Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid application”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A High-Performance Na-Al Battery Based on Reversible NaAlCl4 Catholyte

This work demonstrates a high-capacity and safe Na-Al battery pairing sodium metal anode and reversible NaAlCl4 catholyte for grid scale energy storage applications. The energy-rich sodium anode allows the full play of the aluminum cathode, resulting in a full-cell capacity of 308 mAh/g at a discharge voltage of 1.6 V. Benefiting from the use of ??-alumina solid electrolyte (BASE), molten sodium anode and reversible Al deposition/stripping from NaAlCl4 catholyte, the battery presents a stable Coulombic efficiency of 100% and energy efficiency of ~95%. At a rate of C/3 (6.77 mA/cm2), the cell maintains 282 mAh/g (447 Wh/kg) after 200 cycles with an excellent capacity retention of 97.6%. Moreover, we elucidate pathways to build sodium-anode-free cells from the discharged state under dry air, which further extends the feasibility of this battery for stationary storage applications. These findings are expected to provide a new platform for the development of practical Al batteries.

Zhan, Xiaowen↗

Lewis Acid Site Assisted Bifunctional Activity of Tin Doped Gallium Oxide and Its Application in Rechargeable Zn‐Air Batteries

The enhanced safety, superior energy, and power density of rechargeable metal‐air batteries make them ideal energy storage systems for application in energy grids and electric vehicles. However, the absence of a cost‐effective and stable bifunctional catalyst that can replace expensive platinum (Pt)‐based catalyst to promote oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) at the air cathode hinders their broader adaptation. Here, in this work, it is demonstrated that Tin (Sn) doped β‐gallium oxide (β‐Ga 2 O 3 ) in the bulk form can efficiently catalyze ORR and OER and, hence, be applied as the cathode in Zn‐air batteries. The Sn‐doped β‐Ga 2 O 3 sample with 15% Sn (Sn x =0.15 ‐Ga 2 O 3 ) displayed exceptional catalytic activity for a bulk, non‐noble metal‐based catalyst. When used as a cathode, the excellent electrocatalytic bifunctional activity of Sn x =0.15 ‐Ga 2 O 3 leads to a prototype Zn‐air battery with a high‐power density of 138 mW cm −2 and improved cycling stability compared to devices with benchmark Pt‐based cathode. The combined experimental and theoretical exploration revealed that the Lewis acid sites in β‐Ga 2 O 3 aid in regulating the electron density distribution on the Sn‐doped sites, optimize the adsorption energies of reaction intermediates, and facilitate the formation of critical reaction intermediate (O*), leading to enhanced electrocatalytic activity.

Lewis acid sites↗

Revolutionizing Energy Storage: AI, Automation, and Advanced Modeling as Catalysts for Next-Generation Breakthroughs

The Presidential Symposium (PRES) at the 2025 Fall Meeting, hosted by the President’s Office and Energy and Fuels Division, American Chemical Society (ACS) in Washington, DC, brought together a diverse group of chemists, engineers, and materials scientists working in battery materials & systems, automation and artificial intelligence from academia, industry, and national laboratories. The accelerating demand for high-performance, scalable, and sustainable energy storage has catalyzed a paradigm shift in how materials are dis-covered, devices are engineered, and systems are optimized. This Presidential Symposium, entitled “Revolutionizing Energy Storage: AI, Automation, and Advanced Modeling Driving Next-Gen Breakthroughs”, brings together global leaders to unveil transformative strategies anchored in the AAA framework: Artificial Intelligence, Automation, and Advanced Modeling. Artificial Intelligence is redefining the frontiers of energy storage by enabling predictive design, real-time optimization, and intelligent control across diverse chemistries and architectures. Automation is streamlining the synthesis, characterization, and testing of battery materials, dramatically accelerating innovation cycles and unlocking scalable solutions for grid and mobility applications. Advanced Modeling, spanning atomic to system-level scales, provides unprecedented insight into electrochemical dynamics, degradation pathways, and thermal behavior, particularly when coupled with physics-informed machine learning and digital twin technologies. Digital twins, in turn, leverage the AAA framework by integrating real-time data, physics-based models, and AI predictions into dynamic virtual replicas, enabling proactive diagnostics, optimization, and system resilience. Together, these synergistic pillars are not only re-shaping the scientific landscape but also forging a new era of reproducible, data-driven, and resilient energy storage innovation. In conclusion, this symposium marks a pivotal moment in the convergence of computational intelligence and experimental rigor, charting the course for next-generation breakthroughs in lithium-ion, solid-state, and flow battery technologies.

Artificial Intelligence (AI)↗

Fluoride-Rich, Organic–Inorganic Gradient Interphase Enabled by Sacrificial Solvation Shells for Reversible Zinc Metal Batteries

Zinc metal batteries are strongly hindered by water corrosion, as solvated zinc ions would bring the active water molecules to the electrode/electrolyte interface constantly. Herein, we report a sacrificial solvation shell to repel active water molecules from the electrode/electrolyte interface and assist in forming a fluoride-rich, organic-inorganic gradient solid electrolyte interface (SEI) layer. Additionally, the simultaneous sacrificial process of methanol and Zn(CF 3 SO 3 ) 2 results in the gradient SEI layer with an organic-rich surface (CH 2 OC- and C 5 product) and an inorganic-rich (ZnF 2 ) bottom, which combines the merits of fast ion diffusion and high flexibility. As a result, the methanol additive enables corrosion-free zinc stripping/plating on copper foils for 300 cycles with an average coulombic efficiency of 99.5%, a record high cumulative plating capacity of 10 A h/cm 2 at 40 mA/cm 2 in Zn/Zn symmetrical batteries. More importantly, at an ultralow N/P ratio of 2, the practical VO 2 //20 mu m thick Zn plate full batteries with a high areal capacity of 4.7 mAh/cm 2 stably operate for over 250 cycles, establishing their promising application for grid-scale energy storage devices. Furthermore, directly utilizing the 20 μm thick Zn for the commercial-level areal capacity (4.7 mAh/cm 2 ) full zinc battery in our work would simplify the manufacturing process and boost the development of the commercial zinc battery for stationary storage.

25 ENERGY STORAGE↗

Electrode Blocking Due to Redox Reactions in Aluminum Chloride-Sodium Iodide Molten Salts

Iodide redox reactions in molten NaI/AlCl 3 are shown to generate surface-blocking films, which may limit the useful cycling rates and energy densities of molten sodium batteries below 150 °C. An experimental investigation of electrode interfacial stability at 110 °C reveals the source of the reaction rate limitations. Electrochemical experiments in a 3-electrode configuration confirm an increase of resistance on the electrode surface after oxidation or reduction current is passed. Using chronopotentiometry, chronoamperometry, cyclic voltammetry, and electrochemical impedance spectroscopy, the film formation is shown to depend on the electrode material (W, Mo, Ta, or glassy carbon), as well as the Lewis acidity and molar ratio of I − /I 3 − in the molten salt electrolytes. These factors impact the amount of charge that can be passed at a given current density prior to developing excessive overpotential due to film formation that blocks the electrode surface. The results presented here guide the design and use of iodide-based molten salt electrolytes and electrode materials for grid scale battery applications.

25 ENERGY STORAGE↗

Challenges and needs for system-level electrochemical lithium-ion battery management and diagnostics

The desire for energy-dense and fast-charged battery technology in consumer-electronics, electric-vehicle, grid, and aviation applications is pushing the envelope on materials to cells and pack designs to use and operating conditions. However, some approaches could inherently decrease safety of the battery—thus requiring the development of advanced management and diagnostics. Safety of lithium-ion batteries (LiBs), particularly in multicell configurations, is highly variable and could evolve with use. Existing works primarily focus on cell life and safety diagnostics without considering module and pack-level uncertainties and sometimes imply that cell-level electrochemical diagnostics would work in modules or packs, a naive oversimplification. Using example case studies, we highlight the potential and challenges associated with extending single-cell diagnostics to multiple cells, note the challenge involved, and motivate the research and development and support communities to devote efforts to fill the gap by developing diagnostics at these levels for current- and future-generation LiBs.

25 ENERGY STORAGE↗

Operando bulk and interfacial characterization for electrochemical energy storage: Case study employing isothermal microcalorimetry and X-ray absorption spectroscopy

Abstract The global shift to electricity as the main energy carrier will require innovation in electrochemical energy storage (EES). EES systems are the key to the “electron energy economy,” minimizing losses and increasing reliability between energy supply and demand. However, steep challenges such as cost, cycle/calendar life, energy density, material availability, and safety limit widespread adoption of batteries for large-scale grid and vehicle applications. Battery innovation that meets today’s challenges will require new chemistries, which can originate from understanding charge transport phenomena at multiple time and length scales. The advancement of operando characterization can expedite this progress as changes can be observed during battery function. This article highlights progress in bulk and interfacial operando characterization of batteries. Specifically, a case study involving Fe 3 O 4 is provided demonstrating that combining X-ray absorption spectroscopy and isothermal microcalorimetry can provide real-time characterization of productive faradaic redox processes and parasitic interfacial reactions during (de)lithiation. Graphic abstract

36 MATERIALS SCIENCE↗

Power-to-Gas System Valuation. Final Report

To provide a framework for evaluating the technical and financial benefits of a power-to-gas (P2G) system deployed in the Holyoke Gas and Electric (HG&E) system, Pacific Northwest National Laboratory modified its energy storage valuation tools to run a one-year simulation of P2G operations. The simulation was used to evaluate the benefits of P2G for multiple grid and industrial applications over the economic life of the unit, or units, depending on the asset configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structure-preserving numerical discretizations for domains with boundaries

This SAND report documents Exploratory Express LDRD Project 223790, "Structure-preserving numerical discretizations for domains with boundaries", which developed a method to incorporate consistent treatment of domain boundaries and arbitrary boundary conditions in discrete exterior calculus (DEC) for arbitrary polygonal (2D) and tensor-product structure prism (3D) grids. The new DEC required the development of novel discrete exterior derivatives, boundary operators, wedge products and Hodge stars. This was accomplished through the use of boundary extension and the blending of known 2D operators on the interior with 1D operators on the boundary. The Hodge star was based on the Voronoi Hodge star, and retained the limitation of a triangular circumcentric primal or dual grid along with low-order accuracy. In addition to the new DEC, two related software packages were written: one for the study of DEC operators on arbitrary polygonal and polyhedral grids using both symbolic and numerical approaches and one for a (thermal) shallow water testbed using TRiSK-type numerics. Immediately relevant (already funded, through CANGA) followup work is the development of a high-order, geometrically flexible Hodge star and structure-preserving, high-order, oscillation-limiting transport operators (using WENO) for n-forms on arbitrary 2D and 3D grids. This will provide all of the machinery required for a high-order version of TRiSK with boundaries on arbitrary 2D and tensor-product 3D grids, which is applicable to both the atmospheric (CRM in E3SM-MMF) and oceanic (MPAS-O) components of E3SM.

97 MATHEMATICS AND COMPUTING↗

Computational and Experimental Validation of Fractal-Fin, Dimpled Solar Heat Collector

A 3 foot x 3 foot x 3 foot aluminum solar collector was manufactured using computer numerical control. The interior of the device included six triangular dimpled fins for enhanced heat transfer. The interior vertical wall on the south side was also dimpled. The solar collector working fluid was based on water, and the collector consisted solely of passive heat transfer mechanisms (no moving parts), making it ideal for off-the-grid and rural applications. Two types of heat transfer experiments were conducted. One experiment had external flat heaters attached on the top and the front side, while the other four sides were insulated. Except for the bottom surface, the second experiment had all its exterior surfaces sprayed with black solar paint to collect as much solar heat as possible. Temperature data as a function of time was collected using 14 thermocouples spread strategically throughout the solar collector. In addition, computational fluid dynamics (CFD) simulations were conducted using the dynamic Smagorinsky large eddy simulation turbulence model. The first simulation considered that both the top and front surfaces were exposed to a fixed temperature of 313.7 K (105 °F), while the remaining four surfaces were insulated. For the second simulation, all conditions were the same, except that the temperature for both heated surfaces was raised to 350 K (170.3 °F). The two temperatures are expected to bound the solar collector operational temperature during the late- Spring, Summer, and early-Fall months. The solar collector design, experimental data, CFD output, and a discussion of five manufacturing approaches and costs are documented in this report.

14 SOLAR ENERGY↗

Use Case-Informed Framework for Utility Cloud Migration

This white paper presents a comprehensive methodology for assessing utilities’ cloud postures and frameworks. It aims to produce a roadmap and strategy for a cloud-enabled grid future, providing guidance for integrators, asset owners, and operators. Instead of offering a yes or no answer for cloud implementation, this framework offers strategic guidance on responsibly preparing for and deploying cloud solutions. This paper delves into cloud-service models pertinent to the electric sector, dissecting the shared responsibility model and elucidating what on-premise infrastructure as a service (IaaS), platform as a service (PaaS), and software as a service (SaaS) entail. A pivotal consideration within the context of the shared responsibility model is the allocation of responsibility for foundational security aspects—a decision that will be informed by a comprehensive risk assessment. The ensuing discussion will present a checklist of certifications necessary for a secure cloud transition, equipping utilities with the knowledge to navigate this digital transformation with confidence and with a strategic roadmap. Furthermore, the paper outlines gaps in understanding the U.S. government’s role in shaping technology development and responsible use. Its purpose is to aid decision-making by offering support for risk-informed solutions that benefit those managing assets and operating in the cloud environment. The primary objective is to enhance the resilience and future readiness of a decarbonized electric grid, with cloud solutions as one viable option. The paper synthesizes information on current and future grid architectures and applications, considering both conservative and progressive energy transitions, along with scalable and distributed computing considerations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extending the operating range and safety of Li-ion batteries with new fluorinated electrolytes

Orbia Fluor and Energy Materials (formerly Koura) has successfully developed a new class of fluorinated electrolyte solvents for lithium-ion batteries. In collaboration with Silatronix and Argonne National Laboratory, the team synthesized and screened over 20 novel fluorinated compounds, optimizing formulations that significantly enhance battery performance across critical metrics such as thermal stability, fast-charging capability, and cycling life at extreme temperatures. Electrolytes with fluorinated molecules developed in this program demonstrated superior performance in 2 Ah pouch cells, achieving over 1000 fast-charge cycles with minimal capacity fade, outperforming conventional carbonate-based electrolytes. Mechanistic studies revealed that the fluorinated electrolytes promote a stable solid electrolyte interphase at the anode and reduce cathode metal dissolution, contributing to improved long-term stability. These advancements mark a significant step toward safer, more efficient batteries for applications ranging from grid storage to defense systems to electric vehicles. We gratefully acknowledge DOE’s financial support through contract DE-EE0009642.

25 ENERGY STORAGE↗

Self-powered Heating: Efficiency Analysis

Conventional fuel-fired heating devices such as furnaces, boilers, and water heaters have fuel efficiency less than 100% on the basis of higher heating value. They also require electricity from the electric grid to power parasitic loads such as blowers, pumps, fans, and ignitors. The primary energy efficiency of the device accounts for both fuel used on-site and primary energy used off-site to produce electric power used by the device. This work compares conventional fuel-fired heating devices to two types of self-powered devices. A self-powered device (SPD) integrates a power cycle onboard to eliminate consumption of grid electricity. We assume that all heat rejected by the onboard power cycle is added to the process fluid, so that, compared with a conventional device, the same amount of heat is provided to the process fluid and the same amount of fuel is consumed, but grid electricity consumption is eliminated. The first SPD type is the basic one: exactly the electricity required is generated. The second type considered is the SPD with heat pump (SPD-HP), in which the power cycle generates more electricity than needed for parasitic loads, and the excess electricity is used to power a heat pump. The heat pump extracts additional heat from the ambient to boost efficiency. Both SPD and SPD-HP self-consume all the generated electricity, in contrast to combined heat and power (CHP) systems that export electricity. In this work, equations are derived to express the efficiency of three classes of heating devices: conventional (consuming grid electricity), self-powered (consuming no grid electricity), and self-powered with heat pump. The efficiency of each is derived as a function of up to six factors: (1) the fraction of combustion heat captured, (2) the rate of parasitic power consumption, (3) the fraction of electric energy dissipated as useful heat, (4) the power cycle conversion efficiency, (5) the grid efficiency, when applicable, and (6) the heat pump COP, when applicable. Scenarios are identified in which it is possible to achieve efficiency greater than 100% on a higher heating value basis. Plausible configurations using existing technology options are outlined.

Gluesenkamp, Kyle↗

Efficient Network Partitioning: Application for Decentralized State Estimation in Power Distribution Grids: Preprint

Increase in the proliferation of DERs requires real-time situational awareness for efficient grid operations. State estimation plays an important role for real time control and management of the power grid. As the sensing infrastructure grows, aggregating and handling high volumes of data at a centralized location is extremely difficult. To address this challenge, this paper first proposes a novel and efficient hierarchical spectral clustering-based network partition algorithm followed by a decentralized compressive sensing (DCS) based state estimation. The applicability of the proposed network partitioning algorithm is tested on IEEE-123 bus, IEEE-8500 node, and a 6204-node distribution network. The results shows that the proposed approach efficiently divides the network into multiple sub-networks with the minimum edge connections among the neighbors. Then, we perform DCS-based state estimation on the 6204-node distribution network after dividing the network into 18 optimal partitions. Simulation results show that DCS-based state estimation recovers the system states with high accuracy and low complexity.

ADMM↗

Efficient Network Partitioning: Application for Decentralized State Estimation in Power Distribution Grids

Increase in the proliferation of distributed energy resources require real-time situational awareness for efficient grid operations. State estimation plays an important role for the real-time control and management of the power grid. As the sensing infrastructure grows, aggregating and handling high volumes of data at a centralized location is extremely difficult. To address this challenge, this paper first proposes a novel and efficient hier-archical spectral clustering-based network partitioning algorithm followed by a decentralized compressive sensing (DCS)-based state estimation. The applicability of the proposed network partitioning algorithm is tested on an IEEE 123-bus network, an IEEE 8,500-node system, and a 6,000+ node distribution network. The results shows that the proposed approach efficiently divides the network into multiple sub-networks with the minimum number of edge connections among the neighbors. Then, we perform DCS-based state estimation on the 6,000+ node distribution network after dividing the network into 18 optimal partitions. Simulation results show that the DCS-based state estimation recovers the system states with high accuracy and low complexity.

alternating direction method of multipliers↗

EVs@Scale FUSE Fall '24 Deep Dive

Electric vehicle (EV) adoption will expand beyond light-duty vehicles charging at lower-power public locations and family residences to include medium- and heavy-duty applications with more powerful charging at public stations and private depots. The Vehicle Grid Integration (VGI) and Smart Charge Management (SCM) pillar in EVs@Scale supports multiple projects. The FUSE project is developing and evaluating enabling technologies, charging solutions, and infrastructure design approaches to investigate the intricacies and potential benefits of vehicle grid integration and the application of smart charge management to charging of electric vehicles at scale. This presentation delves into the technical findings of this research in 2024.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Time Synchronization Techniques in the Modern Smart Grid: A Comprehensive Survey

In modern smart grids, accurate and synchronized time signals are essential for effective monitoring, protection, and control. Various time synchronization methods exist, each tailored to specific application needs. Widely adopted solutions, such as GPS, however, are vulnerable to challenges such as signal loss and cyber-attacks, underscoring the need for reliable backup or supplementary solutions. This paper examines the timing requirements across different power grid applications and provides a comprehensive review of available time synchronization mechanisms. Through a comparative analysis of timing methods based on accuracy, flexibility, reliability, and security, this study offers insights to guide the selection of optimal solutions for seamless grid integration.

comparison↗