An Upgrade of the Aeroheating Software ''MINIVER''

Detailed computational modeling: CFO often used to create and execute computational domains. Increasing complexity when moving from 20 to 30 geometries. Computational time increased as finer grids are used (accuracy). Strong tool, but takes time to set up and run. MINIVER: Uses theoretical and empirical correlations. Orders of magnitude faster to set up and run. Not as accurate as CFO, but gives reasonable estimations. MINIVER's Drawbacks: Rigid command-line interface. Lackluster, unorganized documentation. No central control; multiple versions exist and have diverged.

Louderback, Pierce↗

Regulatory and Technical Challenges and Barriers to Adoption of Distributed Wind Energy in Agricultural Settings

Distributed wind (DW) energy development can benefit agricultural landowners through the possibility of improved resilience of electrical service from onsite generation and associated economic benefits. DW development currently faces technical and regulatory challenges related to interconnection of projects with distribution or transmission equipment on the main electrical grid. A review was conducted of barriers to adoption for agricultural DW projects and potential roles of various stakeholders in addressing them. One major barrier is that the unique characteristics of wind energy generation such as its variability and intermittency, may require upgrades for the whole power line, which can lead to prohibitive cost burdens on individual interconnection customers. Another barrier is compliance with federal, state, or utility-level regulations that require technology-agnostic, industry-standard equipment that is often not technically realistic for DW projects. DW developers, grid infrastructure owner-operators, regulators, and standards publishers can work together to address these challenges and facilitate DW development.

17 WIND ENERGY↗

Kinetic particle simulations in a global toroidal geometry

The gyrokinetic toroidal code has been upgraded for global simulations by coupling the core and scrape-off layer regions across the separatrix with field-aligned particle-grid interpolations. A fully kinetic particle pusher for high frequency waves (ion cyclotron frequency and beyond) and a guiding center pusher for low frequency waves have been implemented using cylindrical coordinates in a global toroidal geometry. The two integrators correctly capture the particle orbits and agree well with each other, conserving energy and canonical angular momentum. As a verification and application of this new capability, ion guiding center simulations have been carried out to study ion orbit losses at the edge of the DIII-D tokamak for single null magnetic separatrix discharges. The ion loss conditions are examined as a function of the pitch angle for cases without and with a radial electric field. We report the simulations show good agreement with past theoretical results and with the experimentally observed feature in which high energy ions flow out along the ion drift orbits and then hit the divertor plates. A measure of the ion direct orbit loss fraction shows that the loss fraction increases with the ion energy for DIII-D in the initial velocity space. Finally, as a further verification of the capability of the new code, self-consistent simulations of zonal flows in the core region of the DIII-D tokamak were carried out. All DIII-D simulations were performed in the absence of turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beta Test Plan for Advanced Inverters Interconnecting Distributed Resources with Electric Power Systems

This document provides a preliminary (beta) test plan for grid interconnection systems of advanced inverter-based DERs. It follows the format and methodology/approach established by IEEE Std 1547.1, while incorporating: 1. Upgraded tests for responses to abnormal voltage and frequency, and also including ride-through. 2. A newly developed test for voltage regulation, including dynamic response testing. 3. Modified tests for unintentional islanding, open phase, and harmonics to include testing with the advanced voltage and frequency response functions enabled. Two advanced inverters, one single-phase and one three-phase, were tested under the beta test plan. These tests confirmed the importance of including tests for inverter dynamic response, which varies widely from one inverter to the next.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Service-Oriented Architecture for NVO and TeraGrid Computing

The National Virtual Observatory (NVO) Extensible Secure Scalable Service Infrastructure (NESSSI) is a Web service architecture and software framework that enables Web-based astronomical data publishing and processing on grid computers such as the National Science Foundation's TeraGrid. Characteristics of this architecture include the following: (1) Services are created, managed, and upgraded by their developers, who are trusted users of computing platforms on which the services are deployed. (2) Service jobs can be initiated by means of Java or Python client programs run on a command line or with Web portals. (3) Access is granted within a graduated security scheme in which the size of a job that can be initiated depends on the level of authentication of the user.

Jacob, Joseph↗

Hydropower Role in a Power Grid with a High Proportion of Variable Renewables

The importance of hydropower increases as the power grid evolves with the higher variable renewable contribution. As conventional thermal power plants are retired, the importance of hydropower contribution increases to balance the variability of solar and wind generation. However, reservoir water resources are constrained by multiple constraints, and variability of water inflow to the reservoirs creates limitations to dam water releases for power grid needs. Coordination of multiple tools, including water resources modeling, ecological modeling, and technical and economic power grid modeling, informs dam water releases. Better representation of ecological constraints and other water use details in the suit of power grid models are required to identify the hydropower flexibility to provide multiple power grid services. Impacts of water planning and hydropower operation changes to a power grid are better understood by production cost model simulations with technical and economic data, including unserved energy, reserve failures, transmission congestion to serve load, and local marginal price increases. Similarly, PCM simulation of current and future projected power grid information, including LMP, and carbon emission rates, informs short-term water release plans and long-term investments for power plant upgrades for technical and ecological needs. Hydropower operations of several case studies are simulated to understand operation patterns, revenue, water release decisions in multiple time scales (month, day, minutes), hydropower contracts scheduling, and water variability impacts.

environmental↗

High Penetration Microgrids Providing Grid Stability Using Frequency-Watt Control Presentation

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint.Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

13 HYDRO ENERGY↗

The Wind Forecast Improvement Project (WFIP): A Public–Private Partnership Addressing Wind Energy Forecast Needs

The Wind Forecast Improvement Project (WFIP) is a public–private research program, the goal of which is to improve the accuracy of short-term (0–6 h) wind power forecasts for the wind energy industry. WFIP was sponsored by the U.S. Department of Energy (DOE), with partners that included the National Oceanic and Atmospheric Administration (NOAA), private forecasting companies (WindLogics and AWS Truepower), DOE national laboratories, grid operators, and universities. WFIP employed two avenues for improving wind power forecasts: first, through the collection of special observations to be assimilated into forecast models and, second, by upgrading NWP forecast models and ensembles. The new observations were collected during concurrent year-long field campaigns in two high wind energy resource areas of the United States (the upper Great Plains and Texas) and included 12 wind profiling radars, 12 sodars, several lidars and surface flux stations, 184 instrumented tall towers, and over 400 nacelle anemometers. Results demonstrate that a substantial reduction (12%–5% for forecast hours 1–12) in power RMSE was achieved from the combination of improved numerical weather prediction models and assimilation of new observations, equivalent to the previous decade’s worth of improvements found for low-level winds in NOAA/National Weather Service (NWS) operational weather forecast models. Data-denial experiments run over select periods of time demonstrate that up to a 6% improvement came from the new observations. Ensemble forecasts developed by the private sector partners also produced significant improvements in power production and ramp prediction. Based on the success of WFIP, DOE is planning follow-on field programs.

17 WIND ENERGY↗

Facilitating the Portability of User Applications in Grid Environments

Grid computing promises the ability to connect geographically and organizationally distributed resources to increase effective computational power, resource utilization, and resource accessibility. For grid computing to be successful, however, users must be able to easily execute the same application on different resources. Different resources, however, may be administered by different organizations with different software installed, different file system structures, and different default environment settings. Even within the same organization, the set of software installed on a given resource is in constant flux with additions, upgrades, and removals. Users cannot be expected to understand all of the idiosyncrasies of each resource they may wish to execute jobs on, thus must be provided with automated assistance. This paper describes a new OGSI-compliant grid service (the Portability Manager) that has been implemented as part of NASA's Information Power Grid (IPG) project to automatically estab!ish the execution environment for user applications.

Kolano, Paul Z.↗

Field testing and validation of a low-cost MPC for demand flexibility for grid-interactive K-12 schools

K-12 school buildings account for the highest energy consumption within the public sector. Implementing advanced HVAC controls in grid-interactive K-12 schools could bring substantial economic advantages and grid flexibility. Our previous study demonstrated that a low-cost model predictive control (MPC) solution, which coordinates multiple packaged units, can enable demand flexibility without major hardware upgrades. However, a significant gap remains between academic pilots and market-ready scalable solutions. This paper extends the previous single-site pilot to a multi-site demonstration involving three school campuses (95 total units) through a commercial technology transfer process. Addressing the challenge of verifying performance with sparse field data, we present a new statistical approach using Bayesian methods to estimate the MPC’s effect on peak demand. Unlike traditional methods, this approach robustly quantifies uncertainty in non-normal, limited datasets. The results confirm the solution’s replicability, achieving a 21.6–38.9% reduction in HVAC peak demand (10.8–22.1% at the site-level) with > 98% probability across diverse locations. Finally, we document critical barriers to scaling software-as-a-service (SaaS) solutions–such as API instability and diverse legacy systems–and offer practical strategies to accelerate the commercial adoption of grid-interactive efficient buildings.

Ham, Sang Woo↗

He Puff System For Dust Detector Upgrade

Local detection of surface dust is needed for the safe operation of next-step magnetic fusion devices such as ITER. An electrostatic dust detector, based on a 5 cm x 5 cm grid of interlocking circuit traces biased to 50 V, has been developed to detect dust on remote surfaces and was successfully tested for the first time on the National Spherical Torus Experiment (NSTX). We report on a helium puff system that clears residual dust from this detector and any incident debris or fibers that might cause a permanent short circuit. The entire surface of the detector was cleared of carbon particles by two consecutive helium puffs delivered by three nozzles of 0.45 mm inside diameter. The optimal configuration was found to be with the nozzles at an angle of 30o with respect to the surface of the detector and a helium backing pressure of 6 bar. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distribution System Planning for Growth in Residential Electric Vehicle Adoption

Anticipated growth in Electric Vehicles (EV) adoption could stress distribution system circuits beyond their original design limits. Uncertainties related to when households will begin buying EVs in large numbers challenges existing distribution system planning approaches and complicates efforts to assess grid impacts. Anticipated location, timing, and demand for EV charging is critical information for distribution system planners as it guides investment strategies for infrastructure upgrades to ensure continued reliability. This research makes two significant contributions: an EV adoption model that uses socioeconomic data to forecast location and year-specific adoption patterns through a bottoms-up approach, and an EV hosting capacity assessment methodology that offers improvements to current utility planning and asset management practices for infrastructure investments. Both contributions are applied to a Southern California Edison feeder in 7 adoption years from 2025 to 2050, with the results indicating that they are likely valuable additions to distribution systems planning capabilities.

Sridhar, Siddharth↗

H2@Scale Concept Hydrogen Demand and Resources

The H2@Scale concept involves hydrogen as an energy intermediate. Hydrogen can be produced from various conventional and renewable energy sources including as a responsive load on the electric grid. Hydrogen has many current applications and many more potential applications, such as energy for transportation, as a feedstock for synthetic fuels, and to upgrade oil and biomass, heat for industry and buildings, and electricity storage. Owing to its flexibility and fungibility, a hydrogen intermediate could link energy sources that have surplus availability to markets that require energy or chemical feedstocks, benefiting both. This data release provides estimates on hydrogens serviceable consumption potential for possible hydrogen applications and the technical potential for producing hydrogen from various resources. We define the technical potential as the resource potential constrained by real-world geography and system performance, but not by economics.

Array↗

Recent Advancements and Prospects of Chemical Heat Pumps for Temperature Amplification for Nuclear Process Heat Applications

The energy economy is continually evolving, particularly in terms of primary energy sources, their conversions to useful forms such as electricity and heat, and their utilization in different sectors, in response to socio-political factors. Because nuclear energy source is a clean and non-carbon-emitting energy source, it is crucial to consider its role in the evolution of the energy economy. Integrated Energy Systems (IES) are collaboratively controlled systems that can dynamically apportion thermal and/or electrical energy to promote the production of various energy products and have the potential to reduce greenhouse gas (GHG) emissions, improve energy efficiency, improve electrical grid dependability, and enhance energy economics. To realize the benefits of IES with the current reactor fleets, selection and development of a complimentary temperature upgrading technology are necessary for providing process heat and improving economics.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Maturity Model for Advancing Smart Grid Interoperability

Abstract—Interoperability is about the properties of devices and systems to connect and work properly. Advancing interoperability eases integration and maintenance of the resulting interconnection. This leads to faster integration, lower labor and component costs, predictability of projects and the resulting performance, and evolutionary paths for upgrade. When specifications are shared and standardized, competition and novel solutions can bring new value streams to the community of stakeholders involved. Advancing interoperability involves reaching agreement for how things join at their interfaces. The quality of the agreements and the alignment of parties involved in the agreement present challenges that are best met with process improvement techniques. The GridWise® Architecture Council (GWAC) sponsored by the United States Department of Energy is supporting an effort to use concepts from capability maturity models used in the software industry to advance interoperability of smart grid technology. An interoperability maturity model has been drafted and experience is being gained through trials on various types of projects and community efforts. This paper describes the value and objectives of maturity models, the nature of the interoperability maturity model and how it compares with other maturity models, and experiences gained with its use.

IEEE↗

High-Penetration Microgrids Providing Grid Stability Using Frequency Watt Control

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

14 SOLAR ENERGY↗

Master-Slave Control Scheme in Electric Vehicle Smart Charging Infrastructure

WINSmartEV is a software based plug-in electric vehicle (PEV) monitoring, control, and management system. It not only incorporates intelligence at every level so that charge scheduling can avoid grid bottlenecks, but it also multiplies the number of PEVs that can be plugged into a single circuit. This paper proposes, designs, and executes many upgrades to WINSmartEV. These upgrades include new hardware that makes the level 1 and level 2 chargers faster, more robust, and more scalable. It includes algorithms that provide a more optimal charge scheduling for the level 2 (EVSE) and an enhanced vehicle monitoring/identification module (VMM) system that can automatically identify PEVs and authorize charging.

42 ENGINEERING↗

Opportunities for Battery Storage Technologies in Mexico

This report provides a high-level summary of the current market trends for batteries and discusses the role battery storage technologies can play in Mexico's transition towards higher penetrations of variable renewable energy generation. This includes: frequency regulation, transmission upgrade deferral, distributed generation, and serving peak demand.

25 ENERGY STORAGE↗