Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light sensitive materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Understanding spectral dependance of laser-induced damage precursors in dielectric materials (Abbreviated report_23-ERD-006)

High peak and average power laser systems are typically limited by the handling fluence of the optical components. In particular, the multilayer dielectric coatings are known to be much lower operational fluence than the more ideal bulk materials. In this project we proposed and succeeded in probing different established classes of damage prone precursors at different wavelengths to understand their fundamental laser damage response as a function of wavelength. This study helped to shed light on the fundamental physics of the non-linear precursors that govern laser damage phenomena for ns-regime pulsed laser damage. In this study, we utilized the onsite coating capabilities (VPL, IBS coating lab) to purposefully generate laser damage-prone precursors in hafnia-based coatings (both single and multi-layer coatings). Specifically, we engineered coatings with craze lines initiated by nodules, generated coatings with our xenon-based coating process to suppress nanobubble formation and generated hafnia coatings under controlled oxygen flow conditions to study hafnia sub-oxides and oxygen flow dependance. In these studies we found that craze lines are rife with precursors that are sensitive to ultra-violet light but not to infrared light; we found that the removal of nanobubbles helps with all wavelengths tested, but is most impactful for ultra-violet light; we also found that ultra-violet laser damage performance of hafnia is closely matched to oxygen flow rate, while the infrared performance may be slightly better at lower flow rates. During this LDRD we also successfully stood up a new laser damage testing capability, namely a wavelength agile damage test station to study the spectral response of known laser-induced damage precursors. This is a unique and important capability for Lawrence Livermore National Lab, allowing us to understand the spectral response of materials under high intensity irradiation and damage. This is a vital tool to understand non-linear optical response at wavelengths that we have previously been unable to test at.

36 MATERIALS SCIENCE↗

Mechanically flexible mid-wave infrared imagers using black phosphorus ink films

The mid-wave infrared (MWIR) spectral range (λ = 3–8 μm) enables important sensing and imaging applications, including non-invasive bioimaging, night vision, and autonomous navigation. Commercial MWIR photodetectors are limited to rigid imagers based on heteroepitaxial materials. There is an emerging need for mechanically flexible MWIR imagers to broaden their functionality and practicality. Recently, photodetectors using van der Waals (vdW) black phosphorus (BP) flakes have demonstrated highly sensitive room-temperature photodetection. Additionally, vdW materials are solution-processable, facilitating scalable processing and flexible device fabrication. In this work, we present flexible MWIR imagers consisting of photodiodes fabricated on thin plastic substrates using BP ink films. We demonstrate mechanically robust responsivity up to 2.5-mm bending radii and after 5000 bending cycles. Leveraging this flexibility, we achieve full-azimuthal imaging, detecting directional light sources with precision. These results establish a scalable approach for large-area, conformable MWIR imaging and pave the way for integration with flexible electronics.

Wijaya, Theodorus Jonathan↗

Confocal Raman Microscopy as an In Situ Probe of Volume Change in Hydration-Sensitive Polymer Membranes

An approach is described for measuring hydration-induced volume change within ion conductive polymer membranes and thin films by adapting the technique of confocal Raman microscopy. With careful consideration of factors that affect excitation and scattering within the confocal probe volume region, material swelling and deswelling were estimated from the intensities of polymer matrix spectral features. A high numerical aperture oil-immersion objective was used to achieve tight focusing within samples and the efficient collection of Raman scattered light. The approach is demonstrated for a fluorinated cation-exchange ionomer (Nafion) and the hydrocarbon anion-exchange ionomer Sustainion. Samples were monitored while under a nitrogen atmosphere that was cycled between dry and humid (∼50% relative humidity, RH) states. The volume changes estimated from the Raman spectra were in close agreement with those derived from conventional measurements. The reported work advances understanding needed to adapt confocal Raman microscopy for quantitative in situ and operando studies of ionomers within electrochemical devices, such as polymer electrolyte membrane fuel cells and electrolyzers, and lays a foundation for broader applications in the study of hydration-induced polymer swelling and the associated molecular level water and polymer framework structural changes.

Absorption↗

Schlieren optics for leak detection

The purpose of this research was to develop an optical method of leak detection. Various modifications of schlieren optics were explored with initial emphasis on leak detection of the plumbing within the orbital maneuvering system of the space shuttle (OMS pod). The schlieren scheme envisioned for OMS pod leak detection was that of a high contrast pattern on flexible reflecting material imaged onto a negative of the same pattern. We find that the OMS pod geometry constrains the characteristic length scale of the pattern to the order of 0.001 inch. Our experiments suggest that optical modulation transfer efficiency will be very low for such patterns, which will limit the sensitivity of the technique. Optical elements which allow a negative of the scene to be reversibly recorded using light from the scene itself were explored for their potential in adaptive single-ended schlieren systems. Elements studied include photochromic glass, bacteriorhodopsin, and a transmissive liquid crystal display. The dynamics of writing and reading patterns were studied using intensity profiles from recorded images. Schlieren detection of index gradients in air was demonstrated.

Peale, Robert E.↗

Nonlinear X-ray Optics

Novel X-ray free-electron lasers (XFELs) are capable of producing radiation with unprecedented properties. Specifically, their ultrashort coherent X-ray pulses can generate extreme peak intensities where ordinary rules of light-matter interaction may no longer apply, and nonlinear processes start to become important. XFELs have made it possible to observe some of the most important coherent non-sequential nonlinearities, including X-ray-optical sum frequency generation (SFG), X-ray second harmonic generation (XSHG), two-photon absorption (TPA) and nonlinear two-photon Compton scattering (2PCS). In particular, the 2PCS experiment has led to unexpected results, namely the observation of a substantial anomalous red shift in the energy of photons generated by nonlinear two-photon X-ray Compton scattering in beryllium. The energy shift is in addition to the predicted nonlinear Compton shift and was neither expected from extrapolations from linear X-ray interactions nor from nonlinear effects at optical wavelengths. Our results suggest a novel nonlinear scattering mechanism that can only be observed at high fields at X-ray wavelengths, where the photon energy is a significant fraction of the electron rest mass (and thus a significant momentum transfer to the electron occurs during the scattering) and where the interaction is not dominated by the quiver motion of the electron in the field (ponderomotive potential) as is usually the case at longer (optical) wavelengths. The goal of this research project was the investigation of fundamental nonlinear X-ray-matter interactions. As these processes are typically weak, part of this research is the exploration of more efficient nonlinear X-ray processes by studying novel mechanisms including solid-state effects, the assistance of optical radiation and novel phase-matching techniques. These experiments require extremely large X-ray field strengths, such as produced by XFELs. Nonlinear X-ray effects can lead to important applications in many research fields. For example, it could lead to instantaneous plasma diagnostics for materials in extreme conditions, as a method for combining atomic-scale structural sensitivity with chemical specificity, or as a probe of electron dynamics in solids on the attosecond (1 as = 10 -18 s) time- and Ångstrom (10 -10 m) length scales. In addition, a detailed understanding of nonlinear X-ray matter interactions is crucial for understanding and extending the limits of structural determination at high intensity such as in serial femto-crystallography. The results could have a profound impact on advanced XFEL light sources such as the LCLS-II.

47 OTHER INSTRUMENTATION↗

Integral Experiment Request 554 CED-1 Summary Report

This Critical Engineering Decision 1 report for the Integral Experiment Request 554 describes the effects of adding a commercially available neutron absorber material to a known light-water low-enriched uranium assembly. The assembly in question is the Seven Percent Critical Experiments at Sandia National Laboratories. The neutron absorber plates considered for the experiment are called Boralcan, which are made of boron carbide (B 4 C) particles embedded in 1100 aluminum alloy. The concentrations of B 4 C and 1100 aluminum, as well as the thickness and size of the plates, were changed, and the fuel rod configuration was adapted to ensure that the assembly would be critical in each case studied. A total of 10 critical configurations with a neutron absorber plate inserted are described in this report. No results of high-quality integral experiments involving neutron absorbers made with B 4 C and 1100 aluminum plates are currently publicly available. Sensitivity to the neutron absorber plate material definition, isotopes, and cross sections of specific regions and configurations are also analyzed. The study results indicate that these experiments are achievable with sufficiently low uncertainties and minimal modification to the assembly. The experimental uncertainty can be further decreased with an additional characterization of the plates by x-ray computerized tomography or neutron radiography methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HPE ultralit project (ARPA-E open program 2018) final report 15

The goal of the program was to build a fully integrated optical transceiver with >1 Tb/s and <1.5 pJ/bit operating at 50 ◦ C. Optical transceivers are critical components in high-performance-computers (HPC) and data centers, and the details of their implementation has a big impact on the total power consumption (energy efficiency) of an HPC system. Our proposed transceiver used three key enabling technologies. Firstly, SiGe avalanche photodetectors have record-low sensitivities, meaning that they can reach low bit error rates with very little light input. As a result, we can drive our lasers at a lower drive current, thus saving electrical power. Secondly, we use MOS-based capacitive tuning in our deinterleaver, modulator, and demultiplexer. Capacitive tuning allows for the tuning of photonic elements with zero static power consumption. Thirdly, we use quantum dots as the gain material in our light source. This allows us to efficiently use our light source at temperatures that are typically encountered in an HPCsystem. Our proposed optical transceiver consisted of a quantum dot comb laser as a light source, a booster SOA, MOS-based deinterleavers, MOS based ring modulators, MOS-based ring demultiplexers, and SiGe APDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Holographic Gratings for Optical Processing

Investigation of astronomical objects and tracking of man-made space objects lead to generation of huge amount of information for optical processing. Traditional big-size optical elements (such as optical telescopes) have a tendency for increasing aperture size in order to improve sensitivity. This tendency leads to increasing of weight and costs of optical systems and stimulate search for the new, more adequate technologies. One approach to meet these demands is based on developing of holographic optical elements using new polymeric materials. We have investigated possibility to use new material PQ-PMMA (phenantrenequinone-doped PMMA (Polymethyl Methacrylate)) for fabrication of highly selective optical filters and fast spatial-temporal light modulators. This material was originally developed in Russia and later was tested in CalTech as a candidate material for optical storage. Our theoretical investigation predicts the possibility of realization of fast spatial and temporal light modulation, using volume reflection-type spectral filter. We have developed also model of holographic-grating recording in PQ-PMMA material, based on diffusional amplification. This mechanism of recording allow to receive high diffraction efficiency during recording of reflection-type volume holographic grating (holographic mirror). We also investigated recording of dynamic gratings in the photorefractive crystals LiNbO3 (LN) for space-based spectroscopy and for adaptive correction of aberrations in the telescope's mirrors. We have shown, that specific 'photogalvanic' mechanism of holographic grating recording in LN allow to realize recording of blazed gratings for volume and surface gratings. Possible applications of dynamic gratings in LN for amplification of images, transmitted through an imaging fiber guide was also demonstrated.

Nickolai Kukhtarev↗

Laboratory Instruments Available to Support Space Station Researchers at Marshall Space Flight Center

A number of research instruments are available at NASA's Marshall Space Flight Center (MSFC) to support ISS researchers and their investigations. These modern analytical tools yield valuable and sometimes new informative resulting from sample characterization. Instruments include modern scanning electron microscopes equipped with field emission guns providing analytical capabilities that include angstron-level image resolution of dry, wet and biological samples. These microscopes are also equipped with silicon drift X-ray detectors (SDD) for fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations in crystalline alloys. Sample chambers admit large samples, provide variable pressures for wet samples, and quantitative analysis software to determine phase relations. Advances in solid-state electronics have also facilitated improvements for surface chemical analysis that are successfully employed to analyze metallic materials and alloys, ceramics, slags, and organic polymers. Another analytical capability at MSFC is a mganetic sector Secondary Ion Mass Spectroscopy (SIMS) that quantitatively determines and maps light elements such as hydrogen, lithium, and boron along with their isotopes, identifies and quantifies very low level impurities even at parts per billion (ppb) levels. Still other methods available at MSFC include X-ray photo-electron spectroscopy (XPS) that can determine oxidation states of elements as well as identify polymers and measure film thicknesses on coated materials, Scanning Auger electron spectroscopy (SAM) which combines surface sensitivity, spatial lateral resolution (approximately 20 nm), and depth profiling capabilities to describe elemental compositions in near surface regions and even the chemical state of analyzed atoms. Conventional Transmission Electron Microscope (TEM) for observing internal microstructures at very high magnifications and the Electron Probe Micro-analyzer (EPMA) for very precise microanalysis are available as needed by the researcher. Space Station researchers are invited to work with MSFC in analyzing their samples using these techniques.

Panda, Binayak↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

Preliminary Design of Critical Experiments Involving Commercially Available B 4 C Neutron Absorber Plates with Low-Enriched UO 2 Fuel

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) is an initiative to provide high-quality benchmark data in a standardized format for criticality safety analysts to use to validate calculational tools and nuclear data. In the last released 2022 version, the ICSBEP handbook contains over 5,000 critical experiment descriptions, results, and associated models. This paper describes the critical configurations proposed and calculations performed as part of the conceptual design phase of Integral Experiment Request (IER) 554 (IER-554). The goal of IER-554 is to add to the benchmark experiments available to the criticality safety community by designing critical experiments that can analyze how adding commercially available Boralcan plates to an assembly of low-enriched UO2 fuel rods affects the effective neutron multiplication factor (k eff ). Boralcan, a neutron absorber product developed by Rio Tinto, is made of B4C in an Al 1100 matrix and is commonly used for criticality suppression in fuel storage pools. In the current version of the ICSBEP handbook, only a few dated critical experiments involve B4C materials, and none involve Boralcan in a thin plate shape. The experiments designed as part of IER-554 are intended to be performed at the Sandia Pulsed Reactor Facility/Critical Experiments (SPRF/CX) apparatus at Sandia National Laboratories. SPRF/CX is a well-characterized assembly considered trustworthy by the benchmarking community because of the numerous high-quality evaluations with very low experimental uncertainties included in the ICSBEP handbook. Figure 1 illustrates the assembly for a particular configuration from LCT-078, one of the published benchmarks in the ICSBEP handbook. The experiments will be moderated and reflected by light water at ambient atmospheric pressure. Before the plates are inserted in the critical assembly, they will be characterized with x-ray computed tomography (XCT) to identify the sizes and distribution of the B 4 C powder particles inside the plates. The preliminary design calculations were performed with SCALE 6.3.0 using the KENO V.a sequence for the criticality calculations, the CE-TSUNAMI-3D sequence for the sensitivity and uncertainty studies, and the ENDF/B-VII.1 Continuous Energy cross section library. All the calculation results presented have 10 pcm statistical uncertainties. A set of critical experiments with Boralcan plates could increase the confidence of the criticality safety community in its modeling methods when using this type of neutron absorber material. Experiments would also help validate k eff calculations, and the industry could use these validations to change the B loading credit limits from the US Nuclear Regulatory Commission standard review plan for dry cask storage of spent nuclear fuel. This paper summarizes only part of the analysis documented in the preliminary design report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Experiment Request 554: CED-2 Summary Report

This report summarizes the critical experiment design 2 (CED-2) or final design study for Integral Experiment Request 554 (IER-554). This experiment describes the effects and importance of adding a commercially available neutron absorber material to a known light-water low-enriched uranium assembly. The assembly in question is the Seven Percent Critical Experiments (7uPCX) at Sandia National Laboratories. The neutron absorber plates considered for the experiment are known as Boralcan and are made of boron carbide (B 4 C) particles embedded in 1100 aluminum alloy. The concentrations of B 4 C and 1100 aluminum were changed as well as the thickness and the positions of the plates, and the fuel rod configuration was adapted to ensure that the assembly would be critical in each case studied. A total of 6 critical configurations, each with a neutron absorber plate inserted, are described in this report. No results of high-quality integral experiments involving neutron absorbers made with B 4 C and 1100 aluminum plates are currently publicly available. Sensitivity to the neutron absorber plate material definition, isotopes, and cross sections of specific regions and configurations are also analyzed. As part of the final design of the experiment, a safe plate holder made of 3003 aluminum was designed. The study results indicate that these experiments are achievable with sufficiently low uncertainties and minimal modification to the assembly, and the CED-3 phase can start when funding allows.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The UV Photoinduced Ring-Closing Reaction of Cyclopentadiene Probed with Ultrafast Electron Diffraction

Conjugated cyclic organic molecules are common across many fields such as pharmaceuticals, are naturally occurring in biological systems, and are used in synthetic materials. One particular area of interest from a photochemical point of view is the formation of highly strained cyclic organics. We investigate the photoinduced reaction of cyclopentadiene, a five-membered organic ring molecule which can form strained three and four carbon rings after photoexcitation with UV light, with the gas-phase ultrafast electron diffraction instrument at the SLAC MeV-UED facility. Electron diffraction offers a direct probe sensitive to the nuclear geometry during the reaction, allowing for the determination of the distribution of products formed following photoexcitation. We observe the simultaneous formation of the highly strained ring- closed bicyclo[2.1.0]pentene and vibrationally hot cyclopentadiene within the temporal resolution of the experiment, and determine the relative yield of all reaction products. Furthermore, the experimental results are in good agreement with the predictions of trajectory simulations.

Computational Chemistry↗

High-Reflectivity Multi-Layer Coatings for the CLASP Sounding Rocket Project

We are planning an international rocket experiment Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is (2015 planned) that Lyman alpha line (Ly alpha line) polarization spectroscopic observations from the sun. The purpose of this experiment, detected with high accuracy of the linear polarization of the Ly alpha lines to 0.1% by using a Hanle effect is to measure the magnetic field of the chromosphere-transition layer directly. For polarization photometric accuracy achieved that approximately 0.1% required for CLASP, it is necessary to realize the monitoring device with a high throughput. On the other hand, Ly alpha line (vacuum ultraviolet rays) have a sensitive characteristics that is absorbed by the material. We therefore set the optical system of the reflection system (transmission only the wavelength plate), each of the mirrors, subjected to high efficiency of the multilayer coating in accordance with the role. Primary mirror diameter of CLASP is about 30 cm, the amount of heat about 30,000 J is about 5 minutes of observation time is coming mainly in the visible light to the telescope. In addition, total flux of the sun visible light overwhelmingly large and about 200 000 times the Ly alpha line wavelength region. Therefore, in terms of thermal management and 0.1% of the photometric measurement accuracy achieved telescope, elimination of the visible light is essential. We therefore, has a high reflectivity (greater than 50%) in Ly alpha line, visible light is a multilayer coating be kept to a low reflectance (less than 5%) (cold mirror coating) was applied to the primary mirror. On the other hand, the efficiency of the polarization analyzer required chromospheric magnetic field measurement (the amount of light) Conventional (magnesium fluoride has long been known as a material for vacuum ultraviolet (MgF2) manufactured ellipsometer; Rs = 22%) about increased to 2.5 times were high efficiency reflective polarizing element analysis. This device, Bridou et al. (2011) is proposed "that is coated with a thin film of the substrate MgF2 and SiO2 fused silica." As a result of the measurement, Rs = 54.5%, to achieve a Rp = 0.3%, high efficiency, of course, capable of taking out only about spolarized light. Other reflective optical elements (the secondary mirror, the diffraction grating-collector mirror), subjected to high-reflection coating of Al + MgF2 (reflectance of about 80%), less than 5% in the entire optical system by these (CCD Science was achieved a high throughput as a device for a vacuum ultraviolet ray of the entire system less than 5% (CCD of QE is not included).

sounding rocket↗

Solar Lyman-Alpha Polarization Observation of the Chromosphere and Transition Region by the Sounding Rocket Experiment CLASP

We are planning an international rocket experiment Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is (2015 planned) that Lyman α line (Ly(alpha) line) polarization spectroscopic observations from the sun. The purpose of this experiment, detected with high accuracy of the linear polarization of the Ly(alpha) lines to 0.1% by using a Hanle effect is to measure the magnetic field of the chromosphere-transition layer directly. For polarization photometric accuracy achieved that approx. 0.1% required for CLASP, it is necessary to realize the monitoring device with a high throughput. On the other hand, Ly(alpha) line (vacuum ultraviolet rays) have a sensitive characteristics that is absorbed by the material. We therefore set the optical system of the reflection system (transmission only the wavelength plate), each of the mirrors, subjected to high efficiency of the multilayer coating in accordance with the role. Primary mirror diameter of CLASP is about 30 cm, the amount of heat about 30,000 J is about 5 minutes of observation time is coming mainly in the visible light to the telescope. In addition, total flux of the sun visible light overwhelmingly large and about 200 000 times the Ly(alpha) line wavelength region. Therefore, in terms of thermal management and 0.1% of the photometric measurement accuracy achieved telescope, elimination of the visible light is essential. We therefore, has a high reflectivity (> 50%) in Lyα line, visible light is a multilayer coating be kept to a low reflectance (<5%) (cold mirror coating) was applied to the primary mirror. On the other hand, the efficiency of the polarization analyzer required chromospheric magnetic field measurement (the amount of light) Conventional (magnesium fluoride has long been known as a material for vacuum ultraviolet (MgF2) manufactured ellipsometer; Rs = 22%) about increased to 2.5 times were high efficiency reflective polarizing element analysis. This device, Bridou et al. (2011) is proposed "that is coated with a thin film of the substrate MgF2 and SiO2 fused silica." As a result of the measurement, Rs = 54.5%, to achieve a Rp = 0.3%, high efficiency, of course, capable of taking out only about s-polarized light. Other reflective optical elements (the secondary mirror, the diffraction gratingcollector mirror), subjected to high-reflection coating of Al + MgF2 (reflectance of about 80%), less than 5% in the entire optical system by these (CCD Science was achieved a high throughput as a device for a vacuum ultraviolet ray of the entire system less than 5% (CCD of QE is not included).

Narukage, Noriyuki↗

New Pulsed Neutron Die-Away Experiments in Light Water

Thermal neutron scattering laws are important data for many nuclear science and engineering applications, especially criticality safety. Recently, pulsed-neutron die-away experiments have been proposed and used as an experiment to validate thermal neutron scattering laws. These experiments involve irradiating a target moderating material with pulses of neutrons from a neutron generator. The physics of thermal scattering greatly affect how the neutron population in the target exponentially decays via absorption and leakage. Herein, we present experimental results from a new pulsed-neutron die-away experiment of light water that was performed at Lawrence Livermore National Laboratory. The experiments were done with cylindrical targets of varying dimensions to modulate the experiment’s sensitivity to thermal scattering and to absorption. We compare the measured integral parameter of the experiment to simulations with MCNP6.2 ® and to past experiments in literature. The integral parameters that were more sensitive to TSLs showed a larger bias. This validation study is known to have errors because the model of the experiment lacks key features about the detectors and neutron generator. These features will be included in the final benchmark evaluation of the experiment which will be submitted to the International Criticality Safety Benchmark Evaluation Project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polymeric Materials With Additives for Durability and Radiation Shielding in Space

Polymeric materials are attractive for use in space structures because of their light weight and high strength In addition, polymers are made of elements with low atomic numbers (Z), primarily carbon (C), hydrogen (H), oxygen (0), and nitrogen (N) which provide the best shielding from galactic cosmic rays (GCR) (ref. 1). Galactic cosmic rays are composed primarily of nuclei (i.e., fully ionized atoms) plus a contribution of about 2% from electrons and positrons. There is a small but significant component of GCR particles with high charge (Z > 10) and high energy (E >100 GeV) (ref. 2). These so-called HZE particles comprise only 1 to 2% of the cosmic ray fluence but they interact with very high specific ionization and contribute 50% of the long- term dose to humans. The best shield for this radiation would be liquid hydrogen, which is not feasible. For this reason, hydrogen-containing polymers make the most effective practical shields. Moreover, neutrons are formed in the interactions of GCR particles with materials. Neutrons can only lose energy by collisions or reactions with a nucleus since they are uncharged. This is a process that is much less probable than the Coulombic interactions of charged particles. Thus, neutrons migrate far from the site of the reaction in which they were formed. This increases the probability of neutrons reaching humans or electronic equipment. Fast neutrons (> 1 MeV) can interact with silicon chips in electronic equipment resulting in the production of recoil ions which can cause single event upsets (SEU) in sensitive components (ref. 3). Neutrons lose energy most effectively by elastic collisions with light atoms, particularly hydrogen atoms. Therefore, hydrogen-containing polymers are not only effective in interacting with GCR particles; they are also effective in reducing the energy of the neutrons formed in the interactions.

Kiefer, Richard↗

Characterization of a boron-loaded deuterated liquid scintillator for fast and thermal neutron detection

The preparation and characterization of novel boron-loaded deuterated liquid scintillators (BLDLS) are presented for the first time to investigate the performance of a detector sensitive to both fast and thermal neutrons intended for future neutron spectroscopy measurements. Three deuterated toluene-based scintillation cocktails were produced, one without boron, one loaded with ortho-carborane (natural boron isotopic abundance), and one with 96 wt% 10B enriched ortho-carborane. General optical and material properties were analyzed to include the composition, density, index of refraction, photoluminescence emission spectra, and absorbance spectra in addition to the relative light yield, resolution, relative efficiency, and pulse-shape-discrimination performance for all three scintillators and a hydrogen-based EJ-309 scintillator to evaluate the effects of boron loading in comparison with a common commercially-available scintillator and feasibility for future neutron spectroscopy measurements. Finally, the detection of shielded neutron sources was explored to capitalize on the 10B thermal neutron capture reaction. The results showed loading the scintillators with boron deteriorated the PSD performance slightly compared to the unloaded deuterated scintillator and resulted in a relative light yield loss of 26% and 41% for the 10B enriched and natural boron BLDLS, respectively. Lastly, the BLDLS have a higher relative detection efficiency than the unloaded deuterated scintillator for shielded neutron sources, based on total count rate, a desirable characteristic for missions related to finding and characterizing illicitly-trafficked special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗