Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hardware security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

232 records · Page 13

Active High Assurance Authentication Protocol (AHAAP)

The AHAAP Maturation Project involves maturation and evaluation of a patented zero-trust tamper-resistant high-assurance session-less dynamic and active device authentication protocol that simultaneously authenticates identity and provides integrity verification in a single step, substantially reducing the risk of cyberattack, and eliminating the need for costly and complex conventional communication security systems requirements (i.e., cryptography, Public Key Infrastructure (PKI), and key management). These cybersecurity attributes of the technology must be preserved when applying the technology to different cybersecurity solutions, including Command & Control (C&C), Over-the-Air (OTA) update, Common Access Card (CAC), and distributed energy resource (DER) implementations, among others. The technology research objective is to test and verify that the cybersecurity attributes of the technology are not degraded in different cybersecurity applications. The primary technology development objective is to build minimum viable products to demonstrate the technology addresses today’s cybersecurity threats so that prospective investors, strategic partners, regulatory agencies, and commercial customers can interact with and assess the protection assured by the technology. The AHAAP Maturation Project goal is to develop, test, and validate one or more AHAAP implementations. The AHAAP Maturation Project tasks are: (i) engineer AHAAP implementation software, (ii) build a functional prototype that implements the AHAAP software for demonstration, testing, analysis, and evaluation purposes, and (iii) generate a report detailing the results of the AHAAP C&C software and hardware implementation. The final project deliverables are: (i) AHAAP software implementation and prototype, (ii) a report from Sandia National Laboratories detailing the results of the AHAAP implementations.

97 MATHEMATICS AND COMPUTING↗

Reducing module soiling with scalable and robust photocatalytic coatings

The air-glass interface at the front of a photovoltaic (PV) module reflects approximately 4% of incident light, decreasing the potential power output of the module by the same amount. Today’s modules reduce this loss by adding a low-refractive-index (1.25-1.30) SiO2 coating to the sunward side of the module glass; this antireflection coating recovers approximately 3% of the 4% light that would otherwise be lost. While such antireflection coatings work very well on clean, new modules, they do not inhibit soiling—the accumulation of soilants such as dust, pollen, soot, or other foreign material—on the module glass, and soilants reflect and scatter incident light. An improved coating would serve provide not only an antireflection effect, but also an anti-soiling effect. The goal of this project was to develop such a coating and provide a path for it to be manufactured in the U.S. The project successfully designed and fabricated coatings that provided >3% transmittance gain compared to bare glass (matching the performance of commercial antireflection coatings) and displayed anti-soiling behavior in standard laboratory soiling effects. This was achieved by using a Swift Coat proprietary coating deposition technique, aerosol impact-driven assembly (AIDA), to control the porosity and thus refractive index of coatings of photocatalytic materials—such as TiO2—that would otherwise increase (instead of decrease) reflection. These combined antireflection/anti-soiling coatings passed PV industry standard module reliability tests as well as coating-specific abrasion tests, showing that they have the durability needed for decades in the field. Swift Coat scaled the AIDA hardware and deposition process to make mini-modules that were monitored for nearly two years during field tests administered by a third party, as well as demonstrated scaling to the widths of full-sized modules. The fielded mini-modules outperformed reference modules (with commercial antireflection coatings) in two locations, providing a 1% absolute average performance boost and larger increases during periods of heavier soiling. Swift Coat’s cost analysis indicated a coating manufacturing cost below the sales price of today’s antireflection coatings. More than five module manufacturers sampled and assessed the coatings, and three provided letters of support. The coating developed in this project increases the energy output of PV modules, thereby decreasing the cost per kilowatt-hour of solar energy generated. Cheaper solar electricity benefits the public by accelerating the transition to a stable, affordable, carbon-free energy economy. In addition, for select applications in which PV modules are highly visible—such as on residential rooftops—the coating provides an aesthetic benefit because it stays cleaner than today’s modules. Finally, Swift Coat and its prospective customers are U.S. companies, and successful commercialization of this technology will provide U.S. jobs and a secure solar supply chain.

14 SOLAR ENERGY↗

Generic characterization of electrical test benches for AC- and HVDC-connected wind power plants

The electrical test and assessment of wind turbines go hand in hand with standards and network connection requirements. In this paper, the generic structure of advanced electrical test benches, including grid emulator or controllable grid interface, wind torque emulator, and device under test, is proposed to harmonize state-of-the-art test sites. On the other hand, modern wind turbines are under development towards new features, concerning grid-forming, black-start, and frequency support capabilities as well as harmonic stability and control interaction considerations, to secure the robustness and stability of renewable-energy-based power systems. Therefore, it is necessary to develop new and revised test standards and methodologies to address the new features of wind turbines. This paper proposes a generic test structure within two main groups, including open-loop and closed-loop tests. The open-loop tests include the IEC 61400-21-1 standard tests as well as the additional proposed test options for the new capabilities of wind turbines, which replicate grid connection compliance tests using open-loop references for the grid emulator. In addition, the closed-loop tests evaluate the device under test as part of a virtual wind power plant and perform real-time simulations considering the grid dynamics. The closed-loop tests concern grid connection topologies consisting of AC and HVDC, as well as different electrical characteristics, including impedance, short-circuit ratio, inertia, and background harmonics. The proposed tests can be implemented using available advanced test benches by adjusting their control systems. The characteristics of a real power system can be emulated by a grid emulator coupled with real-time digital simulator systems through a high-bandwidth power-hardware-in-the-loop interface.

17 WIND ENERGY↗

Microgrid's Role in Enhancing the Security and Flexibility of City Energy Systems

Smart cities depend on flexible and secure energy systems to ensure resilient power for critical infrastructure; however, recent weather-related events and cyberattacks have highlighted weaknesses in our energy systems, with the potential for widespread economic and security impacts. As stated by the Executive Office of the President, "the resilience of the US electric grid is a key part of the nation's defense against severe weather." To address the energy delivery security challenge, microgrids are rising as a viable solution that enhances the flexibility and resilience of the distribution grid and boosts the reliability of the local supply for the end-user. Traditionally, high capital investment has been a barrier to large-scale adoption of microgrid technology. Understanding the flexibility and resilience benefits of microgrids and accounting for the associated value streams can make the microgrid's proposition economically viable. In this chapter, microgrids' utility and their potential to serve as a flexible and resilient resource for the utility grid by providing capabilities such as peak shaving, demand response, and frequency regulation is presented. Moreover, other value streams, such as (1) their ability to island during a disaster and sustain critical loads which makes them a robust resilience solution for end-users, in the event of the utility grid outage and (2) microgrids also provide a flexible platform for integrating distributed energy resources in conjunction with storage and conventional generation technologies, strengthen microgrid's role in reducing the over-arching goal of emission reduction. Given the myriad of benefits associated with microgrids, we present strategies which can be employed for making microgrid itself resilient against physical and cyberthreats by employing hardware, software, and personnel training solutions to operate the microgrid before, during, and after a potential disaster. This chapter, thus, provides a holistic study of the microgrid as a resilience resource, for the utility grid, and a self-contained end-user for the end-user.

cyber-physical system↗

Autonomous Wireless Technology Detection in Seamless IoT Applications

The ever-increasing use of Internet of Things (IoT) devices results in the implementation of multiple wireless technologies that would not only cater their data rate requirements but also support various applications. To optimize the energy efficiency and security of the wireless transmission, it is imperative to identify the wireless technologies in various IoT implementations. Many of the existing approaches are based on measuring only the receiving signal strength indicator (RSSI). However, such approaches may not work well because of transmit power control and complex channel variations among different wireless technologies. In this article, we propose an autonomous wireless detection scheme that considers multiple distinguishable physical (PHY)-layer settings for real-time identification of wireless technologies for real-time applications. Specifically, the proposed scheme relies on the PHY-layer measurements of the targeted spectrum. Transmission settings, such as bandwidth, carrier frequency, and RSSI are estimated from the raw in-phase and quadrature-phase (I/Q) measurements. In addition, a symbol-level extraction scheme is implemented to extract unique features of modulation settings. These aforementioned features are applied to a machine learning process to identify the received wireless technologies. Compared with raw I/Q measurements, the extracted features are much simplified and, thus, the machine learning classifier can be designed with a simple structure for fast processing on IoT nodes. Finally, the proposed schemes are primarily evaluated theoretically, followed by implementing them on a USRP software-defined radio (SDR)-based hardware testbed. The evaluation results demonstrate high accuracy in the real-time detection of different wireless technologies for seamless IoT applications.

42 ENGINEERING↗

Bridging Cloud and Edge Computing at NREL Using CONNECT: Cloud Optimized Networking for Next-Gen Edge Computing Technologies [Slides]

CONNECT is an innovative on-premise hardware and software solution that integrates edge and cloud computing infrastructure at NREL. Built on the AWS Greengrass middleware and leveraging the MQTT protocol, CONNECT enables real-time data streaming from IoT devices and gateways to both cloud and local services, empowering researchers to rapidly capture, analyze, and act upon edge-generated data while leveraging cloud capabilities. The platform addresses research infrastructure challenges by providing a pre-approved platform which is already configured with the correct networking and cybersecurity baselines thus eliminating procurement delays and enabling on-demand availability. CONNECT's hybrid architecture efficiently manages burstable workloads, allowing research teams to dynamically scale computational capacity, handle peak data loads, and reduce operational bottlenecks. Advanced capabilities include built-in GPU support for executing machine learning models which enables low-latency inference at the edge from models trained in the cloud. This architecture supports real-time analytics and filtering, providing a mechanism to allow only transmitting and processing high-value data. Cloud-based configuration management permits engineers to manage on-premise systems remotely, optimizing operational efficiency. By bridging edge and cloud computing, CONNECT provides NREL researchers with a flexible, scalable platform that accelerates scientific discovery while maintaining robust security and performance standards.

97 MATHEMATICS AND COMPUTING↗

Improving Cyber Situational Understanding

Effective cybersecurity operations require the ability to analyze large amounts of information to assess security risks and formulate defensive strategies against adversaries. This has become more complex in recent years as the sprawl and interconnectivity of devices grows through implementation of virtualization, cloud computing, and Internet of Things (IoT). The amount of data and analysis required for effective cybersecurity command and control decisions far exceeds humans’ capacity to perform manually. We characterize the analysis problem as cyber situational understanding. The research presented to improve cyber situational understanding focuses on vulnerability analysis and threat intelligence. Regarding vulnerabilities, entities must analyze and plan work for between thousands and tens of thousands of software vulnerabilities annually. Entities heavily use network firewalls to limit vulnerability exposure. As a result, some of these vulnerabilities permit exposure to adversarial exploitation, whereas others are inaccessible and therefore present negligible risk of exploitation. Distinguishing between high and low risk software vulnerabilities requires a deep understanding of the vulnerability, network firewall protection, and characteristics of the targeted device. This problem is solved by extracting network service features from vulnerability data features using both machine-learning and natural language processing. Then, the network firewall topology is parsed to determine which vulnerabilities are reachable by adversaries. Ultimately, a state-based safety analysis ascertains which vulnerabilities are unsafe. A related vulnerability analysis problem occurs in cybersecurity operations when associating an entity’s hardware and software assets to public vulnerability databases. Assets often reveal hardware and software through installation artifacts and network service identification, and entities store these artifacts in inventory databases. However, software and hardware vendors apply a standard Common Platform Enumeration (CPE) naming convention when publicly reporting vulnerabilities. Associating these two datasets often requires many hours to days of manual inspection. The proposed solution automates the mapping approach of human analysts using fuzzy matching techniques, natural language processing, and, ultimately, machine learning to present a small set of recommendations for mapping the two datasets. The result significantly reduces human analysis time and reduces the occurrence of false positives in vulnerability notifications. Finally, cyber threat intelligence (CTI) requires associating cyber observable artifacts, such as IP addresses, URIs, and file hashes, with cyber threat tactics, techniques, and procedures. Unfortunately, most CTI data is compartmentalized across multiple organizations and cannot be shared due to the legal and reputational risk with cyber threat being associated with the entity. The approach to solving this problem inovlves using a distributed ledger with anonymous token spending and authentication. This allows a consortium of semi-trusted entities to share the workload of curating CTI for a threat sharing community’s cooperative benefit.

Huff, Philip↗

Demonstrating Advanced Nuclear Energy Solutions for Net Zero

Background/Objectives. The aggressive goals being set by nation states, communities, and private industry for decarbonization of grid electricity, industrial heat sources, and transportation around the world are imperative to mitigating the devastating effects that we are seeing from climate change. Although many of these goals focus on accomplishments by 2035 or 2050, the decisions that we make today won’t just impact the landscape of energy systems for the next 20 or 30 years—they will shape the world’s environment for centuries to come. That means that we can’t just focus on technologies that will get us to 2050, but technologies that will withstand our energy demands over that long-ranging future. Success will require us to utilize all of the clean energy resources that we have available to meet demands for electricity, heat, and steam, and we will need energy carriers such as hydrogen that do not emit additional greenhouse gases at the point of use. Nuclear energy, ranging from technologies in service today to advanced, higher temperature and modular systems that will be in service this decade, will provide a robust complement to renewable energy resources that operate variably. Researchers across the U.S. Department of Energy laboratory complex are working to advance multiple aspects of these clean energy solutions, with many focusing on integrated energy system solutions that leverage all available clean energy assets to meet wide-ranging energy demands. Approach/Activities. Nuclear energy is a proven, zero-emission option during operation that can provide consistent, dispatchable power to meet electricity demands while also providing high-quality heat that can meet energy demands beyond the electricity sector. Energy system design should seek to maximize these assets. As a dispatchable energy source with a small land utilization footprint, nuclear energy can be collocated with renewable resources, and the smaller systems that will be deployed this decade (ranging from a few megawatts to hundreds of megawatts) can be installed right where that energy is needed. Integrated nuclear and renewable systems will enhance power grid reliability and resilience, and they will help stabilize the grid through their increasingly flexible operation. Licensing, installation, and broad adoption of these advanced nuclear energy systems are expected to progress significantly in the 2020s, but this may be longer than desired by some stakeholders wishing to implement impactful clean energy decisions today. However, one must recall that nuclear energy systems will operate for 80 or more years, as is being demonstrated by current fleet nuclear systems. The nuclear community is extremely thorough in reviewing these systems with regard to safety and security; these efforts ensure that the deployed systems will continue to provide reliable, resilient energy over that operational lifetime. That investment of time up front will ensure that we can support energy demands over the centuries to come. While advanced nuclear technologies move through this process, communities and private industry may choose to install renewable generation systems that can later be coupled to the complementary nuclear systems as they become available—thus moving closer to the net zero goals in the near term. Choosing technologies and deployment configurations that allow small modular nuclear powerhouses to be added to these “energy parks” as they become available will ensure that advanced technologies can be readily adopted to support growing demands for clean energy. Results/Lessons Learned. The primary focus of integrated energy systems (IES) research is to assess the technical and economic potential of novel multi-input, multioutput solutions that are expected to enhance energy system flexibility, reliability, and resilience as we pursue a clean energy transition. Various energy applications and product streams beyond electricity are being evaluated, ranging from generation of potable water to production of hydrogen, fertilizers, synthetic fuels, and various chemicals. In early FY23 Idaho National Laboratory (INL) will commission thermal energy generation systems that emulate nuclear fission energy input using electric heating and will allow for integrated system testing with thermal energy storage, hydrogen production via high temperature electrolysis (HTE), and power systems hardware to demonstrate operation of a clean energy park within a microgrid or larger grid infrastructure, supporting up to 450 kW of heat input via electric heating and demonstrating operation of HTE systems at the multi-hundred kW scale. This presentation will highlight the wide array of RD&D being conducted at INL and partner laboratories to develop and deploy nuclear and renewable-based IES that will be key to achieving our net zero goals, including both computational and experimental demonstrations. By working with key collaborators in industry, analytical st

08 HYDROGEN↗

SULI Research Report Paper

The Intelligence and Space Research Group 4 (ISR-4) at the Los Alamos National Laboratory focuses on signal processing and developing space electronics for various national security missions. The Space and Atmospheric Burst Reporting System (SABRS) is a sensing payload designed for nuclear detonation detection. As the sensors from previous payloads become obsolete, the requirement for a novel payload design increases. SABRS Prime is the successor to the previous SABRS payloads and is scheduled for delivery in 2028. As part of the SABRS Prompt Gamma Instrument Interface Board, high frequency signals from silicon photomultiplier tubes need to be split and subsequently transmitted to the Analog to Digital Converter. Prior to developing the Space Grade Instrument Interface Board, evaluation modules with Commercial off-the-shelf (COTS) components are evaluated and tested under rigorous conditions. Verification of power levels and gain specifications are some of the important steps taken during the evaluation stage. Working on the Signal Splitting Board has enabled me to work with various schematic software applications and learn more about the processes behind designing space grade electronic components. In addition, I conducted research on efficiency improvements for space-based power systems. Changes in design approaches were found to be the most significant sources of improvement. Being able to interact with researchers and peers across various scientific disciplines has given me a better insight into my future pursuits. Working in a R&D environment has cemented my decision to work on space applications for Quantum Sensing and pursue a PhD in Electrical Engineering. The SULI internship program at the Los Alamos National Laboratory has helped me develop the skillset of a researcher, understand the rigorous processes behind developing space grade hardware, and improve my critical thinking abilities to support the development of reliable instrumentation for deep space missions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SD-WAN Evaluation Criteria for a Defense Information Systems Network Expeditionary Customer Edge

The Defense Information Systems Agency (DISA) has identified a service provision gap midway between the capacity and capability of a Defense Information Systems Network (DISN) transport Edge Points of Presence (POP) and U.S. Department of Defense (DoD) Enterprise Classified Travel Kit (DECTK). Some deployed force 100-user Tactical Operations Centers are in field locations far removed from the DISN transport core, in challenging environmental conditions with limitations on space, weight, power, and cooling for network equipment. As part of a multi-phase project, Pacific Northwest National Laboratory (PNNL) will gather and analyze requirements, design, develop, prototype, and test a miniaturized and ruggedized DISN Customer Edge POP scaled to support approximately 100 users in a field Tactical Operations Center. An Expeditionary Customer Edge (ECE) will be more suitable for field deployment than a DISN transport Edge POP, using ruggedized hardware and network function virtualization (NFV) to operate in challenging field environmental conditions, plus reduce weight, power, and cooling requirements. A key enabling technology for ECE is Software Defined Wide Area Networking (SD-WAN). This document provides: • A brief overview of SD-WAN use cases and how they apply to ECE • How SD-WAN technology compares to existing networks like DISN that use Optical Transport Networking (OTN) and Multiprotocol Label Switching (MPLS) • SD-WAN functional requirements relevant to ECE • A description of an ECE Virtual Prototype, including simulated wide area network paths and a DISN-representative implementation of MPLS, in Cisco Modeling Labs • Detailed network flow walkthroughs • Evaluation criteria based on ECE-relevant SD-WAN functional requirements Finally, an appendix provides an informal evaluation of Speedify—a commercial retail Virtual Private Network service—against the ECE SD-WAN evaluation criteria.

42 ENGINEERING↗

Test Points for Online Monitoring of Quantum Circuits

Noisy Intermediate-Scale Quantum (NISQ) computers consisting of tens of inherently noisy quantum bits (qubits) suffer from reliability problems. Qubits and their gates are susceptible to various types of errors. Due to limited numbers of qubits and high error rates, quantum error correction cannot be applied. Physical constraints of quantum hardware including the error rates are used to guide the design and the layout of quantum circuits. The error rates determine the selection of qubits and their operations. The resulting circuit is executed on the quantum computer. This study explores the risk of unexpected changes in the error rates of NISQ computers post-calibration. We show that unexpected changes in error rates can alter the output state of a quantum circuit. To detect these changes, we propose the insertion of test points into the quantum circuit to enable online monitoring of the physical qubit behavior. We utilize classical, superposition, and uncompute test points. Furthermore, we use a gate error coverage metric to assess the quality of the tests. We verify the effectiveness of the proposed scheme on different IBM quantum computers (IBM Q), in addition to a noisy simulation that shows the scalability of the proposed approach.

97 MATHEMATICS AND COMPUTING↗

A Method for Assessing Effectiveness and Technical Capabilities Required for Integrated Deterrence (NSLP-Final Report-Draft2022)

The United States faces an ever-increasingly multi-polar security environment dominated by great power competition with China and a lingering Russian threat as well as from would-be regional hegemons led by ambitions from Iran and North Korea. Our adversaries are pursuing and expanding the strategic means by-which they have an asymmetric offset (e.g., cyber, space, and other modes below the level of armed conflict). To combat and deter against the widening range of hostile actions, the U.S. must have additional capabilities with-which to deter. All of which drives us towards a more thoughtful integrated approach to deterrence, attempting to best align deterrent tools with the adversary actions in order to maximize the credibility of our deterrent. Such an approach complicates our deterrence strategy and demands a methodology to assess whether the U.S. has the deterrent tools necessary to deter the adversarial actions most costly to the U.S. To address this complexity, we create a framework to comprehensively and systematically assess our deterrent tools as qualitatively measured against the adversarial actions we wish to deter. Deterrence is ultimately an operation in the cognitive domain and at the heart of the framework presented here is the fundamental deterrence calculus which we use as the defining measure of whether a tool will credibly deter a given action. We describe the eight levers of the deterrence calculus and distill these levers to four products that are used to qualitatively assess the overall effectiveness of deterrence tools against adversarial actions. Credibility is determined by two principal variables: the technical credibility of the deterrent tool, and the principle of proportionality. Technical credibility of realized deterrence products is assessed through development of key mission requirements and hardware (e.g., components) that will impose costs, deny benefits, or encourage restraint. The principle of proportionality qualitatively asserts that for a deterrent tool to be cognitively credible, the costs imposed against, or benefits denied by, an action are commensurate to the magnitude of costs received from the adversarial action. By basing this framework on these two fundamentals, it is possible to compare deterrent tools in a systematic approach across the broad spectrum of hostile actions.

42 ENGINEERING↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

BWR Spent Nuclear Fuel Acquisition and Testing to Support DOE-NE High Burnup Spent Fuel Data Project

The Office of Spent Fuel and Waste Disposition (SFWD) within the US Department of Energy (DOE) Office of Nuclear Energy (NE) established the Spent Fuel and Waste Science and Technology (SFWST) campaign to conduct research and development (R&D) activities related to the storage, transportation, and disposal of spent nuclear fuel (SNF) and high-level radioactive waste. The SFWST program was created within SFWD to address issues of extended or long-term SNF storage and transportation. Some near-term objectives of SFWST are to use a science-based, engineering-driven approach to: Support the enhancement of the technical bases to support the continued safe and secure dry storage of SNF for extended periods; Support the enhancement of the technical bases for retrieving SNF after extended dry storage; Support the enhancement of the technical bases for transporting high burnup (HBU) fuel and transporting low burnup fuel and HBU fuel after dry storage DOE-NE, in partnership with the Electric Power Research Institute, developed the High Burnup Spent Fuel Data Project to perform a large-scale demonstration and laboratory-scale testing of HBU pressurized water reactor (PWR) fuels (exceeding 45 gigawatt-days per metric ton of uranium [GWd/MTU]). Under this project, 25 sister rods—which are rods that have the same design, power histories, and other characteristics—were removed from assemblies at the North Anna Nuclear Power Station and sent to Oak Ridge National Laboratory (ORNL) in January 2016. ORNL performed detailed nondestructive examination (NDE) on all 25 rods. The NDE consisted of visual examinations, gamma and neutron scanning, profilometry and rod length measurements, and eddy current examinations. After completing the NDE, 10 of the sister rods were delivered to Pacific Northwest National Laboratory (PNNL) in a NAC International, Inc. legal-weight truck cask in September 2018 for destructive examination (DE). To date, SFWD work has focused on the PWR fuel that is part of the Sister Rod Test program. No boiling water reactor (BWR) fuel has been tested in the program, and the data needs that were identified for the PWR fuel have not been collected for BWR fuel. The goal to obtain six to nine BWR rods and test them at ORNL will support closing this important data gap. BWR fuel comprises approximately 56% of the total fuel assemblies currently in storage at nuclear power plants in the United States. BWR nuclear fuel and cladding designs and manufacturing are significantly different from PWRs. Differences include the following: BWR fuel pellets are larger than PWR pellets; Variations of Zircaloy-2 (including liners) are used instead of the Zircaloy-4 cladding materials used in PWRs; Clad manufacturing and stress-relief processes are different between PWRs and BWRs; The fuel rod dimensions are different because larger rod diameters and thicker cladding are used in BWRs; BWR fuel typically has lower internal rod pressures and sees vastly different operating conditions than PWR fuel (i.e., two-phase flow); BWR assemblies are “canned,” meaning each assembly is surrounded by a metal fuel channel; BWR cladding is often composed of an inner pure Zr liner that has widely different mechanical properties than the Zircaloy-2 alloy and exhibits a stronger affinity for hydrogen; The BWR SNF generally has more total hydrogen in the cladding/liner than typical PWR fuel; The construction of the PWR and BWR assemblies is vastly different; BWR rods are solidly attached to the assembly nozzles and experience a much different vibration and shock load than PWR rods, which are “floating” within a grid system attached to guide tubes, and the rods sit loosely on the bottom end plates. These numerous differences will affect the way the BWR SNF responds under dry storage preparation processes (e.g., vacuum drying) and during transportation. The results collected in the PWR experimental program must be compared with a subset of similar data collected on BWR SNF to establish a technical basis for whether the larger PWR database is sufficient to bound the BWR SNF end-of-life conditions as is currently assumed for several fuel/clad properties. Changes that occur in both fuel types at HBU could exacerbate any mechanical property differences. As the fuel burnup increases, several changes occur that might affect the performance of the fuel, cladding, and assembly hardware in storage and transportation. These changes include increased cladding corrosion layer thickness, increased cladding hydrogen content, increased cladding creep strains, increased fission gas release, and the formation of the HBU structure at the surface of the fuel pellets. The Nuclear Regulatory Commission (NRC) limits the current maximum rod-averaged burnup to 62 GWd/MTU due to these changes and the lack of data at higher burnups.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗