Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid forming”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

On Stability of PQ-Controlled Grid-Following and Droop-Control Grid-Forming Inverters

In this paper, the nonlinearity impacts of PQ-control schemes and LCL filter parameter variations on the stability of grid-interactive inverters are studied under weak grid conditions. This work demonstrates that the control nonlinearity and parameter variations can cause unexpected instability at low power levels. This instability issue in the nominal operating range may occur under specific control parameters due to the shift of the low-frequency eigenvalues of PQ-controlled inverters. A full-order small-signal model for PQ-controlled inverters is applied to analyze this instability issue. Furthermore, the impacts of the droop coefficients on the stability of the droop-controlled grid-forming inverter are also investigated using the closed-loop inverter model. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator and a hardware setup of a microgrid fed by two 5 kVA 208V inverters.

Hossen, Tareq↗

A New Impedance-Based Modeling and Stability Analysis Approach for Power Oscillations Between Grid-Forming Inverters

This paper presents a new modeling and analysis approach to address the small-signal stability issues among interconnected grid-forming (GFM) inverters. A novel phasor domain “power impedance” model is developed to capture the terminal characteristics of GFM inverters. Based on the developed models, a sum-type impedance stability criterion is proposed to analyze the power oscillations between GFM Inverters. The developed models are validated with EMT simulations and the stability analysis results using the proposed stability criterion can match both EMT simulations and eigenvalue analysis. In addition, the application of the developed model can be extended to the stability analysis of large-scale power system with high penetration of GFM inverters.

Liu, Hanchao↗

Transient Stability Analysis of Direct Droop-Controlled Grid-Forming Inverter with Current Clipping as Current Limiting Control

This paper investigates the transient stability of the direct droop-controlled grid-forming (GFM) inverter which employs the current clipping-based approach for overcurrent limitation. An equivalent circuit model of the direct-droop GFM inverter with current clipping is developed for this purpose. It is shown that during overcurrent conditions, the GFM inverter with current clipping acts as a voltage source with a virtual resistance behind the inverter filters. To compute the parameters of this virtual resistance an analytical expression is given in the paper. Then utilizing the developed circuit, a criteria to exit current limiting during post-fault conditions is given. The developed analytical approaches are then validated through electromagnetic transient (EMT) simulation results in PSCAD software and finally concluding remarks are drawn.

Mohiuddin, Sheik Mohammad↗

Dynamic security assessment of systems powered only by grid-forming power plants with uncertain dispatch using polynomial vectors

A modern challenge in power engineering is to perform the dynamic security assessment (DSA) of grids that are 100% powered by inverter-based resources (IBRs). Addressing this challenge is difficult because: (i) the dispatch of IBRs can be uncertain as a result of the variability of renewable resources and (ii) they have hard current control limits that cannot be neglected, contrasting synchronous machines. To address this problem, this paper sets forth a framework to conduct DSA of bulk power systems that are 100% powered by grid-forming IBRs. Furthermore, the framework considers that IBR operational conditions are unknown but bounded by a zonotope which is also expressed as a polynomial vector for uncertainty propagation via Dormand–Prince integration. The framework is applied to modified versions of the WSCC 9-bus and IEEE 39-bus grids.

14 SOLAR ENERGY↗

A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters

This paper presents a two-stage current limiting control strategy with fault ride-through capability for the direct-droop-controlled grid-forming (GFM) inverters. The proposed approach comprises Stage 1 and Stage 2 current limiting controls. During faults, Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control, and Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through electromagnetic transient (EMT) simulation results conducted on a single GFM inverter-based test system and the IEEE 39-bus test system with multiple GFM inverters in the PSCAD platform.

Mohiuddin, Sheik Mohammad↗

How a Large-Scale Deployment of Grid-Forming Inverters May Impact Inter-Area Oscillation Modes: An Investigation in the US Western Interconnection

This report describes work performed to evaluate the impact of high grid-forming (GFM) inverter penetration on the inter-area oscillation mode characteristics of the Western Interconnection. Using simulations, this work analyzes how: a) replacing fossil-fuel-based synchronous generators by GFM inverters will impact properties of the North-South mode, and b) replacing the Colstrip power plant by grid-following (GFL) and GFM inverters will change the characteristics of the Montana mode. Results obtained indicate that high penetration of GFM inverters will significantly alter inter-area oscillation characteristics in interconnections. Low frequency oscillations in the 0.11 Hz range will be predominantly driven by remaining synchronous machines, and hence their relative distribution in the interconnection will impact mode characteristics and observability.

20 FOSSIL-FUELED POWER PLANTS↗

Open-Source PSCAD Grid-Following and Grid-Forming Inverters and a Benchmark for Zero-Inertia Power System Simulations: Preprint

This paper presents open-source, flexible, and easily-scalable models of grid following and grid forming inverters for the PSCAD software platform. The models are intended for system integration studies, particularly stability analyses of power systems with high penetration of inverter-based generation. To verify the model functionality, they are implemented in a IEEE9-bus system in a zero-inertia operational scenario of 100% inverter-based generation. The models have been made available open source at the PyPSCAD NREL GitHub page.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation

Here, this letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct (d)-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Microgrids With Self-Organized Grid-Forming Inverters in Unbalanced Distribution Feeders

In contrast to conventional static microgrids (MGs), MGs with dynamic and adjustable territories (i.e., dynamic MGs) are proposed and implemented in this paper. Dynamic MGs are commonly dominated by grid-forming inverters and nested in unbalanced distribution feeders. Unlike balanced systems where only positive-sequence components exist, proper operation of unbalanced dynamic MGs presents additional challenges. A distributed secondary control strategy is developed in this study for distributed generators (DGs) interfaced with gridforming inverters in unbalanced dynamic MGs by providing coordinated regulations on both positive- and negative-sequence system models. System frequency and voltage are under constant regulation, along with voltage unbalance (VU) management for multiple critical load buses (CLB). The proposed control strategy enables seamless system transition during unbalanced dynamic MGs reconfiguration, and guarantees proportional positive- and negative-sequence power sharing among connected DGs with respect to system topology variation. Detailed controller designs are provided and stability analyses are derived. The proposed control strategy is fully implemented in hardware controllers and validated on a Hardware-in-the-Loop (HIL) MG testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid to Microgrid Synchronization with Grid-Forming Inverters: Challenges and Solution

Research on network microgrids has primarily focused on control and optimization. However, application aspects such as microgrid-to-microgrid synchronization have not been fully addressed in existing literature. This paper first addresses the challenges of networking microgrids with grid-forming inverter in droop control. Then, it proposes a pre-synchronization algorithm to improves the synchronization speed and transient stability. To improve the speed, the phase difference between adjacent microgrids is minimized. Transients such as inrush current and oscillations are effectively mitigated by increasing the virtual impedance during interconnection. The proposed strategy allows smooth transitions when reconfiguration of the microgrids is needed. The applicability of this strategy to today’s microgrid systems is demonstrated through a validation in a 480V three-phase network microgrid testbed with commercial-grade inverters, protective devices, and switchgear.

Ferrari Maglia, Max↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

Optimal Droop Setting for Congestion Reduction in a 100% Grid-Forming Inverter-based Power System

he high penetration of inverter-based resources (IBRs) introduces new challenges to power systems due to the complex inverter control. However, IBRs can be configured to maximize their benefits to improve system resilience and reliability. This paper proposes a steady-state optimization model that aims to mitigate transmission congestion in a 100% grid- forming (GFM) IBR-based power system. This goal is achieved by determining the optimal droop settings for the GFM IBRs under different congestion conditions due to renewable energy and load variations. The numerical solution is rigorously verified by a high-fidelity model of the IEEE 39-bus test system with detailed GFM IBR control in the time-domain electromagnetic transient (EMT) simulation tool PSCAD. The numerical solution and simulation results show a significant congestion reduction while meeting all other operating requirements. It is also observed that the numerical solving time is substantially less compared to the EMT simulation time.

Nguyen, Quan H.↗

Protection of 100% Inverter-dominated Power Systems with Grid-Forming Inverters and Protection Relays – Gap Analysis and Expert Interviews

This report summarizes a gap analysis resulting from a literature review and expert interviews conducted by subject matter experts from Sandia National Laboratory, Siemens, and the Electric Power Research Institute (EPRI) in Spring 2023. The gap analysis consists of two main parts: The fault-ride through (FRT) behavior of grid-forming (GFM) inverter-based resources (IBR) and the response of state-of-the-art protection relays to the fault currents and voltages from GFM IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Model Calibration Method for Grid-Forming Inverters Using Iterative Bayesian Optimization

As inverter-based resources (IBRs) are rapidly deployed, especially at the distribution and microgrid levels, the need to include their accurate representations in power systems models increases. With well-calibrated models, IBR-interactions can be examined, preventing any stability and operational issues, especially in islanded systems. This paper proposes a method to calibrate generic inverter models using Bayesian optimization, but with a parameter-grouping approach to improve speed and accuracy. This approach is illustrated for a grid-forming inverter using synthetic data and field measurements from a simple IBRbased microgrid. Tests show that the calibration algorithm has modest computation cost and is robust to noisy measurements..

Biswas, Shuchismita↗

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.

Kim, Jinho [BATTELLE (PACIFIC NW LAB)]↗

Global Phase and Magnitude Synchronization of Coupled Oscillators With Application to the Control of Grid-Forming Power Inverters

In this paper, we explore a new approach to synchronization of coupled oscillators. In contrast to the celebrated Kuramoto model, we do not work in polar coordinates and do not consider oscillations of fixed magnitude. We propose a synchronizing feedback based on relative state information and local measurements that induces consensus-like dynamics. We show that, under a mild stability condition, the combination of the synchronizing feedback with a decentralized magnitude control law renders the oscillators' almost globally asymptotically stable with respect to set points for the phase shift, frequency, and magnitude. We apply these result to rigorously solve an open problem in control of inverter-based ac power systems. In this context, the proposed control strategy can be implemented using purely local information, induces a grid-forming behavior, and ensures that a network of ac power inverters is almost globally asymptotically stable with respect to a prespecified solution of the ac power-flow equations. Moreover, we show that the controller exhibits a droop-like behavior around the standard operating point, thus, making it backward compatible with the existing power system operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stabilizing the Power System in 2035 and Beyond: Evolving from Grid-Following to Grid-Forming Distributed Inverter Controllers (Final Technical Report)

Under existing grid operations, large synchronous generators provide sufficient rotational inertia to form a rigid backbone for the bulk power system. With photovoltaics (PV) forecasted to provide more than 600 GW of generation by 2050 under the U.S. Department of Energy’s SunShot Initiative objectives, however, it is clear that power electronic inverters will play a dominant role in future systems, and low-inertia stability must be ensured to maintain system reliability. Today, the risks to system stability can be observed on geographically small islands, such as Hawaii, which contain a relatively large amount of installed PV. These risks stem from a fundamental shortcoming of contemporary control strategies—existing inverter controllers cannot guarantee grid stability. Given that future power systems driven by sustainable resources will be characterized by low inertia, locations such as Hawaii provide a glimpse into the obstacles facing future power systems. Considering these challenges, the aim of this project was to develop and demonstrate distributed inverter controllers that enable the reliable control of low-inertia power systems with hundreds of gigawatts of integrated PV.

14 SOLAR ENERGY↗