Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Compact X-ray Light Source Workshop Report

This report is the result of a workshop held in September 2011 that examined the utility of a compact x-ray light source (CXLS) in addressing many scientific challenges critical to advancing energy science and technology. The U.S. Department of Energy (DOE) and National Academy of Sciences (NAS) have repeatedly described the need for advanced instruments that “predict, control, and design the components of energetic processes and environmental balance,” most notably in biological, chemical, environmental, and materials science. In numerous DOE and NAS reports, direct molecular-scale imaging and timedependent studies are seen as a powerful means to develop an atomistic-level understanding of scientific issues associated with current and future energy and environmental needs, including energy production and storage from both fossil-based and fossil-free sources and cleanup of government and industrial sites worldwide.

chemical imaging↗

High efficiency light source using solid-state emitter and down-conversion material

A light emitting apparatus includes a source of light for emitting light; a down conversion material receiving the emitted light, and converting the emitted light into transmitted light and backward transmitted light; and an optic device configured to receive the backward transmitted light and transfer the backward transmitted light outside of the optic device. The source of light is a semiconductor light emitting diode, a laser diode (LD), or a resonant cavity light emitting diode (RCLED). The down conversion material includes one of phosphor or other material for absorbing light in one spectral region and emitting light in another spectral region. The optic device, or lens, includes light transmissive material.

Narendran, Nadarajah↗

Nonclassical Light Sources Based on Selectively Positioned Deterministic Microlens Structures and (111) In(Ga)As Quantum Dots

The results of investigations of the optical characteristics of nonclassical light sources based on selectively positioned microlens structures and single (111) In(Ga)As quantum dots grown on a (111) BGaAs substrate are presented. The single-photon nature of the radiation is confirmed by measuring and analyzing second-order correlation functions g{sup (2)}(τ); g{sup (2)}(0) = 0.07. The fine structure of the exciton states of (111) In(Ga)As quantum dots is investigated. It is shown that, in the energy range of 1.320–1.345 eV, the splitting of exciton states is comparable to the natural width of the exciton lines, which is of interest for developing photon-pair emitters based on them.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The soft x-ray instrument for materials studies at the linac coherent light source x-ray free-electron laser

The soft x-ray materials science instrument is the second operational beamline at the linac coherent light source x-ray free electron laser. The instrument operates with a photon energy range of 480-2000 eV and features a grating monochromator as well as bendable refocusing mirrors. A broad range of experimental stations may be installed to study diverse scientific topics such as: ultrafast chemistry, surface science, highly correlated electron systems, matter under extreme conditions, and laboratory astrophysics. Preliminary commissioning results are presented including the first soft x-ray single-shot energy spectrum from a free electron laser.

43 PARTICLE ACCELERATORS↗

THE Low-level Radio Frequency System for the superconducting cavities of National Synchrotron Light Source II

A digital low-level radio frequency (LLRF) field controller has been developed for the storage ring of The National Synchrotron Light Source-II (NSLS-II). The primary performance goal for the LLRF is to support the required RF operation of the superconducting cavities with a beam current of 500mA and a 0.14 degree or better RF phase stability. The digital field controller is FPGA-based, in a standard format 19-inch/I-U chassis. It has an option of high-level control support with MATLAB running on a local host computer through a USB2.0 port. The field controller has been field tested with the high-power superconducting RF (SRF) at Canadian light Source, and successfully stored a high beam current of 250 mA. The test results show that required specifications for the cavity RF field stability are met. This digital field controller is also currently being used as a development platform for other functional modules in the NSLS-II RF systems.

43 PARTICLE ACCELERATORS↗

Using X-ray Light to Study Solar Materials at the Advanced Light Source

Shambhavi Pratap, ALS Doctoral Fellow in Residence and a Doctoral Researcher at the Technical University of Munich, will discuss how she studies thin-film solar energy materials using X-rays at the ALS. The Advanced Light Source is a DOE Office of Science User Facility. The International Day of Light is recognized by the United Nations Educational, Scientific and Cultural Organization (UNESCO).

14 SOLAR ENERGY↗

Status of PEP-X Light Source Design Study

The SLAC Beam Physics group and other SLAC collaborators continue to study options for implementing a near diffraction-limited ring-based light source in the 2.2-km PEP-II tunnel that will serve the SSRL scientific program in the future. The study team has completed the baseline design for a 4.5-GeV storage ring having 160 pm-rad emittance with stored beam current of 1.5 A, providing >10{sup 22} brightness for multi-keV photon beams from 3.5-m undulator sources. The team has also investigated possible 5-GeV ERL configurations which, similar to the Cornell and KEK ERL plans, would have {approx}30 pm-rad emittance with 100 mA current, and {approx}10 pm-rad emittance with 25 mA or less. Now a 4.5-GeV 'ultimate' storage ring having emittance similar to the ERL and operating with {approx}200 mA is under study. An overview of the progress of the PEP-X design study and SSRL's plans for defining performance parameters that will guide the choice of ring options is presented.

43 PARTICLE ACCELERATORS↗

Demonstration of a diamond anvil cell platform at the Linac Coherent Light Source: capabilities and outlook

A novel X-ray free electron laser (XFEL) diffraction setup for use with diamond anvil cells (DACs) at the Linac Coherent Light Source (LCLS) is described. The new diamond window at the Matter at Extreme Conditions (MEC) instrument allows hard X-ray experiments on DACs to be performed in air. The platform is described along with alignment and calibration procedures, and details of the X-ray beam and diagnostics. Example data are presented, including a reversible XFEL-induced phase transition in CsPbI 3 . The DAC setup was commissioned at MEC, but is applicable to most LCLS instruments where the unique pulse structures available at LCLS offer access to new ultrafast experimental techniques at high pressure.

Linac Coherent Light Source (LCLS)↗

Billion particle linac simulations for future light sources

In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.

43 PARTICLE ACCELERATORS↗

Sextupole reduction via chaos suppression at the National Synchrotron Light Source II

We revisit the nonlinear lattice design approach for the National Synchrotron Light Source II (NSLS-II) storage ring. By suppressing chaos, we identify alternative sextupole configurations to the original design, which relied on the conventional strategy of simultaneously minimizing resonance driving terms (RDTs) and amplitude-dependent detuning (ADD). These alternatives achieve comparable performance while requiring fewer sextupoles. A detailed comparison of two representative solutions is presented and supported by experimental validation. Our results show that the dynamic aperture correlates more strongly with global chaos than with individual RDTs, and that the importance of minimizing ADD may have been overstated in earlier design strategies.

36 MATERIALS SCIENCE↗

The Atomic, Molecular and Optical Science instrument at the Linac Coherent Light Source

The Atomic, Molecular and Optical Science (AMO) instrument at the Linac Coherent Light Source (LCLS) provides a tight soft X-ray focus into one of three experimental endstations. The flexible instrument design is optimized for studying a wide variety of phenomena requiring peak intensity. There is a suite of spectrometers and two photon area detectors available. An optional mirror-based split-and-delay unit can be used for X-ray pump–probe experiments. Recent scientific highlights illustrate the imaging, time-resolved spectroscopy and high-power density capabilities of the AMO instrument.

43 PARTICLE ACCELERATORS↗

Combining THz laser excitation with resonant soft X-ray scattering at the Linac Coherent Light Source

This paper describes the development of new instrumentation at the Linac Coherent Light Source for conducting THz excitation experiments in an ultra high vacuum environment probed by soft X-ray diffraction. This consists of a cantilevered, fully motorized mirror system which can provide 600 kV cm⁻¹ electric field strengths across the sample and an X-ray detector that can span the full Ewald sphere with in-vacuum motion. The scientific applications motivated by this development, the details of the instrument, and spectra demonstrating the field strengths achieved using this newly developed system are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Building the World's Most Advanced Light Source

View this time-lapse video showing construction of the National Synchrotron Light Source II at Brookhaven National Laboratory. Construction is shown from 2009-2012.

43 PARTICLE ACCELERATORS↗

Radiation Protection Aspects of the Linac Coherent Light Source Front End Enclosure

The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experimental stations and reduce the bremsstrahlung background and the hard component of the spontaneous radiation spectrum. This paper addresses the beam loss assumptions and radiation sources entering the FEE used for the design of the FEE shielding using the Monte-Carlo code FLUKA. The beam containment system prevents abnormal levels of radiations inside the FEE and ensures that the beam remains in its intended path is also described.

Vollaire, J.↗

X-RAY ACTIVE MATRIX PIXEL SENSORS BASEDON J-FET TECHNOLOGY DEVELOPED FOR THE LINAC COHERENT LIGHT SOURCE.

An X-ray Active Matrix Pixel Sensor (XAMPS) is being developed for recording data for the X-ray Pump Probe experiment at the Linac Coherent Light Source (LCLS). Special attention has to be paid to some technological challenges that this design presents. New processes were developed and refined to address problems encountered during previous productions of XAMPS. The development of these critical steps and corresponding tests results are reported here.

43 PARTICLE ACCELERATORS↗

Sub-nanosecond time-resolved ambient-pressure X-ray photoelectron spectroscopy setup for pulsed and constant wave X-ray light sources

An apparatus for sub-nanosecond time-resolved ambient-pressure X-ray photoelectron spectroscopy studies with pulsed and constant wave X-ray light sources is presented. A differentially pumped hemispherical electron analyzer is equipped with a delay-line detector that simultaneously records the position and arrival time of every single electron at the exit aperture of the hemisphere with ∼0.1 mm spatial resolution and ∼150 ps temporal accuracy. The kinetic energies of the photoelectrons are encoded in the hit positions along the dispersive axis of the two-dimensional detector. Pump-probe time-delays are provided by the electron arrival times relative to the pump pulse timing. An average time-resolution of (780 ± 20) ps (FWHM) is demonstrated for a hemisphere pass energy E{sub p} = 150 eV and an electron kinetic energy range KE = 503–508 eV. The time-resolution of the setup is limited by the electron time-of-flight (TOF) spread related to the electron trajectory distribution within the analyzer hemisphere and within the electrostatic lens system that images the interaction volume onto the hemisphere entrance slit. The TOF spread for electrons with KE = 430 eV varies between ∼9 ns at a pass energy of 50 eV and ∼1 ns at pass energies between 200 eV and 400 eV. The correlation between the retarding ratio and the TOF spread is evaluated by means of both analytical descriptions of the electron trajectories within the analyzer hemisphere and computer simulations of the entire trajectories including the electrostatic lens system. In agreement with previous studies, we find that the by far dominant contribution to the TOF spread is acquired within the hemisphere. However, both experiment and computer simulations show that the lens system indirectly affects the time resolution of the setup to a significant extent by inducing a strong dependence of the angular spread of electron trajectories entering the hemisphere on the retarding ratio. The scaling of the angular spread with the retarding ratio can be well approximated by applying Liouville's theorem of constant emittance to the electron trajectories inside the lens system. The performance of the setup is demonstrated by characterizing the laser fluence-dependent transient surface photovoltage response of a laser-excited Si(100) sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of vacuum ultraviolet absorption spectroscopy system for wide measurement range of number density using a dual-tube inductively coupled plasma light source

A vacuum ultraviolet absorption spectroscopy system for a wide measurement range of atomic number densities is developed. Dual-tube inductively coupled plasma was used as a light source. The probe beam profile was optimized for the target number density range by changing the mass flow rate of the inner and outer tubes. This system was verified using cold xenon gas. As a result, the measurement number density range was extended from the conventional two orders to five orders of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THz pulses from 4th generation X-ray light sources: Perspectives for fully synchronized THz pump X-ray probe experiments

In this paper the prospects of terahertz (THz) pulses generated at 4th generation X-ray light sources are presented on the example of recent results from a prototype set-up at the soft X-ray FEL FLASH. It is shown, that the THz pulses from the relativistic ultra short electron bunches have unique properties, that at FLASH are utilized for novel THz pump X-ray probe experiments with a robust few fs resolution. Based on these experiences it is discussed, how future facilities can benefit from implementation of similar or further improved instrumentation.

43 PARTICLE ACCELERATORS↗