Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat map”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Nonlinear burn control in ITER using adaptive allocation of actuators with uncertain dynamics

Abstract ITER will be the first tokamak to sustain a fusion-producing, or burning, plasma. If the plasma temperature were to inadvertently rise in this burning regime, the positive correlation between temperature and the fusion reaction rate would establish a destabilizing positive feedback loop. Careful regulation of the plasma’s temperature and density, or burn control, is required to prevent these potentially reactor-damaging thermal excursions, neutralize disturbances and improve performance. In this work, a Lyapunov-based burn controller is designed using a full zero-dimensional nonlinear model. An adaptive estimator manages destabilizing uncertainties in the plasma confinement properties and the particle recycling conditions (caused by plasma–wall interactions). The controller regulates the plasma density with requests for deuterium and tritium particle injections. In ITER-like plasmas, the fusion-born alpha particles will primarily heat the plasma electrons, resulting in different electron and ion temperatures in the core. By considering separate response models for the electron and ion energies, the proposed controller can independently regulate the electron and ion temperatures by requesting that different amounts of auxiliary power be delivered to the electrons and ions. These two commands for a specific control effort (electron and ion heating) are sent to an actuator allocation module that optimally maps them to the heating actuators available to ITER: an electron cyclotron heating system (20 MW), an ion cyclotron heating system (20 MW), and two neutral beam injectors (16.5 MW each). Two different actuator allocators are presented in this work. The first actuator allocator finds the optimal mapping by solving a convex quadratic program that includes actuator saturation and rate limits. It is nonadaptive and assumes that the mapping between the commanded control efforts and the allocated actuators (i.e. the effector model) contains no uncertainties. The second actuator allocation module has an adaptive estimator to handle uncertainties in the effector model. This uncertainty includes actuator efficiencies, the fractions of neutral beam heating that are deposited into the plasma electrons and ions, and the tritium concentration of the fueling pellets. Furthermore, the adaptive allocator considers actuator dynamics (actuation lag) that contain uncertainty. This adaptive allocation algorithm is more computationally efficient than the aforementioned nonadaptive allocator because it is computed using dynamic update laws so that finding the solution to a static optimization problem is not required at every time step. A simulation study assesses the performance of the proposed adaptive burn controller augmented with each of the actuator allocation modules.

Physics↗

The effects of Reynolds number, rotor incidence angle, and surface roughness on the heat transfer distribution in a large-scale turbine rotor passage

A combined experimental and computational program was conducted to examine the heat transfer distribution in a turbine rotor passage geometrically similiar to the Space Shuttle Main Engine (SSME) High Pressure Fuel Turbopump (HPFTP). Heat transfer was measured and computed for both the full-span suction and pressure surfaces of the rotor airfoil as well as for the hub endwall surface. The primary objective of the program was to provide a benchmark-quality data base for the assessment of rotor passage heat transfer computational procedures. The experimental portion of the study was conducted in a large-scale, ambient temperature, rotating turbine model. Heat transfer data were obtained using thermocouple and liquid-crystal techniques to measure temperature distributions on the thin, electrically-heated skin of the rotor passage model. Test data were obtained for various combinations of Reynolds number, rotor incidence angle and model surface roughness. The data are reported in the form of contour maps of Stanton number. These heat distribution maps revealed numerous local effects produced by the three-dimensional flows within the rotor passage. Of particular importance were regions of local enhancement produced on the airfoil suction surface by the main-passage and tip-leakage vortices and on the hub endwall by the leading-edge horseshoe vortex system. The computational portion consisted of the application of a well-posed parabolized Navier-Stokes analysis to the calculation of the three-dimensional viscous flow through ducts simulating the a gas turbine passage. These cases include a 90 deg turning duct, a gas turbine cascade simulating a stator passage, and a gas turbine rotor passage including Coriolis forces. The calculated results were evaluated using experimental data of the three-dimensional velocity fields, wall static pressures, and wall heat transfer on the suction surface of the turbine airfoil and on the end wall. Particular attention was paid to an accurate modeling of the passage vortex and to the development of the wall boundary layers including crossflow.

Blair, Michael F.↗

Multisensor Platform Deployment Proposal for International Polar Year (IPY)

High resolution thermal surveys will be acquired to quantify the thermal balance of several active, changing volcanoes which are difficult to monitor for change. Maps of the heat flow on these volcanoes will help in understanding the internal processes changing their surfaces. Correlation of heat flow with volcano deformation and seismicity will help in the understanding of this active region. Remote sensing of composition and biology of warm, bare areas will allow a better understanding of these extreme ecosystems. The thermal survey s and ancillary compositional and biological mapping will be used to focus searches on Mars for similar environments.Mars is a polar desert, much like Antarctica, and one of the few places on Mars where life could exist is in a thermal anomaly like the bare, warm ground areas on the Antarctic volcanoes. We will study the factors making these areas habitable and hone the remote sensing techniques that may be used to detect these features on Mars. Warm areas on Mars (as on the Antarctic volcanoes) are especially hospitable to humans as well, making their discovery on Mars of primary importance for human occupation.

Antarctica↗

Entry into outer planet environments. II - Performance of volume reflecting hyperpure silica heat shields

The performance of hyperpure silica heat shields that backscatter incident radiation in the depths of the material, i.e., a volume reflecting heat shield, is mapped for probes entering the atmospheres of Saturn and Uranus. Three models of each atmosphere are considered; the warm, nominal, and cool models. The most recent thermophysical and optical properties of hyperpure silica are employed. Detailed incident radiative spectra and the effects of ablation on radiative and convective heating obtained from benchmark flowfield solutions are used. In-depth material response is examined and results are presented in terms of the peak rear-face temperature as a function of initial thickness for each atmosphere. Results are compared with carbon phenolic heat-shield requirements.

Howe, J. T.↗

Automated thermal mapping techniques using chromatic image analysis

Thermal imaging techniques are introduced using a chromatic image analysis system and temperature sensitive coatings. These techniques are used for thermal mapping and surface heat transfer measurements on aerothermodynamic test models in hypersonic wind tunnels. Measurements are made on complex vehicle configurations in a timely manner and at minimal expense. The image analysis system uses separate wavelength filtered images to analyze surface spectral intensity data. The system was initially developed for quantitative surface temperature mapping using two-color thermographic phosphors but was found useful in interpreting phase change paint and liquid crystal data as well.

Buck, Gregory M.↗

Automated thermal mapping techniques using chromatic image analysis

Thermal imaging techniques are introduced using a chromatic image analysis system and temperature sensitive coatings. These techniques are used for thermal mapping and surface heat transfer measurements on aerothermodynamic test models in hypersonic wind tunnels. Measurements are made on complex vehicle configurations in a timely manner and at minimal expense. The image analysis system uses separate wavelength filtered images to analyze surface spectral intensity data. The system was initially developed for quantitative surface temperature mapping using two-color thermographic phosphors but was found useful in interpreting phase change paint and liquid crystal data as well.

Buck, Gregory M.↗

Extending the Heat Index

The Heat Index is a widely used measure of apparent temperature that accounts for the effects of humidity using Steadman’s model of human thermoregulation. Steadman’s model, however, gives unphysical results when the air is too hot and humid or too cold and dry, leading to an undefined Heat Index. For example, at a relative humidity of 80%, the Heat Index is only defined for temperatures in the range of 288-304 K (59-88 degrees Fahrenheit). Here, Steadman’s thermoregulation model is extended to define the Heat Index for all combinations of temperature and humidity, allowing for an assessment of Earth’s future habitability. The extended Heat Index can be mapped onto physiological responses of an idealized human, such as heat exhaustion, heat stroke, and even heat death, providing an indication of regional health outcomes for different degrees of global warming.

54 ENVIRONMENTAL SCIENCES↗

Convective Enhancement of Icing Roughness Elements in Stagnation Region Flows

To improve existing ice accretion simulation codes, more data regarding ice roughness and its effects on convective heat transfer are required. To build on existing research on this topic, this study used the Vertical Icing Studies Tunnel (VIST) at NASA Glenn Research to model realistic ice roughness in the stagnation region of a NACA 0012 airfoil. Using the VIST, a test plate representing the leading 2% chord of the airfoil was subjected to flows of 7.62 m/s (25 ft/s), 12.19 m/s (40 ft/s), and 16.76 m/s (55 ft/s). The test plate was fitted with 3 surfaces, each with a different representation of ice roughness: 1) a control surface with no ice roughness, 2) a surface with ice roughness with element height scaled by 10x and streamwise rough zone width from the stagnation point scaled by 10x, and 3) a surface with ice roughness with element height scaled by 10x and streamwise rough zone width from the stagnation point scaled by 25x. Temperature data from the tests were recorded using an infrared camera and thermocouples imbedded in the test plate. From the temperature data, a convective heat transfer coefficient map was created for each case. Additional testing was also performed to validate the VIST's flow quality. These tests included five-hole probe and hot-wire probe velocity traces to provide flow visualization and to study boundary layer formation on the various test surfaces. The knowledge gained during the experiments will help improve ice accretion codes by providing heat transfer coefficient validation data and by providing flow visualization data helping understand current and future experiments performed in the VIST.

Icing↗

Local convection characteristics of inline arrangement of Kagome-shaped unit cells in a square duct

Transient liquid crystal thermography experiments have been conducted to determine detailed convective heat transfer coefficients at the endwalls of lattice-frame configurations based on Kagome-shaped unit cells. Kagome unit cells with porosity of 0.88 were arranged in an inline manner, where two such arrangements were studied. In the first arrangement, a total of ten unit cells were placed next to each other along the streamwise direction resulting in a continuous configuration. In the 2nd arrangement, alternate unit cells from the continuous configuration were dropped, resulting in a discrete configuration which featured a total of 5 Kagome unit cells. Due to the asymmetric nature of the strut connections within the unit cell, the convective heat transfer coefficient maps were determined for the two opposite walls where the struts meet the endwalls. Transient liquid crystal experiments were conducted for Reynolds number ranging between 10,000 and 30,000. Here, the study was focused on the developing nature of flow along the streamwise direction and the local convection characteristics for continuous and discrete arrangement of unit cells. For the continuous configuration, the Nusselt number ratios (N u /Nu 0 ) varied between 3.15–3.46 and 2.75–2.89 for the two walls A and B, respectively. For the discrete configuration, convective heat transfer coefficients varied between 2.56–2.71 and 2.09–2.40 for the two walls. Kagome unit cells have the potential to be fabricated through inexpensive manufacturing routes such as wire-woven method and these unit cells find their applications in the areas which require different heat transfer levels on opposite walls.

Kagome↗

Heat Transfer in a Superelliptic Transition Duct

Local heat transfer measurements were experimentally mapped using a transient liquid-crystal heat transfer technique on the surface of a circular-to-rectangular transition duct. The transition duct had a length-to-diameter ratio of 1.5 and an exit-plane aspect ratio of 3. The crosssectional geometry was defined by the equation of a superellipse. The cross-sectional area was the same at the inlet and exit but varied up to 15 percent higher through the transition. The duct was preheated to a uniform temperature (nominally 64 C) before allowing room temperature air to be suddenly drawn through it. As the surface cooled, the resulting isothermal contours on the duct surface were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the surface temperature and time data for all points on the duct surfaces during each test. Using this surface temperature-time data together with the temperature of the air flowing through the model and the initial temperature of the model wall, the heat transfer coefficient was calculated by employing the classic one-dimensional, semi-infinite wall heat transfer conduction model. Test results are reported for inlet diameter-based Reynolds numbers ranging from 0.4x106 to 2.4x106 and two grid-generated freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.

Poinsatte, Philip↗

Spacesuit Water Membrane Evaporator Development for Lunar Missions

For future lunar extra-vehicular activities (EVA), one method under consideration for rejecting crew and electronics heat involves evaporating water through a hydrophobic, porous Teflon membrane. A Spacesuit Water Membrane Evaporator (SWME) prototype using the Teflon membrane was tested successfully by Ungar and Thomas (2001) with predicted performance matching test data well. The above referenced work laid the foundation for the design of the SWME development unit, which is being considered for service in the Constellation System Spacesuit Element (CSSE) Portable Life Support System (PLSS). Multiple PLSS SWME configurations were considered on the basis of thermal performance, mass, volume, and performance and manufacturing risk. All configurations were a variation of an alternating concentric water and vapor channel configuration or a stack of alternating rectangular water and vapor channels. Supporting thermal performance trades mapped maximum SWME heat rejection as a function of water channel thickness, vapor channel thickness, channel length, number of water channels, porosity of the membrane structural support, and backpressure valve throat area. Preliminary designs of each configuration were developed to determine total mass and volume as well as to understand manufacturing issues. Review of configurations led to the selection of a concentric annulus configuration that meets the requirements of 800 watts (W) of heat rejection. Detailed design of the SWME development unit will be followed by fabrication of a prototype test unit, with thermal testing expected to start in 2008.

Vogel, Matt R.↗

Arcjet Ablation of Stony and Iron Meteorites

A test campaign was conducted placing meteorites in the 60 MW plasma Arcjet Interaction Heating Facility at NASA Ames Research Center, with the aim to achieve flight-relevant conditions for asteroid impacts in Earth's atmosphere and to provide insight into how meteoritic materials respond to extreme entry heating environments. The test conditions at heat flux of 4000 W/m2 and 140 kPa stagnation pressure are comparable to those experienced by a 30-meter diameter asteroid moving at 20 km/s velocity at 65 km altitude in the Earth's atmosphere. Test objects were a stony type H5 ordinary chondrite (Tamdakht) and an iron type IAB-MG meteorite (Campo Del Cielo), and included the terrestrial analogs Dense Flood Basalt and Fused Silica. All samples were exposed for only a few seconds in the plasma stream. Significant melt flow and vaporization was observed for both the stony and iron meteorites during exposure. Mass loss from spallation of fragments was also observed. Vapor emitted atomic lines from alkali metals and iron, but did not emit the expected MgO molecular band emissions. The meteoritic melts flowed more rapidly, indicating lower viscosity, than those of Fused Silica. The surface recession was mapped. The effective heat of ablation derived from this showed that ablation under these conditions occurred in the melt-dominated regime. Ablation parameters have an effect on ground damage estimates. A bias in ablation parameters towards the melt-dominated regime would imply that impacting asteroids survive to lower altitude, and therefore could possibly have airbursts with a larger ground damage footprint.

Asteroid↗

Arcjet Ablation of Stony and Iron Meteorites

A test campaign was conducted placing meteorites in the 60 MW plasma Arcjet Interaction Heating Facility at NASA Ames Research Center, with the aim to achieve flight-relevant conditions for asteroid impacts in Earth's atmosphere and to provide insight into how meteoritic materials respond to extreme entry heating environments. The test conditions at heat flux of 4000 W/m2 and 140 kPa stagnation pressure are comparable to those experienced by a 30-meter diameter asteroid moving at 20 km/s velocity at 65 km altitude in the Earth's atmosphere. Test objects were a stony type H5 ordinary chondrite (Tamdakht) and an iron type IAB-MG meteorite (Campo Del Cielo), and included the terrestrial analogs Dense Flood Basalt and Fused Silica. All samples were exposed for only a few seconds in the plasma stream. Significant melt flow and vaporization was observed for both the stony and iron meteorites during exposure. Mass loss from spallation of fragments was also observed. Vapor emitted atomic lines from alkali metals and iron, but did not emit the expected MgO molecular band emissions. The meteoritic melts flowed more rapidly, indicating lower viscosity, than those of Fused Silica. The surface recession was mapped. The effective heat of ablation derived from this showed that ablation under these conditions occurred in the melt-dominated regime. Ablation parameters have an effect on ground damage estimates. A bias in ablation parameters towards the melt-dominated regime would imply that impacting asteroids survive to lower altitude, and therefore could possibly have airbursts with a larger ground damage footprint.

Arcjet↗

Start-up and Emergency Shutdown Modeling for a Coal-fired 10MWe sCO₂ Power Plant

As part of a Phase II Front End Engineering Design (FEED) study for the DOE Fossil Fuel Large Scale Pilots program, investigations of novel start-up and emergency shutdown methods for a stoker-fed, coal-fired, 10MWe sCO₂ power plant proposal were performed. These investigations were performed using 1D transient system models of the plant created within the GT-SUITE system modeling platform. The system model components were created using vendor quotation data (heat exchangers), performance maps (turbomachines), or FMU models (fired heater). Previously, Echogen Power Systems (Echogen) has used a sCO₂ power cycle start-up method that fills the system with liquid CO₂ to facilitate easy use of an electrically-driven start pump to transition the system from initial CO₂ fill to turbo-compressor initialization. The novel start-up method presented attempts this transition with a minimal filling of the system with liquid CO₂, to reduce the total CO₂ inventory required. This method leaves the start pump vulnerable to a two phase inlet condition as system pressure is below the CO₂ saturation pressure for the condenser cooling water temperature (Tcw). System model cases at Tcw of 18°C, 26°C, and 32°C, corresponding to cold, design, and hot ambient days, were analyzed to determine if the SP inlet condition could be kept as a subcooled liquid and estimate the CO₂ inventory reduction amount./p> Stoker-fed, coal-fired heaters continue to emit heat for some time even after emergency shutdown from events such as a power failure. This heat emission would lead to a failure of the fired heater, as the metal overheats, if the CO₂ flow is shut off. The emergency shutdown method presented utilizes CO₂ vented by a controllable vent valve (CRV) to provide CO₂ cooling flow to the fired heater. To determine the effectiveness of this method at keeping the fired heater peak tubing metal temperature below the ASME material temperature limit, for pressures below 5 MPa, of 816 °C, system model cases with CRV diameters ranging from 4” to 10”, and an alternative CO₂ vent routing with CRV size of 6”, were investigated./p>

01 COAL, LIGNITE, AND PEAT↗

Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MULTI-TECHNIQUE CHARACTERIZATION OF SUPERCONDUCTING MATERIALS FOR PARTICLE ACCELERATOR APPLICATIONS

We investigated the performance limitations of superconducting radio-frequency (SRF) cavities and materials using multiple experimental techniques. In particular, this study focuses on understanding the surface properties of nitrogen-doped Nb cavities and super?conducting thin films with higher Tc such as Nb3Sn. The main goal of this work is to use different techniques to better understand each aspect of the complex loss mechanism in superconductors to further improve the already highly efficient SRF cavities. Nitrogen doping applied to a Nb SRF cavity significantly improves the quality factor Q0 compared to a conventional Nb cavity, at an expense of reduced maximum accelerating gradient. The early quench mechanism was analyzed by using temperature maps before and during the quenching. The temperature maps revealed insignificant heating before the quench, and we concluded that nitrogen doping reduces critical magnetic fields in local regions, leading to premature quenching. To understand the origin of the increasing Q0 with the rf field, the density of states (DOS) of cold spots from nitrogen-doped and standard cavities were measured and analyzed using scanning tunneling microscopy. The results suggested that nitrogen doping reduces the spatial inhomogeneity of superconducting properties and shrinks the metallic suboxide layers, which tunes the DOS in such a way as to produce the field-induced reduction in the surface resistance. To characterize SRF thin films, an experimental setup for measuring a coplanar waveguide (CPW) resonator was developed and tested. A surface impedance measurement of the Nb film showed good agreement with the BCS calculation. The preliminary results from measurements of Nb3Sn and NbTiN films are also presented here. The nonlinear Meissner effect was investigated in Nb3Sn film CPW resonators by mea?suring the resonant frequency as a function of a parallel magnetic field. Contrary to a conventional quadratic dependence of the penetration depth ?(B) on the applied magnetic field B, as expected in s-wave superconductors, nearly a linear increase of ?(B) with B was observed. It was concluded that this behavior of ?(B) is due to weakly linked grain bound?aries on the polycrystalline Nb3Sn films, which can mimic the NLME expected in a clean d-wave superconductor.

Makita, Junki↗

Dynamics of heat-pipe reactors

A split-core heat pipe reactor, fueled with either U(233)C or U(235)C in a tungsten cermet and cooled by 7-Li-W heat pipes, was examined for the effects of the heat pipes on reactor while trying to safely absorb large reactivity inputs through inherent shutdown mechanisms. Limits on ramp reactivity inputs due to fuel melting temperature and heat pipe wall heat flux were mapped for the reactor in both startup and at-power operating modes.

Niederauer, G. F.↗

Dynamics of heat-pipe reactors.

A split-core heat-pipe reactor fueled with either 233-UC or 235-UC in a tungsten cermet and cooled by 7-Li-W heat pipes is examined for the effects of the heat pipes on this reactor in trying to safely absorb large reactivity inputs through inherent shutdown mechanisms. Limits on ramp reactivity inputs due to fuel-melting temperature and heat-pipe wall heat flux are mapped for the reactor in both startup and at-power operating modes.

Niederauer, G. F.↗