Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high frequency testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Sensitive visual test for concave diffraction gratings.

A simple visual test for the evaluation of concave diffraction gratings is described. It is twice as sensitive as the Foucault knife edge test, from which it is derived, and has the advantage that the images are straight and free of astigmatism. It is particularly useful for grating with high ruling frequency where the above image faults limit the utility of the Foucault test. The test can be interpreted quantitatively and can detect zonal grating space errors of as little as 0.1 A.

Bruner, E. C., Jr.↗

The efficiency of photovoltaic cells exposed to pulsed laser light

Future space missions may use laser power beaming systems with a free electron laser (FEL) to transmit light to a photovoltaic array receiver. To investigate the efficiency of solar cells with pulsed laser light, several types of GaAs, Si, CuInSe2, and GaSb cells were tested with the simulated pulse format of the induction and radio frequency (RF) FEL. The induction pulse format was simulated with an 800-watt average power copper vapor laser and the RF format with a frequency-doubled mode-locked Nd:YAG laser. Averaged current vs bias voltage measurements for each cell were taken at various optical power levels and the efficiency measured at the maximum power point. Experimental results show that the conversion efficiency for the cells tested is highly dependent on cell minority carrier lifetime, the width and frequency of the pulses, load impedance, and the average incident power. Three main effects were found to decrease the efficiency of solar cells exposed to simulated FEL illumination: cell series resistance, LC 'ringing', and output inductance. Improvements in efficiency were achieved by modifying the frequency response of the cell to match the spectral energy content of the laser pulse with external passive components.

Lowe, R. A.↗

Vibrational processing of a dynamic structural flight system: A multichannel spectral estimation approach

Dynamic testing of large flight vehicles (rockets) is not only complex, but also can be very costly. These flights are infrequent and can lead to disastrous effects if something were to fail during the flight. The development of sensors coupled to internal components offers a great challenge in reducing their size, yet still maintaining their precision. Sounding rockets provide both a viable and convenient alternative to the more costly vehicular flights. Some of the major objectives are to test various types of sensors for monitoring components of high interest as well as investigating real-time processing techniques. Signal processing presents an extreme challenge in this noisy multichannel environment. The estimation and tracking of modal frequencies from vibrating structures is an important set of features that can provide information about the components under test; therefore, high resolution multichannel spectral processing is required. Finally, the application of both single channel and multichannel techniques capable of producing reliable modal frequency estimates of a vibrating structure from uncertain accelerometer measurements is discussed.

42 ENGINEERING↗

Fabrication and Performance of Planar Schottky Diodes with T-gate-like Anodes in 200 GHz Subharmonically-Pumped Waveguide Mixers

A T-gate-like structure has been developed, fabricated and tested as the anode for millimeter and submillimeter-wave Schottky diodes. The low parasitics of the T-anode diodes yield extremely high cutoff frequencies, making the diodes useable at frequencies well beyond 1 THz. The diodes were tested as an antiparallel-pair, integrated monolithically with microstrip circuitry on a quartz substrate, in a subharmonically pumped waveguide mixer. A double sideband noise temperature of 600 K with a conversion loss of 4.7 dB were measured at 200 GHz. This is believed to be the lowest noise temperature ever reported for a room temperature subharmonically-pumped Schottky diode mixer at this frequency.

Planar↗

Experimental Performance Evaluation of a High Speed Permanent Magnet Synchronous Motor and Drive for a Flywheel Application at Different Frequencies

This paper presents the results of an experimental performance characterization study of a high speed, permanent magnet motor/generator (M/G) and drive applied to a flywheel module. Unlike the conventional electric machine the flywheel M/G is not a separated unit; its stator and rotor are integrated into a flywheel assembly. The M/G rotor is mounted on a flywheel rotor, which is magnetically levitated and sealed within a vacuum chamber during the operation. Thus, it is not possible to test the M/G using direct load measurements with a dynamometer and torque transducer. Accordingly, a new in-situ testing method had to be developed. The paper describes a new flywheel M/G and drive performance evaluation technique, which allows the estimation of the losses, efficiency and power quality of the flywheel high speed permanent magnet M/G, while working in vacuum, over wide frequency and torque ranges. This method does not require any hardware modification nor any special addition to the test rig. This new measurement technique is useful for high-speed applications, when applying an external load is technically difficult.

Nagorny, Aleksandr S.↗

Combined high vacuum/high frequency fatigue tester

Apparatus permits application of significantly greater number of cycles or equivalent number of cycles in shorter time than conventional fatigue test machines. Environment eliminates problems associated with high temperature oxidation and with sensitivity of refractory alloy behavior to atmospheric contamination.

Honeycutt, C. R.↗

Identifying Differential Equations in Fourier Domain (FourierIdent)

We investigate identifying differential equations in the frequency domain. Fourier analysis is an important tool in theoretical analysis and numerical solvers of differential equations, yet there is limited work in exploring this connection in the identification of differential equations. This paper aims to identify the underlying differential equation in the frequency domain, from a given single realization of the differential equation perturbed by noise. Such setting imposes difficulties which are different from other identification methods where computation is carried out in the physical domain. We propose several ways to mitigate the challenges arising from noise in data and large differences in the magnitudes of frequency responses. The main takeaways are that identifying differential equations solely in the frequency domain is challenging, the method we propose is based on a form of domain partitions in the frequency domain, and this method shows benefits for complex data even with high level of noise. We introduce a Fourier feature denoising, and define the meaningful data region and the core regions of features to reduce the effect of noise in the frequency domain and to enhance the accuracy in coefficient identification. The proposed method is tested on various differential equations with linear, nonlinear, and high-order derivative feature terms, and shows advantages on complex data with many frequency modes, even under high level of noise.

97 MATHEMATICS AND COMPUTING↗

High Resolution Data Analysis: Plans and Prospects [Book Chapter]

Herein, a report on the progress on the high resolution data analysis of the ADMX experimental results is presented. In this paper, tools are developed and tested on a blind injection mimicking a Maxwellian like signal in the frequency domain. This blind injection will be used as a test bed which can be later implemented on all the high resolution data. The high resolution data is stored in the Fermilab server. In this analysis a PostgreSQL query was made to ensure the blind injection is in the middle of the frequency spectrum and 19 such files were found. The time series data is read using a c++ program. An apodization function is applied on the time series data and zero filled to reduce the frequency spacing in order to achieve a better interpolation. A FFTW header is used to compute the Fourier transform of the time series data. A Savitzky–Golay filter is applied on the unnormalized power which then can be used to remove the spectral shape. Each frequency spectrum has a bandwidth of 50 kHz.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wind-tunnel fan noise reduction including effects of turning vanes on noise propagation

Fan silencers with low-pressure drop have been designed and installed in the NASA Ames 7- by 10-Foot Wind Tunnel No. 1. The silencers are composed of an absorbent lining flush with the wind-tunnel walls upstream of the fan and an absorbent splitter in the duct downstream of the fan. An acoustical insertion loss of 4 to 12 dB was measured between 100 and 1000 Hz. High-frequency performance of the silencers was reduced by test-section noise and by corner vanes which turned the sound waves so they followed the duct axis. Sound below 1.2 kHz diffracted around the 305-mm-long vanes and impinged on acoustically absorbent corner walls. Wind-tunnel flow losses are discussed.

Soderman, P. T.↗

The ACTS Flight System - Cost-Effective Advanced Communications Technology

The multibeam communications package (MCP) for the Advanced Communications Technology Satellite (ACTS) to be STS-launched by NASA in 1988 for experimental demonstration of satellite-switched TDMA (at 220 Mbit/sec) and baseband-processor signal routing (at 110 or 27.5 Mbit/sec) is characterized. The developmental history of the ACTS, the program definition, and the spacecraft-bus and MCP parameters are reviewed and illustrated with drawings, block diagrams, and maps of the coverage plan. Advanced features of the MPC include 4.5-dB-noise-figure 30-GHz FET amplifiers and 20-GHz TWTA transmitters which provide either 40-W or 8-W RF output, depending on rain conditions. The technologies being tested in ACTS can give frequency-reuse factors as high as 20, thus greatly expanding the orbit/spectrum resources available for U.S. communications use.

Holmes, W. M., Jr.↗

Structural response of a rotating bladed disk to rotor whirl

A set of high speed rotating whirl experiments were performed in the vacuum of the MIT Blowdown Compressor Facility on the MIT Aeroelastic Rotor, which is structurally typical of a modern high bypass ratio turbofan stage. These tests identified the natural frequencies of whirl of the rotor system by forcing its response using an electromagnetic shaker whirl excitation system. The excitation was slowly swept in frequency at constant amplitude for several constant rotor speeds in both a forward and backward whirl direction. The natural frequencies of whirl determined by these experiments were compared to those predicted by an analytical 6 DOF model of a flexible blade-rigid disk-flexible shaft rotor. The model is also presented in terms of nondimensional parameters in order to assess the importance of the interation between the bladed disk dynamics and the shaft-disk dynamics. The correlation between the experimental and predicted natural frequencies is reasonable, given the uncertainty involved in determining the stiffness parameters of the system.

Crawley, E. F.↗

Analysis and measurement of electromagnetic scattering by pyramidal and wedge absorbers

By modifying the reflection coefficients in the Uniform Geometrical Theory of Diffraction a solution that approximates the scattering from a dielectric wedge is found. This solution agrees closely with the exact solution of Rawlins which is only valid for a few minor cases. This modification is then applied to the corner diffraction coefficient and combined with an equivalent current and geometrical optics solutions to model scattering from pyramid and wedge absorbers. Measured results from 12 inch pyramid absorbers from 2 to 18 GHz are compared to calculations assuming the returns add incoherently and assuming the returns add coherently. The measured results tend to be between the two curves. Measured results from the 8 inch wedge absorber are also compared to calculations with the return being dominated by the wedge diffraction. The procedures for measuring and specifying absorber performance are discussed and calibration equations are derived to calculate a reflection coefficient or a reflectivity using a reference sphere. Shaping changes to the present absorber designs are introduced to improve performance based on both high and low frequency analysis. Some prototypes were built and tested.

Dewitt, B. T.↗

Sequentially evaporated thin film YBa2Cu3O(7-x) superconducting microwave ring resonator

There is great interest in the application of thin film high temperature superconductors in high frequency electronic circuits. A ring resonator provides a good test vehicle for assessing the microwave losses in the superconductor and for comparing films made by different techniques. Ring resonators made of YBa2Cu3O(7-x) have been investigated on LaAlO3 substrates. The superconducting thin films were deposited by sequential electron beam evaporation of Cu, Y, and BaF2 with a post anneal. Patterning of the superconducting film was done using negative photolithography. A ring resonator was also fabricated from a thin gold film as a control. Both resonators had a gold ground plane on the backside of the substrate. The ring resonators' reflection coefficients were measured as a function of frequency from 33 to 37 GHz at temperatures ranging from 20 K to 68 K. The resonator exhibited two resonances which were at 34.5 and 35.7 GHz at 68 K. The resonant frequencies increased with decreasing temperature. The magnitude of the reflection coefficients was in the calculation of the unloaded Q-values. The performance of the evaporated and gold resonator are compared with the performance of a laser ablated YBa2Cu3O(7-x) resonator. The causes of the double resonance are discussed.

Rohrer, Norman J.↗

Harmonic drive gear error: Characterization and compensation for precision pointing and tracking

Imperfections and geometry effects in harmonic drive gear reducers cause a cyclic gear error, which at a systems level, results in high frequency torque fluctuations. To address this problem, gear error testing was performed on a wide variety of sizes and types of harmonic drives. It was found that although all harmonic drives exhibit a significant first harmonic, higher harmonics varied greatly with each unit. From life tests, small changes were found in harmonic content, phase shift, and error magnitude (on the order of .008 deg peak-to-peak maximum) occurred for drives with many millions of degrees of output travel. Temperature variations also influenced gear error. Over a spread of approximately 56 C (100 F), the error varied in magnitude approximately 20 percent but changes in a repeatable and predictable manner. Concentricity and parallelness tests of harmonic drive parts resulted in showing alignment influence gear error amplitude. Tests on dedoidaled harmonic drives showed little effect on gear error; surprisingly, in one case for a small drive, gear error actually improved. Electronic compensation of gear error in harmonic drives was shown to be substantially effective for units that are first harmonic dominant.

Nye, Ted W.↗

A 1- to 10-GHz downconverter for high-resolution microwave survey

A downconverter was designed, built, and tested for the High Resolution Microwave Survey project. The input frequency range is 1 to 10 GHz with instantaneous bandwidth of 350 MHz and dynamic range of 125 dB/Hz. Requirements were derived for the local oscillators and special design techniques were implemented to achieve the high degree of spectral purity required.

Mcwatters, D.↗

Acoustic Treatment Design Scaling Methods: Analytical and Experimental Data Correlation - Volume 5

The primary purpose of the study presented in this volume is to present the results and data analysis of in-duct transmission loss measurements. Transmission loss testing was performed on full-scale, 1/2-scale, and 115-scale treatment panel samples. The objective of the study was to compare predicted and measured transmission loss for full-scale and subscale panels in an attempt to evaluate the variations in suppression between full- and subscale panels which were ostensibly of equivalent design. Generally, the results indicated an unsatisfactory agreement between measurement and prediction, even for full-scale. This was attributable to difficulties encountered in obtaining sufficiently accurate test results, even with extraordinary care in calibrating the instrumentation and performing the test. Test difficulties precluded the ability to make measurements at frequencies high enough to be representative of subscale liners. It is concluded that transmission loss measurements without ducts and data acquisition facilities specifically designed to operate with the precision and complexity required for high subscale frequency ranges are inadequate for evaluation of subscale treatment effects.

Chien, W. E.↗

Blade Surface Pressure Distributions in a Rocket Engine Turbine: Experimental Work With On-Blade Pressure Transducers

Understanding the unsteady aspects of turbine rotor flowfields is critical to successful future turbine designs. A technology program was conducted at NASA's Marshall Space Flight Center to increase the understanding of unsteady environments for rocket engine turbines. The experimental program involved instrumenting turbine rotor blades with surface-mounted high frequency response pressure transducers. The turbine model was then tested to measure the unsteady pressures on the rotor blades. The data obtained from the experimental program is unique in three respects. First, much more unsteady data was obtained (several minutes per set point) than has been possible in the past. Also, two independent unsteady data acquisition systems and fundamental signal processing approaches were used. Finally, an extensive steady performance database existed for the turbine model. This allowed an evaluation of the effect of the on-blade instrumentation on the turbine's performance. This unique data set, the lessons learned for acquiring this type of data, and the improvements made to the data analysis and prediction tools will contribute to future turbine programs such as those for reusable launch vehicles.

Hudson, Susan T.↗