Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high field sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗

Increasing the Stability of Deep Blue Phosphor‐Sensitized OLEDs Using the Polariton‐Enhanced Purcell Effect

Abstract The stability of efficient, deep blue organic light‐emitting diodes (OLEDs) remains a major challenge in the field of organic electronics. Poor device stability originates from the high probability for destructive non‐radiative triplet exciton annihilation events. Phosphor‐sensitized fluorescence (PSF) is proposed to achieve an efficient, deep blue color by energy transfer from phosphors to fluorophores. Recently, the polariton‐enhanced Purcell (PEP) effect is introduced to decrease the triplet radiative lifetime and density, resulting in an increase in blue phosphorescent OLED lifetime. Here, the PEP effect is introduced to enhance the stability of the PSF‐OLEDs. It is shown that the PEP effect increases all radiative decay rates of the phosphors and fluorophores, leading to a reduction in the triplet annihilation events. Using a Pt‐complex phosphor sensitizer and a so‐called multi‐resonance fluorescent emitter in a PEP cavity, a 3.1‐fold lifetime increase is observed at a current density ofJ= 10 mA cm −2 , reduced EQE roll‐off and deep blue color with Commission Internationale de l'Eclairage coordinates of (0.13, 0.09). The PEP effect maximally extends PSF‐OLED lifetimes in devices with the highest triplet‐to‐singlet energy transfer rates. Moreover, this work suggests that the benefits of PEPs apply to all triplet‐based OLEDs.

Chemistry↗

In-Flight Performance of the Polarization Modulator in the CLASP Rocket Experiment

We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman‐alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman‐alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non‐uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.

CLASP↗

Assessment of the associated particle technique with high-resolution gamma-ray spectroscopy for in-field identification of chemical warfare agents and explosives

In this work, high-resolution prompt γ-ray neutron activation analysis (PGNAA) is performed using the associated particle (AP) technique with a deuterium-tritium neutron generator and high-purity germanium detector. Although the time resolution is inferior compared to similar systems employing fast scintillation γ-ray detectors, the strong background suppression combined with the high γ-ray energy resolution provides an important boost in sensitivity to certain key elements, especially relevant to field measurements of complex chemicals encased within thick layers of metal, such as in the case of recovered chemical warfare (CW) munitions. Results for various CW and explosive simulants contained within mock munitions are presented and compared with results obtained from traditional PGNAA measurements without the aid of the AP technique. Significant improvements in identification and discrimination between certain chemicals are achieved with the high energy resolution AP technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCZ: Striations in CZ silicon crystals grown under various axial magnetic field strengths

Suppression of fluid flow instabilities in the melt by the axial magnetic field in Czochralski silicon crystal growth (AMCZ) is investigated precisely by a high-sensitivity striation etching in conjunction with temperature measurements. The magnetic strength (B) was varied up to 4.0 kG, incremented in 0.5 kG/5 cm crystal length. The convection flow was substantially suppressed at B 1.0 kG. A low oxygen level of 2-3 ppma and a high resistivity of 400 ohm-cm is achieved in the AMCZ silicon crystals at B 1.0 kG. Details of the striation formation as a function of B are presented. Computer simulation of the magnetohydrodynamics of the AMCZ silicon crystal growth are discussed briefly with regard to the solute, especially oxygen segregation at B=0, 1.0, and 2.0 kG. Earlier studies in the inverted Bridgman growth of InSb and Ge, which have established the cause and effect relationship between the convection in the melt and the striation formation as well as the suppression of the convections in the melt by transverse magnetic field are reviewed.

Kim, G. K. M.↗

Improving operational performance using machine learning analysis of Radiation Portal Monitor measurements

Radiation Portal Monitors (RPMs) have been installed worldwide to scan vehicles and cargo for the presence of radiological and nuclear materials. In field operations, the sensitivity of these systems is typically limited by the relatively high rates of nuisance alarms that usually must be followed up with secondary inspections. We have developed a machine-learning based alarm analysis system that has been deployed at numerous locations in the U.S. and internationally. Our Enhanced Radiological Nuclear Inspection and Evaluation (ERNIE) analysis software and its derivatives have demonstrated increased sensitivity to radiological and nuclear material of concern while reducing nuisance alarms by as much as an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An airborne short wave infrared /SWIR/ pushbroom imaging system using a 64-element PbS detector array

Research evidence indicates that data in the short wave infrared (SWIR) spectral region will greatly improve the information content of remotely sensed data. Bands are required in the 1.55-1.75 micron and 2.08-2.35 micron spectral regions for a variety of agricultural and geological investigations. It is anticipated that future Landsat sensors will use pushbroom linear array technology to obtain high resolution, improved sensitivity and increased system reliability. To obtain early laboratory and field data, an airborne pushbroom image system has been designed for operation in the short wave infrared spectral region. The system uses a 64-element staggered PbS array and is operated at 195 K; the instrument has been designed to operate in an aircraft and will view a 19 degree swath width with a 5.8 mrad IFOV. The spectral bandwidth of each channel is .05 micron and the noise equivalent reflectivity in the order of .2% is provided. The requirements for more advanced detector arrays for use in future NASA spacecraft remote sensing instruments are also discussed.

Husain-Abidi, A. S.↗

Deduction of coronal magnetic fields using microwave spectroscopy

Gyroresonance opacity renders the solar corona optically thick at frequencies which are low integral multiples of the local gyrofrequency. This causes the microwave spectrum of sunspots to be sensitive to the strength of coronal magnetic fields. The concept is illustrated by high spectral resolution observations of a sunspot acquired with the Owens Valley frequency-agile interferometer. The observed spectrum is compared to the results of three-dimensional atmospheric model calculations in which the sunspot field is represented by the potential field of a dipole located beneath the photosphere. The comparison enables the depth, orientation and magnetic moment of the dipole that best fits the observations to be determined. Since such observations require that the microwave emission be resolved spectrally, not spatially, the technique may be applicable to the study of stellar coronal fields.

Hurford, G. J.↗

The AXAF high resolution camera (HRC) and its use for observations of distant clusters of galaxies

The High Resolution Camera being developed for AXAF is briefly described, comparing it with its predecessor, the Einstein HRI, and providing preliminary performance data. The HRC is a 10 cm x 10 cm detector with CsI coated microchannel plates providing a large field of view device with high X-ray quantum efficiency. The overall sensitivity of the HRC on AXAF is about 50 times that of the Einstein HRI. An example of the power of this instrument is discussed in the context of studies of distant clusters of galaxies. The HRC can detect individual galaxies in a cluster of redshift 1, if they are similar to the early-type galaxies in nearby clusters that have been observed by the Einstein instruments. The HRC will be used to measure the luminosity function for clusters of galaxies as a function of their distance up to a redshift of 1. This will allow observation of evolutionary effects in clusters as a whole, while the detection of individual galaxies will permit studies of galaxy evolution in a cluster environment.

Murray, S. S.↗

Evolution of miniature detectors and focal plane arrays for infrared sensors

Sensors that are sensitive in the infrared spectral region have been under continuous development since the WW2 era. A quest for the military advantage of 'seeing in the dark' has pushed thermal imaging technology toward high spatial and temporal resolution for night vision equipment, fire control, search track, and seeker 'homing' guidance sensing devices. Similarly, scientific applications have pushed spectral resolution for chemical analysis, remote sensing of earth resources, and astronomical exploration applications. As a result of these developments, focal plane arrays (FPA) are now available with sufficient sensitivity for both high spatial and narrow bandwidth spectral resolution imaging over large fields of view. Such devices combined with emerging opto-electronic developments in integrated FPA data processing techniques can yield miniature sensors capable of imaging reflected sunlight in the near IR and emitted thermal energy in the Mid-wave (MWIR) and longwave (LWIR) IR spectral regions. Robotic space sensors equipped with advanced versions of these FPA's will provide high resolution 'pictures' of their surroundings, perform remote analysis of solid, liquid, and gas matter, or selectively look for 'signatures' of specific objects. Evolutionary trends and projections of future low power micro detector FPA developments for day/night operation or use in adverse viewing conditions are presented in the following test.

Watts, Louis A.↗

GLAST and Ground-Based Gamma-Ray Astronomy

The launch of the Gamma-ray Large Area Space Telescope together with the advent of a new generation of ground-based gamma-ray detectors such as VERITAS, HESS, MAGIC and CANGAROO, will usher in a new era of high-energy gamma-ray astrophysics. GLAST and the ground based gamma-ray observatories will provide highly complementary capabilities for spectral, temporal and spatial studies of high energy gamma-ray sources. Joint observations will cover a huge energy range, from 20 MeV to over 20 TeV. The LAT will survey the entire sky every three hours, allowing it both to perform uniform, long-term monitoring of variable sources and to detect flaring sources promptly. Both functions complement the high-sensitivity pointed observations provided by ground-based detectors. Finally, the large field of view of GLAST will allow a study of gamma-ray emission on large angular scales and identify interesting regions of the sky for deeper studies at higher energies. In this poster, we will discuss the science returns that might result from joint GLAST/ground-based gamma-ray observations and illustrate them with detailed source simulations.

McEnery, Julie↗

HST/WFC3 Observations of Giant Hot Exoplanets

Low resolution thermal emission spectra of roger two dozen extrasolar planets have been measured using Spitzer, and HST observations of a few key exoplanets have defined molecular abundances via transmission spectroscopy. However, current models for the atmospheric structure of these worlds exhibit degeneracies wherein different combinations of temperature and molecular abundance profiles can fit the same Spitzer data. The advent of the IR capability on HST/WFC3 allows us to address this problem. We are currently obtaining transmission spectroscopy of the 1.4-micron water band in a sample of 13 planets, using the G141 grism on WFC3, Among the abundant molecules, only water absorbs at this wavelength, and our measurement of water abundance will enable us to break the degeneracies in the Spitzer results with minimal model assumptions. We will also use the G141 grism to observe secondary eclipses for 7 very hot giant exoplanets at 1.5-microns, including several bright systems in the Kepler and CoRoT fields. The strong temperature sensitivity of the thermal continuum at 1.5-microns provides high leverage on atmospheric temperature for these worlds, again helping to break degeneracies in interpreting the Spitzer data. We here describe preliminary results for several exoplanets observed in this program,

Deming, D.↗

Pioneer 9 plasma wave and solar plasma measurements for the August 1972 storm period

The solar disturbances of August 1972 produced large-scale solar wind perturbations that were detected by the Pioneer 9 plasma probe, electric field detector, and magnetometer for an extended time period commencing early on August 3. During this ten-day interval the interplanetary plasma parameters at r approximately equal 0.8 AU varied over unusually wide ranges, so that the conditions for generation of high and low VLF wave levels could be identified fairly readily. It is demonstrated that no measurable signals were detected in the broadband electric field channel (sensitive to waves with f greater than or equal to 100 Hz in the spacecraft frame of reference) unless the proton density was high enough to yield a proton plasma frequency with f greater than or about equal to 100 Hz. The analysis suggests that waves related to ion acoustic oscillations were detected throughout the extended storm period.

Scarf, F. L.↗

Department of Energy Project DE-SC0012198: Probing Electron-Molecule Scattering with HHG: Theory and Experiment (Final Report)

The study of the motion of atoms in molecules is important to understanding many areas of physical and life sciences. Such motion occurs on many different times scales, with electronic motion occurring on a sub-femtosecond time scale, and simple vibrational motion in tens to hundreds of femtoseconds. One way to follow such processes in real time is by the use of shortpulsed lasers, and in particular by studying time-resolved photoionization and the related process of high-harmonic generation (HHG). Thus there has been much effort to develop the tools necessary to probe molecular systems using short pulse lasers and understanding the sensitivity of the different possible probes to the time dependent geometric structure as well as the electronic structure of molecules. Our research has particularly focused on the connection between high-field processes and the more traditional weak field photoionization processes. Strong field and weak field processes can be connected through models that involve the same matrix elements. We have demonstrated in our study of HHG from SF 6 that the spectrum is sensitive to the interplay between the angular dependence of the ionization step and recombination step. In our study of rescattering spectroscopy, we have shown that with a combination of experiment and theory, we can use this high-field spectroscopy to determine molecular structure in molecules such as C 2 H 4 . We have also developed new computational tools based on overset grids to enable studies on larger molecular systems which use much more robust numerical approaches so that the resulting code can be a tool that non-specialists can use to study related systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision spectroscopy of fast, hot, exotic isotopes using machine-learning-assisted event-by-event Doppler correction

We propose an experimental scheme for performing sensitive, high-precision laser spectroscopy studies on fast exotic isotopes. By inducing a stepwise resonant ionization of the atoms traveling inside an electric field and subsequently detecting the ion and the corresponding electron, time-, and position-sensitive measurements of the resulting particles can be performed. Using a mixture density network, we can leverage this information to predict the initial energy of individual atoms and thus apply a Doppler correction of the observed transition frequencies on an event-by-event basis. We conduct numerical simulations of the proposed experimental scheme and show that kHz-level uncertainties can be achieved for ion beams produced at extreme temperatures ( > 10 8 K), with energy spreads as large as 10 keV and nonuniform velocity distributions. The ability to perform in-flight spectroscopy, directly on highly energetic beams, offers unique opportunities to study short-lived isotopes with lifetimes in the millisecond range and below, produced in low quantities, in hot and highly contaminated environments, without the need for cooling techniques. Such species are of marked interest for nuclear structure, astrophysics, and new physics searches. Published by the American Physical Society 2024

Udrescu, S. M. (ORCID:000000021989576X)↗

Phase Calibration of Microphones by Measurement in the Free-field

Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.

Shams, Qamar A.↗

Vertical Structure and Ice Production Processes of Shallow Convective Postfrontal Clouds over the Southern Ocean in MARCUS. Part II: Modeling Study

Abstract Part I of this series presented a detailed overview of postfrontal mixed-phase clouds observed during the Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) field campaign. In Part II, we focus on a multiday (23–26 February 2018) case with the aim of understanding ice production as well as model sensitivity to ice process parameterizations using the Weather Research and Forecasting (WRF) Model. The control simulation with the Predicted Particle Properties (P3) microphysics scheme underestimates the ice content and overestimates the supercooled liquid water content, contrary to the bias common in global climate models. The simulations targeted at ice production processes show negligible sensitivity to cloud droplet number concentrations. Further, neither increasing ice nuclei particle (INP) concentrations to an unrealistic level nor adjusting it to MARCUS field estimations alone guarantees more ice production in the model. However, the simulated clouds are found to be highly sensitive to the implementation of immersion freezing, the thresholding of condensation/deposition freezing initiation, and the rime splintering process. By increasing immersion freezing of cloud droplets, relaxing thresholds for condensation/deposition freezing, or removing rime splintering thresholds, the model significantly improves its performance in producing ice. The relaxation of the immersion freezing temperature threshold to the observed cloud-top temperature suggests an in-cloud seeder–feeder mechanism. The results of this work call for an increase in observations of INP, especially over the remote Southern Ocean and at relatively high temperatures, and measurements of ice particle size distributions to better constrain ice nucleating processes in models.

Meteorology & Atmospheric Sciences↗

A portable and reusable sensor system based on graphene for real-time and sensitive detection of lead ions in water

Long-term exposure to Pb 2+ can cause irreversible damage to the nervous, cardiovascular, and reproductive systems. Therefore, developing a fast and sensitive detection system capable of monitoring minuscule concentrations of Pb 2+ is essential. In this study, we demonstrated a fully portable sensor system enabling rapid, sensitive, and real-time monitoring of Pb 2+ . The sensor system adopted the remote-gate field-effect transistor (RGFET) detection scheme and was easy to operate, even for non-experts. The sensor system comprised two printed circuit boards (PCBs): a sensor PCB with a remote-gate electrode and an analyzer PCB with a metal-oxide-semiconductor field-effect transistor (MOSFET) transducer and peripheral electronics to manage sensor signals. To achieve a high sensitivity for Pb 2+ , we utilized graphene ink drop-casted on the sensor PCB as a sensing membrane. The graphene film was easy to deposit and remove, enabling the sensor PCB to be reused multiple times. The sensor system was further linked to a smartphone application that instantly monitors the sensor response, allowing for rapid point-of-use detection. The sensor exhibited a high sensitivity of 21.7% when the limit of detection (LOD) value of 1 nM (∼0.2 ppb) was detected, and the typical detection time for each sample was approximately 60 seconds. This portable sensor system advances sensing technologies and could potentially supplement expensive, laborious conventional sensing equipment.

54 ENVIRONMENTAL SCIENCES↗