Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kWh”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Modeling the Effect of Material Properties on Liquid-Alkaline Water Electrolysis

Liquid-alkaline water electrolyzers (LAWEs) use electricity to drive the conversion of water to H 2 and O 2 gas. These devices benefit from the use of low-cost nickel electrodes and metal-oxide separators, but suffer from lower current densities and higher cell voltages than proton-exchange-membrane water electrolyzers. Identifying the inefficiencies that result in this poor performance is key to mitigating losses and optimizing LAWEs. Here, we report an experimentally-validated 1-D continuum model of a LAWE that elucidates the gradients within the cell, simulates H 2 crossover, and projects the energy improvements made possible by modulating the properties of the electrodes and separator. The model captures the Nernstian polarization losses and the distribution of gas- and liquid-phases within the electrodes, enabling quantification of energy losses associated with kinetic, ohmic, and bubble-induced (mass-transport) resistances. Simulations demonstrate that LAWE can achieve energy intensities of 50 kWh kg −1 of H 2 at 1 A cm −2 using improved electrode and separator properties.

08 HYDROGEN↗

SIDSIM (Sub-Interval Distribution Simulation) [SWR-17-22]

This software is based on a distribution function to represent a variable value over a time-step in time-series simulation of a photovoltaic or wind system, with application to other types of variable-output generator such as wave power. This invention offers important benefits over prior art. Prior art assumes a constant value for each parameter over the duration of each time-step. The form of the distribution function is determined by a maximum value (kW), a minimum value (kW) and energy (kWh) for each time step, and integration of this distribution function provides information such as energy in excess of some threshold (inverter capacity, interconnect capacity, on-site load, etc) and energy delivered under any such specified threshold. Results such as maximum power that can be exported from a distributed generation system are determined and very important for energy systems integration.

Walker, Andy↗

Resiliency in numerical algorithm design for extreme scale simulations

Here this work is based on the seminar titled ‘Resiliency in Numerical Algorithm Design for Extreme Scale Simulations’ held March 1–6, 2020, at Schloss Dagstuhl, that was attended by all the authors. Advanced supercomputing is characterized by very high computation speeds at the cost of involving an enormous amount of resources and costs. A typical large-scale computation running for 48 h on a system consuming 20 MW, as predicted for exascale systems, would consume a million kWh, corresponding to about 100k Euro in energy cost for executing 10 23 floating-point operations. It is clearly unacceptable to lose the whole computation if any of the several million parallel processes fails during the execution. Moreover, if a single operation suffers from a bit-flip error, should the whole computation be declared invalid? What about the notion of reproducibility itself: should this core paradigm of science be revised and refined for results that are obtained by large-scale simulation? Naive versions of conventional resilience techniques will not scale to the exascale regime: with a main memory footprint of tens of Petabytes, synchronously writing checkpoint data all the way to background storage at frequent intervals will create intolerable overheads in runtime and energy consumption. Forecasts show that the mean time between failures could be lower than the time to recover from such a checkpoint, so that large calculations at scale might not make any progress if robust alternatives are not investigated. More advanced resilience techniques must be devised. The key may lie in exploiting both advanced system features as well as specific application knowledge. Research will face two essential questions: (1) what are the reliability requirements for a particular computation and (2) how do we best design the algorithms and software to meet these requirements? While the analysis of use cases can help understand the particular reliability requirements, the construction of remedies is currently wide open. One avenue would be to refine and improve on system- or application-level checkpointing and rollback strategies in the case an error is detected. Developers might use fault notification interfaces and flexible runtime systems to respond to node failures in an application-dependent fashion. Novel numerical algorithms or more stochastic computational approaches may be required to meet accuracy requirements in the face of undetectable soft errors. These ideas constituted an essential topic of the seminar. The goal of this Dagstuhl Seminar was to bring together a diverse group of scientists with expertise in exascale computing to discuss novel ways to make applications resilient against detected and undetected faults. In particular, participants explored the role that algorithms and applications play in the holistic approach needed to tackle this challenge. This article gathers a broad range of perspectives on the role of algorithms, applications and systems in achieving resilience for extreme scale simulations. The ultimate goal is to spark novel ideas and encourage the development of concrete solutions for achieving such resilience holistically.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy Productivity of the High Velocity Algae Raceway Integrated Design (ARID-HV)

The ARID raceway is an effective method to maintain temperature in the optimal growing range. However, the energy input is excessive. Thus, the ARID-HV raceway was developed in order to reduce energy input requirements. This was accomplished by improving pumping efficiency and using a serpentine flow pattern in which the water flows through channels instead of over barriers. A prototype ARID-HV raceway was installed in Tucson, Arizona in order to evaluate the flow and energy requirements of the raceway. Preliminary results show continued high energy usage, but this paper explores the possible energy reductions with the new ARID-HV design with efficient propeller pumps and properly engineered channel lengths. Channel lengths are evaluated with Manning’s equation in order to determine the maximum channel length that could be implemented with the current pumping configuration

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HydraGNN_Predictive_GFM_2024 - Ensemble of predictive graph foundation models for ground state atomistic materials modeling

We provide the ensemble of fifteen pre-trained graph foundation models (GFMs) for atomistic materials modeling applications. Each one of the fifteen GFMs has been trained on five open-source datasets that (once aggregated) amount to over 154 million atomistic structures, which cover over two-thirds of the natural elements of the periodic table and that comprises a broad set of organic and inorganic compounds. This vast set of atomistic structures comprises ground state configurations that are dynamically stable (i.e., equilibrated structures with atomic forces approximately close to zero values) as well as dynamically unstable structures (i.e., non-equilibrium structures with non-negligible non-zero values of atomic forces). The ensemble of datasets aggregated does NOT include excited states. The datasets have been curated to remove atomistic structures with spectral norm of the force tensor above 100 eV/angstrom. Moreover, a linear term of the energy was computed for each dataset using a linear regression model that uses the chemical concentration of each natural element as regressor. The linear term predicted by the linear regression model has been subtracted from each original energy value to perform a re-alignment of the energy values across different electronic structures approximation theories performed to generate the diverse multi-source, multi-fidelity datasets. The folder "ADIOS_files" contains the set of pre-processed datasets in Adaptable I/O System (ADIOS) format (https://www.exascaleproject.org/research-project/adios/) that have been used for the development and training of GFMs in this work. The "ADIOS_files" directory contains 6 sub-directories named as follows: - ANI1x-v3.bp - MPTrj-v3.bp - OC2020-20M-v3.bp - OC2020-v3.bp - OC2022-v3.bp - qm7x-v3.bp Each sub-directory contains the pre-processed datasets converted in Adaptable I/O System (ADIOS) format (https://www.exascaleproject.org/research-project/adios/) that have been used to the development, training, and performance testing of the ensemble go predictive graph foundation models. Each GFM was developed using HydraGNN (https://github.com/ORNL/HydraGNN) as underlying graph neural network (GNN) architecture. The multi-task learning (MTL) capability of HydraGNN was used to simultaneously train the GFMs on labeled values for direct predictions of energy (a total system property of an atomistic structure that measures the chemical stability) and atomic forces (an atomic level property of an atomistic structure that measures the dynamical stability). The hyper parameters of the GFM have been tuned using scalable hyperparameter optimization (HPO) algorithms implemented in the software DeepHyper (https://github.com/deephyper/deephyper). The pre-training of each HPO trial was performed using distributed data parallelism (DDP) to scale the training across 128 compute nodes of the exascale OLCF supercomputer Frontier. Each HPO trial was trained only for 10 epochs and an early stopping was performed to avoid wasting significant computational resources on GNN architectures that were clearly underperforming. For each HPO trial, the 'omnistat' tool developed by (AMD Research - Advanced Micro Device) was used to measure the total energy consumption in kWh. The ensemble of GFMs was obtained by selecting the fifteen best performing HPO trials. Four models have been selected for their clear advantage in accuracy, and these are the GFMs with IDs 229, 156, 147, 260. Additional eleven models have been selected based on judicious balance between accuracy and energy consumption needed for training, and these are the GFMs with IDs 165, 78, 137, 1, 175, 171, 181, 67, 179, 167, 351. Each selected GFM of the ensemble was continued to cumulate a total of at most 30 epochs. In some cases, the total number of epochs actually performed was les than 30 due to two combined factors: (1) the size of the GFM (i.e., the number of model parameters to train) and (2) the total wall-clock time for which the computational resources could be allocated on OLCF-Frontier. The "Ensemble_of_models" directory contains 15 sub-directories named as follows: - gfm_0.229 - gfm_0.156 - gfm_0.147 - gfm_0.260 - gfm_0.165 - gfm_0.78 - gfm_0.137 - gfm_0.1 - gfm_0.175 - gfm_0.171 - gfm_0.181 - gfm_0.67 - gfm_0.179 - gfm_0.167 - gfm_0.351 Each one of these sub-directories refers to one of the fifteen HPO trials that have been selected to continue the pre-training with at most 30 epochs. With each sub-directory associated with a specific HPO trial, the following files can be found: - config.json: file for argument parsing to develop and train an HydraGNN architecture - gfm_0.ID_epoch_N.pk: file with model parameters for HPO ID trial after N epochs of training The ensemble of fifteen GFM architectures was used for (1) ensemble averaging to stabilize the predictions of energy and atomic forces after pre-training for post-processing analysis and (2) ensemble uncertainty quantification (UQ). The code used to develop, pre-train, and load the pre-trained models for post-processing analysis is available on the ORNL-GitHub at the following link: https://github.com/ORNL/HydraGNN/tree/Predictive_GFM_2024

36 MATERIALS SCIENCE↗

EV Shuttle Bus Pilot

The EV Shuttle Bus Pilot dataset contains data and analysis from Hocking-Athens-Perry Community Action's demonstration of an electric bus on routes of their rural Athens Public Transit system. The vehicle used in the demonstration was a Ford E-450 cutaway equipped with an electric drivetrain, a 127-kWh battery system by Motiv Power Systems, and a cabin upfit by Turtle Top. Data gathered include route assignments, running time and distance, fuel economy, and charge cycles. A comparison of the vehicle's observed duty cycle with duty cycle modeling from other rural transit fleets in the National Transit Database is included to help better understand the rural adoption potential for this fleet technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FVB Energy Inc. Technical Assistance Project

The request made by FVB asked for advice and analysis regarding the value of recapturing the braking energy of trains operating on electric light rail transit systems. A specific request was to evaluate the concept of generating hydrogen by electrolysis. The hydrogen would, in turn, power fuel cells that could supply electric energy back into the system for train propulsion or, possibly, also to the grid. To allow quantitative assessment of the potential resource, analysis focused on operations of the SoundTransit light rail system in Seattle, Washington. An initial finding was that the full cycle efficiency of producing hydrogen as the medium for capturing and reusing train braking energy was quite low (< 20%) and, therefore, not likely to be economically attractive. As flywheel energy storage is commercially available, the balance of the analysis focused the feasibility of using this alternative on the SoundTransit system. It was found that an investment in a flywheel with a 25-kWh capacity of the type manufactured by Beacon Power Corporation (BPC) would show a positive 20-year net present value (NPV) based on the current frequency of train service. The economic attractiveness of this option would increase initially if green energy subsidies or rebates were applicable and, in the future, as the planned frequency of train service grows.

08 HYDROGEN↗

Demonstration Assessment of Light-Emitting Diode (LED) Parking Lot Lighting in Leavenworth, KS

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a commercial parking lot lighting application, under the U.S. Department of Energy (DOE) Solid-State Lighting Technology GATEWAY Demonstration Program. The parking lot is for customers and employees of a Walmart Supercenter in Leavenworth, Kansas and this installation represents the first use of the LED Parking Lot Performance Specification developed by the DOE’s Commercial Building Energy Alliance. The application is a parking lot covering more than a half million square feet, lighted primarily by light-emitting diodes (LEDs). Metal halide wall packs were installed along the building facade. This site is new construction, so the installed baseline(s) were hypothetical designs. It was acknowledged early on that deviating from Walmart’s typical design would reduce the illuminance on the site. Walmart primarily uses 1000W pulse-start metal halide (PMH) lamps. In order to provide a comparison between both typical design and a design using conventional luminaires providing a lower illuminance, a 400W PMH design was also considered. As mentioned already, the illuminance would be reduced by shifting from the PMH system to the LED system. The Illuminating Engineering Society of North America (IES) provides recommended minimum illuminance values for parking lots. All designs exceeded the recommended illuminance values in IES RP-20, some by a wider margin than others. Energy savings from installing the LED system compared to the different PMH systems varied. Compared to the 1000W PMH system, the LED system would save 63 percent of the energy. However, this corresponds to a 68 percent reduction in illuminance as well. In comparison to the 400W PMH system, the LED system would save 44 percent of the energy and provide similar minimum illuminance values at the time of relamping. The LED system cost more than either of the PMH systems when comparing initial costs. However, when the life-cycle costs from energy and maintenance were factored into the scenario, the LED system had lower costs at the end of a 10-year analysis period. The LED system had a 6.1 year payback compared to the 1000W PMH system and a 7.5 year payback versus the 400W PMH system. The costs reflect high initial cost for the LED luminaire, plus more luminaires and (subsequently) more poles for the LED system. The other major issue affecting cost effectiveness was that Leavenworth, Kansas has very low electricity costs. The melded rate for this site was $0.056 per kWh for electricity. However, if the national electricity rate of $0.1022/kWh was used the payback would change to between four and five years for the LED system. This demonstration met the GATEWAY requirements of saving energy, matching or improving illumination, and being cost effective. The project also demonstrated that the Commercial Building Energy Alliance (CBEA) specification works in practice. Walmart appreciated having an entire site lighted by LEDs to gain more experience with the technology. Walmart is reviewing the results of the demonstration as they consider their entire real estate portfolio.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RECOVERY ACT: DYNAMIC ENERGY CONSUMPTION MANAGEMENT OF ROUTING TELECOM AND DATA CENTERS THROUGH REAL-TIME OPTIMAL CONTROL (RTOC): Final Scientific/Technical Report

This final scientific report documents the Industrial Technology Program (ITP) Stage 2 Concept Development effort on Data Center Energy Reduction and Management Through Real-Time Optimal Control (RTOC). Society is becoming increasingly dependent on information technology systems, driving exponential growth in demand for data center processing and an insatiable appetite for energy. David Raths noted, 'A 50,000-square-foot data center uses approximately 4 megawatts of power, or the equivalent of 57 barrels of oil a day1.' The problem has become so severe that in some cases, users are giving up raw performance for a better balance between performance and energy efficiency. Historically, power systems for data centers were crudely sized to meet maximum demand. Since many servers operate at 60%-90% of maximum power while only utilizing an average of 5% to 15% of their capability, there are huge inefficiencies in the consumption and delivery of power in these data centers. The goal of the 'Recovery Act: Decreasing Data Center Energy Use through Network and Infrastructure Control' is to develop a state of the art approach for autonomously and intelligently reducing and managing data center power through real-time optimal control. Advances in microelectronics and software are enabling the opportunity to realize significant data center power savings through the implementation of autonomous power management control algorithms. The first step to realizing these savings was addressed in this study through the successful creation of a flexible and scalable mathematical model (equation) for data center behavior and the formulation of an acceptable low technical risk market introduction strategy leveraging commercial hardware and software familiar to the data center market. Follow-on Stage 3 Concept Development efforts include predictive modeling and simulation of algorithm performance, prototype demonstrations with representative data center equipment to verify requisite performance and continued commercial partnering agreement formation to ensure uninterrupted development, and deployment of the real-time optimal control algorithm. As a software implementable technique for reducing power consumption, the RTOC has two very desirable traits supporting rapid prototyping and ultimately widespread dissemination. First, very little capital is required for implementation. No major infrastructure modifications are required and there is no need to purchase expensive capital equipment. Second, the RTOC can be rolled out incrementally. Therefore, the effectiveness can be proven without a large scale initial roll out. Through the use of the Impact Projections Model provided by the DOE, monetary savings in excess of $100M in 2020 and billions by 2040 are predicted. In terms of energy savings, the model predicts a primary energy displacement of 260 trillion BTUs (33 trillion kWh), or a 50% reduction in server power consumption. The model also predicts a corresponding reduction of pollutants such as SO2 and NOx in excess of 100,000 metric tonnes assuming the RTOC is fully deployed. While additional development and prototyping is required to validate these predictions, the relative low cost and ease of implementation compared to large capital projects makes it an ideal candidate for further investigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recovery Act: Federspiel Controls (now Vigilent) and State of California Department of General Services Data Center Energy Efficient Cooling Control Demonstration. Final technical project report

Eight State of California data centers were equipped with an intelligent energy management system to evaluate the effectiveness, energy savings, dollar savings and benefits that arise when powerful artificial intelligence-based technology measures, monitors and actively controls cooling operations. Control software, wireless sensors and mesh networks were used at all sites. Most sites used variable frequency drives as well. The system dynamically adjusts temperature and airflow on the fly by analyzing real-time demands, thermal behavior and historical data collected on site. Taking into account the chaotic interrelationships of hundreds to thousands of variables in a data center, the system optimizes the temperature distribution across a facility while also intelligently balancing loads, outputs, and airflow. The overall project will provide a reduction in energy consumption of more than 2.3 million kWh each year, which translates to $240,000 saved and a reduction of 1.58 million pounds of carbon emissions. Across all sites, the cooling energy consumption was reduced by 41%. The average reduction in energy savings across all the sites that use VFDs is higher at 58%. Before this case study, all eight data centers ran the cooling fans at 100% capacity all of the time. Because of the new technology, cooling fans run at the optimum fan speed maintaining stable air equilibrium while also expending the least amount of electricity. With lower fan speeds, the life of the capital investment made on cooling equipment improves, and the cooling capacity of the data center increases. This case study depicts a rare technological feat: The same process and technology worked cost effectively in eight very different environments. The results show that savings were achieved in centers with diverse specifications for the sizes, ages and types of cooling equipment. The percentage of cooling energy reduction ranged from 19% to 78% while keeping temperatures substantially within the limits recommended by the American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) for data center facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Cool Roofs to Reduce Energy Use, Greenhouse Gas Emissions, and Urban Heat-island Effects: Findings from an India Experiment

Cool roofs, cool pavements, and urban vegetation reduce energy use in buildings, lower local air pollutant concentrations, and decrease greenhouse gas emissions from urban areas. This report summarizes the results of a detailed monitoring project in India and related simulations of meteorology and air quality in three developing countries. The field results quantified direct energy savings from installation of cool roofs on individual commercial buildings. The measured annual energy savings potential from roof-whitening of previously black roofs ranged from 20-22 kWh/m2 of roof area, corresponding to an air-conditioning energy use reduction of 14-26% in commercial buildings. The study estimated that typical annual savings of 13-14 kWh/m2 of roof area could be achieved by applying white coating to uncoated concrete roofs on commercial buildings in the Metropolitan Hyderabad region, corresponding to cooling energy savings of 10-19%. With the assumption of an annual increase of 100,000 square meters of new roof construction for the next 10 years in the Metropolitan Hyderabad region, the annual cooling energy savings due to whitening concrete roof would be 13-14 GWh of electricity in year ten alone, with cumulative 10-year cooling energy savings of 73-79 GWh for the region. The estimated savings for the entire country would be at least 10 times the savings in Hyderabad, i.e., more than 730-790 GWh. We estimated that annual direct CO2 reduction associated with reduced energy use would be 11-12 kg CO2/m2 of flat concrete roof area whitened, and the cumulative 10-year CO2 reduction would be approximately 0.60-0.65 million tons in India. With the price of electricity estimated at seven Rupees per kWh, the annual electricity savings on air-conditioning would be approximately 93-101 Rupees per m2 of roof. This would translate into annual national savings of approximately one billion Rupees in year ten, and cumulative 10-year savings of over five billion Rupees for cooling energy in India. Meteorological simulations in this study indicated that a reduction of 2C in air temperature in the Hyderabad area would be likely if a combination of increased surface albedo and vegetative cover are used as urban heat-island control strategies. In addition, air-temperature reductions on the order of 2.5-3.5C could be achieved if moderate and aggressive heat-island mitigation measures are adopted, respectively. A large-scale deployment of mitigation measures can bring additional indirect benefit to the urban area. For example, cooling outside air can improve the efficiency of cooling systems, reduce smog and greenhouse gas (GHG) emissions, and indirectly reduce pollution from power plants - all improving environmental health quality. This study has demonstrated the effectiveness of cool-roof technology as one of the urban heat-island control strategies for the Indian industrial and scientific communities and has provided an estimate of the national energy savings potential of cool roofs in India. These outcomes can be used for developing cool-roof building standards and related policies in India. Additional field studies, built upon the successes and lessons learned from this project, may be helpful to further confirm the scale of potential energy savings from the application of cooler roofs in various regions of India. In the future, a more rigorous meteorological simulation using urbanized (meso-urban) meteorological models should be conducted, which may produce a more accurate estimate of the air-temperature reductions for the entire urban area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interval Data Analysis with the Energy Charting and Metrics Tool (ECAM)

Analyzing whole building interval data is an inexpensive but effective way to identify and improve building operations, and ultimately save money. Utilizing the Energy Charting and Metrics Tool (ECAM) add-in for Microsoft Excel, building operators and managers can begin implementing changes to their Building Automation System (BAS) after trending the interval data. The two data components needed for full analyses are whole building electricity consumption (kW or kWh) and outdoor air temperature (OAT). Using these two pieces of information, a series of plots and charts and be created in ECAM to monitor the buildings performance over time, gain knowledge of how the building is operating, and make adjustments to the BAS to improve efficiency and start saving money.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bexar County Parking Garage Photovoltaic Panels

The main objective of the Bexar County Parking Garage Photovoltaic (PV) Panel project is to install a PV System that will promote the use of renewable energy. This project will also help sustain Bexar County ongoing greenhouse gas emissions reduction and energy efficiency goals. The scope of this project includes the installation of a 100-kW system on the top level of a new 236,285 square feet parking garage. The PV system consists of 420 solar panels that covers 7,200 square feet and is tied into the electric-grid. It provides electricity to the office area located within the garage. The estimated annual electricity production of the PV system is 147,000 kWh per year.

14 SOLAR ENERGY↗

Development of an Anode Stabilization Layer for High Energy Li-S Cells for Electric Vehicles

For lithium-Sulfur (Li-S) batteries to be practical, economic and safe for powering electric vehicles more than 300 miles between charges the energy and cycle life must be improved. Li- S’s theoretical specific energy and energy density are (2,550 Wh/kg, 2,860 Wh/l), compared to (~600 Wh/kg, 1,800 Wh/l) for Li-ion. At less than 25% of theoretical specific energy (~560 Wh/kg at the cell level), Li-S batteries could power a 1500 kg, 5 passenger vehicle, more than 300 miles between charges with a battery pack weighing less than 300 kg. For commercial viability these cells must be safe, low cost and exhibit more than 1,000 full depth of discharge cycles. By implementing unique new physical barrier technologies this work targets (500 Wh/kg, 500 cycles) at the cell level by late 2013. After this program, (600 Wh/kg, 1,000 cycles) cells are targeted in >40 kWh battery packs by 2018 at < $200/kWh. The present state-of-the-art Li-S cells developed at Sion Power, in current commercial format delivers (2.8 Ah, 5.8 Wh, 350 Wh/kg) and are limited to ~50 cycles. These cells deliver only 14% of theoretical specific energy. By retooling and optimizing cell design and packaging to rebalance materials, this chemistry can reach (350 Wh/kg, ~100 cycles) in commercial cells. Much more than 100 cycles, at >350 Wh/kg, is unlikely for the present chemistry-only Li-S cell paradigm. Cycle life is limited almost exclusively by reactions between the Li-metal anode and the solvents necessary to promote cathode function. To release the transformational energy of Li-S the anode must be decoupled from the cathode chemistry. Prospects to achieve this decoupling through chemistry alone are challenging, therefore this program is to accelerate efforts to decouple anode and cathode chemistries by separating the electrodes with ion selective, thin film multi-layer, physical barrier membranes stabilized by externally applied pressure. This report will focus on efforts of Battelle to develop an anode stabilization layer and method to measure the ionic conductivity of this thin vacuum deposited polymeric layer.

Gross, M. E.↗

Elk Valley Rancheria Energy Efficiency and Alternatives Analysis

The Elk Valley Rancheria, California ('Tribe') is a federally recognized Indian tribe located in Del Norte County, California, in the northwestern corner of California. The Tribe, its members and Tribal enterprises are challenged by increasing energy costs and undeveloped local energy resources. The Tribe currently lacks an energy program. The Tribal government lacked sufficient information to make informed decisions about potential renewable energy resources, energy alternatives and other energy management issues. To meet this challenge efficiently, the Tribe contracted with Frank Zaino and Associates, Inc. to help become more energy self-sufficient, by reducing their energy costs and promoting energy alternatives that stimulate economic development. Frank Zaino & Associates, Inc. provided a high level economic screening analysis based on anticipated electric and natural gas rates. This was in an effort to determine which alternative energy system will performed at a higher level so the Tribe could reduce their energy model by 30% from alternative fuel sources. The feasibility study will identify suitable energy alternatives and conservation methods that will benefit the Tribe and tribal community through important reductions in cost. The lessons learned from these conservation efforts will yield knowledge that will serve a wider goal of executing energy efficiency measures and practices in Tribal residences and business facilities. Pacific Power is the provider of electrical power to the four properties under review at $ 0.08 per Kilowatt-hour (KWH). This is a very low energy cost compared to alternative energy sources. The Tribe used baseline audits to assess current and historic energy usage at four Rancheria owned facilities. Past electric and gas billing statements were retained for review for the four buildings that will be audited. A comparative assessment of the various energy usages will determine the demand, forecast future need and identify the differences in energy costs, narrowing the focus of the work and defining its scope. The Tribe's peak demand periods will help determine the scope of need for alternative energy sources. The Tribe's Energy Efficiency and Alternatives Analysis report included several system investigations which include fuel cells, wind turbines, solar panels, hydro electric, ground source heat pumps, bio mass, cogeneration & energy conservation and implementation for the existing properties. The energy analysis included site visits to collect and analyze historical energy usage and cost. The analysis also included the study of the building systems for the Elk Valley Casino, Elk Valley Rancheria administration complex, United Indian Health Service/Small Community Center complex and the Tribal Gaming Commission Offices. The analysis involved identifying modifications, performing an engineering economic analysis, preparation of a rank ordered list of modifications and preparation of a report to provide recommendations and actions for the Tribe to implement.

03 NATURAL GAS↗

Replacement of Lighting Fixtures with LED Energy Efficient Lights at the Parking Facility, Milwaukee, Wisconsin

The Forest County Potawatomi Community (FCPC or Tribe) owns a six-story parking facility adjacent to its Potawatomi Bingo Casino (the Casino) in Milwaukee, Wisconsin, as well as a valet parking facility under the Casino (collectively, the Parking Facility). The Parking Facility contained 205-watt metal halide-type lights that, for security reasons, operated 24 hours per day, 7 days per week. Starting on August 30, 2010, the Tribe replaced these fixtures with 1,760 state-of-the-art, energy efficient 55-Watt LED lights. This project resulted in an immediate average reduction in monthly peak demand of 238 kW over the fourth quarter of 2010. The average reduction in monthly peak demand from October 1 through December 31, 2010 translates into a forecast annual electrical energy reduction of approximately 1,995,000 kWh or 47.3% of the pre-project demand. This project was technically effective, economically feasible, and beneficial to the public not only in terms of long term energy efficiency and associated emissions reductions, but also in the short-term jobs provided for the S.E. Wisconsin region. The project was implemented, from approval by U.S. Department of Energy (DOE) to completion, in less than 6 months. The project utilized off-the-shelf proven technologies that were fabricated locally and installed by local trade contractors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Texas Hydrogen Highway Fuel Cell Hybrid Bus and Fueling Infrastructure Technology Showcase (Final Scientific/Technical Report)

The Texas Hydrogen Highway project has showcased a hydrogen fuel cell transit bus and hydrogen fueling infrastructure that was designed and built through previous support from various public and private sector entities. The aim of this project has been to increase awareness among transit agencies and other public entities on these transportation technologies, and to place such technologies into commercial applications, such as a public transit agency. The initial project concept developed in 2004 was to show that a skid-mounted, fully-integrated, factory-built and tested hydrogen fueling station could be used to simplify the design, and lower the cost of fueling infrastructure for fuel cell vehicles. The approach was to design, engineer, build, and test the integrated fueling station at the factory then install it at a site that offered educational and technical resources and provide an opportunity to showcase both the fueling station and advanced hydrogen vehicles. The two primary technology components include: Hydrogen Fueling Station: The hydrogen fueling infrastructure was designed and built by Gas Technology Institute primarily through a funding grant from the Texas Commission on Environmental Quality. It includes hydrogen production, clean-up, compression, storage, and dispensing. The station consists of a steam methane reformer, gas clean-up system, gas compressor and 48 kilograms of hydrogen storage capacity for dispensing at 5000 psig. The station is skid-mounted for easy installation and can be relocated if needed. It includes a dispenser that is designed to provide temperature compensated fills using a control algorithm. The total station daily capacity is approximately 50 kilograms. Fuel Cell Bus: The transit passenger bus built by Ebus, a company located in Downey, CA, was commissioned and acquired by GTI prior to this project. It is a fuel cell plug-in hybrid electric vehicle which is ADA compliant, has air conditioning sufficient for Texas operations, and regenerative braking for battery charging. It uses a 19.3 kW Ballard PEM fuel cell, will store 12.6 kg of hydrogen at 350 Bar, and includes a 60 kWh battery storage system. The objectives of the project included the following: (a) To advance commercialization of hydrogen-powered transit buses and supporting infrastructure; (b) To provide public outreach and education by showcasing the operation of a 22-foot fuel cell hybrid shuttle bus and Texas first hydrogen fueling infrastructure; and (c) To showcase operation of zero-emissions vehicle for potential transit applications. As mentioned above, the project successfully demonstrated an early vehicle technology, the Ebus plug-in hybrid fuel cell bus, and that success has led to the acquisition of a more advanced vehicle that can take advantage of the same fueling infrastructure. Needed hydrogen station improvements have been identified that will enhance the capabilities of the fueling infrastructure to serve the new bus and to meet the transit agency needs. Over the course of this project, public officials, local government staff, and transit operators were engaged in outreach and education activities that acquainted them with the real world operation of a fuel cell bus and fueling infrastructure. Transit staff members in the Dallas/Ft. Worth region were invited to a workshop in Arlington, Texas at the North Central Texas Council of Governments to participate in a workshop on hydrogen and fuel cells, and to see the fuel cell bus in operation. The bus was trucked to the meeting for this purpose so that participants could see and ride the bus. Austin area transit staff members visited the fueling site in Austin to be briefed on the bus and to participate in a fueling demonstration. This led to further meetings to determine how a fuel cell bus and fueling station could be deployed at Capital Metro Transit. Target urban regions that expressed additional interest during the project in response to the outreach meetings and showcase events include San Antonio and Austin, Texas. In summary, the project objectives were achieved in the following ways: Through presentations and papers provided to a variety of audiences in multiple venues, the project team fulfilled its goal of providing education and outreach on hydrogen technology to statewide audiences. The project team generated interest that exists well beyond the completion of the project, and indeed, helped to generate financial support for a subsequent hydrogen vehicle project in Austin. The University of Texas, Center for ElectroMechanics operated the fuel cell-electric Ebus vehicle for over 13,000 miles in Austin, Texas in a variety of routes and loading configurations. The project took advantage of prior efforts that created a hydrogen fueling station and fuel cell electric-hybrid bus and continued to verify their technical foundation, while informing and educating potential future users of how these technologies work.

03 NATURAL GAS↗

Updated Greenhouse Gas and Criteria Air Pollutant Emission Factors and Their Probability Distribution Functions for Electricity Generating Units

Greenhouse gas (CO 2 , CH 4 and N 2 O, hereinafter GHG) and criteria air pollutant (CO, NO x , VOC, PM 10 , PM 2.5 and SO x , hereinafter CAP) emission factors for various types of power plants burning various fuels with different technologies are important upstream parameters for estimating life-cycle emissions associated with alternative vehicle/fuel systems in the transportation sector, especially electric vehicles. The emission factors are typically expressed in grams of GHG or CAP per kWh of electricity generated by a specific power generation technology. This document describes our approach for updating and expanding GHG and CAP emission factors in the GREET (Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation) model developed at Argonne National Laboratory (see Wang 1999 and the GREET website at http://greet.es.anl.gov/main) for various power generation technologies. These GHG and CAP emissions are used to estimate the impact of electricity use by stationary and transportation applications on their fuel-cycle emissions. The electricity generation mixes and the fuel shares attributable to various combustion technologies at the national, regional and state levels are also updated in this document. The energy conversion efficiencies of electric generating units (EGUs) by fuel type and combustion technology are calculated on the basis of the lower heating values of each fuel, to be consistent with the basis used in GREET for transportation fuels. On the basis of the updated GHG and CAP emission factors and energy efficiencies of EGUs, the probability distribution functions (PDFs), which are functions that describe the relative likelihood for the emission factors and energy efficiencies as random variables to take on a given value by the integral of their own probability distributions, are updated using best-fit statistical curves to characterize the uncertainties associated with GHG and CAP emissions in life-cycle modeling with GREET.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗