Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Development of CDZNTE Detectors for Low-Energy Gamma-Ray Astronomy

Under this grant the UC Berkeley PI, K. Hurley, joined a Goddard-led effort to develop large area, multi-pixel Cadmium-Zinc-Telluride (CdZnTe, or CZT) detectors for gamma-ray astronomy. His task was to advise the project of new developments in the area of cosmic gamma-ray bursts, in order to focus the detector development effort on the construction of an instrument which could be deployed on a spacecraft to localize and measure the energy spectra of bursts with good angular and energy resolution, respectively. UC Berkeley had no hardware role in this proposal. The result of this effort was the production, at Goddard, of five CZT prototype modules. A proposal was written for SWIFT, a MIDEX mission to study cosmic gamma-ray bursts. One experiment aboard SWIFT is the Burst Arcminute Telescope (BAT), which consists of a 5200 sq cm hard X-ray detector and a coded mask. The detector comprises 256 CZT modules, each containing 128 4 x 4 x 2 mm CZT detectors. Each detector is read out using an ASIC. The angular resolution achieved with this mask/array combination is 22 arcminutes, and a strong gamma-ray burst can be localized to an accuracy of 4 arcminutes in under 10 seconds. The energy resolution is typically 5 keV FWHM at 60 keV, and the energy range is 10 - 150 keV. The BAT views 2 steradians, and its sensitivity is such that the instrument can detect 350 gamma-ray burst/year, localizing 320 of them to better than 4 arcminute accuracy. The BAT concept therefore met the science goals for gamma-ray bursts. The UCB effort in the SWIFT proposal included the scientific objectives for gamma-ray bursts, and the assembly of a team of optical and radio observers who would use the BAT data to perform rapid multi-wavelength searches for the counterparts to bursts. This proposal was submitted to NASA and peer-reviewed. In January 1999 it was one of five such proposals selected for a Phase A study. This study was completed in June, and SWIFT was formally presented to NASA in September. It appeared that a final selection of two MIDEX missions for flight was imminent. However, the final selection was deferred at the last minute due to the uncertainty in NASA's OSS budget.

Gehrels, N.↗

Capabilities of GRO/OSSE for observing solar flares

The launch of the Gamma Ray Observatory (GRO) near solar maximum makes solar flare studies early in the mission particularly advantageous. The Oriented Scintillation Spectrometer Experiment (OSSE) on GRO, covering the energy range 0.05 to 150 MeV, has some significant advantages over the previous generation of satellite-borne gamma-ray detectors for solar observations. The OSSE detectors will have about 10 times the effective area of the Gamma-Ray Spectrometer (GRS) on Solar Maximum Mission (SMM) for both photons and high-energy neutrons. The OSSE also has the added capability of distinguishing between high-energy neutrons and photons directly. The OSSE spectral accumulation time (approx. 4s) is four times faster than that of the SMM/GRS; much better time resolution is available in selected energy ranges. These characteristics will allow the investigation of particle acceleration in flares based on the evolution of the continuum and nuclear line components of flare spectra, nuclear emission in small flares, the anisotropy of continuum emission in small flares, and the relative intensities of different nuclear lines. The OSSE observational program will be devoted primarily to non-solar sources. Therefore, solar observations require planning and special configurations. The instrumental and operational characteristics of OSSE are discussed in the context of undertaking solar observations. The opportunities for guest investigators to participate in solar flare studies with OSSE is also presented.

Kurfess, J. D.↗

HX-POL-A Balloon-Borne Hard X-Ray Polarimeter

We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-POL would allow us to measure the polarization of bright Crab-like sources for polarization degrees well below 10%. On a longer (15-30 day) flight from Australia or Antarctica, HX-POL would be be able to measure the polarization of bright galactic X-ray sources down to polarization degrees of a few percent. Hard X-ray polarization measurements provide unique venues for the study of particle acceleration processes by compact objects and relativistic outflows. In this paper, we discuss the overall instrument design and performance. Furthermore, we present results from laboratory tests of the Si and CZT detectors. Index Terms Gamma-ray astronomy, gamma-ray astronomy detectors, polarization, semiconductor radiation detectors, X-ray astronomy, X-ray astronomy detectors.

Krawczynski, H.↗

Germanium detector vacuum encapsulation

This paper describes an encapsulation technology that should significantly improve the viability of germanium gamma-ray detectors for a number of important applications. A specialized vacuum chamber has been constructed in which the detector and the encapsulating module are processed in high vacuum. Very high vacuum conductance is achieved within the valveless encapsulating module. The detector module is then sealed without breaking the chamber vacuum. The details of the vacuum chamber, valveless module, processing, and sealing method are presented.

Madden, N. W.↗

MeV Gamma Ray Detection Algorithms for Stacked Silicon Detectors

By making use of the signature of a gamma ray event as it appears in N = 5 to 20 lithium-drifted silicon detectors and applying smart selection algorithms, gamma rays in the energy range of 1 to 8 MeV can be detected with good efficiency and selectivity. Examples of the types of algorithms used for different energy regions include the simple sum mode, the sum-coincidence mode used in segmented detectors, unique variations on sum-coincidence for an N-dimensional vector event, and a new and extremely useful mode for double escape peak spectroscopy at pair-production energies. The latter algorithm yields a spectrum similar to that of the pair spectrometer, but without the need of the dual external segments for double escape coincidence, and without the large loss in efficiency of double escape events. Background events due to Compton scattering are largely suppressed. Monte Carlo calculations were used to model the gamma ray interactions in the silicon, in order to enable testing of a wide array of different algorithms on the event N-vectors for a large-N stack.

McMurray, Robert E. Jr.↗

Growth interface study of CdTeSe crystals grown by the THM technique

The Traveling Heater Method (THM) is a widely accepted technique to grow high-quality detector grade CdTe and CdZnTe ingots, especially for X-ray and gamma-ray detector applications. Unlike melt-growth techniques, the growth interface for ingots produced by the THM technique consists of two different compounds, viz. the solidified region (just below the interface) consists of the compound to be grown (e.g., CdZnTe for CdZnTe growth), while the molten zone just above the growth interface consists of Te-rich CdZnTe. Thus, optimization of the growth parameters is critical to obtain a clean growth interface with the required shape and presence of minimal Te-rich inclusions. Here, in this study, CdTeSe ingots were grown employing the THM technique to investigate the growth interface. Both macroscopic and microscopic behavior of the interface were studied. The study revealed that a microscopically smooth growth interface can be achieved by optimizing the growth parameters, which is essential for obtaining high-quality, inclusion-free ingots.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

GLAST and Ground-Based Gamma-Ray Astronomy

The launch of the Gamma-ray Large Area Space Telescope together with the advent of a new generation of ground-based gamma-ray detectors such as VERITAS, HESS, MAGIC and CANGAROO, will usher in a new era of high-energy gamma-ray astrophysics. GLAST and the ground based gamma-ray observatories will provide highly complementary capabilities for spectral, temporal and spatial studies of high energy gamma-ray sources. Joint observations will cover a huge energy range, from 20 MeV to over 20 TeV. The LAT will survey the entire sky every three hours, allowing it both to perform uniform, long-term monitoring of variable sources and to detect flaring sources promptly. Both functions complement the high-sensitivity pointed observations provided by ground-based detectors. Finally, the large field of view of GLAST will allow a study of gamma-ray emission on large angular scales and identify interesting regions of the sky for deeper studies at higher energies. In this poster, we will discuss the science returns that might result from joint GLAST/ground-based gamma-ray observations and illustrate them with detailed source simulations.

McEnery, Julie↗

High-Resolution Gamma-Ray Imaging Measurements Using Externally Segmented Germanium Detectors

Fully two-dimensional gamma-ray imaging with simultaneous high-resolution spectroscopy has been demonstrated using an externally segmented germanium sensor. The system employs a single high-purity coaxial detector with its outer electrode segmented into 5 distinct charge collection regions and a lead coded aperture with a uniformly redundant array (URA) pattern. A series of one-dimensional responses was collected around 511 keV while the system was rotated in steps through 180 degrees. A non-negative, linear least-squares algorithm was then employed to reconstruct a 2-dimensional image. Corrections for multiple scattering in the detector, and the finite distance of source and detector are made in the reconstruction process.

spectroscopy gamma ray germanium sensor nucleosynt↗

A New Measurement of the 60 keV Emission from Am-241 Using Metallic Magnetic Calorimeters

Here, we report a new measurement of the 60 keV transition from 241 Am. It uses a metallic magnetic calorimeter gamma-ray detector calibrated in the region around 60 keV by four accurately known X-rays and gamma rays from the decay of 169 Yb. We determine an energy of 59,539.3 ± 0.3 (stat) ± 0.3 (syst) eV, which is 1.6 ± 0.4 eV lower than the current literature value of 59,540.9 ± 0.1 eV. We discuss the sources of this uncertainty and approaches to address them.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of electron-hole pair creation energy in Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 quaternary semiconductor for room-temperature gamma-ray detection

We report the first-time measurement of the electron-hole pair (ehp) creation energy (W ehp ) in novel Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 (CZTS) quaternary semiconductor. CZTS in single crystalline form is poised to be the future of large-volume room-temperature gamma-ray detectors due to its excellent compositional homogeneity with highly reduced defects, high-Z (atomic number) constituents, wide bandgap (1.6 eV), and superior charge transport properties. Despite a great deal of study of the material and device properties since its inception, the W ehp in CZTS has not been measured experimentally. Accurate determination of W ehp is essential for calibration of the spectrometer and other theoretical calculations. In this study we have used an absolute calibration approach, which is based on an iterative approach that yields the Wehp as the best-fit parameter. Using a 241 Am alpha emitting radioisotope and a planar CZTS detector, the Wehp in CZTS was calculated to be 4.47 eV. The obtained value has been validated by accurately predicting the peak energy for gamma rays emitted by a 137 Cs source and read by a CZTS detector with different dimensions. The dependences of the calculated W ehp value on the detector dimensions, type of interaction, and effect of charge trapping are also discussed.

42 ENGINEERING↗

Simulation and Measurement of Absorbed Dose from 137 Cs Gammas Using a Si Timepix Detector

The TimePix readout chip is a hybrid pixel detector with over 65k independent pixel elements. Each pixel contains its own circuitry for charge collection, counting logic, and readout. When coupled with a Silicon detector layer, the Timepix chip is capable of measuring the charge, and thus energy, deposited in the Silicon. Measurements using a NIST traceable 137Cs gamma source have been made at Johnson Space Center using such a Si Timepix detector, and this data is compared to simulations of energy deposition in the Si layer carried out using FLUKA.

Stoffle, Nicholas↗

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioisotope Identification with List-Mode Gamma-Ray Data

This work explores the potential of utilizing temporal data from gamma-ray detectors, known as list-mode data, to enhance radioisotope identification. Traditional identification methods, which rely on full gamma-ray spectrum analysis, often require long dwell times and struggle with spectra containing similarly spaced spectral peaks. We hypothesize that by leveraging the probabilistic nature of nuclear decay and the time-encoded information from decay sequences and interactions with surrounding materials, we can improve classification accuracy over static spectral analysis. This research examines the temporal content of list-mode data through exploratory data analysis via correlation discovery and qualitative distribution analysis. Additionally, we propose a probabilistic classification model that can utilize spectral data, temporal data, or both to determine if the incorporation of temporal information improves radioisotope identification. Our findings suggest that the temporal information present in list-mode gamma-ray data has merit and should be further investigated to develop more robust and optimal methods for utilizing this temporal information in applications requiring radioisotope identification.

List-mode data↗

Radioisotope Identification with List-Mode Gamma Ray Data: A rigorous assessment on the value of temporal information applied to radioisotope identification.

This work explores the potential of utilizing temporal data from gamma-ray detectors, known as list-mode data, to enhance radioisotope identification. Traditional identification methods, which rely on full gamma-ray spectrum analysis, often require long dwell times and struggle with “confuser” sources, or spectra with similarly spaced spectral peaks. We hypothesize that by leveraging the probabilistic nature of nuclear decay and the time-encoded information from decay sequences and interactions with surrounding materials, we can improve classification accuracy over static spectral analysis. This research rigorously examines the temporal content of list-mode data through exploratory data analysis via correlation discovery and information theory. We further propose a basic classification model that can utilize spectral or temporal data (or both) to determine if the incorporation of temporal information can improve radioisotope identification. The findings suggest that the temporal information present in list-mode gamma-ray data has merit and should be further investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray observations of SN 1987A with an array of high-purity germanium detectors

A balloonborne gamma-ray spectrometer comprising an array of high-purity n-type germanium (HPGe) detectors surrounded by an active NaI(T1) collimator and Compton suppressing anticoincidence shield was flown on May 29-30, 1987. The average column depth of residual atmosphere in the direction of SN 1987A at float altitude was 6.3 g/sq cm during the observation. The 3-sigma upper limit obtained for the 1238-keV line from Co-56 is 0.0013 photons/sq cm s. The corresponding limit for the 847-keV line is 0.0017 photons/sq cm s.

Sandie, W. G.↗