Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

NASA ground-based and space-based laser ranging systems

The development of NASA laser ranging systems is discussed with reference to applications such as orbit determination, gravity-field studies, and analyses of polar motion, earth tides, and tectonic plate motion. Several laser ranging designs are described noting the first satellite laser ranging experiment, the Moblas II and III systems, and the laser ranging satellites presently in orbit. Primary error sources are identified as atmospheric delay, optical signal-to-noise ratios, the electron multiplier, time-interval measurements, and target noise. Plans for Shuttle-based laser ranging systems are reviewed noting simulation studies of 12-day Shuttle missions.

Fitzmaurice, M. W.↗

Development of a US Gravitational Wave Laser System for LISA

A highly stable and robust laser system is a key component of the space-based LISA mission architecture.In this talk I will describe our plans to demonstrate a TRL 5 LISA laser system at Goddard Space Flight Center by 2016.The laser system includes a low-noise oscillator followed by a power amplifier. The oscillator is a low-mass, compact 10mW External Cavity Laser, consisting of a semiconductor laser coupled to an optical cavity, built by the laser vendorRedfern Integrated Optics. The amplifier is a diode-pumped Yb fiber with 2W output, built at Goddard. I will show noiseand reliability data for the full laser system, and describe our plans to reach TRL 5 by 2016.

Development of a US Gravitational Wave↗

Reflection Effects in Multimode Fiber Systems Utilizing Laser Transmitters

A number of optical communication lines are now in use at NASA-Kennedy for the transmission of voice, computer data, and video signals. Now, all of these channels use a single carrier wavelength centered near 1300 or 1550 nm. Engineering tests in the past have given indications of the growth of systematic and random noise in the RF spectrum of a fiber network as the number of connector pairs is increased. This noise seems to occur when a laser transmitter is used instead of a LED. It has been suggested that the noise is caused by back reflections created at connector fiber interfaces. Experiments were performed to explore the effect of reflection on the transmitting laser under conditions of reflective feedback. This effort included computer integration of some of the instrumentation in the fiber optic lab using the Lab View software recently acquired by the lab group. The main goal was to interface the Anritsu Optical and RF spectrum analyzers to the MacIntosh II computer so that laser spectra and network RF spectra could be simultaneously and rapidly acquired in a form convenient for analysis. Both single and multimode fiber is installed at Kennedy. Since most are multimode, this effort concentrated on multimode systems.

Bates, Harry E.↗

Massively distributed fiber strain sensing using Brillouin lasing

Brillouin based distributed fiber sensors present a unique set of characteristics amongst fiber sensing architectures. They are able to measure absolute strain and temperature over long distances, with high spatial resolution, and very large dynamic range in off-the-shelf fiber. However, Brillouin sensors traditionally provide only modest sensitivity due to the weak dependence of the Brillouin frequency on strain and the high signal to noise ratio required to identify the resonance’s peak frequency to within a small fraction of its linewidth. Recently, we introduced a technique which substantially improves the precision of Brillouin fiber sensors by exciting a series of lasing modes in a fiber loop cavity that experience Brillouin amplification at discrete locations in the fiber. The narrow-linewidth and high intensity of the lasing modes enabled ultra-low noise Brillouin sensors with large dynamic range. However, our initial demonstration was only modestly distributed: measuring strain at 40, non-contiguous positions along a 400 m fiber. In this work, we greatly extend this methodology to enable fully distributed sensing at 1000 contiguous locations along 3.5 km of fiber—an order of magnitude increase in sensor count and range. This highly-multiplexed Brillouin fiber laser sensor provides a strain noise as low as 34 nɛ/√Hz and we analyze the limiting factors in this approach.

47 OTHER INSTRUMENTATION↗

Laser induced asymmetry and inhomogeneous broadening of the microwave lineshape of a gas cell atomic frequency standard

The possibility of replacing the RF discharge lamp in a rubidium gas cell clock with a single mode laser diode is addressed. Since the short term stability of the rubidium frequency standard is limited by the shot noise of the photodetector, an increased signal-to-noise ratio due to more efficient laser diode optical pumping might improve the short term performance. Because the emission wavelength of the laser diode can be tuned, improved long term performance could be gained through the control of the light shift effect. However, due to the nature of the gas cell frequency standard, various physical phenomena are strongly coupled in their effect on the frequency output, and thus careful consideration must be given to any change in one parameter because of its interrelation with other parameters. Some investigations concerning the coupled effect of the optical and microwave fields in the rubidium atomic clock are reported. It is shown that this type of coupling is an important consideration for any attempt to incorporate a laser diode into a gas cell clock.

Camparo, J. C.↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiplexed structured imaging of laser induced fluorescence at 10 GHz rate

The frame rate of conventional high-speed imaging devices is limited by exposure time and signal read-out time. Structured imaging is able to push the frame rate beyond the limit of the imaging device. This work demonstrates the feasibility of potential TeraHz rate structured imaging with a multiplexed structured imaging setup. In this work, a multiplexed structured image capture system was employed to image UV laser induced krypton-II emission lines at 10 GHz. The measured emission intensity of the 764 nm line over time suggests a temporal resolution of 97 ps. The temporal resolution is adjustable, and the frame rate can be further increased to the TeraHz level.

47 OTHER INSTRUMENTATION↗

Phase-Dependent Squeezing in Dual-Comb Interferometry

Manipulating the quantum noise of continuous-wave lasers through squeezing has reshaped optical interferometry. However, progress in optical frequency comb interferometry with pulsed squeezed sources has been limited, despite the role of frequency combs in ultraprecise optical metrology. Here, we introduce a new time-domain approach to characterizing squeezed femtosecond light pulses using dual-comb interferometry. Time-domain interferograms are generated via multiheterodyne beating between the modes of a Kerr soliton-squeezed frequency comb and a coherent state comb. The interferogram noise reveals phase-dependent squeezing and antisqueezing, dipping as much as 3.8 ± 0.2 dB below the shot noise level at alternating zero crossings. We model this nonstationary quantum noise as a periodic optical displacement of the squeezed comb by the coherent comb. These results support a route toward quantum-enhanced dual-comb timing applications and high-speed quantum state tomography with dual-comb interferometers.

Herman, Daniel Issac [University of Colorado, Boul↗

Spectral shaping of an ultrafast ytterbium fiber laser via a passive intracavity optical filter: a simple and reliable route to sub-45 fs pulses

We investigate the use of passive intracavity optical filters for controlling the laser output spectrum of a polarization-mode-locked, ultrafast ytterbium fiber laser. The overall lasing bandwidth is increased or extended by strategic choice of the filter cutoff frequency. Overall laser performance, including pulse compression and intensity noise, is investigated for both shortpass and longpass filters with a range of cutoff frequencies. The intracavity filter not only shapes the output spectra, but also provides a route for overall broader bandwidths and shorter pulses in ytterbium fiber lasers. These results demonstrate that spectral shaping with a passive filter is a useful tool to routinely achieve sub-45 fs pulse durations in ytterbium fiber lasers.

Cooper, Nicholas D.↗

Modeling noise in global Mølmer-Sørensen interactions applied to quantum approximate optimization

Many-qubit Mølmer-Sørensen (MS) interactions applied to trapped ions offer unique capabilities for quantum information processing, with applications including quantum simulation and the quantum approximate optimization algorithm (QAOA). Here, we develop a physical model to describe many-qubit MS interactions under four sources of experimental noise: vibrational mode frequency fluctuations, laser power fluctuations, thermal initial vibrational states, and state preparation and measurement errors. The model parametrizes these errors from simple experimental measurements, without free parameters. Herein, we validate the model in comparison with experiments that implement sequences of MS interactions on two 171 Yb + ions. The model shows reasonable agreement after several MS interactions as quantified by the reduced chi-squared statistic $χ^{2}_{red}$≈2. As an application we examine MaxCut QAOA experiments on three and six ions. The experimental performance is quantified by approximation ratios that are 91% and 83% of the optimal theoretical values. Our model predicts $0.93^{+0.03}_{-0.02}$ and $0.95^{+0.04}_{-0.03}$, respectively, with disagreement in the latter value attributable to secondary noise sources beyond those considered in our analysis. With realistic experimental improvements to reduce measurement error and radial trap frequency variations, the model achieves approximation ratios that are 99% of the optimal. Incorporating these improvements into future experiments is expected to reveal new aspects of noise for future modeling and experimental improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

KrF laser-induced OH fluorescence imaging in a supersonic combustion tunnel

Planar fluorescence images of OH in a continuous-flow, electrical-resistively heated, high enthalpy, hydrogen-air combustion tunnel, induced by a tunable KrF laser, were recorded. These images were compared to previously recorded fluorescence images induced by a doubled-dye laser under similar conditions. Images induced by the doubled-dye laser system demonstrated a severe distortion caused by absorption and fluorescence trapping. By contrast, images of the fluorescence induced by the tunable KrF laser retained the symmetry properties of the flow. Based on signal-to-noise ratio measurements the yield of the fluorescence induced by the doubled-dye laser is larger than the fluorescence yield induced by the KrF laser. The measurements in the present facility of OH fluorescence induced by the KrF laser were limited by the photon-statistical noise. Based 2 on this result, doubled-dye laser systems are recommended for OH imaging in small and OH lean (less than 10 exp 15/cu cm) facilities. KrF lasers should be selected otherwise.

Quagliaroli, T. M.↗

A Chip-Scale Oscillation-Mode Optomechanical Inertial Sensor Near the Thermodynamical Limits

Modern navigation systems integrate the global positioning system (GPS) with an inertial navigation system (INS), which complement each other for correct attitude and velocity determination. Here, the core of the INS integrates accelerometers and gyroscopes used to measure forces and angular rate in the vehicular inertial reference frame. With the help of gyroscopes and by integrating the acceleration to compute velocity and distance, precision and compact accelerometers with sufficient accuracy can provide small–error location determination. Solid–state implementations, through coherent readout, can provide a platform for high performance acceleration detection. In contrast to prior accelerometers using piezoelectric or capacitive readout techniques, optical readout provides narrow–linewidth high–sensitivity laser detection along with low–noise resonant optomechanical transduction near the thermodynamical limits. Here an optomechanical inertial sensor with an 8.2 µg Hz –1/2 velocity random walk (VRW) at an acquisition rate of 100 Hz and 50.9 µg bias instability is demonstrated, suitable for applications, such as, inertial navigation, inclination sensing, platform stabilization, and/or wearable device motion detection. Driven into optomechanical sustained–oscillation, the slot photonic crystal cavity provides radio–frequency readout of the optically–driven transduction with an enhanced 625 µg Hz –1 sensitivity. Measuring the optomechanically–stiffened oscillation shift, instead of the optical transmission shift, provides a 220× VRW enhancement over pre–oscillation mode detection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Performance and wake flow characterization of a 1:8.7-scale reference USDOE MHKF1 hydrokinetic turbine to establish a verification and validation test database

As hydrokinetic turbine technologies continue to advance towards commercialization, public datasets on the performance characteristics for these devices and their flow field effects are invaluable to advance our understanding of these technologies and to validate analytical and numerical models. The Applied Research Laboratory at The Pennsylvania State University (ARL Penn State) collaborated with Sandia National Laboratories and the University of California at Davis to design, fabricate (at a 1:8.7 scale), and experimentally test a novel hydrokinetic turbine rotor design to provide an open platform and dataset for further study and development. The water tunnel test of this three-bladed, horizontal-axis rotor recorded power production, blade loading, the near-wake flow, cavitation effects, and noise generation. These state-of-the-art measurements demonstrate much of the complex physics associated with the flow through an unducted, horizontal-axis turbine, and they elucidate the performance characteristics and flow field effects at an unprecedented fidelity, accuracy and resolution. Measurements of powering coefficients (power, torque and thrust) as a function of tip-speed-ratio were performed. The dataset also includes unsteady measurements of driveshaft loading, blade strain, tower pressures, and radiated noise. Detailed flow mapping using laser Doppler velocimetry, and planar and stereo particle image velocimetry includes measurements of mean velocity and Reynolds stresses. Although the wake measurements are limited to less than half a diameter, they reveal the complex flow patterns in the near-wake structure of the rotor. The full database, available at the United States Department of Energy’s marine and hydrokinetic data repository, includes tunnel and model Computer Aided Design geometry files and inflow data sufficient for a “Model-the-Test” computational Verification and Validation study.

13 HYDRO ENERGY↗

A simulation of the San Andreas fault experiment

The San Andreas Fault Experiment, which employs two laser tracking systems for measuring the relative motion of two points on opposite sides of the fault, was simulated for an eight year observation period. The two tracking stations are located near San Diego on the western side of the fault and near Quincy on the eastern side; they are roughly 900 kilometers apart. Both will simultaneously track laser reflector equipped satellites as they pass near the stations. Tracking of the Beacon Explorer C Spacecraft was simulated for these two stations during August and September for eight consecutive years. An error analysis of the recovery of the relative location of Quincy from the data was made, allowing for model errors in the mass of the earth, the gravity field, solar radiation pressure, atmospheric drag, errors in the position of the San Diego site, and laser systems range biases and noise. The results of this simulation indicate that the distance of Quincy from San Diego will be determined each year with a precision of about 10 centimeters. This figure is based on the accuracy of earth models and other parameters available in 1972.

Agreen, R. W.↗

Optical communication with semiconductor laser diodes

A 25 megabit/sec direct detection optical communication system that used Q=4 PPM signalling was constructed and its performance measured under laboratory conditions. The system used a single-mode AlGaAs laser diode transmitter and low noise silicon avalanche photodiode (APD) photodetector. Comparison of measured performance with the theoretical revealed that modeling the APD output as a Gaussian process under conditions of negligible background radiation and low (less than 10 to the -12 power A) APD bulk leakage currents leads to substantial underestimates of optimal APD gain to use and overestimates of system bit error probability. A procedure is given to numerically compute system performance which uses the more accurate Webb's Approximation of the exact Conradi distribution for the APD ouput signal that does not require excessive amounts of computer time (a few minutes of VAX 8600 CPU time per system operating point). Examples are given which illustrate the breakdown of the Gaussian approximation in assessing system performance. This system achieved a bit error probability of 10 to the -6 power at a received signal energy corresponding to an average of 60 absorbed photons/bit and optimal APD gain of 700.

Davidson, F.↗

Altimetry and lidar using AlGaAs lasers modulated with pseudo-random codes

We have demonstrated a prototype laser altimeter and lidar which uses a low power AlGaAs laser modulated with a pseudorandom noise (PN) code, a 20 cm diameter telescope, and a photon counting receiver. Measurements to tree canopies over a 400 m horizontal path show strong signals with 5.3 mW average power and a 6.4 msec averaging time. Computer simulations predict lidar performance for various types of scattering performance.

Abshire, James B.↗