Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

SU-F-T-592: A Delivery QA-Free Approach for Adaptive Therapy of Prostate Cancer with Static Intensity Modulated Radiotherapy

Purpose: Clinical implementations of adaptive radiotherapy (ART) are limited mainly by the requirement of delivery QA (DQA) prior to the treatment. Small segment size and small segment MU are two dominant factors causing failures of DQA. The aim of this project is to explore the feasibility of ART treatment without DQA by using a partial optimization approach. Methods: A retrospective simulation study was performed on two prostate cancer patients treated with SMLC-IMRT. The prescription was 180cGx25 fractions with daily CT-on-rail imaging for target alignment. For each patient, seven daily CTs were selected randomly across treatment course. The contours were deformablely transferred from the simulation CT onto the daily CTs and modified appropriately. For each selected treatment, dose distributions from original beams were calculated on the daily treatment CTs (DCT plan). An ART plan was also created by optimizing the segmental MU only, while the segment shapes were preserved and the minimum MU constraint was respected. The overlaps, between PTV and the rectum, between PTV and the bladder, were normalized by the PTV volume. This ratio was used to characterize the difficulty of organs-at-risk (OAR) sparing. Results: Comparing to the original plan, PTV coverage was compromised significantly in DCT plans (82% ± 7%) while all ART plans preserved PTV coverage. ART plans showed similar OAR sparing as the original plan, such as V40Gy=11.2cc (ART) vs 11.4cc (original) for the rectum and D10cc=4580cGy vs 4605cGy for the bladder. The sparing of the rectum/bladder depends on overlap ratios. The sparing in ART was either similar or improved when overlap ratios in treatment CTs were smaller than those in original plan. Conclusion: A partial optimization method is developed that may make the real-time ART feasible on selected patients. Future research is warranted to quantify the applicability of the proposed method.

60 APPLIED LIFE SCIENCES↗

Analysis of ERTS-1 linear features in New York State

The author has identified the following significant results. All ERTS-1 linears confirmed to date have topographic expression although they may appear as featureless tonal linears on the imagery. A bias is unavoidably introduced against any linears which may parallel raster lines, lithological trends, or the azimuth of solar illumination. Ground study of ERTS-1 topographic lineaments in the Adirondacks indicates: outcrops along linears are even more rare than expected, fault breccias are found along some NNE lineaments, chloritization and slickensiding without brecciation characterize one EW lineament whereas closely-spaced jointing plus a zone of plastic shear define another. Field work in the Catskills suggests that the prominent new NNE lineaments may be surface manifestations of normal faulting in the basement, and that it may become possible to map major joint sets over extensive plateau regions directly on the imagery. Fall and winter images each display some unique linears, and long linears on the fall image commonly appear as aligned segments on the winter scene. A computer-processed color composite image permitted the extraction or additional information on the shaded side of mountains.

Isachsen, Y. W.↗

Methods, advantages, and limitations of compositing photographic images

Basic procedures used in compositing photographic images to increase their information content are briefly discussed. A new method for calculating exposure time for each image is presented. A portion of the density coordinate of the characteristic curve of the film on which the exposures are to be made is divided into as many divisions as there are images to be superimposed. Lines are drawn from the intersections of these density increments with the characteristic curve to the log exposure for each image. A study of the ability of workers to superimpose plant images with a projected scale of one arcsec per millimeter has shown that image smearing due to alignment errors in a composite will not exceed about 0.15 arcseconds if images are composited by an adept operator.

Jones, S. E.↗

Acquisition, tracking, and pointing; Proceedings of the Meeting, Orlando, FL, Apr. 3, 4, 1986

The present conference discusses the effect of target signatures on active tracking, the high resolution obtainable with a two-degrees-of-freedom angle sensor having a high update rate, solar object tracking for the Hubble Space Telescope, scaled experiments for the assessment of precise active tracking, and large aperture high-accuracy satellite laser tracking. Also discussed are laboratory test results for the Spaceborne Geodynamic Ranging System's high speed optical tracking system, jitter stabilization for precise optical pointing, scan stabilization and jitter control for an airborne telescope, a simulation of the Solar Optical Telescope's pointing performance, a microprocessor-based dual-speed angle converter, and image localization for alignment by means of adaptive preprocessing.

Auelmann, Richard R.↗

A model of electronic map interpretation

This paper describes an experiment that provides data for the development of a cognitive model of pilot flight navigation. The model views navigation as a process involving the alignment of mental images with the perceptual view out of the cockpit. The data support a three stage model: (1) the perceptual encoding of the map display, (2) mental rotation of the mental image, and (3) comparison of the image to the environment. The variables that significantly influence the processes embodied in the model in decreasing importance are: speed of processing, display sequencing, map complexity, and rotation angle of the map. The model can be used as a preliminary computational tool in predicting the navigational component of pilot situational awareness.

Aretz, Anthony J.↗

Three dimensional landmark templates

Three-dimensional surface templates are being used to identify and locate landmarks on Mars and Phobos. They can be aligned both with images and the MOLA map to help tie these two data types together. The Martian templates form a control network of well-defined and easily identified landmarks.

landmarks Mars Phobos MOLA three-dimensional surfa↗

Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems

A technique was created to measure the pupil alignment of instruments in situ by measuring calibrated pupil alignment references (PARs) in instruments. The PAR can also be measured using an alignment telescope or an imaging system. PAR allows the verification of the science instrument (SI) pupil alignment at the integrated science instrument module (ISIM) level of assembly at ambient and cryogenic operating temperature. This will allow verification of the ISIM+SI alignment, and provide feedback to realign the SI if necessary.

Hagopian, John G.↗

Implementation of Pin Point Landing Vision Components in an FPGA System

Pin-point landing is required to enable missions to land close, typically within 10 meters, to scientifically important targets in generally hazardous terrain. In Pin Point Landing both high accuracy and high speed estimation of position and orientation is needed to provide input to the control system to safely choose and navigate to a safe landing site. A proposed algorithm called VISion aided Inertial NAVigation (VISINAV) has shown that the accuracy requirements can be met. [2][3] VISINAV was shown in software only, and was expected to use FPGA enhancements in the future to improve the computational speed needed for pin point landing during Entry Descent and Landing (EDL). Homography, feature detection and spatial correlation are computationally intensive parts of VISINAV. Homography aligns the map image with the descent image so that small correlation windows can be used, and feature detection provides regions that spatial correlation can track from frame to frame in order to estimate vehicle motion. On MER the image Homography, Feature Detection and Correlation would take approximately 650ms tracking 75 features between frames. We implemented Homography, Feature detection and Correlation on a Virtex 4 LX160 FPGA to run in under 25ms while tracking 500 features to improve algorithm reliability and throughput.

aircraft landing guidance↗

MatchGUI: A Graphical MATLAB-Based Tool for Automatic Image Co-Registration

MatchGUI software, based on MATLAB, automatically matches two images and displays the match result by superimposing one image on the other. A slider bar allows focus to shift between the two images. There are tools for zoom, auto-crop to overlap region, and basic image markup. Given a pair of ortho-rectified images (focused primarily on Mars orbital imagery for now), this software automatically co-registers the imagery so that corresponding image pixels are aligned. MatchGUI requires minimal user input, and performs a registration over scale and inplane rotation fully automatically

Ansar, Adnan I.↗

Miniaturized GPS/MEMS IMU integrated board

This invention documents the efforts on the research and development of a miniaturized GPS/MEMS IMU integrated navigation system. A miniaturized GPS/MEMS IMU integrated navigation system is presented; Laser Dynamic Range Imager (LDRI) based alignment algorithm for space applications is discussed. Two navigation cameras are also included to measure the range and range rate which can be integrated into the GPS/MEMS IMU system to enhance the navigation solution.

Lin, Ching-Fang↗

Measuring Temperature-Dependent Propagating Disturbances in Coronal Fan Loops Using Multiple SDO-AIA Channels and Surfing Transform Technique

A set of co-aligned high resolution images from the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamics Observatory (SDO) is used to investigate propagating disturbances (PDs) in warm fan loops at the periphery of a non-flaring active region NOAA AR 11082. To measure PD speeds at multiple coronal temperatures, a new data analysis methodology is proposed enabling quantitative description of sub visual coronal motions with low signal-to-noise ratios of the order of 0.1. The technique operates with a set of one-dimensional surfing signals extracted from position-timeplots of several AIA channels through a modified version of Radon transform. The signals are used to evaluate a two-dimensional power spectral density distribution in the frequency - velocity space which exhibits a resonance in the presence of quasi-periodic PDs. By applying this analysis to the same fan loop structures observed in several AIA channels, we found that the traveling velocity of PDs increases with the temperature of the coronal plasma following the square root dependence predicted for the slow mode magneto-acoustic wave which seems to be the dominating wave mode in the studied loop structures. This result extends recent observations by Kiddie et al. (2012) to a more general class of fan loop systems not associated with sunspots and demonstrating consistent slow mode activity in up to four AIA channels.

Solar Corona↗

Dynamic Analysis of Reynolds Number Effects on Trailing Edge Transonic Vortex Shedding and Its Impact on Turbine Blade Aerodynamic Performance

Time-resolved, high-speed self-aligned focusing schlieren images were acquired in the NASA Glenn Research Center Transonic Turbine Blade Cascade facility to help understand the aerodynamic behavior of high-pressure, thick trailing edge turbine blades. The trailing edge thickness of 9% of axial chord tested represents simulated ceramic matrix composite fabrication constraints, which was verified previously to possess a high-loss flow regime at high inlet turbulence conditions over a narrow range of Reynolds numbers and at a fixed design exit Mach number of 0.74. Our high-speed images, which were acquired at 10 distinct Reynolds numbers, show a significant increase in energy from flow oscillations due to transonic vortex shedding at Reynolds numbers corresponding to the high loss conditions. For those conditions, strong acoustic waves turn into shock waves. Spectral Proper Orthogonal Decomposition of the high-speed images shows acoustic waves from trailing edge vortex shedding at all conditions, with increased spectral energy at the high-loss conditions and slightly increasing frequency (about 6%) as a function of Reynolds number. Analysis of potential feedback timing is performed using velocity fields from a previous LES simulation, considering different feedback mechanisms. Most noteworthy is the acoustic/shock-boundary layer interaction mechanism on the suction surface at the blade geometric throat, which likely plays an important role in realistic curved blade passages.

Trailing Edge↗

Optical alignment of electrodes on electrical discharge machines

Shadowgraph system projects magnified image on screen so that alignment of small electrodes mounted on electrical discharge machines can be corrected and verified. Technique may be adapted to other machine tool equipment where physical contact cannot be made during inspection and access to tool limits conventional runout checking procedures.

Boissevain, A. G.↗

WE-EF-303-10: Single- Detector Proton Radiography as a Portal Imaging Equivalent for Proton Therapy

Purpose: In proton therapy, patient alignment is of critical importance due to the sensitivity of the proton range to tissue heterogeneities. Traditionally proton radiography is used for verification of the water-equivalent path length (WEPL), which dictates the depth protons reach. In this work we propose its use for alignment. Additionally, many new proton centers have cone-beam computed tomography in place of beamline X-ray imaging and so proton radiography offers a unique patient alignment verification similar to portal imaging in photon therapy. Method: Proton radiographs of a CIRS head phantom were acquired using the Beam Imaging System (BIS) (IBA, Louvain-la-Neuve) in a horizontal beamline. A scattered beam was produced using a small, dedicated, range modulator (RM) wheel fabricated out of aluminum. The RM wheel was rotated slowly (20 sec/rev) using a stepper motor to compensate for the frame rate of the BIS (120 ms). Dose rate functions (DRFs) over two RM wheel rotations were acquired. Calibration was made with known thicknesses of homogeneous solid water. For each pixel the time width, skewness and kurtosis of the DRFs were computed. The time width was used to compute the object WEPL. In the heterogeneous phantom, the excess skewness and excess kurtosis (i.e. difference from homogeneous cases) were computed and assessed for suitability for patient set up. Results: The technique allowed for the simultaneous production of images that can be used for WEPL verification, showing few internal details, and excess skewness and kurtosis images that can be used for soft tissue alignment. These latter images highlight areas where range mixing has occurred, correlating with phantom heterogeneities. Conclusion: The excess skewness and kurtosis images contain details that are not visible in the WET images. These images, unique to the time-resolved proton radiographic method, could be used for patient set up according to soft tissues.

60 APPLIED LIFE SCIENCES↗

Alignment of low-dose X-ray fluorescence tomography images using differential phase contrast

X-ray fluorescence nanotomography provides unprecedented sensitivity for studies of trace metal distributions in whole biological cells. Dose fractionation, in which one acquires very low dose individual projections and then obtains high statistics reconstructions as signal from a voxel is brought together (Hegerl & Hoppe, 1976), requires accurate alignment of these individual projections so as to correct for rotation stage runout. It is shown here that differential phase contrast at 10.2 keV beam energy offers the potential for accurate cross-correlation alignment of successive projections, by demonstrating that successive low dose, 3 ms per pixel, images acquired at the same specimen position and rotation angle have a narrower and smoother cross-correlation function (1.5 pixels FWHM at 300 nm pixel size) than that obtained from zinc fluorescence images (25 pixels FWHM). The differential phase contrast alignment resolution is thus well below the 700 nm × 500 nm beam spot size used in this demonstration, so that dose fractionation should be possible for reduced-dose, more rapidly acquired, fluorescence nanotomography experiments.

differential phase contrast↗

Magnetic domain observation of FeCo thin films fabricated by alternate monoatomic layer deposition

FeCo thin films are fabricated by alternate monoatomic layer deposition method on a Cu{sub 3}Au buffer layer, which in-plane lattice constant is very close to the predicted value to obtain a large magnetic anisotropy constant. The variation of the in-plane lattice constant during the deposition process is investigated by reflection high-energy electron diffraction. The magnetic domain images are also observed by a photoelectron emission microscope in order to microscopically understand the magnetic structure. As a result, element-specific magnetic domain images show that Fe and Co magnetic moments align parallel. A series of images obtained with various azimuth reveal that the FeCo thin films show fourfold in-plane magnetic anisotropy along 〈110〉 direction, and that the magnetic domain structure is composed only of 90∘ wall.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tomosaic : efficient acquisition and reconstruction of teravoxel tomography data using limited-size synchrotron X-ray beams

X-rays offer high penetration with the potential for tomography of centimetre-sized specimens, but synchrotron beamlines often provide illumination that is only millimetres wide. Here an approach is demonstrated termed Tomosaic for tomographic imaging of large samples that extend beyond the illumination field of view of an X-ray imaging system. This includes software modules for image stitching and calibration, while making use of existing modules available in other packages for alignment and reconstruction. The approach is compatible with conventional beamline hardware, while providing a dose-efficient method of data acquisition. By using parallelization on a distributed computing system, it provides a solution for handling teravoxel-sized or larger datasets that cannot be processed on a single workstation in a reasonable time. Using experimental data, the package is shown to provide good quality three-dimensional reconstruction for centimetre-sized samples with sub-micrometre pixel size.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interactive initialization of 2D/3D rigid registration

Purpose: Registration is one of the key technical components in an image-guided navigation system. A large number of 2D/3D registration algorithms have been previously proposed, but have not been able to transition into clinical practice. The authors identify the primary reason for the lack of adoption with the prerequisite for a sufficiently accurate initial transformation, mean target registration error of about 10 mm or less. In this paper, the authors present two interactive initialization approaches that provide the desired accuracy for x-ray/MR and x-ray/CT registration in the operating room setting. Methods: The authors have developed two interactive registration methods based on visual alignment of a preoperative image, MR, or CT to intraoperative x-rays. In the first approach, the operator uses a gesture based interface to align a volume rendering of the preoperative image to multiple x-rays. The second approach uses a tracked tool available as part of a navigation system. Preoperatively, a virtual replica of the tool is positioned next to the anatomical structures visible in the volumetric data. Intraoperatively, the physical tool is positioned in a similar manner and subsequently used to align a volume rendering to the x-ray images using an augmented reality (AR) approach. Both methods were assessed using three publicly available reference data sets for 2D/3D registration evaluation. Results: In the authors' experiments, the authors show that for x-ray/MR registration, the gesture based method resulted in a mean target registration error (mTRE) of 9.3 ± 5.0 mm with an average interaction time of 146.3 ± 73.0 s, and the AR-based method had mTREs of 7.2 ± 3.2 mm with interaction times of 44 ± 32 s. For x-ray/CT registration, the gesture based method resulted in a mTRE of 7.4 ± 5.0 mm with an average interaction time of 132.1 ± 66.4 s, and the AR-based method had mTREs of 8.3 ± 5.0 mm with interaction times of 58 ± 52 s. Conclusions: Based on the authors' evaluation, the authors conclude that the registration approaches are sufficiently accurate for initializing 2D/3D registration in the OR setting, both when a tracking system is not in use (gesture based approach), and when a tracking system is already in use (AR based approach)

62 RADIOLOGY AND NUCLEAR MEDICINE↗