Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Model Year 2017 Fuel Economy Guide: EPA Fuel Economy Estimates

The Fuel Economy Guide is published by the U.S. Department of Energy as an aid to consumers considering the purchase of a new vehicle. The Guide lists estimates of miles per gallon (mpg) for each vehicle available for the new model year. These estimates are provided by the U.S. Environmental Protection Agency in compliance with Federal Law. By using this Guide, consumers can estimate the average yearly fuel cost for any vehicle. The Guide is intended to help consumers compare the fuel economy of similarly sized cars, light duty trucks and special purpose vehicles.

biodiesel↗

Model Year 2018 Fuel Economy Guide: EPA Fuel Economy Estimates

The Fuel Economy Guide is published by the U.S. Department of Energy as an aid to consumers considering the purchase of a new vehicle. The Guide lists estimates of miles per gallon (mpg) for each vehicle available for the new model year. These estimates are provided by the U.S. Environmental Protection Agency in compliance with Federal Law. By using this Guide, consumers can estimate the average yearly fuel cost for any vehicle. The Guide is intended to help consumers compare the fuel economy of similarly sized cars, light duty trucks and special purpose vehicles.

biodiesel↗

Theory Guided Fine‐Tune of Strain Effects in Pt Ternary Alloy via Rare Earth Templating: Achieving High Performance PEMFCs Catalysts

The sluggish kinetics and insufficient durability of platinum-based catalysts remain crucial barriers limiting proton-exchange-membrane fuel cells (PEMFCs) deployment. Here, we report a theory-guided synthesis combined with rare-earth templating to realize a previously inaccessible Pt 5 Co-like phase with tailored atomic-scale strain. Guided by density functional theory (DFT) calculations, we identified that a Pt 5 Co-like sublayer can induce a unique mild compressive strain (−1.24%) to the Pt(111) shell and an optimal *OH binding energy shift (ΔE ≈ 0.11 eV). This shift positions the alloy catalyst near the apex of the oxygen reduction reaction activity volcano. This prediction guided the synthesis of ternary alloy Pt 5 (Ce)Co@Pt multilayer nanoparticles, featuring a Ce-stabilized core, a Pt 5 Co-like sublayer, and a Pt-rich shell. This catalyst demonstrates both exceptionally high activity and durability, achieving a mass activity of 2.6 A∙mg Pt −1 in rotating disk electrode testing. In fuel cell membrane electrode assembly tests, Pt 5 (Ce)Co@Pt achieves a current density of 1.9 A∙cm −2 at 0.7 V under heavy-duty vehicle conditions. Remarkably, it maintains 1.2 A∙cm −2 after 1 80 000 AST cycles, doubling the U.S. DOE 2025 target. This work demonstrates a rational design strategy that DFT-guided strain engineering integrates with rare-earth templating to advance Pt-based catalysts for fuel cell applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree; Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Signal-Inducing Bone Cement for Magnetic Resonance Imaging-Guided Spinal Surgery Based on Hydroxyapatite and Polymethylmethacrylate

The aim of this study was to develop a signal-inducing bone cement for magnetic resonance imaging (MRI)-guided cementoplasty of the spine. This MRI cement would allow precise and controlled injection of cement into pathologic lesions of the bone. We mixed conventional polymethylmethacrylate bone cement (PMMA; 5 ml methylmethacrylate and 12 g polymethylmethacrylate) with hydroxyapatite (HA) bone substitute (2-4 ml) and a gadolinium-based contrast agent (CA; 0-60 {mu}l). The contrast-to-noise ratio (CNR) of different CA doses was measured in an open 1.0-Tesla scanner for fast T1W Turbo-Spin-Echo (TSE) and T1W TSE pulse sequences to determine the highest signal. We simulated MRI-guided cementoplasty in cadaveric spines. Compressive strength of the cements was tested. The highest CNR was (1) 87.3 (SD 2.9) in fast T1W TSE for cements with 4 {mu}l CA/ml HA (4 ml) and (2) 60.8 (SD 2.4) in T1W TSE for cements with 1 {mu}l CA/ml HA (4 ml). MRI-guided cementoplasty in cadaveric spine was feasible. Compressive strength decreased with increasing amounts of HA from 46.7 MPa (2 ml HA) to 28.0 MPa (4 ml HA). An MRI-compatible cement based on PMMA, HA, and CA is feasible and clearly visible on MRI images. MRI-guided spinal cementoplasty using this cement would permit direct visualization of the cement, the pathologic process, and the anatomical surroundings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 {+-} 9 min in the gadolinium-enhanced saline solution group and 22 {+-} 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients

PurposeTo assess the scope and determining risk factors related to the development of pneumothorax throughout CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques and the outcome of its management.Materials and MethodsThe study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD 5.2) from November 2008 to June 2013 in a retrospective design. Patients were classified according to lung biopsy technique into coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension, or refusal of the procedure. Risk factors related to the occurrence of pneumothorax were classified into: (a) Technical risk factors, (b) patient-related risk factors, and (c) lesion-associated risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher’s exact tests were used for statistical analysis. p values <0.05 were considered statistically significant.ResultsThe incidence of pneumothorax complicating CT-guided lung biopsy was less in the non-coaxial group (23.2 %, 77 out of 332) than the coaxial group (27 %, 86 out of 318). However, the difference in incidence between both groups was statistically insignificant (p = 0.14). Significant risk factors for the development of pneumothorax in both groups were emphysema (p < 0.001 in both groups), traversing a fissure with the biopsy needle (p value 0.005 in non-coaxial group and 0.001 in coaxial group), small lesion, less than 2 cm in diameter (p value of 0.02 in both groups), location of the lesion in the basal or mid sections of the lung (p = 0.003 and <0.001 in non-coaxial and coaxial groups, respectively), and increased needle track path within the lung tissue of more than 2.5 cm (p = 0.01 in both groups). The incidence of pneumothorax in the non-coaxial group was significantly correlated to the number of specimens obtained (p = 0.006). This factor was statistically insignificant in the coaxial group (p = 0.45). The biopsy yield was more diagnostic and conclusive in the coaxial group in comparison to the non-coaxial group (p = 0.008). Simultaneous incidence of pneumothorax and pulmonary hemorrhage was 27.3 % (21/77) in non-coaxial group and in 30.2 % (26/86) in coaxial group. Conservative management was sufficient for treatment of 91 out of 101 patients of pneumothorax in both groups (90.1 %). Manual evacuation of pneumothorax was efficient in 44/51 patients (86.3 %) in both groups and intercostal chest tube was applied after failure of manual evacuation (7 patients: 13.7 %), from which one patient developed a persistent air leakage necessitating pleurodesis.ConclusionPneumothorax complicating CT-guided core biopsy of pulmonary lesions, showed the insignificant difference between coaxial and non-coaxial techniques. However, both techniques have the same significant risk factors including small and basal lesions, increased lesion’s depth from pleural surface, and increased length of aerated lung parenchyma crossed by biopsy needle and passing through pulmonary fissures in the needle tract.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Intraoperative Nerve Monitoring in Preventing Thermal Damage to the “Nerve at Risk” During Image-Guided Ablation of Tumors

PurposeTo assess feasibility of intraoperative neurophysiologic monitoring (IONM) during image-guided, percutaneous thermal ablation of tumors.Materials and MethodsFrom February 2009 to October 2013, a retrospective review of all image-guided percutaneous thermal ablation interventions using IONM was performed and data was compiled using electronic medical records and imaging studies.ResultsTwelve patients were treated in 13 ablation interventions. In 4 patients, real-time feedback from the monitoring neurologist was used to adjust applicator placement and ablation settings. IONM was technically feasible in all procedures and there were no complications related to monitoring or ablation. All nerves at risk remained intact and of the 11 patients who could be followed, none developed new nerve deficit up to a minimum of 2 months after ablation.ConclusionIONM is safe and feasible for use during image-guided thermal ablation of tumors in the vicinity of nerves. Outcomes in this study demonstrate its potential utility in image-guided ablation interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization with a Mixture of Absolute Ethanol and Iodized Oil for Poorly Visualized Endophytic Renal Masses Prior to CT-Guided Percutaneous Cryoablation

PurposeTo retrospectively evaluate the feasibility of transcatheter arterial embolization (TAE) using a mixture of absolute ethanol and iodized oil to improve localization of endophytic renal masses on unenhanced computed tomography (CT) prior to CT-guided percutaneous cryoablation (PCA).Materials and MethodsOur institutional review board approved this retrospective study. From September 2011 to June 2015, 17 patients (mean age, 66.8 years) with stage T1a endophytic renal masses (mean diameter, 26.5 mm) underwent TAE using a mixture of absolute ethanol and iodized oil to improve visualization of small and endophytic renal masses on unenhanced CT prior to CT-guided PCA. TAE was considered successful that accumulated iodized oil depicted whole of the tumor edge on CT. PCA was considered successful when the iceball covered the entire tumor with over a 5 mm margin. Oncological and renal functional outcomes and complications were also evaluated.ResultsTAE was successfully performed in 16 of 17 endophytic tumors. The 16 tumors were performed under CT-guided PCA with their distinct visualization of localization and safe ablated margin. During the mean follow-up period of 15.4 ± 5.1 months, one patient developed local recurrence. Estimated glomerular filtration rate declined by 8 % with statistical significance (P = 0.01). There was no procedure-related significant complication.ConclusionTAE using a mixture of absolute ethanol and iodized oil to improve visualization of endophytic renal masses facilitated tumor localization on unenhanced CT, permitting depiction of the tumor edge as well as a safe margin for ablation during CT-guided PCA, with an acceptable decline in renal function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring

PurposeRadiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions.Materials and MethodsMedical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1–5th months: Staff did not receive feedback (n = 701) and (2) 6–8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose.ResultsPersonalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04–0.50) µSv/Gy cm{sup 2} versus (phase 2) 0.08 (0.02–0.24) µSv/Gy cm{sup 2}, p = 0.002].ConclusionPersonalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Carbon dioxide Angiography-Guided Renal-Related Interventions in Patients with Takayasu Arteritis and Renal Insufficiency

BackgroundUse of iodinated contrast agents for angiography in patients with renal insufficiency risks further deterioration of renal function and its adverse sequelae.ObjectiveTo study the effectiveness and safety of carbon dioxide (CO{sub 2}) angiography in guiding percutaneous renal-related interventions in patients with Takayasu arteritis and renal insufficiency.MethodsData on CO{sub 2} angiography-guided interventions were obtained from a 23-year database of 692 Takayasu arteritis patients who underwent percutaneous interventions and were analyzed retrospectively. Follow-up data were also obtained. The CO{sub 2} angiography system used was developed in-house and was pressure-driven.ResultsSeven patients (6 female, age 16–59 years, baseline serum creatinine 1.62–4.55 mg/dl, estimated glomerular filtration rate 12.2–36.9 ml/min/1.73 m{sup 2}) underwent CO{sub 2} angiography-guided interventions: five underwent angioplasty or stenting to treat six stenotic/occluded renal arteries, one underwent extensive endovascular repair for spontaneous focal abdominal aortic dissection with false lumen aneurysm and aorto-iliac true lumen narrowing, and one underwent balloon dilatation of previously deployed aortic stents used to treat aortic occlusion at two levels. Follow-up (median 5 years, range 2 months–16 years) was obtained in all patients. All the procedures were successful and resulted in relief of symptoms, better blood pressure control, improvement in left ventricular systolic function and recovery or stabilization of renal function. There were no early or late complications related to CO{sub 2} angiography. Three renal lesions that had restenosis at follow-up were managed successfully by repeat intervention.ConclusionCO{sub 2} angiography-guided renal-related interventions are effective and safe in patients with Takayasu arteritis and renal insufficiency; they significantly improve the care of such patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Percutaneous Needle Biopsy in Patients with Suspected Retroperitoneal Fibrosis: A Retrospective Cohort Study

Purpose: The outcome of CT-guided biopsy in patients with suspected retroperitoneal fibrosis (RF), regarded as technically challenging, remains unclear. This study aimed to evaluate the results of CT-guided biopsy in patients with lesions considered in the differential diagnosis of RF and compare them with results from patients with other retroperitoneal lesions. Materials and Methods: Patients who underwent CT-guided biopsy of retroperitoneal lesions between January 2010 and September 2018 were retrospectively reviewed. The study cohort with retroperitoneal lesions surrounding the infra-abdominal aorta, iliac vessels, and/or ureters was divided into two groups: Group F included patients with lesions for which RF was considered in the differential diagnosis, and Group C comprised patients with a retroperitoneal mass or lymphadenopathy. Lesion size and depth, and biopsy details including technical success, position, procedure time, diagnostic yield, and complications between the two groups were compared. Results: Group F included 27 patients (mean age 68.5 years ± 11.6, 17 male) and Group C 30 patients (mean age 65.0 years ± 11.8, 16 male). The short axis was significantly smaller in Group F than in Group C (19 mm vs 26 mm, P = 0.041), and procedure time was significantly longer in Group F than in Group C (31.5 min ± 13.2 vs 20.3 min ± 8.4, P = 0.001). Technical success rate (93% vs 100%), accuracy (93% vs 93%), and complications (3.7% vs 10%) between Groups F and C were not significantly different. Conclusions: CT-guided biopsy of patients with suspected RF is considered safe and effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In situ characterization of the biological performance of a Francis turbine retrofitted with a modular guide vane

There are two strategies to lower overall project costs to an extent that will make many potential sustainable hydropower sites economically viable: (1) design standardized/modular components; (2) use advanced tools to reduce environmental evaluation costs. In this study an autonomous sensor device (Sensor Fish) was used to study a Francis turbine retrofitted with a modular guide vane. The median nadir pressures measured were 74.7, 66.6, and 56.6 kPaA for 90-, 190-, and 380-kW operating conditions respectively. These nadir pressures were compared to other Francis turbines studied using Sensor Fish and were found to be within the same range. The proportion of Sensor Fish releases with severe acceleration events (acceleration = 95G) was also investigated. The proportion ranged from 73 to 80% (runner region), 50 to 64% (guide vane region), and 9 to 28% (draft tube region), which was within the range of the other turbines used for comparison. The Sensor Fish testing that was conducted at Hurley Dam demonstrates that the modular guide vane that was retrofitted to the existing Francis turbine is potentially a suitable replacement that can provide biological performance similar to the guide vane used with other existing Francis turbines, but with the benefit of reduced fabrication costs.

13 HYDRO ENERGY↗

On-Board Imaging Validation of Optically Guided Stereotactic Radiosurgery Positioning System for Conventionally Fractionated Radiotherapy for Paranasal Sinus and Skull Base Cancer

Purpose: To evaluate the positioning accuracy of an optical positioning system for stereotactic radiosurgery in a pilot experience of optically guided, conventionally fractionated, radiotherapy for paranasal sinus and skull base tumors. Methods and Materials: Before each daily radiotherapy session, the positioning of 28 patients was set up using an optical positioning system. After this initial setup, the patients underwent standard on-board imaging that included daily orthogonal kilovoltage images and weekly cone beam computed tomography scans. Daily translational shifts were made after comparing the on-board images with the treatment planning computed tomography scans. These daily translational shifts represented the daily positional error in the optical tracking system and were recorded during the treatment course. For 13 patients treated with smaller fields, a three-degree of freedom (3DOF) head positioner was used for more accurate setup. Results: The mean positional error for the optically guided system in patients with and without the 3DOF head positioner was 1.4 {+-} 1.1 mm and 3.9 {+-} 1.6 mm, respectively (p <.0001). The mean positional error drifted 0.11 mm/wk upward during the treatment course for patients using the 3DOF head positioner (p = .057). No positional drift was observed in the patients without the 3DOF head positioner. Conclusion: Our initial clinical experience with optically guided head-and-neck fractionated radiotherapy was promising and demonstrated clinical feasibility. The optically guided setup was especially useful when used in conjunction with the 3DOF head positioner and when it was recalibrated to the shifts using the weekly portal images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved guided-wave acoustic defect detection and localization in pipes under varying temperature conditions using deep learning

Early defect detection in pipelines is critical across industries, particularly in the oil and gas sector, where failures result in significant maintenance costs and operational disruptions. Acoustic guided-wave techniques are widely used for nondestructive evaluation of pipeline defects due to their long-distance propagation capability. However, environmental variations, sensitivity limitations, and complex signal interpretation challenges limit the effectiveness of traditional signal processing approaches with guided-wave signals. Recent advances in deep learning methods have demonstrated remarkable success in solving complex real-world problems in many fields. In particular, deep-learning-based signal processing holds substantial promise to overcome limitations and challenges of conventional signal processing. This study presents a deep learning framework for pipeline inspection using acoustic guided-wave signals under temperature varying environments. The proposed framework employs a dual-path one-dimensional convolutional autoencoder that combines defect detection, localization, and temperature prediction functions. The proposed system utilizes multi-mode and broadband acoustic waves with an optimized number of sensors that provide high accuracy while retaining practical simplicity. Experimental validation is performed on a carbon steel pipe. The results indicate exceptional defect detection accuracy and precise defect localization with a mean absolute error of 66 mm. The proposed technique also predicts the effective average temperature of the pipe with a mean absolute error of 0.2°C. Comparative analysis shows superior performance of the proposed method over a traditional method previously developed by the authors' team. These results highlight the potential of integrating deep learning methods into guided-wave pipeline inspection systems to improve reliability under varying environmental conditions.

42 ENGINEERING↗

Calculation of collisionless pitch-angle scattering of runaway electrons with synchrotron radiation via high-order guiding-centre equation

Recently, the collisionless pitch-angle scattering for relativistic runaway electrons (REs) in toroidal geometries such as tokamaks was discovered through a full orbit simulation approach (Liu et al., Nucl. Fusion, vol. 56, 2016, p. 064002), and it was then theoretically investigated that a new expression for the magnetic moment, including the second-order corrections, could essentially reproduce the so-called collisionless pitch-angle scattering process (Liu et al., Nucl. Fusion, vol. 58, 2018, p. 106018). In this paper, with synchrotron radiation, extensive numerical verification of the validity of the high-order guiding-centre theory is given for simulations involving REs by incorporating such an expression for the magnetic moment into our particle tracing code. A high-order guiding-centre simulation approach with synchrotron radiation (HGSA) is applied. Synchrotron radiation plays an essential role in the life cycle of REs. The energy of REs first increases and then becomes saturated until the electric field acceleration is balanced by the radiation dissipation. Unfortunately, the process cannot be simulated accurately with the standard guiding-centre model, i.e. the first-order guiding-centre model. Remarkably, it is found that the HGSA can effectively produce the fundamental process of REs. Since the time scale of the energy saturation of REs is close to seconds, the computational cost becomes significant. In order to save costs, it is necessary to estimate the time of energy saturation. An analytical estimate is derived for the time it takes for synchrotron drag to balance an accelerating electric field and the provided formula has been numerically verified. Finally, test calculations reveal that HGSA is favourable for exploiting the dynamics of REs in tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗