Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

WE-G-BRE-01: A High Power Nanotube X-Ray Microbeam Irradiator for Preclinical Brain Tumor Treatment

Purpose: Microbeam radiation therapy (MRT) is a new type of cancer treatment undergoing studies at various synchrotron facilities. The principle of MRT is using arrays of microscopically small, low-energy X-radiation for the treatment of various radio-resistant, deep-seated tumors. Our motivation is to develop a compact and inexpensive image guided MRT irradiator to use in the research lab setting. After a successful initial demonstration, here we report a second generation carbon nanotube (CNT) cathode based MRT tube, capable of producing multiple microbeam lines with an anticipated dose rate of 11 Gy/min per line. Methods: The system uses multiple line CNT source arrays to generate multiple focal lines on the anode. The increase in dose-rate, compared to our first generation system, is achieved by increasing the operating voltage from 160 kVp to 225kVp, adding multiple simultaneous focal lines on the anode, and a more efficient cooling mechanism using a 6kW oil-cooled anode. Results: This work will present the design and development process, challenges and solutions to meeting operating specifications, and the final design of the tube and collimator, along with optimization and stabilization of its use. A detailed characterization of its capabilities will be included with a comprehensive measurement of its X-ray focal line dimensions, an evaluation of its collimator alignment and microbeam dimensions, and phantom-based quantification of its dosimetric output. Conclusion: The development of a second generation, compact, multiple line MRT device using carbon nanotube (CNT) cathode based X-ray technology and a novel oil cooled anode design is presented here. With this new source, we are capable of delivering a total microbeam radiation dose comparable to the low end of the synchrotron based MRT systems for small animal brain tumor models.

60 APPLIED LIFE SCIENCES↗

Final Report on the Phase II Physics Proposal for T-1063: The Accelerator Neutrino Neutron Interaction Experiment (ANNIE)

The goal of ANNIE is to make the first detailed measurement of the number of neutrons produced by neutrinos interacting with nuclei. This measurement is important for understanding the results of previous and planned neutrino experiments, as neutrons carry away energy from the neutrino interactions that must be accounted for in determining the energy and neutrino type. This effort is also focused on using a new photodetector technology and key target material enhancements to enable advanced water-based neutrino detectors. The ANNIE detector has been installed in the Booster Neutrino Beam at Fermilab, which provides a pulsed source of neutrinos in the energy range of 300-1200 MeV, which is relevant for the next generation of neutrino experiments. In 2017-2018 measurements of the neutron background in this beam were made with a partially-instrumented ANNIE detector. These measurements guided our design of the upgraded detector now built. The upgrade has been realized by adding Large Area Picosecond Photodetectors (LAPPDs) for the first time, more conventional photomultiplier tubes (PMTs), as well as adding electronics channels to the existing data acquisition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma flow processes within magnetic nozzle configurations

An attempt is made to separate the interactive processes occurring in electromagnetic devices and to examine the acceleration of ionized gas within magnetic fields which can guide it through an expansion process. The plasma was generated in a single turn coil 50 cm long with a radius of 5.25 cm which surrounded a quartz tube with an internal radius of 3.81 cm and a length of 100 cm. Choking was found to occur at both sonic and cusp velocities which were coincident in the present experiment.

York, Thomas M.↗

New progress of ranging technology at Wuhan Satellite Laser Ranging Station

A satellite laser ranging system with an accuracy of the level of centimeter has been successfully developed at the Institute of Seismology, State Seismological Bureau with the cooperation of the Institute of Geodesy and Geophysics, Chinese Academy of Science. With significant improvements on the base of the second generation SLR system developed in 1985, ranging accuracy of the new system has been upgraded from 15 cm to 3-4 cm. Measuring range has also been expanded, so that the ETALON satellite with an orbit height of 20,000 km launched by the former U.S.S.R. can now be tracked. Compared with the 2nd generation SLR system, the newly developed system has the following improvements. A Q modulated laser is replaced by a mode-locked YAG laser. The new device has a pulse width of 150 ps and a repetition rate of 1-4 pps. A quick response photomultiplier has been adopted as the receiver for echo; for example, the adoption of the MCP tube has obviously reduced the jitter error of the transit time and has improved the ranging accuracy. The whole system is controlled by an IBM PC/XT Computer to guide automatic tracking and measurement. It can carry out these functions for satellite orbit calculation, real-time tracking and adjusting, data acquisition and the preprocessed of observing data, etc. The automatization level and reliability of the observation have obviously improved.

Xia, Zhiz-Hong↗

Investigation of temperature distribution on a new linear Fresnel receiver assembly under high solar flux

A linear Fresnel collector design with an operation temperature of 300 degrees C or above typically requires a solar flux concentration ratio of at least 20 on the surfaces of the receiver assembly. For the commercial linear Fresnel collector design in this work, the receiver assembly includes a secondary reflector and an evacuated receiver tube. The high-concentration solar flux may impose additional operating-temperature requirements on the secondary reflector and receiver tube. Thus, a careful heat-transfer analysis is necessary to understand the operating temperature of the receiver assembly component surfaces under design and off-design conditions to guide appropriate material selections. In this work, a numerical heat-transfer analysis is performed to calculate the temperature distribution of the surfaces of the secondary reflector and receiver glass envelope for a commercial collector design. Operating conditions examined in the heat-transfer analysis include various wind speeds and solar concentration ratios. The results indicate a surface temperature higher than 100 degrees C on the secondary reflector surface, which suggests that a more advanced secondary reflector material is needed. The established heat-transfer model can be used for optimization of the other types of linear Fresnel collectors.

14 SOLAR ENERGY↗

Iso-uncertainty control in an experimental fluoroscopy system

Purpose: X-ray fluoroscopy remains an important imaging modality in a number of image-guided procedures due to its real-time nature and excellent spatial detail. However, the radiation dose delivered raises concerns about its use particularly in lengthy treatment procedures (>0.5 h). The authors have previously presented an algorithm that employs feedback of geometric uncertainty to control dose while maintaining a desired targeting uncertainty during fluoroscopic tracking of fiducials. The method was tested using simulations of motion against controlled noise fields. In this paper, the authors embody the previously reported method in a physical prototype and present changes to the controller required to function in a practical setting. Methods: The metric for feedback used in this study is based on the trace of the covariance of the state of the system, tr(C). The state is defined here as the 2D location of a fiducial on a plane parallel to the detector. A relationship between this metric and the tube current is first developed empirically. This relationship is extended to create a manifold that incorporates a latent variable representing the estimated background attenuation. The manifold is then used within the controller to dynamically adjust the tube current and maintain a specified targeting uncertainty. To evaluate the performance of the proposed method, an acrylic sphere (1.6 mm in diameter) was tracked at tube currents ranging from 0.5 to 0.9 mA (0.033 s) at a fixed energy of 80 kVp. The images were acquired on a Varian Paxscan 4030A (2048 × 1536 pixels, ∼100 cm source-to-axis distance, ∼160 cm source-to-detector distance). The sphere was tracked using a particle filter under two background conditions: (1) uniform sheets of acrylic and (2) an acrylic wedge. The measured tr(C) was used in conjunction with a learned manifold to modulate the tube current in order to maintain a specified uncertainty as the sphere traversed regions of varying thickness corresponding to the acrylic sheets in the background. Results: With feedback engaged, the tracking error was found to correlate well with the specified targeting uncertainty. Tracking of the fiducial was found to be robust to changes in the attenuation presented by the varying background conditions. For a desired uncertainty of 5.0 mm, comparison of the feedback framework with a comparable system employing fixed exposure demonstrated dose savings of 29%. Conclusions: This work presents a relation between a state descriptor, tr(C), the x-ray tube current used, and an estimate of the background attenuation. This relation is leveraged to modulate the tube current in order to maintain a desired geometric uncertainty during fluoroscopy. The authors’ work demonstrates the use of the method in a real x-ray fluoroscopy system with physical motion against varying backgrounds. The method offers potential savings in imaging dose to patients and staff while maintaining tracking uncertainty during fluoroscopy-guided treatment procedures.

60 APPLIED LIFE SCIENCES↗

Multi-institutional dosimetric and geometric commissioning of image-guided small animal irradiators

Purpose: To compare the dosimetric and geometric properties of a commercial x-ray based image-guided small animal irradiation system, installed at three institutions and to establish a complete and broadly accessible commissioning procedure. Methods: The system consists of a 225 kVp x-ray tube with fixed field size collimators ranging from 1 to 44 mm equivalent diameter. The x-ray tube is mounted opposite a flat-panel imaging detector, on a C-arm gantry with 360° coplanar rotation. Each institution performed a full commissioning of their system, including half-value layer, absolute dosimetry, relative dosimetry (profiles, percent depth dose, and relative output factors), and characterization of the system geometry and mechanical flex of the x-ray tube and detector. Dosimetric measurements were made using Farmer-type ionization chambers, small volume air and liquid ionization chambers, and radiochromic film. The results between the three institutions were compared. Results: At 225 kVp, with 0.3 mm Cu added filtration, the first half value layer ranged from 0.9 to 1.0 mm Cu. The dose-rate in-air for a 40 × 40 mm{sup 2} field size, at a source-to-axis distance of 30 cm, ranged from 3.5 to 3.9 Gy/min between the three institutions. For field sizes between 2.5 mm diameter and 40 × 40 mm{sup 2}, the differences between percent depth dose curves up to depths of 3.5 cm were between 1% and 4% on average, with the maximum difference being 7%. The profiles agreed very well for fields >5 mm diameter. The relative output factors differed by up to 6% for fields larger than 10 mm diameter, but differed by up to 49% for fields ≤5 mm diameter. The mechanical characteristics of the system (source-to-axis and source-to-detector distances) were consistent between all three institutions. There were substantial differences in the flex of each system. Conclusions: With the exception of the half-value layer, and mechanical properties, there were significant differences between the dosimetric and geometric properties of the three systems. This underscores the need for careful commissioning of each individual system for use in radiobiological experiments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

AN Fitting Reconditioning Tool

A tool was developed to repair or replace AN fittings on the shuttle external tank (ET). (The AN thread is a type of fitting used to connect flexible hoses and rigid metal tubing that carry fluid. It is a U.S. military-derived specification agreed upon by the Army and Navy, hence AN.) The tool is used on a drill and is guided by a pilot shaft that follows the inside bore. The cutting edge of the tool is a standard-size replaceable insert. In the typical Post Launch Maintenance/Repair process for the AN fittings, the six fittings are removed from the ET's GUCP (ground umbilical carrier plate) for reconditioning. The fittings are inspected for damage to the sealing surface per standard operations maintenance instructions. When damage is found on the sealing surface, the condition is documented. A new AN reconditioning tool is set up to cut and remove the surface damage. It is then inspected to verify the fitting still meets drawing requirements. The tool features a cone-shaped interior at 36.5 , and may be adjusted at a precise angle with go-no-go gauges to insure that the cutting edge could be adjusted as it wore down. One tool, one setting block, and one go-no-go gauge were fabricated. At the time of this reporting, the tool has reconditioned/returned to spec 36 AN fittings with 100-percent success of no leakage. This tool provides a quick solution to repair a leaky AN fitting. The tool could easily be modified with different-sized pilot shafts to different-sized fittings.

Lopez, Jason↗

Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams

Purpose: By using Monte Carlo simulations, the authors investigated the energy and angular dependence of the response of plastic scintillation detectors (PSDs) in photon beams. Methods: Three PSDs were modeled in this study: A plastic scintillator (BC-400) and a scintillating fiber (BCF-12), both attached by a plastic-core optical fiber stem, and a plastic scintillator (BC-400) attached by an air-core optical fiber stem with a silica tube coated with silver. The authors then calculated, with low statistical uncertainty, the energy and angular dependences of the PSDs' responses in a water phantom. For energy dependence, the response of the detectors is calculated as the detector dose per unit water dose. The perturbation caused by the optical fiber stem connected to the PSD to guide the optical light to a photodetector was studied in simulations using different optical fiber materials. Results: For the energy dependence of the PSDs in photon beams, the PSDs with plastic-core fiber have excellent energy independence within about 0.5% at photon energies ranging from 300 keV (monoenergetic) to 18 MV (linac beam). The PSD with an air-core optical fiber with a silica tube also has good energy independence within 1% in the same photon energy range. For the angular dependence, the relative response of all the three modeled PSDs is within 2% for all the angles in a 6 MV photon beam. This is also true in a 300 keV monoenergetic photon beam for PSDs with plastic-core fiber. For the PSD with an air-core fiber with a silica tube in the 300 keV beam, the relative response varies within 1% for most of the angles, except in the case when the fiber stem is pointing right to the radiation source in which case the PSD may over-response by more than 10%. Conclusions: At {+-}1% level, no beam energy correction is necessary for the response of all three PSDs modeled in this study in the photon energy ranges from 200 keV (monoenergetic) to 18 MV (linac beam). The PSD would be even closer to water equivalent if there is a silica tube around the sensitive volume. The angular dependence of the response of the three PSDs in a 6 MV photon beam is not of concern at 2% level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Retention and Safety of Percutaneously Implanted Endovascular Embolization Coils as Fiducial Markers for Image-Guided Stereotactic Ablative Radiotherapy of Pulmonary Tumors

Purpose: To compare the retention rates of two types of implanted fiducial markers for stereotactic ablative radiotherapy (SABR) of pulmonary tumors, smooth cylindrical gold 'seed' markers ('seeds') and platinum endovascular embolization coils ('coils'), and to compare the complication rates associated with the respective implantation procedures. Methods and Materials: We retrospectively analyzed the retention of percutaneously implanted markers in 54 consecutive patients between January 2004 and June 2009. A total of 270 markers (129 seeds, 141 coils) were implanted in or around 60 pulmonary tumors over 59 procedures. Markers were implanted using a percutaneous approach under computed tomography (CT) guidance. Postimplantation and follow-up imaging studies were analyzed to score marker retention relative to the number of markers implanted. Markers remaining near the tumor were scored as retained. Markers in a distant location (e.g., pleural space) were scored as lost. CT imaging artifacts near markers were quantified on radiation therapy planning scans. Results: Immediately after implantation, 140 of 141 coils (99.3%) were retained, compared to 110 of 129 seeds (85.3%); the difference was highly significant (p < 0.0001). Of the total number of lost markers, 45% were reported lost during implantation, but 55% were lost immediately afterwards. No additional markers were lost on longer-term follow-up. Implanted lesions were peripherally located for both seeds (mean distance, 0.33 cm from pleural surface) and coils (0.34 cm) (p = 0.96). Incidences of all pneumothorax (including asymptomatic) and pneumothorax requiring chest tube placement were lower in implantation of coils (23% and 3%, respectively) vs. seeds (54% and 29%, respectively; p = 0.02 and 0.01). The degree of CT artifact was similar between marker types. Conclusions: Retention of CT-guided percutaneously implanted coils is significantly better than that of seed markers. Furthermore, implanting coils is at least as safe as implanting seeds. Using coils should permit implantation of fewer markers and require fewer repeat implantation procedures owing to lost markers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided, Ethanol Sympatholysis for Primary Axillary–Palmar Hyperhidrosis

PurposePrimary hyperhidrosis is an excessive sweating due to an overactive sympathetic system. Our objective was to test the feasibility and provide early data on the safety/efficacy of CT-guided sympatholysis, for primary hyperhidrosis.Materials and MethodsNine consecutive patients with axillary–palmar hyperhidrosis were treated between 2013 and 2015. CT-guided sympathetic block was performed in the outpatients at T-2, T-3, and T-4, bilaterally using alcohol under local anesthesia. Immediate postprocedure CT was obtained to assess the complications as per Common Terminology Criteria for Adverse Events, version 4. Technical success and clinical success were recorded. Primary and secondary efficacy were assessed by phone and clinical visits; mean follow-up was 12 months (6–26 months). Descriptive statistics was used to report the outcomes.ResultsOne procedure was aborted due to eyelid ptosis after lidocaine injection. All other eight patients (5:3, F:M) (median age 32) had immediate cessation of sweating. Two major complications (pneumothorax, one requiring a chest tube) occurred. Two patients recurred with unilateral and one with bilateral symptoms. One of the unilateral recurrence and the bilateral recurrence patients was retreated successfully. Median follow-up was 1 year. No cases of Horner’s or compensatory hyperhidrosis were observed.ConclusionsCT-guided EtOH sympatholysis for axillary/palmar primary hyperhidrosis is feasible. Technical failure rate was 11 %. Primary and secondary efficacy are 75 and 94 %, respectively, to a median follow-up of 1 year. Risk profile appears favorable. Despite a small sample size, results confirm feasibility and encourage a larger study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two Phase Flow Modeling: Summary of Flow Regimes and Pressure Drop Correlations in Reduced and Partial Gravity

The purpose of this report is to provide a summary of state-of-the-art predictions for two-phase flows relevant to Advanced Life Support. We strive to pick out the most used and accepted models for pressure drop and flow regime predictions. The main focus is to identify gaps in predictive capabilities in partial gravity for Lunar and Martian applications. Following a summary of flow regimes and pressure drop correlations for terrestrial and zero gravity, we analyze the fully developed annular gas-liquid flow in a straight cylindrical tube. This flow is amenable to analytical closed form solutions for the flow field and heat transfer. These solutions, valid for partial gravity as well, may be used as baselines and guides to compare experimental measurements. The flow regimes likely to be encountered in the water recovery equipment currently under consideration for space applications are provided in an appendix.

Balasubramaniam, R.↗

Muon Beam Dynamics and Spin Dynamics in the g-2 Storage Ring

The goal of the new g-2 experiment at fermilab is a measurement of the anomalous magnetic moment of the muon, with uncertainty of less than 140 ppb. The experimental method is to store a beam of polarized muons in a storage ring with pure vertical dipole field and electrostatic focusing, and to measure the precession frequency. Control of the systematics depends on unprecedented knowledge of the details of the phase space of the muon distribution. That knowledge is derived from direct measurements with scintillating fiber detectors that are inserted into the muon beam for diagnostic measurements, traceback straw tube tracking chambers, as well as the calorimeters that measure energy, time and position of the decay positrons. The interpretation of the measurements depends on a detailed model of the storage ring guide field. This invited talk presents results of studies of the distribution from the commissioning run of the experiment.

43 PARTICLE ACCELERATORS↗

TU-E-TOUR-I-00: Exhibit Hall Guided Tours-Dosimters for QC in Diagnostic Imaging (Tuesday)

Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Christina Sammet, Lurie Children’s Hospital of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-C-TOUR-I-00: Exhibit Hall Guided Tours-Dosimters for QC in Diagnostic Imaging (Wednesday)

Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Adrien Sanchez, University of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-C-TOUR-I-01: Dosimters for QC in Diagnostic Imaging

Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Adrien Sanchez, University of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Review of Slow-Wave Structures

The majority of recent theoretical and experimental reports published in the literature dealing with helical slow-wave structures focus on the dispersion characteristics and their effects due to the finite helix wire thickness and attenuation, dielectric loading, metal loading, and the introduction of plasma. In many papers, an effective dielectric constant is used to take into account helix wire dimensions and conductivity losses, while the propagation constant of the signal and the interaction impedance of the structure are found to depend on the surface resistivity of the helix. Also, various dielectric supporting rods are simulated by one or several uniform cylinders having an effective dielectric constant, while metal vane loading and plasma effects are incorporated in the effective dielectric constant. The papers dealing with coupled cavities and folded or loaded wave guides describe equivalent circuit models, efficiency enhancement, and the prediction of instabilities for these structures. Equivalent circuit models of various structures are found using computer software programs SUPERFISH and TOUCHSTONE. Efficiency enhancement in tubes is achieved through dynamic velocity and phase adjusted tapers using computer techniques. The stability threshold of unwanted antisymmetric and higher order modes is predicted using SOS and MAGIC codes and the dependence of higher order modes on beam conductance, section length, and effective Q of a cavity is shown.

Wallett, Thomas M.↗