Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “krypton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Observation and diagnostic application of Kr K-shell emission in magnetized liner inertial fusion experiments at Z

In a series of Magnetized Liner Inertial Fusion (MagLIF) experiments performed at the Z pulsed power accelerator of Sandia National Laboratories, beryllium liners filled with deuterium gas pressures in the 4–8 atm range and a tracer amount of krypton were imploded. At the collapse of the cylindrical implosion, temperatures in the 1–3 keV range and atom number densities of ∼1023 cm−3 were expected. The plasma was magnetized with a 10 T axial magnetic field. Krypton was added to the fuel for diagnosing implosion plasma conditions. Krypton K-shell line emission was recorded with the CRITR time-integrated transmission crystal x-ray spectrometer. The observation shows n = 2 to n = 1 line emissions in B-, Be-, Li-, and He-like Kr ions and is characteristic of the highest electron temperatures achieved in the thermonuclear plasma. Detailed modeling of the krypton atomic kinetics and radiation physics permits us to interpret the composite spectral feature, and it demonstrates that the spectrum is temperature sensitive. We discuss temperatures extracted from the krypton data analysis for experiments performed with several filling pressures.

Clapp, J. T. (ORCID:0000000219928146)↗

Molecular dynamics simulation of framework flexibility effects on noble gas diffusion in HKUST-1 and ZIF-8

Molecular dynamics simulations were used to investigate trends in noble gas (Ar, Kr, Xe) diffusion in the metal-organic frameworks HKUST-1 and ZIF-8. Diffusion occurs primarily through inter-cage jump events, with much greater diffusion of guest atoms in HKUST-1 compared to ZIF-8 due to the larger cage and window sizes in the former. We compare diffusion coefficients calculated for both rigid and flexible frameworks. For rigid framework simulations, in which the framework atoms were held at their crystallographic or geometry optimized coordinates, sometimes dramatic differences in guest diffusion were seen depending on the initial framework structure or the choice of framework force field parameters. When framework flexibility effects were included, argon and krypton diffusion increased significantly compared to rigid-framework simulations using general force field parameters. Additionally, for argon and krypton in ZIF-8, guest diffusion increased with loading, demonstrating that guest-guest interactions between cages enhance inter-cage diffusion. No inter-cage jump events were seen for xenon atoms in ZIF-8 regardless of force field or initial structure, and the loading dependence of xenon diffusion in HKUST-1 is different for rigid and flexible frameworks. Diffusion of krypton and xenon in HKUST-1 depends on two competing effects: the steric effect that decreases diffusion as loading increases, and the “small cage effect” that increases diffusion as loading increases. Finally, a detailed analysis of the window size in ZIF-8 reveals that the window increases beyond its normal size to permit passage of a (nominally) larger krypton atom.

36 MATERIALS SCIENCE↗

Investigation of Sampling-Probe Distorted Temperature Fields with X-Ray Fluorescence Spectroscopy

Flame-sampling experiments, especially in conjunction with laminar low-pressure premixed flames, are routinely used in combustion chemistry studies to unravel the identities and quantities of key intermediates and their pathways. In many instances, however, an unambiguous interpretation of the experimental and modeling results is hampered by the uncertainties about the probe-induced, perturbed temperature profile. To overcome this limitation, two-dimensional perturbations of the temperature field caused by sampling probes with different geometries have been investigated using synchrotron-based X-ray fluorescence spectroscopy. In these experiments, which were performed at the 7-BM beamline of the Advanced Photon Source (APS) at the Argonne National Laboratory, a continuous beam of hard X-rays at 15 keV was used to excite krypton atoms that were added in a concentration of 5 vol.-% to the unburnt gas mixture and the resulting krypton fluorescence at 12.65 keV was subsequently collected. The highly spatially resolved signal was converted into the local flame temperature to obtain temperature fields at various burner-probe separations as functions of the distance to the burner surface and the radial distance from the centerline. Multiple measurements were performed with different probe geometries and because of the observed impact on the temperature profiles the results clearly revealed the need to specify the sampling probe design to enable quantitative and meaningful comparisons of modeling results with flame-sampled mole fraction data. (C) 2018 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Hansen, N.↗

Self-assembly of solid nanoclusters in molybdenum under gas ion implantation

The self-assembly of defects in materials could create unique physical and chemical properties. In nuclear fuels, the formation of self-assembled fission products mitigates fission-gas-release and swelling. In this work, we report the formation of a solid nanocluster superlattice in molybdenum, an important constituent in metallic fuels, under krypton gas ion implantation. X-ray absorption near edge structure measurements coupled with density functional theory calculations show that the pressure of krypton nanoclusters in molybdenum is ~2 GPa and molecular dynamic simulations reveal that the krypton atoms are solid in the nanoclusters with a krypton-to-vacancy ratio of ~0.28 at 300 K.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Xenon Fractionation and Archean Hydrogen Escape

Xenon is the heaviest gas found in significant quantities in natural planetary atmospheres. It would seem the least likely to escape. Yet there is more evidence for xenon escape from Earth than for any element other than helium and perhaps neon. The most straightforward evidence is that most of the radiogenic Xe from the decay of (129)I (half-life 15.7 Myr) and (244)Pu (half-life 81 Myr) that is Earth's birthright is missing. The missing xenon is often attributed to the impact erosion of early atmospheres of Earth and its ancestors. It is obvious that if most of the radiogenic xenon were driven off by impacts, most of the rest of the atmophiles fared the same fate. The other line of evidence is in the nonradiogenic isotopes of xenon and its silent partner, krypton. Atmospheric xenon is strongly mass fractionated (at about 4% per amu) compared to any known solar system source (Figure 1). This is in stark contrast to krypton, which may not be fractionated at all: atmospheric Kr is slightly heavier than solar Kr (at about 0.5% per amu), but it is the same as in carbonaceous chondrites. Nonradiogenic xenon is also under abundant relative to krypton (the so-called "missing xenon" problem). Together these observations imply that xenon has been subject to fractionating escape and krypton not.

magnetic fields↗

Ultra-Sensitive Collinear Fast Ion Beam Trace Detection of {sup 85}Kr

A novel scheme of collinear fast beam laser spectroscopy for the detection of the long lived rare isotope {sup 85}Kr by observing the optical hyperfine structure spectrum is presented. The technique utilizes cascade two-step excitation to pump metastable krypton atoms to a high-lying Rydberg level. The present work on krypton was motivated by the fact that {sup 85}Kr is a major tracer gas for exploring the reservoir structure of large oil fields. {sup 85}Kr detection in ambient air is also of importance for monitoring nuclear activities on a world wide scale. The technique has been successfully applied to stable krypton isotopes and to {sup 85}Kr. The selectivity is at the one part in 10{sup 10} level and the sensitivity at a few hundred ions/s.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ellipsometry with polarisation analysis at cryogenic temperatures inside a vacuum chamber

In this paper we describe a new variant of null ellipsometry to determine thicknesses and optical properties of thin films on a substrate at cryogenic temperatures. In the PCSA arrangement of ellipsometry the polarizer and the compensator are placed before the substrate and the analyzer after it. Usually, in the null ellipsometry the polarizer and the analyzer are rotated to find the searched minimum in intensity. In our variant we rotate the polarizer and the compensator instead, both being placed in the incoming beam before the substrate. Therefore the polarisation analysis of the reflected beam can be realized by an analyzer at fixed orientation. We developed this method for investigations of thin cryogenic films inside a vacuum chamber where the analyzer and detector had to be placed inside the cold shield at a temperature of T≈ 90 K close to the substrate. All other optical components were installed at the incoming beam line outside the vacuum chamber, including all components which need to be rotated during the measurements. Our null ellipsometry variant has been tested with condensed krypton films on a highly oriented pyrolytic graphite substrate (HOPG) at a temperature of T≈ 25 K. We show that it is possible to determine the indices of refraction of condensed krypton and of the HOPG substrate as well as thickness of krypton films with reasonable accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of fission product release predictions using PARFUME with results from the AGR-1 safety tests

Safety tests were conducted on fuel compacts from AGR-1, the first irradiation experiment of the Advanced Gas Reactor (AGR) Fuel Development and Qualification program, at temperatures ranging from 1600 to 1800 °C to determine fission product release at temperatures that bound reactor accident conditions. The PARFUME (PARticle FUel ModEl) code was used to predict the release of fission products silver, cesium, strontium, and krypton from fuel compacts containing tristructural isotropic (TRISO) coated particles during 15 of these safety tests. Comparisons between PARFUME predictions and post-irradiation examination results of the safety tests were conducted on two types of AGR-1 compacts: compacts containing only intact particles and compacts containing one or more particles whose SiC layers failed during safety testing. In both cases, PARFUME globally over-predicted the experimental release fractions by several orders of magnitude: more than three (intact) and two (failed SiC) orders of magnitude for silver, more than three and up to two orders of magnitude for strontium, and up to two and more than one orders of magnitude for krypton. The release of cesium from intact particles was also largely over-predicted (by up to five orders of magnitude) but its release from particles with failed SiC was only over-predicted by a factor of about 3. These over-predictions can be largely attributed to an over-estimation of the diffusivities used in the modeling of fission product transport in TRISO-coated particles. The integral release nature of the data makes it difficult to estimate the individual over-estimations in the kernel or each coating layer. Nevertheless, a tentative assessment of correction factors to these diffusivities was performed to enable a better match between the modeling predictions and the safety testing results. The method could only be successfully applied to silver and cesium. In the case of strontium, correction factors could not be assessed because potential release during the safety tests could not be distinguished from matrix content released during irradiation. Furthermore, in the case of krypton, all the coating layers are partly retentive and the available data did not allow the level of retention in individual layers to be determined, hence preventing derivation of any correction factors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detecting Clandestine Reprocessing Activities in the Middle East

Nuclear reprocessing plants release krypton-85 that can be detected in the atmospheric air downwind from the facility. Atmospheric transport modelling is applied to determine the area over which krypton-85 emissions from undeclared reprocessing activities in the Middle East would still be detectable against the background. This is used to assess the feasibility of monitoring known reprocessing plants and detecting unknown reprocessing plants. The annual wind flow over Dimona is analyzed and it is concluded that a known reprocessing plant could be monitored with one or a few fixed monitoring stations. Unknown reprocessing plants are more difficult to detect due to the high background levels of krypton-85 and fixed stations would not be feasible. Instead, the number of air samples that have to be taken at random locations for a successful detection is calculated. Taking random air samples can present a logistical effort but can yield reliable and timely detection of clandestine reprocessing plants. This could be used for verification of an international treaty that prohibits the separation of plutonium in the Middle East.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Characterization and controllability of radiated power via extrinsic impurity seeding in strongly negative triangularity plasmas in DIII-D

Experiments with extrinsic impurity seeding in strongly negative triangularity shapes in DIII-D achieved radiated power fractions (relative to input power) of up to ≈85% total radiation and ≈55% core radiation in steady-operating conditions. The relationship between core and total radiation was sensitive to impurity species and input power. Attempts to reach higher radiation levels via higher impurity flows resulted in radiative collapse disruptions. Nitrogen, neon, argon, and krypton were tested. Injection was by gas puffing, usually controlled by feeding back real-time estimates for core or total radiating fractions ($P_\textrm{rad} / P_\textrm{input}$). Argon and krypton were controlled by feeding back total radiating fraction, whereas neon was controlled by feeding back the core radiating fraction, due to the lower efficiency of neon as a divertor radiator. Nitrogen flows were pre-programmed. Reasonable total $P_\textrm{rad}$ control target following was achieved with argon or krypton. Control was more challenging with the neon/core radiation configuration, which was more prone to slow response and overshooting of the control target. Poor particle removal contributed to the control challenge: neon particle inventory within the last closed flux surface was roughly constant for up to 1 s (the longest duration tested) after neon injection was halted. However, separate experiments with laser-blow off of non-recycling impurities measured a short impurity confinement time, on the scale of the energy confinement time of ∼100 ms. Modeling with the Aurora impurity transport simulation matched experimental neon density profiles with full recycling (R = 1.0) and weak pumping but predicted rapid decreases in neon inventory if pumping were increased or recycling decreased. This indicates that changes outside the confined plasma (adding a well-placed pump) would improve controllability for all highly recycling species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power and isotope effects in the ITER baseline scenario with tungsten and tungsten-equivalent radiators in DIII-D

Abstract Experiments in DIII-D document the ITER Baseline Scenario (IBS) at q 95 ∼ 3 and P IN / P LH ∼ 1–2, in both deuterium and hydrogen utilizing Kr and Xe as Tungsten-equivalent radiators. The power threshold for H-mode operation ( P LH ) was determined experimentally without added impurities and found to be about a factor of two higher than the scaling law. In recent IBS experiments in deuterium, intrinsic levels of metals such as Tungsten (W) or molybdenum and inconel are present that reduce the pedestal pressure by 20%–25%. A complete radiative collapse of deuterium IBS plasmas occurs at W core concentrations C W = 10 −5 . Simulations show that for core temperatures expected for ITER, the plasmas would not have a radiative collapse at C W = 1 × 10 −5 , moreover Q = 8–10 would still be achieved for C W up to 3 × 10 −5 . In contrast to deuterium, the IBS in hydrogen is not affected by intrinsic high-Z impurities, indicating that hydrogen H-modes in ITER may not inform the D-T phase with respect to W accumulation and discharge survival. Compared to deuterium, the pedestal pressure in hydrogen is ∼25% lower, with much higher ELM frequency of 150 Hz, decreasing with input power. Krypton was injected in a matrix scan of input power and impurity flow in IBS hydrogen discharges. Krypton impurity density profiles in hydrogen are similar to deuterium plasmas, but at Kr flows that are 2–3 times higher for the same input power. Krypton is transported into the core and affects the whole radius; at the highest injection rates a radiative collapse occurs at core radiation fractions of 0.3–0.35, consistent with the expected maximum W radiation fraction for ITER core plasmas. Comparing the results with previous International Tokamak Physics Activity database studies of the IBS confirms that at higher radiation fraction due to high-Z impurities, a drop in H 98 of >10% is observed. On the other hand, the results using Kr as a W-equivalent radiator indicate that metal (W) devices at lower core temperatures than ITER may provide overly pessimistic performance extrapolations to ITER for deuterium-tritium operation. The new DIII-D results support a more attractive option for the ITER Research Plan with a short hydrogen phase for system commissioning, transitioning to deuterium operations as soon as possible to provide relevant conditions for deuterium-tritium operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coulomb excitation of 80,82 Kr and a change in structure approaching N = Z = 40

Nuclei approaching N = Z = 40 are known to exhibit strongly deformed structures and are thought to be candidates for shape coexistence. In the krypton isotopes, 80,82 Kr are poorly characterized, preventing an understanding of evolving deformation approaching N = 40. The present work aims to determine electric quadrupole transition strengths and quadrupole moments of 80,82 Kr in order to better characterize their deformation. Sub-barrier Coulomb excitation was employed, impinging the isotopes of krypton on 196 Pt and 208 Pb targets. Utilizing a semiclassical description of the safe Coulomb-excitation process E 2 matrix elements could then be determined. Eleven new or improved matrix elements are determined in 80 Kr and seven in 82 Kr . The new B(E2;0$^+_1$ → 2$^+_1$ ) value in 82 Kr disagrees with the evaluated value by 3σ , which can be explained in terms of deficiencies in a previous Coulomb-excitation analysis. Conclusions: Comparison of measured Q s ( 2$^+_1$ ) and B(E2; 0$^+_1$ → 2$^+_1$ ) values indicates that neutron-deficient ( N ≤ 42 ) isotopes of krypton are closer to axial deformation than other isotopic chains in the mass region. A continuation of this trend to higher Z may result in Sr and Zr isotopes exhibiting near-axial prolate deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First-principles determination of the phonon-point defect scattering and thermal transport due to fission products in ThO 2

This work presents the first-principles calculations of the lattice thermal conductivity degradation due to point defects in thorium dioxide using an iterative solution of the Pierels-Boltzmann transport equation. We have used the non perturbative Green’s function methodology to compute the phonon- point defect scattering rates that consider the local distortion around the point defect, including the mass difference changes, interatomic force constants, and structural relaxation near the point defects. The point defects considered in this work include the vacancy of thorium ($V$ $TH$ ) and oxygen ($V$ $O$ ), substitutions of helium ($He$ $Th$ ), krypton ($Kr$ $Th$ ), zirconium ($Zr$ $Th$ ), iodine ($I$ $Th$ ) and xenon ($Xe$ $Th$ ) in the thorium site, and the three different configurations of the Schottky defects. The results of the phonon-defect scattering rate reveal that, among all the considered intrinsic defects, the thorium vacancy and helium substitution in the thorium site scatter the phonon most due to the substantial changes in the force constant and structural distortions. The scattering of phonons due to the substitutional defects unveils that the zirconium atom scatters phonons the least, followed by xenon, iodine, krypton, and helium. This is contrary to the intuition that the scattering strength follows $He$ $Th$ > $Kr$ $Th$ > $Zr$ $Th$ > $I$ $Th$ > $Xe$ $Th$ based on the mass difference. This striking difference in the zirconium phonon scattering is due to the local chemical environment changes. Zirconium is an electropositive element with valency similar to thorium and, therefore, can bond with the oxygen atoms, thus creating less force constant variance compared to iodine, an electronegative element noble gas helium, xenon, and krypton. In conclusion, these results can serve as the benchmark for the analytical models and help the engineering-scale modeling effort for nuclear design.

36 MATERIALS SCIENCE↗

Performance Criteria for Capture and/or Immobilization Technologies (Revision 1)

The capture and subsequent immobilization of regulated volatile radionuclides from the off-gas streams of a used nuclear fuel (UNF) reprocessing facility has been a topic of substantial research interest for the US Department of Energy and its international counterparts. Removal of specific radionuclides from the plant effluent streams before discharge to the environment is required to meet regulations set forth by the US Environmental Protection Agency. Upon removal, the radionuclides, as well as associated sorbents that cannot be regenerated in a cost-effective manner, are destined for conversion to a waste form. Research in separation and capture methodologies has included a wide range of technology types, and studies of waste forms are correspondingly diverse. In considering the future development and implementation of both sorbents and waste forms, it is necessary to identify benchmark measures of performance to objectively evaluate each sorbent system or waste form. Sets of performance criteria and associated metrics have been developed for sorbent and waste form evaluation. These criteria address physical, radiological, and chemical characteristics, technical practicality, technical maturity, cost, and, for sorbents, system performance. The criteria and metrics appear to be robust and should be applicable despite the eventual waste classification (as either high- or low-level waste). They are flexible enough to address both aqueous reprocessing and electrochemical reprocessing of UNF. These criteria sets can serve as tools to evaluate performance at multiple stages within the development process, and in this revision (Revision 1) they have been used to assess technologies relating to krypton/xenon separations and iodine capture from off-gas streams arising from UNF reprocessing. Assessment of krypton/xenon separations using engineered forms of two zeolite minerals (silver mordenite and hydrogen mordenite in a polyacrylonitrile-based binder [AgZ-PAN/HZ-PAN]) found that the zeolite-based separation is relatively advanced in its development, but several key issues require resolution. First, desorption processes for both krypton and xenon require refinement to provide an understanding of the product purity that can be achieved. Second, adsorption rate data is needed in order to calculate the bed depth required for effective separation. Finally, it is strongly recommended that a technical review of krypton/xenon separation by AgZ-PAN/HZ-PAN be performed to synergize available data and assess the cost savings and operational benefits that may be realized from implementation of this technology. Assessment of metal organic frameworks (MOFs) for their use in the separation of krypton/xenon found that the ideal separation would be performed using a single-column system with a MOF selective for krypton over xenon. A robust research effort should work to identify a krypton-selective MOF designed to operate at temperatures of approximately 0°C or higher, which could be preferred over cryogenic krypton/xenon capture for used fuel reprocessing off-gas streams. In the case of the CaSDB-MOF (the most well-understood xenon sorbent to date), two issues are judged of high importance. First, xenon breakthrough capacity for the CaSDB-MOF in prototypical conditions should be determined. Preliminary research indicates that breakthrough may be near immediate, presenting a substantial obstacle in separative system design. Second, development of desorption methodology should be performed to determine regeneration time, energy requirements, and the product stream composition. Silver-based sorbents (AgZ and AgAero) for use in iodine capture from the dissolver off-gas were evaluated against the established criteria. These sorbents are significantly better understood for this application as a result of research efforts over the past decade. The potential implementation of AgAero at a large scale is hindered by its physical degradation by components of the dissolver off-gas stream. Less is known about the adsorption of iodine by these sorbents from other off-gas streams in the plant. Initial experimental efforts have been closely coordinated in an effort to understand organic iodine (such as would be found in the vessel off-gas) adsorption by AgZ and AgAero. Future work should expand this experimental program, and analysis of other reprocessing facility off-gas streams such as the vitrification off-gas stream should be conducted to better understand other potential applications for iodine sorbents. A review of iodine waste form development shows that this area is diverse and that multiple promising waste forms have been identified for the immobilization of radioactive iodine. Efforts related to the direct conversion of iodine sorbents (including AgZ and AgAero) should be continued because of the advantages of direct conversion in a waste management strategy and other sorbents should continue to be advanced as merited.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A first roadmap for kryptology

Studies of the complex variations of the isotopic composition of xenon in the solar system have been christened 'xenology'. In the title of the present investigation, the word 'kryptology' is employed to indicate the primary objective of the reported studies. This objective is related to the prediction of the isotopic composition of krypton which comes from a number of specific locations of a supernova in association with the isotopic compositions of xenon from these locations. Krypton is a logical candidate for testing the stellar theory on geochemical grounds, taking into account also the point of view of nucleosynthesis, because the isotopes of xenon and krypton are formed by the same thermonuclear processes in stars. The data and arguments presented in the investigation show that the treatment by Heymann and Dziczkaniec (1979), although not wrong, is too simplistic, because it has ignored the possibility of holdup and arrest in Xe network.

Heymann, D.↗

Improved Multiple-Species Cyclotron Ion Source

Use of pure isotope 86Kr instead of natural krypton in multiple-species ion source enables source to produce krypton ions separated from argon ions by tuning cylcotron with which source used. Addition of capability to produce and separate krypton ions at kinetic energies of 150 to 400 MeV necessary for simulation of worst-case ions occurring in outer space.

Soli, George A.↗

The determination of accurate dipole polarizabilities alpha and gamma for the noble gases

The static dipole polarizabilities alpha and gamma for the noble gases helium through xenon were determined using large flexible one-particle basis sets in conjunction with high-level treatments of electron correlation. The electron correlation methods include single and double excitation coupled-cluster theory (CCSD), an extension of CCSD that includes a perturbational estimate of connected triple excitations, CCSD(T), and second order perturbation theory (MP2). The computed alpha and gamma values are estimated to be accurate to within a few percent. Agreement with experimental data for the static hyperpolarizability gamma is good for neon and xenon, but for argon and krypton the differences are larger than the combined theoretical and experimental uncertainties. Based on our calculations, we suggest that the experimental value of gamma for argon is too low; adjusting this value would bring the experimental value of gamma for krypton into better agreement with our computed result. The MP2 values for the polarizabilities of neon, argon, krypton and zenon are in reasonabe agreement with the CCSD and CCSD(T) values, suggesting that this less expensive method may be useful in studies of polarizabilities for larger systems.

Rice, Julia E.↗

Radiation Effects on DC-DC Converters

In this work, several DC-DC converters were designed and built. The converters are Buck Buck-Boost, Cuk, Flyback, and full-bridge zero-voltage switched. The total ionizing dose radiation and single event effects on the converters were investigated. The experimental results for the TID effects tests show that the voltages of the Buck Buck-Boost, Cuk, and Flyback converters increase as total dose increased when using power MOSFET IRF250 as a switching transistor. The change in output voltage with total dose is highest for the Buck converter and the lowest for Flyback converter. The trend of increase in output voltages with total dose in the present work agrees with those of the literature. The trends of the experimental results also agree with those obtained from PSPICE simulation. For the full-bridge zero-voltage switch converter, it was observed that the dc-dc converter with IRF250 power MOSFET did not show a significant change of output voltage with total dose. In addition, for the dc-dc converter with FSF254R4 radiation-hardened power MOSFET, the output voltage did not change significantly with total dose. The experimental results were confirmed by PSPICE simulation that showed that FB-ZVS converter with IRF250 power MOSFET's was not affected with the increase in total ionizing dose. Single Event Effects (SEE) radiation tests were performed on FB-ZVS converters. It was observed that the FB-ZVS converter with the IRF250 power MOSFET, when the device was irradiated with Krypton ion with ion-energy of 150 MeV and LET of 41.3 MeV-square cm/mg, the output voltage increased with the increase in fluence. However, for Krypton with ion-energy of 600 MeV and LET of 33.65 MeV-square cm/mg, and two out of four transistors of the converter were permanently damaged. The dc-dc converter with FSF254R4 radiation hardened power MOSFET's did not show significant change at the output voltage with fluence while being irradiated by Krypton with ion energy of 1.20 GeV and LET of 25.97 MeV-square cm/mg. This might be due to fact that the device is radiation hardened.

Zhang, De-Xin↗