorted conformations on the S 2 potential surface. Here, the electronic and vibrational dynamics accompanying the formation of S x in toluene solutions of the ketocarotenoid canthaxanthin (CAN) are characterized with broadband two-dimensional electronic spectroscopy (2DES) with 7.8 fs excitation pulses and detection of the linear polarization components of the third-order nonlinear optical signal. A stimulated-emission cross peak in the 2DES spectrum accompanies the formation of S x in <20 fs following excitation of the main absorption band. S x is prepared instantaneously, however, with excitation of hot-band transitions associated with distorted conformations of CAN’s isoprenoid backbone in the low frequency onset of the main absorption band. Vibrational coherence oscillation maps and modulated anisotropy transients show that S x undergoes displacements from the Franck–Condon S 2 state along out-of-plane coordinates as it passes to the S 1 state. The results are consistent with the conclusion that CAN’s carbonyl-substituted β-ionone rings impart an intramolecular charge-transfer character that frictionally slows the passage from S x to S 1 compared to carotenoids lacking carbonyl substitution. Despite the longer lifetime, the S 1 state of CAN is formed with retention of vibrational coherence after passing through a conical intersection seam with the S x state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural complexity in the f -block: small deviations of the complexation of lanthanides by O,Oʹ -diethylmonothiophosphate

Dithiophosphinic acids undergo radiolytic degradation during the extraction of actinides in used nuclear fuel. These will degrade into monothiophosphinic acids and then to phosphinic acids. To elucidate how the complexes that are formed during these radioactive separations change as the ligand degrades, the mixed donor ligand O,O′- diethylmonothiophosphate is chosen as an analog for the monothiophosphinic intermediate. Herein, the monothiophosphate complexes Ln 2 (OPS(OEt) 2 ) 6 (H 2 O) 8 (Ln = La) (La 2 L 6 H 2 O), Ln 2 (OPS(OEt) 2 ) 6 (EtOH) 4 (Ln = La) (La 2 L 6 EtOH), K 2 [Ln(OPS(OEt) 2 ) 5 (H 2 O) 2 ]·H 2 O·CH 2 Cl 2 , (Ln = Ce) (CeL 5 -α), K 2 [Ln(OPS(OEt) 2 ) 5 (H 2 O) 2 ]·H 2 O·CH 2 Cl 2 , (Ln = Pr) (PrL 5 -β), K[Ln(OPS(OEt) 2 ) 4 (H 2 O) 3 ], (Ln = Pr, Sm-Er) (ML 4 ), and K 3 [Ln(OPS(OEt) 2 ) 6 ], (Ln = Dy) (DyL 6 ) were synthesized and characterized using single-crystal X-ray diffraction and optical spectroscopy. Although the lanthanides contract in a nearly linear fashion, the structural changes observed as the f-block is traversed in these compounds are not necessarily a hard line but more so a blend of different structure types possible for each f-element. Furthermore, comparison of the Ln−O bond lengths shows a nearly linear contraction, but the Ln−S bond lengths do not monotonically decrease because of the hard Lewis acidity of the Ln 3+ cations.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cavity molecular dynamics simulations of vibrational polariton-enhanced molecular nonlinear absorption

We report recent experiments have observed that the chemical and photophysical properties of molecules can be modified inside an optical Fabry– Pérot microcavity under collective vibrational strong coupling (VSC) conditions, and such modification is currently not well understood by theory. In an effort to understand the origin of such cavity-induced phenomena, some recent studies have focused on the effect of the cavity environment on the nonlinear optical response of the molecular subsystem. Here, we use a recently proposed protocol for classical cavity molecular dynamics simulations to numerically investigate the linear and the nonlinear response of liquid carbon dioxide under such VSC conditions following an optical pulse excitation. We find that applying a strong pulse of excitation to the lower hybrid light–matter state, i.e., the lower polariton (LP), can lead to an overall molecular nonlinear absorption that is enhanced by up to two orders of magnitude relative to the excitation outside the cavity. This polariton-enhanced multiphoton absorption also causes an ultrashort LP lifetime (0.2 ps) under strong illumination. Unlike usual polariton relaxation processes—whereby polaritonic energy transfers directly to the manifold of singly excited vibrational dark states—under the present mechanism, the LP transfers energy directly to the manifold of higher vibrationally excited dark states; these highly excited dark states subsequently relax to the manifold of singly excited states with a lifetime of tens of ps. Because the present mechanism is generic in nature, we expect these numerical predictions to be experimentally observed in different molecular systems and in cavities with different volumes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Second Linear Response Theory and the Analytic Calculation of Excited-State Properties

We present a method based on second linear response time-dependent density func- tional theory (TDDFT) to calculate permanent and transition multipoles of excited states, which are required to compute excited-state absorption/emission spectra, multi- photon optical processes, among others. In previous work, we examined computations based on second linear response theory in which linear response TDDFT was employed twice. In contrast, the present methodology only requires information from a single linear response calculation to compute the excited-state properties. These are eval- uated analytically through various algebraic operations involving electron repulsion integrals and excitation vectors. The present derivation focuses on full many-body wave functions instead of single orbitals, as in our previous approach. Here, we test the proposed method by applying it to several diatomic and triatomic molecules. This shows that the computed excited-state dipoles are consistent with respect to reference equation-of-motion coupled cluster calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

To image, or not to image: class-specific diffractive cameras with all-optical erasure of undesired objects

Abstract Privacy protection is a growing concern in the digital era, with machine vision techniques widely used throughout public and private settings. Existing methods address this growing problem by, e.g., encrypting camera images or obscuring/blurring the imaged information through digital algorithms. Here, we demonstrate a camera design that performs class-specific imaging of target objects with instantaneous all-optical erasure of other classes of objects. This diffractive camera consists of transmissive surfaces structured using deep learning to perform selective imaging of target classes of objects positioned at its input field-of-view. After their fabrication, the thin diffractive layers collectively perform optical mode filtering to accurately form images of the objects that belong to a target data class or group of classes, while instantaneously erasing objects of the other data classes at the output field-of-view. Using the same framework, we also demonstrate the design of class-specific permutation and class-specific linear transformation cameras, where the objects of a target data class are pixel-wise permuted or linearly transformed following an arbitrarily selected transformation matrix for all-optical class-specific encryption, while the other classes of objects are irreversibly erased from the output image. The success of class-specific diffractive cameras was experimentally demonstrated using terahertz (THz) waves and 3D-printed diffractive layers that selectively imaged only one class of the MNIST handwritten digit dataset, all-optically erasing the other handwritten digits. This diffractive camera design can be scaled to different parts of the electromagnetic spectrum, including, e.g., the visible and infrared wavelengths, to provide transformative opportunities for privacy-preserving digital cameras and task-specific data-efficient imaging.

47 OTHER INSTRUMENTATION↗

Quantum Non-Equilibrium Dynamics Prediction of Electronic Transport Coefficients in Non-Linear Regimes

The goal of this work was to develop unique LLNL capabilities for the computational prediction of electrical, optical and thermal transport properties from quantum simulations. Using a recently developed theory of microscopic quantum transport, we were able to model compressed metallic hydrogen and it’s non-linear and out-of-equilibrium contributions in electrical and thermal transport. This theory was implemented in the open-source, real-space time-dependent density functional theory code Octopus. This model is general and widely applicable to high energy density systems that are important to LLNL and NNSA mission areas.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast valley polarization in bilayer graphene

We study theoretically the interaction of a bilayer graphene with a circularly polarized ultrafast optical pulse of a single oscillation at an oblique incidence. The normal component of the pulse breaks the inversion symmetry of the system and opens up a dynamical bandgap due to which a valley-selective population of the conduction band becomes sensitive to the angle of incident of the pulse. We show that the magnitude of the valley polarization can be controlled by the angle of incidence, the amplitude, and the angle of in-plane polarization of the chiral optical pulse. Subsequently, a sequence of a circularly polarized pulse followed by a linearly polarized femtosecond-long pulse can be used to control and probe the valley polarization created by the preceding pulse. Our protocol provides a favorable platform to design ultrafast all-optical valleytronic information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of the pairwise kinematic Sunyaev-Zel’dovich effect and pairwise velocity with DESI DR1 galaxies and ACT DR6 and Planck CMB data

We present a 9.3⁢𝜎 detection of the pairwise kinematic Sunyaev-Zel’dovich (kSZ) effect by combining a sample of 913,286 Luminous Red Galaxies (LRGs) from the Dark Energy Spectroscopic Instrument Data Release 1 (DESI DR1) catalog and coadded Atacama Cosmology Telescope (ACT DR6) and Planck cosmic microwave background (CMB) temperature maps. This represents the highest-significance pairwise kSZ measurement to date. The analysis uses three ACT CMB temperature maps: coadded 150 GHz, total frequency maps, and a component separated Internal Linear Combination (ILC) map, all of which cover 19,000 square degrees of the sky from Advanced ACTPol observations conducted between 2017 and 2022. Comparison of the results of these three maps serves as a consistency check for potential foreground contamination that may depend on the observation frequency. An estimate of the best-fit mass-averaged optical depth is obtained by comparing the pairwise kSZ curve with the linear theory prediction of the pairwise velocity under the best-fit Planck cosmology and is compared with predictions from simulations. This estimate serves as a reference point for future comparisons with thermal SZ–derived optical depth measurements for the same DESI cluster samples, which will be presented in a companion paper. Finally, we employ a machine learning approach, trained on simulations to estimate the optical depth for 456,803 DESI LRG-identified clusters within the simulated mass range ( ≳ 10 13 ⁢𝑀 ⊙ ). These are combined with the measured kSZ signal to infer the individual cluster peculiar velocities, providing the opportunity to constrain the behavior of gravity and the dark sector over a range of cosmic scales and epochs.

Gong, Yulin [Cornell University] (ORCID:0000000346↗

Cosmological Constraints from Combining Photometric Galaxy Surveys and Gravitational Wave Observatories

Spatial variations in survey properties due to selection effects generate substantial systematic errors in large-scale structure measurements in optical galaxy surveys on very large scales. On such scales, the statistical sensitivity of optical surveys is also limited by their finite sky coverage. By contrast, gravitational wave (GW) sources appear to be relatively free of these issues, provided the angular sensitivity of GW experiments can be accurately characterized. We quantify the expected cosmological information gain from combining the forecast LSST 3$\times$2pt analysis (combination of three 2-point correlations of galaxy density and weak lensing shear fields) with the large-scale auto-correlation of GW sources from proposed next-generation GW experiments. We find that in $\Lambda$CDM and $w$CDM models, there is no significant improvement in cosmological constraints from combining GW with LSST 3$\times$2pt over LSST alone, due to the large shot noise for the former; however, this combination does enable a $\sim6\%$ constraint on the linear galaxy bias of GW sources. More interestingly, the optical-GW data combination provides tight constraints on models with primordial non-Gaussianity (PNG), due to the predicted scale-dependent bias in PNG models on large scales. Assuming that the largest angular scales that LSST will probe are comparable to those in Stage III surveys ($\ell_{\rm min}\sim50$), the inclusion of next-generation GW measurements could improve constraints on the PNG parameter $f_{\rm NL}$ by up to a factor of $\simeq6.6$ compared to LSST alone, yielding $\sigma(f_{\rm NL})=8.5$. These results assume the expected capability of a network of Einstein Telescope-like GW observatories, with a detection rate of $10^6$ events/year. We investigate the sensitivity of our results to different assumptions about future GW detectors as well as different LSST analysis choices.

79 ASTRONOMY AND ASTROPHYSICS↗