Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Phase control with two-beam interferometry method in a terahertz dielectric wakefield accelerator

High-gradient, beam-driven wakefield acceleration in THz structures is a promising technology for future free electron lasers and colliders. In this scheme, the main beam is accelerated by the wakefield of the high current drive beam. The time separation between the main and drive beams has to be chosen carefully to ensure that the main beam is in an accelerating phase of the drive's wakefield. THz accelerating structures provide high gradient acceleration due to their small apertures, but their phase control is difficult due to the picosecond-scale period. Here, we report on a wakefield acceleration experiment in a 460 GHz dielectric wakefield accelerator (DWA). The optimum phase of the main beam during the experiment is determined with a two-beam wakefield interferometry (TBI) measurement. This is performed without the measurement of the main and drive beam bunch lengths or their separation. In TBI, the interference of the wakefields produced by the drive and main beams is measured with an integrating THz detector. The TBI signal, as a function of separation between the drive and main beams, exhibits a minimum due to destructive interference of these wakefields, which corresponds to maximum acceleration of the main beam as is confirmed by the energy spectrometer measurement. The maximum energy gain of 0.8 MeV and maximum energy loss of 1.2 MeV for the main beam have been measured, which agrees well with theoretical predictions. Published by AIP Publishing.

43 PARTICLE ACCELERATORS↗

Compression Stockings May Ameliorate Orthostatic Intolerance in Astronauts After Short-Duration Space Flight

Orthostatic intolerance following spaceflight has been observed since the early days of manned spaceflight, and no countermeasure has been 100% effective. During re-entry NASA astronauts currently wear an inflatable anti-gravity suit (AGS) which compresses the legs and abdomen, but this device is uncomfortable and loses effectiveness upon egress from the Space Shuttle. We previously reported that foot-to-thigh, gradient compression stockings were comfortable and effective during standing after Shuttle missions. More recently we showed in a ground-based model of spaceflight that the addition of splanchnic compression to the foot-to-thigh compression stockings, creating foot-to-breast high compression, improved orthostatic tolerance in hypovolemic subjects to a level similar to the AGS. Purpose: To evaluate a new three-piece, foot-to-breast high gradient compression garment as a countermeasure to post-spaceflight orthostatic intolerance. Methods: Fourteen astronauts completed this experiment (7 control, 7 treatment) following Space Shuttle missions lasting 12-16 days. Treatment subjects were custom-fitted for a three-piece, foot-to-breast high compression garment consisting of shorts and foot-to-thigh stockings. The garments were constructed to provide 55 mmHg compression at the ankle and decreased gradually to 15 mmHg over the abdomen. Orthostatic testing occurred ~30 days before flight (without garments) and ~2 hours after flight (with garments for treatment group only) on landing day. Blood pressure (BP) and heart rate (HR) were acquired for 2 minutes while the subject lay prone and then for 3.5 minutes after the subject stood. Data are reported as mean +/- SE. Results: The compression garment successfully prevented the tachycardia and hypotension typically seen post-spaceflight. On landing day, treatment subjects had a smaller change in HR (11+/-1 vs. 21+/-4 beats/min, p< or =0.05) and no decrease in systolic BP (2+/-4 vs. -9+/-2 mmHg, p< or =0.05). Garments also received good comfort ratings and were relatively easy to don. Conclusion: In this small group of astronauts, foot-to-breast high gradient compression garments seem to have prevented these negative effects of spaceflight on the cardiovascular responses to standing.

Platts, Steven H.↗

High-order gradients with the shifted boundary method: An embedded enriched mixed formulation for elliptic PDEs

Here, we propose an extension of the embedded boundary method known as “shifted boundary method” to elliptic diffusion equations in mixed form (e.g., Darcy flow, heat diffusion problems with rough coefficients, etc.). Our aim is to obtain an improved formulation that, for linear finite elements, is at least second-order accurate for both flux and primary variable, when either Dirichlet or Neumann boundary conditions are applied. Following previous work of Nishikawa and Mazaheri in the context of residual distribution methods, we consider the mixed form of the diffusion equation (i.e., with Darcy-type operators), and introduce an enrichment of the primary variable. This enrichment is obtained exploiting the relation between the primary variable and the flux variable, which is explicitly available at nodes in the mixed formulation. The proposed enrichment mimics a formally quadratic pressure approximation, although only nodal unknowns are stored, similar to a linear finite element approximation. We consider both continuous and discontinuous finite element approximations and present two approaches: a non-symmetric enrichment, which, as in the original references, only improves the consistency of the overall method; and a symmetric enrichment, which enables a full error analysis in the classical finite element context. Combined with the shifted boundary method, these two approaches are extended to high-order embedded computations, and enable the approximation of both primary and flux (gradient) variables with second-order accuracy, independently on the type of boundary conditions applied. We also show that the primary variable is third-order accurate, when pure Dirichlet boundary conditions are embedded.

97 MATHEMATICS AND COMPUTING↗

Apparatus and process for passivating an SRF cavity

An apparatus and process for the production of a niobium cavity exhibiting high quality factors at high gradients is provided. The apparatus comprises a first chamber positioned within a second chamber, an RF generator and vacuum pumping systems. The process comprises placing the niobium cavity in a first chamber of the apparatus; thermally treating the cavity by high temperature in the first chamber while maintaining high vacuum in the first and second chambers; and applying a passivating thin film layer to a surface of the cavity in the presence of a gaseous mixture and an RF field. Further a niobium cavity exhibiting high quality factors at high gradients produced by the method of the invention is provided.

36 MATERIALS SCIENCE↗

Final Report: Development of a CW NCRF Photoinjector using Solid Freeform Fabrication

The development of very high duty cycle, high gradient photoinjectors is critical for the next generation of accelerator systems, such as X-ray free-electron lasers (FELs), inverse Compton scattering (ICS) sources, energy recovery linacs (ERLs), injectors for linear colliders, as well as a variety of industrial systems for homeland security applications. NCRF photoinjectors have a proven track record at generating the high-quality beams necessary for these applications, however they are limited in large part to relatively low duty cycles due to ohmic wall looses. Thus a key issue for high average power, normal conducting, photoinjectors is effective structure cooling [9]. The fabrication of current high average-power photoinjectors relies on conventional design and fabrication techniques with many limitations. Advances in Solid Freeform Fabrication (SFF) technology may make it possible to design and produce near net-shape copper structures for the next generation of very high rep rate, high gradient radio frequency (RF) photoinjectors. RF and thermal-management optimized geometries could be fully realized without the usual constraints and compromises of conventional machining techniques*. Further advances in SFF and powder metallurgy (P/M) techniques, with the ability to fine tune material properties, may soon make it possible to produce monolithic, thermally robust RF structures faster and cheaper than ever before.

Frigola, Pedro↗

The science case for an intermediate energy advanced and novel accelerator linear collider facility

It is widely accepted that the next lepton collider beyond a Higgs factory would require center-of-mass energy of the order of up to 15 TeV. Since, given reasonable space and cost restrictions, conventional accelerator technology reaches its limits near this energy, high-gradient advanced acceleration concepts are attractive. Advanced and novel accelerators (ANAs) are leading candidates due to their ability to produce acceleration gradients on the order of 1–100 GV/m, leading to compact acceleration facilities. However, intermediate energy facilities (IEF) are required to test the critical technology elements on the way towards multi-TeV-class colliders. Here a science case for a 20–100 GeV center-of-mass energy ANA-based lepton collider that can be a candidate for an intermediate energy facility is presented. The IEF can provide numerous opportunities for high energy physics studies including precision Quantum Chromodynamics and Beyond the Standard Model physics measurements, investigation of charged particle interactions with extreme electromagnetic fields, and exploring muon and proton beam acceleration. Possible applications of this collider include the studies of γγ and electron beam-fixed target/beamdump collider designs. Thus, the goal of the proposed IEF is to both carry out particle physics measurements in the 20-100 GeV ranges as well as to serve as an ANA demonstrator facility.

43 PARTICLE ACCELERATORS↗

In vivo dosimetry in brachytherapy

In vivo dosimetry (IVD) has been used in brachytherapy (BT) for decades with a number of different detectors and measurement technologies. However, IVD in BT has been subject to certain difficulties and complexities, in particular due to challenges of the high-gradient BT dose distribution and the large range of dose and dose rate. Due to these challenges, the sensitivity and specificity toward error detection has been limited, and IVD has mainly been restricted to detection of gross errors. Given these factors, routine use of IVD is currently limited in many departments. Although the impact of potential errors may be detrimental since treatments are typically administered in large fractions and with high-gradient-dose-distributions, BT is usually delivered without independent verification of the treatment delivery. This Vision 20/20 paper encourages improvements within BT safety by developments of IVD into an effective method of independent treatment verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

A vectorized, finite-volume, adaptive-grid algorithm for Navier-Stokes calculations

An adaptive grid, finite-volume method has been used to solve the Navier-Stokes equations for complete (forebody and afterbody) flowfields around blunt bodies. The code, which is applicable for axisymmetric or two-dimensional flows, allows the mesh to adjust during the computation to provide a closer spacing of mesh points in regions of high gradients, thus minimizing the number of required computational points. The solution technique is explicit, utilizing a maximum time-step advancement at each grid point to accelerate convergence to the steady state. The code has been fully vectorized for efficient solution on the CYBER 203 computer. A very flexible rezoning routine is used to concentrate mesh points anywhere in the field, either by a user-defined weighting function or by allowing high gradient regions to adjust the grid. The grid adjustment routine is implicit in nature and represents a very small portion of the total computational cost. Currently, the code runs in approximately 0.000016 seconds per grid point per iteration.

Gnoffo, P. A.↗

Linac cryogenic distribution system maintenance and upgrades at JLab

The Central Helium Liquefier (CHL) distribution system to the CEBAF and FEL linacs at Jefferson Lab (JLab) experienced a planned warm up during the late summer and fall of 2012 for the first time after its commissioning in 1991. Various maintenance and modifications were performed to support high beam availability to the experimental users, meet 10 CFR 851 requirements for pressure systems, address operational issues, and prepare the cryogenic interfaces for the high-gradient cryomodules needed for the 12 GeV upgrade. Cryogenic maintenance and installation work had to be coordinated with other activities in the linacs and compete for manpower from other department installation activities. With less than a quarter of the gas storage capacity available to handle the boil-off from the more than 40 cryomodules, 35,000 Nm{sup 3} of helium was re-liquefied and shipped to a vendor via a liquid tanker trailer. Nearly 200 u-tubes had to be removed and stored while seals were replaced on related equipment such as vacuum pump outs, bayonet isolation and process valves.

42 ENGINEERING↗

Prevention of Dual-Mode Excitation in 9-Cell Cavities for LCLSII-HE

Dual-Mode Excitation, also referred to as mode-mixing, is a superposition of two fundamental pi modes in an SRF cavity. In 9-cell TESLA cavities used for the LCLSII-HE project, the two modes that are commonly excited are the pi mode (1300.2 MHz), and the 7/9 pi mode (1297.8 MHz). During vertical cavity qualification testing, only the pi mode is driven by the RF system. However, at high gradients, emitted power at the frequency of the 7/9 pi mode grows despite the RF system only powering the pi mode. When this happens, the RF power measurement system is unable to differentiate between the superimposed modes, and any data taken is invalid. The previous method of dealing with mode-mixing was to turn off power to the cavity, let both modes decay fully, then restore power. Because of the time-sensitive nature of this testing, this leads to underestimates of Q0 or any radiant field emission present in the cavity. The novel RF control solution prevents the 7/9 pi mode from being excited while not interfering with measurements of the fundamental pi mode. A second RF control system is connected to the cavity which drives the 7/9 pi mode. The loop phase for driving the 7/9 pi mode in self excited loop mode is determined then shifted by 180 degrees, thus providing a negative feedback to the undesired mode. Because this off-resonance power can be very small, on the order of milliwatts, it does not interfere with the high-power measurements of the fundamental pi mode. At Jefferson Lab, we are now able to test a cavity for the LCLSII-HE project with no problems from mode-mixing, which allows for CW processing of high-gradient multipacting and field emission.

Owen, Peter↗

Pulse Length Monitor for Breakdown Diagnostics in THz and Mm-Wave Accelerators

The development of novel high-gradient accelerating structures operating at THz frequencies is critical for future free-electron lasers and TeV scale linear colliders. To reach high energies with reasonable length requires high accelerating gradients of ~100 MV/m. The main limitation to reaching these high-energy gradients is the vacuum RF breakdown phenomenon, which disrupts normal accelerator operations. For stable operations and to understand the breakdown microscopic dynamics, a new device capable of detecting the breakdown occurrences is required. In this paper, we provide the design of a pulse length monitor based on an analog to digital converter for fast signal digitization without the need to use high-speed digitizers to be used in a commercial mm-wave heterodyne spectrometer.

43 PARTICLE ACCELERATORS↗

Generation of meter-scale hydrogen plasmas and efficient, pump-depletion-limited wakefield excitation using 10 GeV electron bunches

High repetition rates and efficient energy transfer to the accelerating beam are important for a future linear collider based on the beam-driven plasma wakefield acceleration scheme (PWFA-LC). This paper reports the first results from the Plasma Wakefield Acceleration Collaboration (E300) that are beginning to address both of these issues using the recently commissioned FACET-II facility at SLAC national accelerator laboratory. Here we have generated meter-scale hydrogen plasmas using time-structured 10 GeV electron bunches from FACET-II, which hold the promise of dramatically increasing the repetition rate of PWFA by rapidly replenishing the gas between each shot compared to the hitherto used lithium plasmas that operate at 1–10 Hz. Furthermore, we have excited wakes in such plasmas that are suitable for high gradient particle acceleration with high drive-bunch to wake energy transfer efficiency- a first step in achieving a high overall energy transfer efficiency. We have done this by using time-structured electron drive bunches that typically have one or more ultra-high current (> 30 kA) femtosecond spike(s) superimposed on a longer (~0.4 ps) lower current (< 10 kA) bunch structure. The first spike effectively field-ionizes the gas and produces a meter-scale (30–160 cm) plasma, whereas the subsequent beam charge creates a wake. The length and amplitude of the wake depends on the longitudinal current profile of the bunch and plasma density. We find that the onset of pump depletion, when some of the drive beam electrons are nearly fully depleted of their energy, occurs for hydrogen pressure ≥ 1.5Torr. We also show that some electrons in the rear of the bunch can gain several GeV energies from the wake. These results are reproduced by particle-in-cell simulations using the QPAD code. At a pressure of ~2Torr, simulation results and experimental data show that the beam transfers about 60% of its energy to the wake.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microstructure development in a cold worked SRF Nb sheet undergoing 700°C-900°C/3h heat treatments.

Bulk Nb for TESLA shaped SRF cavities is a mature technology, with high gradient (>35 MV/m) and high Q cavities (>1010, ~2K) routinely fabricated. Significant advances are in order to push Q?s to 1011 (~2K), and involve modifications to the sub-surface Nb layers by impurity doping (N, O). In order to achieve the lowest surface resistance any trapped flux needs to be expelled for cavities to reach high Q?s. There is clear evidence that cavities fabricated from polycrystalline sheets meeting current specifications require higher temperatures beyond 800oC leads to better flux expulsion, and hence improves Q. Recently, cavities fabricated with a non-traditional Nb sheet with initial cold work due to cold rolling expelled flux better after 800°C/3h heat treatment than cavities fabricated using fine-grain polycrystalline Nb sheets. Here, we analyze the microstructure development in Nb from the vendor supplied cold work non-annealed sheet that was fabricated into an SRF cavity as a function of heat treatment building upon the methodology development to analyze microstructure being developed by the FSU-MSU-UT-Austin- JLAB collaboration. The results indicate correlation between full recrystallization and better flux expulsion.

Balachandran, S.↗