Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image plates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

Compression of bulk metallic glass Zr[subscript 57]Cu[subscript 15.4]Ni[subscript 12.6]Al[subscript 10]Nb[subscript 5] to 122 GPa

Ultra high pressure X-ray diffraction studies have been carried out on group IV transition metals-based bulk metallic glass (BMG) Zr{sub 57}Cu{sub 15.4}Ni{sub 12.6}Al{sub 10}Nb{sub 5} to a pressure of 122 GPa at ambient temperature in a diamond anvil cell. Image plate X-ray diffraction studies under high pressure were carried out at a synchrotron source and the two BMG diffraction bands can be followed to the highest pressure using an internal copper pressure standard. Our experiments show that the BMG is stable to compression as high as 40% and thermal activation is needed to nucleate nanostructures/crystallization under extreme conditions. The fit to the Birch-Murnaghan equation of state gives bulk modulus (B{sub 0}) = 116 GPa and its pressure derivative B' = 3.04. The measured differential radial distribution function shows gradual compression of the shell structures in the BMG to extreme compressions.

36 MATERIALS SCIENCE↗

Measuring the angular dependence of betatron x-ray spectra in a laser-wakefield accelerator

This paper presents a new technique to measure the angular dependence of betatron x-ray spectra in a laser-wakefield accelerator. Measurements are performed with a stacked image plates spectrometer, capable of detecting broadband x-ray radiation up to 1 MeV. It can provide measurements of the betatron x-ray spectrum at any angle of observation (within a 40 mrad cone) and of the beam profile. A detailed description of our data analysis is given, along with comparison for several shots. As a result, these measurements provide useful information on the dynamics of the electrons are they are accelerated and wiggled by the wakefield.

42 ENGINEERING↗

Energy resolution of the CdTe-XPAD detector:calibration and potential for Laue diffractionmeasurements on protein crystals

The XPAD3S-CdTe, a CdTe photon-counting pixel array detector, has been used to measure the energy and the intensity of the white-beam diffraction from a lysozyme crystal. A method was developed to calibrate the detector in terms of energy, allowing incident photon energy measurement to high resolution (approximately 140 eV), opening up new possibilities in energy-resolved X-ray diffraction. In order to demonstrate this, Laue diffraction experiments were performed on the bending-magnet beamline METROLOGIE at Synchrotron SOLEIL. The X-ray energy spectra of diffracted spots were deduced from the indexed Laue patterns collected with an imaging-plate detector and then measured with both the XPAD3S-CdTe and the XPAD3S-Si, a silicon photon-counting pixel array detector. The predicted and measured energy of selected diffraction spots are in good agreement, demonstrating the reliability of the calibration method. These results open up the way to direct unit-cell parameter determination and the measurement of high-quality Laue data even at low resolution. Based on the success of these measurements, potential applications in X-ray diffraction opened up by this type of technology are discussed.

36 MATERIALS SCIENCE↗

Crystal structure of nacrite from the electron diffraction data

The crystal structure of the nacrite mineral of the kaolin group (space group Cc; R = 2.76%; 634 unique reflections) is refined from the digital oblique-texture electron diffraction patterns obtained with the use of imaging plates. The maxima characterizing the locations and potentials of the hydrogen atoms of the hydroxyl groups are revealed from the difference Fourier-potential syntheses. The O-H interatomic distances and the angles of inclination of the O-H bond with respect to the ab plane are equal to 0.97 A and -18.3 deg. for the inner hydroxyl group and 0.92, 0.85, 0.93 A and 60.8 deg., 67.8 deg., 58.4 deg. for the outer hydroxyl groups, respectively. The O{sub donor}-O{sub acceptor} interatomic distances are 2.940, 2.949, and 3.121 A. It is established that the electrostatic potential distributions of the hydrogen atoms of the inner hydroxyl group and one of the outer hydroxyl groups located in the vicinity of the symmetry pseudoplane m of the layer are characterized by anisotropy, which can indicate a statistical distribution of these hydrogen atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

D-25 OBSERVATIONS OF SHOCKED METALLIC SURFACES WITH SINGLE-PULSE X-RAY DIFFRACTION

A single-pulse x-ray diffraction (XRD) diagnostic has been developed for the investigation of shocked material properties on a very short time scale. The diagnostic, which consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, produces line and bremsstrahlung x-ray emission in a 40-ns pulse. A selected anode of either silver or molybdenum produces characteristic K lines used for diffraction. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 2-mm by 5-mm spot and 1° full-width-half-maximum angular divergence. Coherent scattering from the sample produces a Debye-Scherrer diffraction pattern on an image plate 75 mm from the polycrystalline sample surface. An experimental study of the polycrystalline structures of zirconium and tin under high-pressure shock loading has been conducted with single-pulse XRD. The experimental targets were 0.1-mm-thick foils of zirconium and tin using 0.4-mm-thick vitreous carbon back windows for shock-loading, and the shocks were produced by either Detasheet or PBX-9501 high explosives buffered by 1-mm-thick 6061-T6 aluminum. The diffraction patterns from both shocked zirconium and tin indicated a phase transition into a polymorphic mix of amorphous and new solid phases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observations of Shock-Loaded Tin and Zirconium Surfaces with Single-Pulse X-ray Diffraction

A single-pulse X-ray diffraction (XRD) diagnostic has been developed for the investigation of shocked material properties on a very short time scale. The diagnostic, which consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, produces line-and-bremsstrahlung X-ray emission in a 40 ns pulse. The molybdenum anode produces 0.71 Å characteristic K lines used for diffraction. The X-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 2 mm×5 mm spot and 1° full width at half maximum angular divergence. Coherent scattering from the sample produces a Debye-Scherrer diffraction pattern on an image plate located at 75 mm from the polycrystalline sample surface. An experimental study of the polycrystalline structures of zirconium and tin under high-pressure shock loading has been conducted with single-pulse XRD. The experimental targets were 0.1-mm-thick foils of zirconium and tin using 0.4-mm-thick vitreous carbon back windows for shock loading, and the shocks were produced by either Detasheet or PBX-9501 high explosives buffered by 1-mm-thick 6061-T6 aluminum. The diffraction patterns from both shocked zirconium and tin indicated a phase transition into a polymorphic mix of amorphous and new solid phases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton Radiography Imager:Generates Synthetic Proton Radiographs

ProRad is a computer program that is used to generate synthetic images of proton (or other charged particles) radiographs. The proton radiographs arc images that arc obtained by sending energetic protons (or electrons or positrons, for example) through 11 plasma where electric and/or magnetic fields alter the particles trajectory, Dnd the variations me imaged on RC film, image plate, or equivalent

Wilks, ScottC.↗

Quantifying the uncertainty of synchrotron-based lattice strain measurements

Crystallographic lattice strains - measured using diffraction techniques - are the same magnitude as typical macroscopic elastic strains. From a research perspective, the main interest is in measuring changes in lattice strains induced during in-situ loading: either from one macroscopic stress level to another or from one cycle to the next. The hope is to link these measurements to deformation-induced changes in the internal structure of crystals, possibly related to inelastic deformation and damage. These measurements are relatively new - little experimental intuition exists and it is difficult to discern whether observed differences are due to actual micromechanical evolution or to random experimental fluctuations. If the measurements are linked to material evolution on the size scale of the individual crystal, they have the potential to change the ideas about grain scale deformation partitioning processes and can be used to validate crystal-based simulation frameworks. Therefore, understanding the uncertainty associated with the lattice strain experiments is a crucial step in their continued development. If the measured lattice strains are of the same order as the random fluctuations that are part of the measurement process, documenting the strains can create more confusion than understanding. Often lattice strain error is quoted as {+-}1 x 10{sup -4}. This simple value fails to account for the range of factors that contribute to the experimental uncertainty - which, if not properly accounted for, may lead to a false confidence in the measurements. The focus of this paper is the development of a lattice strain uncertainty expression that delineates the contributing factors into terms that vary independently: (i) the contribution from the instrument and (ii) the contribution from the material under investigation. These aspects of uncertainty are described, and it is then possible to employ a calibrant powder method (diffraction from an unstrained material with high-precision lattice constants) to quantify the instrument portion of the lattice strain uncertainty. In these experiments, the instrument contribution to the uncertainty has been found to be a function of the Bragg angle and the intensity of the diffracted peaks. To develop a model for the instrument portion of the lattice strain uncertainty two datasets obtained using a MAR345 online image plate at the Cornell High Energy Synchrotron Source and a GE 41RT amorphous silicon detector at the Advanced Photon Source have been examined.

43 PARTICLE ACCELERATORS↗

Tritium trapping on the plasma irradiated tungsten surface

Tungsten (W) is a candidate material for plasma-facing high heat-flux structures in future fusion reactors. The aim of this study is to assess how reasonably one can predict the tritium inventory in actual fusion machines using data on the hydrogen isotope inventory obtained in laboratory experiments. W specimens previously exposed to deuterium (D) plasmas both in the TEXTOR tokamak and high flux linear plasma generator (LPG) were subsequently loaded with tritium at 573 K for 3 h. The retention of tritium in the near-surface W layer was examined by imaging plate technique. The study shows that on the TEXTOR-plasma-exposed W surface, tritium was mainly trapped in carbon deposits, and for LPG-plasma-exposed W specimens, tritium was trapped in defects created in the near-surface layer during the course of D plasma exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High x-ray resolving power utilizing asymmetric diffraction from a quartz transmission crystal measured in the 6 keV to 22 keV energy range

We report a Cauchois-type spectrometer utilizing the (203) lattice planes at an oblique angle of 11.53° to the normal to the surface of a quartz transmission crystal recorded the Kα and Kβ spectral lines of six elements from Fe to Ag in the 6–22 keV energy range from a laboratory x-ray source. After deconvolving the natural lifetime widths and the image plate detector broadening from the observed spectral linewidths, the intrinsic crystal resolving power was determined to be 4000 at the lower energies and decreasing to 1000 at the higher energies. Previously, a Si wafer crystal exhibited twice this resolving power when the (331) planes had been used in asymmetric geometry. The investigation of diffraction with this quartz crystal, with a very similar lattice spacing and therefore spectral coverage, was motivated by the larger integrated reflectivity of quartz due to its well-known quasimosaicity upon elastic bending. The measured spectral linewidths were in good agreement with the widths calculated by accounting for various broadening mechanisms, including source size, crystal thickness, crystal height, crystal rocking curve width, geometrical aberrations, and possible spectrometer configuration errors. This is the first, to the best of our knowledge, demonstration of high resolving power achieved by asymmetric diffraction over a wide energy range (6–22 keV) and with detailed comparisons with theoretical broadenings. Finally, based on these results, Cauchois spectrometers employing asymmetric planes of perfect quartz and silicon crystals can be reliably designed and optimized for high-resolution spectroscopy in the >6 keV energy range.

36 MATERIALS SCIENCE↗

NIF S600D Snout Final Design Review (FDR) Report

The S600D is a one or two channel mirror spectrometer which will provide temporal and spatial soft x-ray data in a single NIF shot. It mounts to the existing DIM Imaging Streak Camera (DISC) using the standard NIF kinematic mount design. LLE and LLNL each have responsibilities for the snout. The Laboratory for Laser Energetics (LLE) is subcontracted to design, fabricate, and align the S600D Snout at the OMEGA Laser facility in Rochester, NY before delivery to LLNL. The Snout consists of the Mirror Mount, Kinematic interface to DISC, Slit mount, and filter pack mount. Lawrence Livermore National Laboratory (LLNL) is responsible to fabricate and deliver the Mirror substrates and coatings, Pinhole slits and collimators, Filter material, and Image plates. LLNL is also responsible for the Requirements Definition, Concept of Operations, Debris and Shrapnel analysis, Stakeholder reviews and Integration in the NIF Facility.

42 ENGINEERING↗

Modeling blur in various detector geometries relevant to DARHT

Monte Carlo transport codes have been used to model the detector blur and energy deposition in various detector geometries for MeV radiography which are applicable to DARHT. Segmented scintillator detectors, where low Z scintillators combined with a high-Z metal matrix, are designed such that the resolution increases with increasing metal fraction. The combination of various types of metal intensification screens and storage phosphor imaging plates has also been studied. A storage phosphor coated directly onto a metal intensification screen has superior performance over a commercial plate. Stacks of storage phosphor plates and tantalum intensification screens show an increase in energy deposited and detective quantum efficiency with increasing plate number, at the expense of resolution which degrades with plate number. Excellent agreement between simulation and experimental modulation transfer functions for select detector geometries was found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated scintillator array response to relativistic electrons

In order to make time resolved measurements of the gamma spectra on DARHT Axis 2 using the Compton Spectrometer (CS), the electron detector in the focal plane must be a scintillator that is optically coupled to a gated or streak camera. There are several issues we would like to address with experiments at Idaho Accelerator Center (IAC) before committing to a full size array (7”x2”), which would cost at least $100k. Two candidates for this application are organic (Bicron 422 or equivalent) or inorganic (LYSO) scintillator. Monte Carlo calculations were performed by Rachel Morneau, P-21, using MCNP to compare the two materials each 1.5mm thick for an energy range of 0.1 to 20MeV. The energy loss per particle in LYSO is much larger (100x) than in the plastic scintillator. We confirmed, by performing experiments with the CS on the Microton, that sensitivity of the LYSO was much larger (10x) than the plastic scintillator. Therefore, we have selected LYSO as the scintillator of choice. However, interest in the response of other organic and plastic scintillators prompted an increase in scope of the project. The goals of this experiment were as follows. First, we need to understand the optical response of the scintillators to electrons as a function of thickness, energy, and deposited charge. We also need to verify level of saturation in the scintillation process. Second, compare the scintillators’ response to an image plate (the current CS detector). Third, we need to quantify the effect of signal bleed through to adjacent pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray diffraction of dynamically compressed matter on Sandia's Z Pulsed Power Facility

Sandia's Z Pulsed Power Facility is able to dynamically compress matter to extreme states with exceptional uniformity, duration, and size, which are ideal for investigations of fundamental material properties of high energy density conditions. X-ray diffraction (XRD) is a key atomic scale probe since it provides direct observation of the compression and strain of the crystal lattice, and is used to detect, identify, and quantify phase transitions. Because of the destructive nature of Z-Dynamic Materials Properties (DMP) experiments and low signal vs background emission levels of XRD, it is very challenging to detect the XRD pattern close to the Z-DMP load and to recover the data. We developed a new Spherical Crystal Diffraction Imager (SCDI) diagnostic to relay and image the diffracted x-ray pattern away from the load debris field. The SCDI diagnostic utilizes the Z-Beamlet laser to generate 6.2-keV Mn-He c , x-rays to probe a shock-compressed sample on the Z-DMP load. A spherically bent crystal composed of highly oriented pyrolytic graphite is used to collect and focus the diffracted x-rays into a 1-inch thick tungsten housing, where an image plate is used to record the data. We performed experiments to implement the SCDI diagnostic on Z to measure the XRD pattern of shock compressed beryllium samples at pressures of 1.8-2.2 Mbar.

36 MATERIALS SCIENCE↗

Multi-Probe 23A: Post shot Data and Analysis

The Multi-Probe 23A experiments took place on the Omega EP laser in December 2022. The experiments consisted of shots alternating between Omega EP’s two short-pulse laser beams to generate proton and deuteron beams from a variety of film and foam targets. The backlighter was used in the pitcher series, in which deuteron beams were generated to develop a pitcher for a pitcher-catcher neutron radiographic source. The sidelighter was used in the shielding series, in which proton beams was generated, and a metal shield, XBLK, was used to mitigate crosstalk between the proton target and image plates located perpendicularly to the proton beam axis. For the pitcher series, we found that we were able to generate a deuteron beam with CD film, but not CD foam, targets. For the shielding series, we found that 6 mm Al vastly outperformed similar thicknesses of Cu and Ta at mitigating the crosstalk, suggesting that electrons, rather than x-rays, are the primary source of crosstalk.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗