Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometry metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Optical system design for a Lunar Optical Interferometer

The moon offers particular advantages for interferometry, including a vacuum environment, a large stable base on which to assemble multi-kilometer baselines, and a cold nighttime temperature to allow for passive cooling of optics for high IR sensitivity. A baseline design for a Lunar Optical Interferometer (LOI) which exploits these features is presented. The instrument operates in the visible to mid-IL region, and is designed for both astrometry and synthesis imaging. The design uses a Y-shaped array of 12 siderostats, with maximum arm lengths of about 1 km. The inner siderostats are monitored in three dimensions from a central laser metrology structure to allow for high precision astrometry. The outer siderostats, used primarily for synthesis imaging, exploit the availability of bright reference stars in order to determine the instrument geometry. The path delay function is partitioned into coarse and fine components, the former accomplished with switched banks of range mirrors monitored with an absolute laser metrology system, and the latter with a short cat's eye delay line. The back end of the instrument is modular, allowing for beam combiners for astrometry, visible and IR synthesis imaging, and direct planet detection. With 1 m apertures, the instrument will have a point-source imaging sensitivity of about 29 mag; with the laser metrology system, astrometry at the microarcsecond level will be possible.

Colavita, M. M.↗

Advanced technology development multi-color holography

This is the final report of the Multi-color Holography project. The comprehensive study considers some strategic aspects of multi-color holography. First, various methods of available techniques for accurate fringe counting are reviewed. These are heterodyne interferometry, quasi-heterodyne interferometry, and phase-shifting interferometry. Phase-shifting interferometry was found to be the most suitable for multi-color holography. Details of experimentation with a sugar solution are also reported where better than 1/200 of a fringe order measurement capability was established. Rotating plate glass phase shifter was used for the experimentation. The report then describes the possible role of using more than two wavelengths with special reference-to-object beam intensity ratio needs in multicolor holography. Some specific two- and three-color cases are also described in detail. Then some new analysis methods of the reconstructed wavefront are considered. These are deflectometry, speckle metrology, confocal optical signal processing, and phase shifting technique related applications. Finally, design aspects of an experimental breadboard are presented.

Vikram, Chandra S.↗

White-light Interferometry using a Channeled Spectrum: II. Calibration Methods, Numerical and Experimental Results

In the companion paper, [Appl. Opt. 46, 5853 (2007)] a highly accurate white light interference model was developed from just a few key parameters characterized in terms of various moments of the source and instrument transmission function. We develop and implement the end-to-end process of calibrating these moment parameters together with the differential dispersion of the instrument and applying them to the algorithms developed in the companion paper. The calibration procedure developed herein is based on first obtaining the standard monochromatic parameters at the pixel level: wavenumber, phase, intensity, and visibility parameters via a nonlinear least-squares procedure that exploits the structure of the model. The pixel level parameters are then combined to obtain the required 'global' moment and dispersion parameters. The process is applied to both simulated scenarios of astrometric observations and to data from the microarcsecond metrology testbed (MAM), an interferometer testbed that has played a prominent role in the development of this technology.

phase correction↗

Keck Interferometer status and plans

Keck Interferometer is a NASA-funded project to combine the two 10 m Keck telescopes for high sensitivity near-infrared fringe visibility measurements, nulling interferometry at 10 µm to measure the quantity of exozodiacal emission around nearby stars, and differential-phase measurements to detect "hot-Jupiters" by their direct emission. Recent activity has included formal visibility mode commissioning, as well as science observations, and we briefly review some of the significant technical aspects and updates to the system. We have also completed laboratory development of the nuller. The nuller uses two modified Mach-Zehnder input nullers, a Michelson cross combiner, and a 10 µm array camera to produce background-limited null measurements. To provide required temporal stability for the nuller, the system incorporates end-to-end laser metrology with phase referencing from two 2.2 µm fringe trackers. The nuller recently completed its pre-ship review and is being installed on the summit. After nuller integration and test, the differential phase mode will be deployed, which uses a 2-5 µm fringe detector in combination with a precision path length modulator and a vacuum delay line for dispersion control.

Akeson, Rachel L.↗

Indirect planet detection with ground-based long-baseline interferometry

Narrow-angle astrometry with long-baseline infrared interferometers can provide extremely high accuracies as required for indirect planet detection. Narrow-angle astrometric interferometry exploits the properties of atmospheric turbulence over fields smaller than the interferometer baseline divided by the atmospheric scale height. For such fields, accuracy is linear with star separation, and nearly inversely proportional to baseline length. To exploit these properties, the interferometer observes a relatively bright (less than 13 mag(sub K)) target in the near infrared at 2.2 micrometers, and uses phase referencing to find a reference star within the 2.2-micrometers isoplanatic patch. With this technique faint references can be found for most targets. With baselines greater than 100 m, which also minimize photon-noise errors, and with careful control of systematic errors by using laser metrology, accuracies of tens of microarcseconds/square root of (hour) should be possible.

Colavita, M. M.↗

SIM testbed 3 real-time control software

SIM System Testbed 3 (STB3) features three optical interferometers sharing a common baseline, as a dynamic representation of the SIM instrument. An artificial star feeding the interferometers is installed on a separate optics bench. All three interferometers use photons captured by avalanche photo diodes (APDs) to measure the position and quality of fringes, and additional pointing precision is achieved by fast steering mirrors (FSMs) that keep the star images centered on the beam combining optics using a CCD camera. Each interferometer uses internal metrology to measure changes in its optical pathlength. External metrology beams measure changes in the baseline vector. This system acquires and tracks white light fringes with one interferometer, while the other two acquire and track laser light fringes representing the bright guide stars that will be used by SIM. The white light source represents a dim star that cannot supply enough photons for the Science interferometer to lock onto fringes in closed-loop mode; instead it operates open-loop, using pathlength corrections fed to it from the two guide interferometers and the external metrology subsystem to reject disturbances and maintain the fringes. This tracking mode is known as Pathlength Feed Forward (PFF). The precise real-time behavior required to achieve this result is implemented by a complex set of interacting software control loops. This paper describes how these loops take advantage of the benefits of the RTC Core architecture, and how they work together to accomplish STB3's objectives.

interferometry↗

SIM Lite: Ground Alignment of the Instrument

We present the start of the ground alignment plan for the SIM Lite Instrument. We outline the integration and alignment of the individual benches on which all the optics are mounted, and then the alignment of the benches to form the Science and Guide interferometers. The Instrument has a guide interferometer with only a 40 arc-seconds field of regard, and 200 arc-seconds of alignment adjustability. This requires each sides of the interferometer to be aligned to a fraction of that, while at the same time be orthogonal to the baseline defined by the External Metrology Truss. The baselines of the Science and Guide interferometers must also be aligned to be parallel. The start of these alignment plans is captured in a SysML Instrument System model, in the form of activity diagrams. These activity diagrams are then related to the hardware design and requirements. We finish with future plans for the alignment and integration activities and requirements.

Alignment plan↗

Measurement Via Optical Near-Nulling and Subaperture Stitching

A subaperture stitching interferometer system provides near-nulling of a subaperture wavefront reflected from an object of interest over a portion of a surface of the object. A variable optical element located in the radiation path adjustably provides near-nulling to facilitate stitching of subaperture interferograms, creating an interferogram representative of the entire surface of interest. This enables testing of aspheric surfaces without null optics customized for each surface prescription. The surface shapes of objects such as lenses and other precision components are often measured with interferometry. However, interferometers have a limited capture range, and thus the test wavefront cannot be too different from the reference or the interference cannot be analyzed. Furthermore, the performance of the interferometer is usually best when the test and reference wavefronts are nearly identical (referred to as a null condition). Thus, it is necessary when performing such measurements to correct for known variations in shape to ensure that unintended variations are within the capture range of the interferometer and accurately measured. This invention is a system for nearnulling within a subaperture stitching interferometer, although in principle, the concept can be employed by wavefront measuring gauges other than interferometers. The system employs a light source for providing coherent radiation of a subaperture extent. An object of interest is placed to modify the radiation (e.g., to reflect or pass the radiation), and a variable optical element is located to interact with, and nearly null, the affected radiation. A detector or imaging device is situated to obtain interference patterns in the modified radiation. Multiple subaperture interferograms are taken and are stitched, or joined, to provide an interferogram representative of the entire surface of the object of interest. The primary aspect of the invention is the use of adjustable corrective optics in the context of subaperture stitching near-nulling interferometry, wherein a complex surface is analyzed via multiple, separate, overlapping interferograms. For complex surfaces, the problem of managing the identification and placement of corrective optics becomes even more pronounced, to the extent that in most cases the null corrector optics are specific to the particular asphere prescription and no others (i.e. another asphere requires completely different null correction optics). In principle, the near-nulling technique does not require subaperture stitching at all. Building a near-null system that is practically useful relies on two key features: simplicity and universality. If the system is too complex, it will be difficult to calibrate and model its manufacturing errors, rendering it useless as a precision metrology tool and/or prohibitively expensive. If the system is not applicable to a wide range of test parts, then it does not provide significant value over conventional null-correction technology. Subaperture stitching enables simpler and more universal near-null systems to be effective, because a fraction of a surface is necessarily less complex than the whole surface (excepting the extreme case of a fractal surface description). The technique of near-nulling can significantly enhance aspheric subaperture stitching capability by allowing the interferometer to capture a wider range of aspheres. More over, subaperture stitching is essential to a truly effective near-nulling system, since looking at a fraction of the surface keeps the wavefront complexity within the capability of a relatively simple nearnull apparatus. Furthermore, by reducing the subaperture size, the complexity of the measured wavefront can be reduced until it is within the capability of the near-null design.

Forbes, Greg↗

Fast quantum interferometry at the nanometer and attosecond scales with energy-entangled photons

In classical optical interferometry, loss and background complicate achieving fast nanometer-resolution measurements with illumination at low light levels. Conversely, quantum two-photon interference is unaffected by loss and background, but nanometer-scale resolution is physically difficult to realize. As a solution, we enhance two-photon interference with highly nondegenerate energy entanglement featuring photon frequencies separated by 177 THz. We observe measurement resolution at the nanometer (attosecond) scale with only O(10 4 ) photon pairs, despite the presence of background and loss. Our nondestructive thickness measurement of a metallic thin film agrees with atomic force microscopy, which often achieves better resolution via destructive means. With contactless, nondestructive measurements in seconds or faster, our instrument enables metrological studies in optically challenging contexts where background, loss, or photosensitivity are factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Validation of High Precision Thermal, Mechanical, and Optical Models for the Space Interferometry Mission

SIM Planetquest (SIM) is a large optical interferometer for making microarcsecond measurements of the positions of stars, and to detect Earth-sized planets around nearby stars. To achieve this precision, SIM requires stability of optical components to tens of picometers per hour. The combination of SIM s large size (9 meter baseline) and the high stability requirement makes it difficult and costly to measure all aspects of system performance on the ground. To reduce risks, costs and to allow for a design with fewer intermediate testing stages, the SIM project is developing an integrated thermal, mechanical and optical modeling process that will allow predictions of the system performance to be made at the required high precision. This modeling process uses commercial, off-the-shelf tools and has been validated against experimental results at the precision of the SIM performance requirements. This paper presents the description of the model development, some of the models, and their validation in the Thermo-Opto-Mechanical (TOM3) testbed which includes full scale brassboard optical components and the metrology to test them at the SIM performance requirement levels.

astronomy↗

Enhancing strontium clock atom interferometry using quantum optimal control

Strontium clock atom interferometry is a promising new technology, with multiple experiments under development around the world to explore its potential for dark matter and gravitational wave detection. In these detectors, large momentum transfer using sequences of many laser pulses is necessary, and thus high-fidelity pulses are important since small errors become magnified. Quantum optimal control (QOC) is a framework for developing control pulse waveforms that achieve high fidelity and are robust against experimental imperfections. Resonant single-photon transitions using the narrow clock transition of strontium involve significantly different quantum dynamics than more established atom interferometry methods based on far-detuned two-photon Raman or Bragg transitions, which leads to new opportunities and challenges when applying QOC. Here, we study in simulation QOC pulses for strontium clock interferometry and demonstrate their advantage over basic square pulses (primitive pulses) and composite pulses in terms of robustness against multiple noise channels. In conclusion, this could improve the scale of large momentum transfer in Sr clock interferometers, paving the way to achieving these scientific goals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of full-aperture interferometry to sub-aperture stitched interferometry for a large diameter fast mirror

The Herschel Space Observatory (formerly known as FIRST) consists of a 3.5 m space telescope. Stitching sub aperture interferograms may offer considerable cost savings during testing of the flight telescope as compared to other techniques. A comparative demonstration is presented of interferogram stitching techniques that enable a composite map of a 3-D surface to be assembled from a sequence of sub-aperture measurements. This paper describes the fundamental procedures for stitching together component data sets and demonstrates such techniques with real data sets.

carbon fiber composite cryogenic optics high slope↗

Mid-IR interferometric nulling for TPF

By the middle of 2006, the Interferometry Technology development program for NASA’s Terrestrial Planet Finder (TPF) Mission has the goal of demonstrating deep and stable interferometric nulling of broadband Mid-IR thermal radiation under conditions that are traceable to the expected on-orbit conditions. Specifically, the task is to demonstrate null levels of 10 to the negative 6 power, with a 50% BW centered at 10 um, with null stabilities of 10 to the negative 7 power all at cryogenic temperatures for observational periods of a couple of hours. The Achromatic Nulling activity at JPL addresses this concern in two testbeds: the warm nulling testbed and the cryonulling testbed. The warm nulling testbed will demonstrate the physics of nulling broadband thermal sources in an environment that is conducive to efficient research. We’ll explore nulling techniques, optical-mechanical alignment methods, motion control, and path-length metrology for a single beam interferometer, as well as preliminary planet detection techniques. Ultimate nulling capabilities under conditions that are more flight-like will be demonstrated in cryogenic nulling testbed. Knowledge gained from operation at room temperature will be applied to the cryongenic experiment where we face the additional challenges of extreme temperatures, cryongenic actuators, component survivability and fluxes that are within an order of magnitude of expected flux levels on orbit. Concurrently, we will develop a low flux mid-IR camera that will allow us to measure the nulls at these faint photon fluxes. This talk will review this development activity and will include recent nulling experimental results and plans for future work.

Vasisht, Gautam↗

The Space Interferometry Mission

The Space Interferometry Mission (SIM) is the next major space mission in NASA's Origins program after SIRTF. The SIM architecture uses three Michelson interferometers in low-earth orbit to provide 4 microarcsecond precision absolute astrometric measurements on approx. 40,000 stars. SIM will also provide synthesis imaging in the visible waveband to a resolution of 10 milliarcsecond, and interferometric nulling to a depth of 10(exp -4). A near-IR (1-2 micron) capability is being considered. Many key technologies will be demonstrated by SIM that will be carried over directly or can be readily scaled to future Origins missions such as TPF. The SIM spacecraft will carry a triple Michelson interferometer with baselines in the 10 meter range. Two interferometers act as high precision trackers, providing attitude information at all time, while the third one conducts the science observations. Ultra-accurate laser metrology and active systems monitor the systematic errors and to control the instrument vibrations in order to reach the 4 microarcsecond level on wide-angle measurements. SIM will produce a wealth of new astronomical data. With an absolute positional precision of 4 microarcsecond, SIM will improve on the best currently available measures (the Hipparcos catalog) by 2 or 3 orders of magnitude, providing parallaxes accurate to 10% and transverse velocities to 0.2 km/s anywhere in the Galaxy, to stars as faint as 20th magnitude. With the addition of radial velocities, knowledge of the 6-dimension phase space for objects of interest will allow us to attack a wide array of previously inaccessible problems such as: search for planets down to few earth masses; calibration of stellar luminosities and by means of standard candles, calibration of the cosmic distance scale; detecting perturbations due to spiral arms, disk warps and central bar in our galaxy; probe of the gravitational potential of the Galaxy, several kiloparsecs out of the galactic plane; synthesis imaging of circumstellar disks around young stellar objects; imaging the narrow-line regions of AGNs in the optical; direct distance determination of a half dozen nearby spiral galaxies using rotational kinematics, thereby sidestepping reddening and metallicity issues in the calibration of distance estimators like Tully-Fisher; imaging exozodiacal dust disks (when operating in its nulling mode, SIM will be sensitive, at a distance of (beta) Pic (20 pc), to scales ranging from 0.2 to 5 AU).

Unwin, Stephen C.↗

Nulling at the Keck Interferometer

The nulling mode of the Keck Interferometer is being commissioned at the Mauna Kea summit. The nuller combines the two Keck telescope apertures in a split-pupil mode to both cancel the on-axis starlight and to coherently detect the residual signal. The nuller, working at 10 um, is tightly integrated with the other interferometer subsystems including the fringe and angle trackers, the delay lines and laser metrology, and the real-time control system. Since first 10 um light in August 2004, the system integration is proceeding with increasing functionality and performance, leading to demonstration of a 100:1 on-sky null in 2005. That level of performance has now been extended to observations with longer coherent integration times. An overview of the overall system is presented, with emphasis on the observing sequence, phasing system, and differences with respect to the V2 system, along with a presentation of some recent engineering data.

interferometry↗

Investigation of Space Interferometer Control Using Imaging Sensor Output Feedback

Numerous space interferometry missions are planned for the next decade to verify different enabling technologies towards very-long-baseline interferometry to achieve high-resolution imaging and high-precision measurements. These objectives will require coordinated formations of spacecraft separately carrying optical elements comprising the interferometer. High-precision sensing and control of the spacecraft and the interferometer-component payloads are necessary to deliver sub-wavelength accuracy to achieve the scientific objectives. For these missions, the primary scientific product of interferometer measurements may be the only source of data available at the precision required to maintain the spacecraft and interferometer-component formation. A concept is studied for detecting the interferometer's optical configuration errors based on information extracted from the interferometer sensor output. It enables precision control of the optical components, and, in cases of space interferometers requiring formation flight of spacecraft that comprise the elements of a distributed instrument, it enables the control of the formation flying vehicles because independent navigation or ranging sensors cannot deliver the high-precision metrology over the entire required geometry. Since the concept can act on the quality of the interferometer output directly, it can detect errors outside the capability of traditional metrology instruments, and provide the means needed to augment the traditional instrumentation to enable enhanced performance. Specific analyses performed in this study include the application of signal-processing and image-processing techniques to solve the problems of interferometer aperture baseline control, interferometer pointing, and orientation of multiple interferometer aperture pairs.

Cheng, Victore H. L.↗

Investigation of Space Interferometer Control Using Imaging Sensor Output Feedback

Numerous space interferometry missions are planned for the next decade to verify different enabling technologies towards very-long-baseline interferometry to achieve high-resolution imaging and high-precision measurements. These objectives will require coordinated formations of spacecraft separately carrying optical elements comprising the interferometer. High-precision sensing and control of the spacecraft and the interferometer-component payloads are necessary to deliver sub-wavelength accuracy to achieve the scientific objectives. For these missions, the primary scientific product of interferometer measurements may be the only source of data available at the precision required to maintain the spacecraft and interferometer-component formation. A concept is studied for detecting the interferometer's optical configuration errors based on information extracted from the interferometer sensor output. It enables precision control of the optical components, and, in cases of space interferometers requiring formation flight of spacecraft that comprise the elements of a distributed instrument, it enables the control of the formation-flying vehicles because independent navigation or ranging sensors cannot deliver the high-precision metrology over the entire required geometry. Since the concept can act on the quality of the interferometer output directly, it can detect errors outside the capability of traditional metrology instruments, and provide the means needed to augment the traditional instrumentation to enable enhanced performance. Specific analyses performed in this study include the application of signal-processing and image-processing techniques to solve the problems of interferometer aperture baseline control, interferometer pointing, and orientation of multiple interferometer aperture pairs.

Leitner, Jesse A.↗

Mitigation of Angle Tracking Errors Due to Color Dependent Centroid Shifts in SIM-Lite

The SIM-Lite astrometric interferometer will search for Earth-size planets in the habitable zones of nearby stars. In this search the interferometer will monitor the astrometric position of candidate stars relative to nearby reference stars over the course of a 5 year mission. The elemental measurement is the angle between a target star and a reference star. This is a two-step process, in which the interferometer will each time need to use its controllable optics to align the starlight in the two arms with each other and with the metrology beams. The sensor for this alignment is an angle tracking CCD camera. Various constraints in the design of the camera subject it to systematic alignment errors when observing a star of one spectrum compared with a start of a different spectrum. This effect is called a Color Dependent Centroid Shift (CDCS) and has been studied extensively with SIM-Lite's SCDU testbed. Here we describe results from the simulation and testing of this error in the SCDU testbed, as well as effective ways that it can be reduced to acceptable levels.

Spectral↗