Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Practical implications of SFQ-based two-qubit gates

Scalability of today’s superconducting quantum computers is limited due to the huge costs of generating/routing microwave control pulses per qubit from room temperature. One active research area in both industry and academia is to push the classical controllers to the dilution refrigerator in order to increase the scalability of quantum computers. Superconducting Single Flux Quantum (SFQ) is a classical logic technology with low power consumption and ultra-high speed, and thus is a promising candidate for in-fridge classical controllers with maximized scalability. Prior work has demonstrated high-fidelity SFQ-based single-qubit gates. However, little research has been done on SFQ-based multi-qubit gates, which are necessary to realize SFQ-based universal quantum computing.In this paper, we present the first thorough analysis of SFQ-based two-qubit gates. Our observations show that SFQ-based two-qubit gates tend to have high leakage to qubit non-computational subspace, which presents severe design challenges. We show that despite these challenges, we can realize gates with high fidelity by carefully designing optimal control methods and qubit architectures. We develop optimal control methods that suppress leakage, and also investigate various qubit architectures that reduce the leakage. After carefully engineering our SFQ-friendly quantum system, we show that it can achieve similar gate fidelity and gate time to microwave-based quantum systems. Furthermore, the promising results of this paper show that (1) SFQ-based universal quantum computation is both feasible and effective; and (2) SFQ is a promising approach in designing classical controller for quantum machines because it can increase the scalability while preserving gate fidelity and performance.

42 ENGINEERING↗

A practical approach to determine minimal quantum gate durations using amplitude-bounded quantum controls

Here, we present an iterative scheme to estimate the minimal duration in which a quantum gate can be realized while satisfying hardware constraints on the control pulse amplitudes. The scheme performs a sequence of unconstrained numerical optimal control cycles that each minimize the gate fidelity for a given gate duration alongside an additional penalty term for the control pulse amplitudes. After each cycle, the gate duration is adjusted based on the inverse of the resulting maximum control pulse amplitudes by re-scaling the dynamics to a new duration where control pulses satisfy the amplitude constraints. Those scaled controls then serve as an initial guess for the next unconstrained optimal control cycle, using the adjusted gate duration. We provide multiple numerical examples that each demonstrate fast convergence of the scheme toward a gate duration that is close to the quantum speed limit, given the control pulse amplitude bound. The proposed technique is agnostic to the underlying system and control Hamiltonian models, as well as the target unitary gate operation, making the time-scaling iteration an easy to implement and practically useful scheme for reducing the durations of quantum gate operations.

97 MATHEMATICS AND COMPUTING↗

Automatic Qubit Characterization and Gate Optimization with QubiC

As the size and complexity of a quantum computer increases, quantum bit (qubit) characterization and gate optimization become complex and time-consuming tasks. Current calibration techniques require complicated and verbose measurements to tune up qubits and gates, which cannot easily expand to the large-scale quantum systems. We develop a concise and automatic calibration protocol to characterize qubits and optimize gates using QubiC, which is an open source FPGA (field-programmable gate array) based control and measurement system for superconducting quantum information processors. We propose multi-dimensional loss-based optimization of single-qubit gates and full XY-plane measurement method for the two-qubit CNOT gate calibration. We demonstrate the QubiC automatic calibration protocols are capable of delivering high-fidelity gates on the state-of-the-art transmon-type processor operating at the Advanced Quantum Testbed at Lawrence Berkeley National Laboratory. Finally, the single-qubit and two-qubit Clifford gate infidelities measured by randomized benchmarking are of 4.9(1.1) × 10 -4 and 1.4(3) × 10 -2 , respectively.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Linear Accelerator Gating With Real-Time Electromagnetic Tracking

Purpose: Intrafraction organ motion can produce dosimetric errors in radiotherapy. Commonly, the linear accelerator is gated using real-time breathing phase obtained by way of external sensors. However, the external anatomy does not always correlate well with the internal position. We examined a beam gating technique using signals from implanted wireless transponders that provided real-time feedback on the tumor location without an imaging dose to the patient. Methods and Materials: An interface was developed between Calypso Medical's four-dimensional electromagnetic tracking system and a Varian Trilogy linear accelerator. A film phantom was mounted on a motion platform programmed with lung motion trajectories. Deliveries were performed when the beam was gated according to the signal from the wireless transponders. The dosimetric advantages of beam gating and the system latencies were quantified. Results: Beam gating using on internal position monitoring provided up to a twofold increase in the dose gradients. The percentage of points failing to be within {+-}10 cGy of the planned dose (maximal dose, {approx}200 cGy) was 3.4% for gating and 32.1% for no intervention in the presence of motion. The mean latencies between the transponder position and linear accelerator modulation were 75.0 {+-}12.7 ms for beam on and 65.1 {+-} 12.9 ms for beam off. Conclusion: We have presented the results from a novel method for gating the linear accelerator using trackable wireless internal fiducial markers without the use of ionizing radiation for imaging. The latencies observed were suitable for gating using electromagnetic fiducial markers, which results in dosimetric improvements for irradiation in the presence of motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon-Ion Pencil Beam Scanning Treatment With Gated Markerless Tumor Tracking: An Analysis of Positional Accuracy

Purpose: Having implemented amplitude-based respiratory gating for scanned carbon-ion beam therapy, we sought to evaluate its effect on positional accuracy and throughput. Methods and Materials: A total of 10 patients with tumors of the lung and liver participated in the first clinical trials at our center. Treatment planning was conducted with 4-dimensional computed tomography (4DCT) under free-breathing conditions. The planning target volume (PTV) was calculated by adding a 2- to 3-mm setup margin outside the clinical target volume (CTV) within the gating window. The treatment beam was on when the CTV was within the PTV. Tumor position was detected in real time with a markerless tumor tracking system using paired x-ray fluoroscopic imaging units. Results: The patient setup error (mean ± SD) was 1.1 ± 1.2 mm/0.6 ± 0.4°. The mean internal gating accuracy (95% confidence interval [CI]) was 0.5 mm. If external gating had been applied to this treatment, the mean gating accuracy (95% CI) would have been 4.1 mm. The fluoroscopic radiation doses (mean ± SD) were 23.7 ± 21.8 mGy per beam and less than 487.5 mGy total throughout the treatment course. The setup, preparation, and irradiation times (mean ± SD) were 8.9 ± 8.2 min, 9.5 ± 4.6 min, and 4.0 ± 2.4 min, respectively. The treatment room occupation time was 36.7 ± 67.5 min. Conclusions: Internal gating had a much higher accuracy than external gating. By the addition of a setup margin of 2 to 3 mm, internal gating positional error was less than 2.2 mm at 95% CI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decoherence-protected quantum gates for a hybrid solid-state spin register

Protecting the dynamics of coupled quantum systems from decoherence by the environment is a key challenge for solid-state quantum information processing. An idle quantum bit (qubit) can be efficiently insulated from the outside world by dynamical decoupling, as has recently been demonstrated for individual solid-state qubits. However, protecting qubit coherence during a multi-qubit gate is a non-trivial problem in general, the decoupling disrupts the interqubit dynamics and hence conflicts with gate operation. This problem is particularly salient for hybrid systems, in which different types of qubit evolve and decohere at very different rates. Here we present the integration of dynamical decoupling into quantum gates for a standard hybrid system, the electron-nuclear spin register. Our design harnesses the internal resonance in the coupled-spin system to resolve the conflict between gate operation and decoupling. We experimentally demonstrate these gates using a two-qubit register in diamond operating at room temperature. Quantum tomography reveals that the qubits involved in the gate operation are protected as accurately as idle qubits. We also perform Grover's quantum search algorithm, and achieve fidelities of more than 90% even though the algorithm run-time exceeds the electron spin dephasing time by two orders of magnitude. Our results directly allow decoherence-protected interface gates between different types of solid-state qubit. Ultimately, quantum gates with integrated decoupling may reach the accuracy threshold for fault-tolerant quantum information processing with solid-state devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent molecular transistor: Control through variation of the gate wave function

In quantum interference transistors (QUITs), the current through the device is controlled by variation of the gate component of the wave function that interferes with the wave function component joining the source and the sink. Initially, mesoscopic QUITs have been studied and more recently, QUITs at the molecular scale have been proposed and implemented. Typically, in these devices the gate lead is subjected to externally adjustable physical parameters that permit interference control through modifications of the gate wave function. Here, we present an alternative model of a molecular QUIT in which the gate wave function is directly considered as a variable and the transistor operation is discussed in terms of this variable. This implies that we specify the gate current as well as the phase of the gate wave function component and calculate the resulting current through the source-sink channel. Thus, we extend on prior works that focus on the phase of the gate wave function component as a control parameter while having zero or certain discrete values of the current. We address a large class of systems, including finite graphene flakes, and obtain analytic solutions for how the gate wave function controls the transistor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Side-gate modulation effects on high-quality BN-Graphene-BN nanoribbon capacitors

High-quality BN-Graphene-BN nanoribbon capacitors with double side-gates of graphene have been experimentally realized. The double side-gates can effectively modulate the electronic properties of graphene nanoribbon capacitors. By applying anti-symmetric side-gate voltages, we observed significant upward shifting and flattening of the V-shaped capacitance curve near the charge neutrality point. Symmetric side-gate voltages, however, only resulted in tilted upward shifting along the opposite direction of applied gate voltages. These modulation effects followed the behavior of graphene nanoribbons predicted theoretically for metallic side-gate modulation. The negative quantum capacitance phenomenon predicted by numerical simulations for graphene nanoribbons modulated by graphene side-gates was not observed, possibly due to the weakened interactions between the graphene nanoribbon and side-gate electrodes caused by the Ga{sup +} beam etching process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Double-gate SnO{sub 2} nanowire electric-double-layer transistors with tunable threshold voltage

Double-gate Sb-SnO{sub 2} nanowire electric-double-layer (EDL) transistors with in-plane gates were fabricated using only one shadow mask. The threshold voltage of such devices can be tuned in a wide range from −0.13 V to 0.72 V by the in-plane gate, which allows the device to switch from depletion-mode to enhancement-mode operation. The operation voltage of the double-gate device is 1 V because the EDL gate dielectric can lead to a high gate capacitance (>3.5 μF/cm{sup 2}). Moreover, all double-gate devices show good electrical characteristics with high field-effect mobility (>200 cm{sup 2}/V·s), high drain-current I{sub on/off} ratio (>7 × 10{sup 4}), and small subthreshold slope (<100 mV/dec). These double-gate nanowire EDL transistors can pave the way for an electrically working low-voltage nano-electronic process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Protected gates for topological quantum field theories

We study restrictions on locality-preserving unitary logical gates for topological quantum codes in two spatial dimensions. A locality-preserving operation is one which maps local operators to local operators — for example, a constant-depth quantum circuit of geometrically local gates, or evolution for a constant time governed by a geometrically local bounded-strength Hamiltonian. Locality-preserving logical gates of topological codes are intrinsically fault tolerant because spatially localized errors remain localized, and hence sufficiently dilute errors remain correctable. By invoking general properties of two-dimensional topological field theories, we find that the locality-preserving logical gates are severely limited for codes which admit non-abelian anyons, in particular, there are no locality-preserving logical gates on the torus or the sphere with M punctures if the braiding of anyons is computationally universal. Furthermore, for Ising anyons on the M-punctured sphere, locality-preserving gates must be elements of the logical Pauli group. We derive these results by relating logical gates of a topological code to automorphisms of the Verlinde algebra of the corresponding anyon model, and by requiring the logical gates to be compatible with basis changes in the logical Hilbert space arising from local F-moves and the mapping class group.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A chimeric prokaryotic pentameric ligand–gated channel reveals distinct pathways of activation

Recent high resolution structures of several pentameric ligand–gated ion channels have provided unprecedented details of their molecular architecture. However, the conformational dynamics and structural rearrangements that underlie gating and allosteric modulation remain poorly understood. We used a combination of electrophysiology, double electron–electron resonance (DEER) spectroscopy, and x-ray crystallography to investigate activation mechanisms in a novel functional chimera with the extracellular domain (ECD) of amine-gated Erwinia chrysanthemi ligand–gated ion channel, which is activated by primary amines, and the transmembrane domain of Gloeobacter violaceus ligand–gated ion channel, which is activated by protons. We found that the chimera was independently gated by primary amines and by protons. The crystal structure of the chimera in its resting state, at pH 7.0 and in the absence of primary amines, revealed a closed-pore conformation and an ECD that is twisted with respect to the transmembrane region. Amine- and pH-induced conformational changes measured by DEER spectroscopy showed that the chimera exhibits a dual mode of gating that preserves the distinct conformational changes of the parent channels. Collectively, our findings shed light on both conserved and divergent features of gating mechanisms in this class of channels, and will facilitate the design of better allosteric modulators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ballistic Frenkel-exciton gate with a high on-off ratio

Here it is shown that the exciton interactions within organic dye aggregates, as modeled by the Frenkel Hamiltonian, enable the construction of an on/off switchable exciton gate. In this construction, a single exciton residing on a controlling gate molecule may pass or inhibit the ballistic propagation of an exciton in a proximal gate channel consisting of an array of dye molecules. High on-off ratios in excess of 102 can be achieved through the use of static difference dipole-dipole interactions between the gate and the gate channel which effectively creates a switchable Bragg grating. The gate channel and controlling gate molecule exhibit entanglement with the quantum mechanical superposition of the presence and absence of exciton occupation on the gate molecule.

74 ATOMIC AND MOLECULAR PHYSICS↗

Implementing two-qubit gates at the quantum speed limit

The speed of elementary quantum gates, particularly two-qubit gates, ultimately sets the limit on the speed at which quantum circuits can operate. In this work, we experimentally demonstrate commonly used two-qubit gates at nearly the fastest possible speed allowed by the physical interaction strength between two superconducting transmon qubits. We achieve this quantum speed limit by implementing experimental gates designed using a machine-learning-inspired optimal control method. Importantly, our method only requires the single-qubit drive strength to be moderately larger than the interaction strength to achieve an arbitrary two-qubit gate close to its analytical speed limit with high fidelity. Thus the method is applicable to a variety of platforms, including those with comparable single-qubit and two-qubit gate speeds, or those with always-on interactions. We expect our method to offer significant speedups for non-native two-qubit gates that are typically achieved with a long sequence of single-qubit and native two-qubit gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Current Source Gate Drive to Reduce Switching Loss for SiC MOSFETs

With conventional voltage source gate drives (VSG), the switching speed of SiC MOSFETs is difficult to increase due to large internal gate resistance, high Miller voltage, and limited gate voltage rating. This paper analyzes the requirement of current source gate drive (CSG) for SiC MOSFETs and proposes a CSG that can improve the switching speed and reduce switching loss. With the introduction of bi-directional switches, the influence of the large internal gate resistance of the SiC MOSFET can be mitigated, and sufficient gate current can be guaranteed throughout the switching transient. Therefore, the switching time and loss is reduced. The CSG can be controlled to be a VSG during steady state so the current of the gate drive is discontinuous and the stored energy of the inductor can be returned to the power supply to reduce gate drive loss. Double pulse tests are conducted for a SiC MOSFET with both conventional VSG and the proposed CSG. Testing results show that the switching loss of the proposed CSG is less than one third of the conventional VSG at full load condition.

Gui, Handong↗

Investigation of Single-Event Transients in AlGaN/GaN MIS-Gate HEMTs Using a Focused X-Ray Beam

Focused, pulsed X-rays are implemented to generate single-event transients (SETs) in metal-insulator-semiconductor (MIS)-gate AlGaN/GaN high-electron-mobility transistors (HEMTs) in order to examine the mechanisms responsible for SETs. Unlike Schottky-gate GaN HEMTs, where current flows between gate and drain when the device is biased "OFF," for the MIS-gate HEMTs, current flows between the source and drain. The presence of the SiNx insulating layer under the gate effectively blocks electrons on the gate from moving into the semiconductor. Short-duration SETs at the gate are caused by the collection of holes injected by the X-rays. SETs collected at the source and drain have an initial short-duration component, followed by a long-duration tail that can last for hundreds of nanoseconds. The long tails are due to positive charges (holes) that are less mobile than the electrons and so take longer to exit the HEMT, and to holes that become trapped at defects in the material. The holes lower the potential barrier between the source and the region under the gate, allowing for the injection of electrons that flow from the source to the drain. The durations of the SET tails are determined by the lifetimes of the trapped holes that are discovered to vary with X-ray photon energy and electrical bias.

36 MATERIALS SCIENCE↗

Improvement of Drain Breakdown Voltage with A Back-Side Gate on AlGaN/GaN High Electron Mobility Transistors

The effect of a back gate on the dc performance of AlGaN/GaN high electron mobility transistor was investigated. The back gate was fabricated directly under the device active area by etching off the Si substrate, AlN nucleation layer, and graded AlGaN transition layer and depositing Ni/Au-based gate metal on the exposed GaN buffer layer. The reverse bias gate leakage current decreased from 3.9 × 10 -5 to 1.2 × 10 -5 mA/mm by applying -10 V at the back gate. Because of the suppression of gate leakage current by the back gate, the drain on/off ratio improved from 1.8 × 10 5 to 1.2 × 10 6 and the subthreshold swing from 204 to 137 mV/dec. The drain breakdown voltage could be improved by 40% when the back gate was biased at -25 V.

42 ENGINEERING↗

Physiologically gated microbeam radiation using a field emission x-ray source array

Purpose: Microbeam radiation therapy (MRT) uses narrow planes of high dose radiation beams to treat cancerous tumors. This experimental therapy method based on synchrotron radiation has been shown to spare normal tissue at up to 1000 Gy of peak entrance dose while still being effective in tumor eradication and extending the lifetime of tumor-bearing small animal models. Motion during treatment can lead to significant movement of microbeam positions resulting in broader beam width and lower peak to valley dose ratio (PVDR), which reduces the effectiveness of MRT. Recently, the authors have demonstrated the feasibility of generating microbeam radiation for small animal treatment using a carbon nanotube (CNT) x-ray source array. The purpose of this study is to incorporate physiological gating to the CNT microbeam irradiator to minimize motion-induced microbeam blurring. Methods: The CNT field emission x-ray source array with a narrow line focal track was operated at 160 kVp. The x-ray radiation was collimated to a single 280 μm wide microbeam at entrance. The microbeam beam pattern was recorded using EBT2 Gafchromic{sup ©} films. For the feasibility study, a strip of EBT2 film was attached to an oscillating mechanical phantom mimicking mouse chest respiratory motion. The servo arm was put against a pressure sensor to monitor the motion. The film was irradiated with three microbeams under gated and nongated conditions and the full width at half maximums and PVDRs were compared. An in vivo study was also performed with adult male athymic mice. The liver was chosen as the target organ for proof of concept due to its large motion during respiration compared to other organs. The mouse was immobilized in a specialized mouse bed and anesthetized using isoflurane. A pressure sensor was attached to a mouse's chest to monitor its respiration. The output signal triggered the electron extraction voltage of the field emission source such that x-ray was generated only during a portion of the mouse respiratory cycle when there was minimum motion. Parallel planes of microbeams with 12.4 Gy/plane dose and 900 μm pitch were delivered. The microbeam profiles with and without gating were analyzed using γ-H2Ax immunofluorescence staining. Results: The phantom study showed that the respiratory motion caused a 50% drop in PVDR from 11.5 when there is no motion to 5.4, whereas there was only a 5.5% decrease in PVDR for gated irradiation compared to the no motion case. In thein vivo study, the histology result showed gating increased PVDR by a factor of 2.4 compared to the nongated case, similar to the result from the phantom study. The full width at tenth maximum of the microbeam decreased by 40% in gating in vivo and close to 38% with phantom studies. Conclusions: The CNT field emission x-ray source array can be synchronized to physiological signals for gated delivery of x-ray radiation to minimize motion-induced beam blurring. Gated MRT reduces valley dose between lines during long-time radiation of a moving object. The technique allows for more precise MRT treatments and makes the CNT MRT device practical for extended treatment.

60 APPLIED LIFE SCIENCES↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗