Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Two-electron interference in two-photon attosecond double ionization of neon

The pump-probe experiments enabled by x-ray free-electron lasers (XFEL) will allow us to directly observe correlated electronic motion with attosecond time resolution by detecting photoelectron pairs in coincidence. In helium, the transition between the nonsequential and sequential regime in two-photon double ionization (TPDI) is well explained by a virtual-sequential model. Much less is known, however, about the TPDI process in more complex atoms. Recently, we extended the virtual-sequential model to arbitrary light pulses [Chattopadhyay Phys. Rev. A 108, 013114 (2023)]. This extension employs multichannel scattering states for the single ionization of both the neutral and the ionized target, which we initially applied to helium. In the present study, we show that our extended virtual-sequential model reproduces the qualitative features of the angularly integrated observables with available experimental results for neon, a considerably more complex target. We observe an intriguing feature of inverted two-particle interference in the joint-energy distribution of Ne compared to He. Finally, this phenomenon, attributable to the presence of a final doubly ionized state with triplet symmetry coupled to the two photoelectrons, should be observable with current experimental technologies.

74 ATOMIC AND MOLECULAR PHYSICS↗

Application of High-Spatial Resolution LA-MC-ICP-MS in Planetary Materials

High-precision stable and radiogenic isotopic measurements of planetary materials can help elucidate processes taking place during early Solar System formation, as well as during subsequent planetary differentiation. Laser Ablation Multi Collector Inductively Coupled Plasma Mass Spectrometry (LA-MC-ICP-MS) adds the valuable ability of preserving the spatial context of these isotopic measurements, by sampling small sample volumes (~10 – 60 um diameter) using a pulsed laser system. In the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center, these in-situ isotopic measurements are primarily made using the Applied SpectraTM iX-fs-Tandem LA-LIBS Instrument coupled to the Nu InstrumentsTM SP1700 MC-ICP-MS. The instrumental set-up also provides simultaneous Laser Induced Breakdown Spectroscopy (LIBS) measurements and the potential use of a low energy path with a collision/reaction cell for additional interference removal, though we focus here on the typical high-energy LA-MC-ICP-MS operation. We will provide examples of stable (e.g., Mg) and radiogenic (e.g., Lu-Hf) isotopic systems measured in planetary materials and their terrestrial analogs. The measurement of mass dependent Mg isotopic variations is an important tool for reconstructing processes such as evaporation and condensation of solids in the solar nebula. For early Solar System samples, Mg isotope measurements are also important for the short-lived (t1/2 = 0.7 Ma) Al-Mg chronometer. During laser ablation analyses, the measurement of the Al-Mg isotopic system is made in medium mass resolution (RP ~9500 at ~20% transmission) to limit interferences from 48Ti2+ and 48Ca2+ on 24Mg+, in addition to 52Cr2+ and 12C14N+ on 26Mg+. Measured in the mineral zircon, the 176Lu-176Hf decay system is often used for understanding the growth of continents on Earth, and is also a vital aid in deciphering early large-scale planetary differentiation processes, such as the crystallization of the lunar magma ocean, which is thought to be responsible for much of the Moon’s crust. Lu-Hf measurements are made in low resolution mode (RP <2000), with 10 ion masses (from 171Yb to 180Hf) measured simultaneously to facilitate corrections for isobaric interferences from 176Yb and 176Lu on 176Hf.

Jacob B Setera↗

Optical Monitoring of Weld Penetration

Robotic welding controlled by reliable, relatively-noise-free optoelectronic unit. Bounding off meniscus of pool of molten metal, laser beam impinges on position-sensitive photodetector. Beam diameter adjusted for width of weld. Optical filters screen out light from arc. Made from small, low-cost components and utilizing optical fibers to conduct signals, system immune to electromagnetic interference common in industrial environments. Aimed for automatic welders, robot welders in particular and also adaptable to other types of welding, including tungsten/inert-gas, laser, and electron-beam techniques.

Maram, J.↗

Generation of multiple attosecond sub-bursts in femtosecond pulse trains by long-wavelength driving lasers

High-order harmonics generated by a long intense femtosecond laser are known experimentally to create attosecond pulse trains (APTs). In the time domain, an APT consists of a sequence of sharp attosecond bursts that are equally separated by each half optical cycle. Here, in this work, we show that such well-known features can be modified when a longer wavelength driving laser is used. From our simulations, we show that multiple shorter attosecond sub-bursts exist in the femtosecond pulse train within each half optical cycle and the duration of each sub-burst scales approximately as $λ^{–2}_0$ with the driving laser wavelength λ 0 . We show that such sub-bursts can be found using quantitative rescattering model for harmonics generated from a single atom, and their origin is due to the interference of the quantum orbits from first two returns of the recombining electron. We further show that such sub-bursts can be phase matched under proper laser focusing condition and the position of the gas cell, thus, such new features should be observable experimentally.

47 OTHER INSTRUMENTATION↗

Experimental studies of the formation/deposition of sodium sulfate in/from combustion gases

Interference in a reflected beam of monochromatic light from a linearly polarized helium-neon laser was used to determine the dew point and deposition rate of B2O3 on a heated platinum target. Preliminary results at different BCl3 seed levels, except for one flow velocity and equivalence ratio (.813) are presented and discussed. Alkali chloride reactions with atomic oxygen were also investigated. Readily detectable Na*(g) and K*(g) - atoms were observed in emission at 589 nm, 766nm, 796nm, respectively.

Rosner, D. E.↗

Residual interference and wind tunnel wall adaption

Measured flow variables near the test section boundaries, used to guide adjustments of the walls in adaptive wind tunnels, can also be used to quantify the residual interference. Because of a finite number of wall control devices (jacks, plenum compartments), the finite test section length, and the approximation character of adaptation algorithms, the unconfined flow conditions are not expected to be precisely attained even in the fully adapted stage. The procedures for the evaluation of residual wall interference are essentially the same as those used for assessing the correction in conventional, non-adaptive wind tunnels. Depending upon the number of flow variables utilized, one can speak of one- or two-variable methods; in two dimensions also of Schwarz- or Cauchy-type methods. The one-variable methods use the measured static pressure and normal velocity at the test section boundary, but do not require any model representation. This is clearly of an advantage for adaptive wall test section, which are often relatively small with respect to the test model, and for the variety of complex flows commonly encountered in wind tunnel testing. For test sections with flexible walls the normal component of velocity is given by the shape of the wall, adjusted for the displacement effect of its boundary layer. For ventilated test section walls it has to be measured by the Calspan pipes, laser Doppler velocimetry, or other appropriate techniques. The interface discontinuity method, also described, is a genuine residual interference assessment technique. It is specific to adaptive wall wind tunnels, where the computation results for the fictitious flow in the exterior of the test section are provided.

Mokry, Miroslav↗

Noise in Intense Electron Bunches (Final Technical Report)

The goal of this project is to investigate density fluctuations in electron bunches. Noise and density fluctuations in relativistic electron bunches, accelerated in a linac, are of critical importance to various Coherent Electron Cooling (CEC) concepts as well as to free-electron lasers (FELs). For CEC, the beam noise results in additional diffusion that counteracts cooling; and if this noise is not controlled at sufficiently low level, the noise heating effects can overcome cooling. There have been several proposals in the past to suppress the noise in the beam in the frequency range of interest in order to optimize the cooling effects. In SASE FELs a microwave instability starts from the initial noise in the beam and eventually leads to the beam microbunching yielding coherent radiation, and the initial noise in the FEL bandwidth plays a useful role. In seeded FELs, in contrast, such noise interferes with the seed signal, so that reducing noise at the initial seed wavelength would lower the seed laser power requirement. Our major goals were (1) to measure the electron beam density noise level in a 0.5 – 10 um wavelength range, (2) to predict the beam noise level in order to compare with the measurements, and (3) as a stretch goal, to find mechanisms that affect the beam noise to control its level in a predictable manner.

43 PARTICLE ACCELERATORS↗

Optical interference effect in strong-field electronic coherence spectroscopy

Here, we investigate strong-field-induced electronic coherences in argon and molecular nitrogen ions created by high-intensity, few-cycle infrared laser pulses. This is a step toward the long-sought goal of strong-field coherent control in molecular chemistry. We employ high-intensity, few-cycle infrared laser pulses in a pump-probe setup to investigate a recent prediction that electronic coherences in nitrogen molecules change the ion yields versus pump-probe delay. [Yuen et al., Phys. Rev. A 109, L011101 (2024)]. The predicted coherence signals in molecular nitrogen could not be resolved above the optical interference of the pump and probe pulses; a simultaneous measurement clearly resolved the induced cation fine-structure coherence in strong-field-ionized argon. The results of our comparison with simulations suggest that optical interference effects manifest differently in each ionic species and must be carefully accounted for when interpreting experimental data. We find that nonsequential double ionization in the low-intensity region of the focal volume can reduce the visibility of coherence generated by two-pulse sequential ionization, and we quantify the importance of pulse shape and spectral characteristics for isolating the desired coherence signals.

charge migration↗

Mutual Diffusion Coefficients and Refractive Index Increments of K 2 SO 4 (aq) at 298.15 K from Rayleigh Interferometry

Here, isothermal mutual diffusion coefficients (interdiffusion coefficients) were measured for K 2 SO 4 (aq) at 298.15 ± 0.005 K, at numerous concentrations ranging from dilute solutions to near saturation (0.59648 mol∙dm -3 ; 0.61349 mol∙kg -1 ) under free diffusion boundary conditions, using high precision Rayleigh interferometry. Under the experimental conditions these diffusion coefficients are on the volume-fixed reference frame D v . Two series of experiments were performed, the first using the traditional experimental approach with a mercury lamp source and with the interference patterns being recorded on glass photographic plates, and the second with a He-Ne laser light source and computerized data acquisition using a photodiode array. The results from both series of experiments are in excellent agreement, and generally yield diffusion coefficients precise to at least 0.002 x 10 -9 m 2 ∙s 1 (0.15% to 0.19%) and in most cases to 0.001 x 10 -9 m 2 ∙s -1 (0.07% to 0.1%). These experiments also yield accurate values of the refractive index differences for the solution pairs used in the diffusion experiments. The new diffusion coefficients are compared to two sets of published values of diffusion coefficients for K 2 SO 4 (aq) which are somewhat discrepant from each other. This study extends and complements our earlier work on the diffusion coefficients of the most common brine salts: NaCl(aq), KCl(aq), MgCl 2 (aq), CaCl 2 (aq), Na 2 SO 4 (aq), ] MgSO 4 (aq), NaHCO 3 (aq), and KHCO 3 (aq) at 298.15 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Room-Temperature Optical Detection of 14 CO 2 below the Natural Abundance with Two-Color Cavity Ring-Down Spectroscopy

Radiocarbon’s natural production, radiative decay, and isotopic rarity make it a unique tool to probe carbonaceous systems in the life and earth sciences. However, the difficulty of current radiocarbon ( 14 C) detection methods limits scientific adoption. Here, two-color cavity ring-down spectroscopy detects 14 CO 2 in room-temperature samples with an accuracy of one-tenth the natural abundance in 3 min. The intracavity pump–probe measurement uses two cavity-enhanced lasers to cancel out cavity ring-down rate fluctuations and strong one-photon absorption interference (>10 000 1/s) from hot-band transitions of CO 2 isotopologues. Selective, room-temperature detection of small 14 CO 2 absorption signals (<1 1/s) reduces the technical and operational burdens for cavity-enhanced measurements of radiocarbon, which can benefit a wide range of applications like biomedical research and field-detection of combusted fossil fuels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculations of transonic flow about an airfoil in a wind tunnel

A combined experimental and numerical study was performed to include wind-tunnel wall interference effects in calculations for airfoil flows at transonic speeds. Pressure-survey-tube and laser-Doppler velocimeter measurements were made in the flow field about an airfoil in the 2- by 2-Foot Transonic Wind Tunnel at Ames Research Center. The results were then used as boundary data in a Navier-Stokes code modified by incorporating a pressure condition on the upper and lower computational boundaries. Comparison of calculated results and experimental data obtained from the surface of the airfoil indicates that the pressure-boundary condition is particularly effective in moving the shock to a position near that observed experimentally when the flow remains attached. For flows with large separation, shock position and viscous-layer properties are not well predicted, principally because of the inadequacies of the algebraic turbulence models employed with the method.

King, L. S.↗

Detection of tropospheric OH and HO2 by laser-induced fluorescence at low pressure using the 308nm excitation of OH

Laser-induced fluorescence (LIF) spectroscopy is a highly sensitive method for the direct in situ measurement of hydroxyl concentrations in the atmosphere. Its sensitivity and selectivity relies on the intense discrete UV-absorption lines of OH which are strongest around 282nm and 308nm. We have developed a LIF-instrument based on the low-pressure experiment (FAGE). However, we use 308nm instead of 282nm as excitation wavelength for OH, a concept that is also pursued by other groups. One advantage of the longer excitation wavelength is the higher detection sensitivity due to the about 6 times larger effective OH-fluorescence cross-section. Moreover, the O3/H2O-interference (OH self-generation by the laser) is about a factor of 200 smaller at 308nm than at 282nm. This keeps the interference level well below the projected detection limit of 10(exp 5) OH/cm(exp 3). Atmospheric HO2-radicals are detected by chemical conversion of HO2 into OH with NO.

Hofzumahaus, Andreas↗

AROTEL Temperature Retrievals Within PSC's Using Raman Scattering

NASA Goddard Space Flight Center's Airborne Raman Ozone Temperature Lidar (AROTEL) made temperature retrievals within Polar Stratospheric Clouds (PSCs) on several flights during the SAGE III Ozone Loss and Validation Experiment (SOLVE) campaign. The location of the PSCs was confirmed using simultaneously acquired data from the NASA Langley Aerosol lidar. Retrievals were made on flight dates 991207, 991210 and 000127 from just above the aircraft to 25 kilometers geometric altitude. Raman temperature retrievals are, to first order, insensitive to Mie interference because the Raman signals are red shifted by 2331 cm(exp -1) from the initial laser wavelength. Backscattering from clouds and aerosols is consequently not observed by the detector; however, extinction does impact the measurement and limits retrievals to optically thin clouds. Comparisons between retrievals employing Rayleigh and Raman scattering show the Raman temperatures to be significantly warmer than those employing Rayleigh scattering. Uncertainties are a function of altitude: at 25 km they were approximately 3 K. Temperature profiles could not be retrieved for optically thick clouds.

Burris, John↗

New Glass Serves as Window to Cutting-edge Lasers

Since 1997, Marshall Space Flight Center s Electrostatic Levitator (ESL) facility has been used to study the characteristics of new metals, ceramics, and glass compounds - in both their hot molten states and as they are cooled to form solid materials. The ESL provides a unique way to test such substances without having to make contact with a container or crucible that would contaminate the sample. Simply put, objects analyzed in the levitator's chamber float in mid-air with no visible means of support or containment, suspended only by static electricity. While a sample object is levitated, a laser beam heats it until it melts so that scientists can measure its physical properties without interference from a container.

Source record↗

Response of Solid He-4 to External Stress: Interdigital Capacitor Solid Level Detector and Optical Interferometer

Two experiments are being conducted to observe the liquid/solid interface of He-4 near 1 K. Interesting instabilities are expected to occur when the solid is non-hydrostatically stressed. (1)A compact interdigital capacitor is used as a level detector to observe solid He-4 to which stresses are applied externally. The capacitor consists of 38 interlaced 50 m wide and 3.8 mm long gold films separated by 50 m and deposited onto a 5 mm by 5 mm sapphire substrate. The capacitor is placed on one flat end wall of a cylindrical chamber (xx mm diameter and xx mm long). The solid is grown to a known height and a stress is applied by a tubular PZT along the cylindrical axis. The observed small change in height of the solid at the wall is linearly proportional to the applied stress. The solid height decreases under compressive stress but does not change under tensile stress. The response of the solid on compressive stress is consistent with the expected quadratic dependence on strain. (2)Interferometric techniques are being developed for observing the solid He-4 surface profile. A laser light source is brought into the low temperature region via single mode optical fiber. The interference pattern is transmitted back out of the low temperature apparatus via optical fiber bundle. The solid He-4 growth chamber will be equipped with two PZT's such that stress can be applied from orthogonal directions. Orthogonally applied stress is expected to induce surface instability with island-like deformation on a grid pattern. Apparatus design and progress of its construction are described.

Fay, J.↗

Fused silica diaphragm module for high temperature pressure transducers

A high temperature pressure transducer and sensing apparatus to determine the deflection of the transducer diaphragm is disclosed. The pressure transducer utilizes a fused silica diaphragm (12) which is illuminated at selected locations by a coherent laser source (52) via optical fibers (38, 46). The light reflected by the diaphragm (12) forms interference fringe patterns which are focused by gradient index rod lenses (36) on the ends of optical fibers (40, 48) for transmission to a fringe counting circuit (54). By digital techniques, the fringe count is converted into a determination of diaphragm deflection.

Berthold, III, John W.↗

Five-Channel Infrared Laser Absorption Spectrometer for Combustion Product Monitoring Aboard Manned Spacecraft

Continuous combustion product monitoring aboard manned spacecraft can prevent chronic exposure to hazardous compounds and also provides early detection of combustion events. As future missions extend beyond low-Earth orbit, analysis of returned environmental samples becomes impractical and safety monitoring should be performed in situ. Here, we describe initial designs of a five-channel tunable laser absorption spectrometer to continuously monitor combustion products with the goal of minimal maintenance and calibration over long-duration missions. The instrument incorporates dedicated laser channels to simultaneously target strong mid-infrared absorption lines of CO, HCl, HCN, HF, and CO2. The availability of low-power-consumption semiconductor lasers operating in the 2 to 5 micron wavelength range affords the flexibility to select absorption lines for each gas with maximum interaction strength and minimal interference from other gases, which enables the design of a compact and mechanically robust spectrometer with low-level sensitivity. In this paper, we focus primarily on absorption line selection based on the availability of low-power single-mode semiconductor laser sources designed specifically for the target wavelength range.

Briggs, Ryan M.↗