Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Stellar atmosphere in statistical equilibrium

A static atmosphere with only Lyman continuum radiation in radiative equilibrium is studied for the effects of radiative and collisional ionization on deviations from local thermodynamic equilibrium (LTE). Large increases and decreases of the kinetic temperature (range in T of about factor 2) and, correspondingly, very large over- and underpopulation of the bound state (range in b of about factor 1,000,000) are found, depending on the frequency dependence of the photoionization cross section. Despite these large deviations from LTE, which strongly modify the emergent spectrum, there is almost no effect on the particle densities, the degree of ionization, and the basic structure of the atmosphere.

Kalkofen, W.↗

Effects of head-down bed rest on complex heart rate variability: Response to LBNP testing

Head-down bed rest is used to model physiological changes during spaceflight. We postulated that bed rest would decrease the degree of complex physiological heart rate variability. We analyzed continuous heart rate data from digitized Holter recordings in eight healthy female volunteers (age 28-34 yr) who underwent a 13-day 6 deg head-down bed rest study with serial lower body negative pressure (LBNP) trials. Heart rate variability was measured on a 4-min data sets using conventional time and frequency domain measures as well as with a new measure of signal 'complexity' (approximate entropy). Data were obtained pre-bed rest (control), during bed rest (day 4 and day 9 or 11), and 2 days post-bed rest (recovery). Tolerance to LBNP was significantly reduced on both bed rest days vs. pre-bed rest. Heart rate variability was assessed at peak LBNP. Heart rate approximate entropy was significantly decreased at day 4 and day 9 or 11, returning toward normal during recovery. Heart rate standard deviation and the ratio of high- to low-power frequency did not change significantly. We conclude that short-term bed rest is associated with a decrease in the complex variability of heart rate during LBNP testing in healthy young adult women. Measurement of heart rate complexity, using a method derived from nonlinear dynamics ('chaos theory'), may provide a sensitive marker of this loss of physiological variability, complementing conventional time and frequency domain statistical measures.

Goldberger, Ary L.↗

A continued fraction generator for smooth pulse sequences

Digital circuit produces rational output pulse rate at fraction of continuous input pulse rate. Output pulses have average rate with least possible deviation from absolute correct time spacing. Circuit uses include frequency synthesizing, fraction generation, and approximation of irrational sequences.

Cohn, M.↗

Single-Receiver GPS Phase Bias Resolution

Existing software has been modified to yield the benefits of integer fixed double-differenced GPS-phased ambiguities when processing data from a single GPS receiver with no access to any other GPS receiver data. When the double-differenced combination of phase biases can be fixed reliably, a significant improvement in solution accuracy is obtained. This innovation uses a large global set of GPS receivers (40 to 80 receivers) to solve for the GPS satellite orbits and clocks (along with any other parameters). In this process, integer ambiguities are fixed and information on the ambiguity constraints is saved. For each GPS transmitter/receiver pair, the process saves the arc start and stop times, the wide-lane average value for the arc, the standard deviation of the wide lane, and the dual-frequency phase bias after bias fixing for the arc. The second step of the process uses the orbit and clock information, the bias information from the global solution, and only data from the single receiver to resolve double-differenced phase combinations. It is called "resolved" instead of "fixed" because constraints are introduced into the problem with a finite data weight to better account for possible errors. A receiver in orbit has much shorter continuous passes of data than a receiver fixed to the Earth. The method has parameters to account for this. In particular, differences in drifting wide-lane values must be handled differently. The first step of the process is automated, using two JPL software sets, Longarc and Gipsy-Oasis. The resulting orbit/clock and bias information files are posted on anonymous ftp for use by any licensed Gipsy-Oasis user. The second step is implemented in the Gipsy-Oasis executable, gd2p.pl, which automates the entire process, including fetching the information from anonymous ftp

Bertiger, William I.↗

A Sub-THz CMOS Molecular Clock with 20 ppt Stability at 10,000 s Based on A Dual-Loop Spectroscopic Detection and Digital Frequency Error Integration

This paper presents a dual-loop chip-scale molecular clock (CSMC), which enhances the Allan Deviation performance by combining high signal-to-noise ratio of using fundamental mode and long-term stability of using higher order modes in derivative molecular absorption spectroscopy. In addition, digital frequency-error integration is adopted in the frequency-locked loop to provide an infinite open-loop DC gain, which fully suppresses any frequency drift caused by the temperature-sensitive crystal oscillator. This new generation CSMC is implemented in 65-nm CMOS, and achieves 20 ppt (part-per-trillion) Allan Deviation at 10,000 s averaging time with 71-mW power consumption.

Han, Ruonan↗

Performance of Planar-Waveguide External Cavity Laser for Precision Measurements

A 1542-nm planar-waveguide external cavity laser (PW-ECL) is shown to have a sufficiently low level of frequency and intensity noise to be suitable for precision measurement applications. The frequency noise and intensity noise of the PW-ECL was comparable or better than the nonplanar ring oscillator (NPRO) and fiber laser between 0.1 mHz to 100 kHz. Controllability of the PW-ECL was demonstrated by stabilizing its frequency to acetylene (13C2H2) at 10(exp -13) level of Allan deviation. The PW-ECL also has the advantage of the compactness of a standard butterfly package, low cost, and a simple design consisting of a semiconductor gain media coupled to a planar-waveguide Bragg reflector. These features would make the PW-ECL suitable for precision measurements, including compact optical frequency standards, space lidar, and space interferometry

Numata, Kenji↗

Direct driving of electronic and phononic degrees of freedom in a honeycomb bilayer with infrared light

Here, we study theoretically AB-stacked honeycomb bilayers driven by light in resonance with an infrared phonon within a tight-binding description. We characterize the phonon properties of honeycomb bilayers with group theory and construct an electronic time-dependent tight-binding model for the system following photoexcitation in resonance with an infrared phonon. We adopt an atomically adiabatic approximation [V. Mohanty and E. J. Heller, Proc. Natl. Acad. Sci. 116, 18316 (2019)] to describe classically vibrating nuclei, but obtain the Floquet quasienergy spectrum associated with the time-dependent model exactly. We introduce a general scheme to disentangle the complex low-frequency Floquet spectrum to elucidate the relevant Floquet bands. As a prototypical example, we consider bilayer graphene. We find that light in the low-frequency regime can induce a band gap in the quasienergy spectrum in the vicinity of the $K$ points even if it is linearly polarized, in contrast with the expectations within the Born-Oppenheimer approximation and the high-frequency regime. Finally, we analyze the diabaticity of the driven electron and driven phonon processes and find contrasting effects on the autocorrelation functions at the same driving frequency: Driven phonons preserve the character of the initial state while driven electrons exhibit strong deviations within a few drive cycles. The procedure outlined here can be applied to other materials to describe the combined effects of low-frequency light on phonons and electrons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Convergent Concordant Mode Approach for Molecular Vibrations: CMA-2

The concordant mode approach (CMA) is a promising new scheme for dramatically increasing the system size and level of theory achievable in quantum chemical computations of molecular vibrational frequencies. Here, we achieve advances in the CMA hierarchy by computations targeting CCSD(T)/cc-pVTZ (coupled cluster singles and doubles with perturbative triples using a correlation-consistent polarized-valence triple-ζ basis set) benchmarks within the G2 molecular test set, executing a statistical analysis for 1501 frequencies from 111 compounds and then separately solving the refractory case of pyridine. First, MP2/cc-pVTZ (second-order Møller–Plesset perturbation theory with the same basis set) proves to be an excellent and preferred choice for generating the underlying (Level B) normal modes of the CMA scheme. Utilizing this Level B within the CMA-0A method reproduces the 1501 benchmark frequencies with a mean absolute error (MAE) of only 0.11 cm –1 and an attendant standard deviation of 0.49 cm –1 . Second, a convergent CMA-2 method is constituted that allows efficient computation of higher level (Level A) frequencies to any reasonable accuracy threshold by using only Hartree–Fock (HF) and MP2 or density functional theory (DFT) data to generate ξ parameters, which select the sparse off-diagonal force field elements for explicit evaluation at Level A. When Level B = MP2/cc-pVTZ, a cutoff of ξ = 0.02 provides an average maximum absolute error per molecule of only 0.17 cm –1 by incurring merely a 33% increase in average cost over CMA-0A. This CMA-2 method also eradicates the 4 problematic CMA-0A outliers of pyridine with even less effort (ξ = 0.04, 22% increase). Finally, the newly developed CMA procedures are shown to be highly successful when applied to 1-(1H-pyrrol-3-yl)ethanol, a new test molecule with diverse types of vibration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Factors That Influence Variability in Stress-Drop Measurements Using Spectral Decomposition and Spectral-Ratio Methods for the 2019 Ridgecrest Earthquake Sequence

Stress drop is a fundamental parameter related to earthquake source physics, but is hard to measure accurately. To better understand how different factors influence stress-drop measurements, we compare two different methods using the Ridgecrest stress-drop validation data set: spectral decomposition (SD) and spectral ratio (SR), each with different processing options. Here, we also examine the influence of spectral complexity on source parameter measurement. Applying the SD method, we find that frequency bandwidth and time-window length could influence spectral magnitude calibration, while depth-dependent attenuation is important to correctly map stress-drop variations. For the SR method, we find that the selected source model has limited influence on the measurements; however, the Boatwright model tends to produce smaller standard deviation and larger magnitude dependence than the Brune model. Variance reduction threshold, frequency bandwidth, and time-window length, if chosen within an appropriate parameter range, have limited influence on source parameter measurement. For both methods, wave type, attenuation correction, and spectral complexity strongly influence the result. The scale factor that quantifies the magnitude dependence of stress drop show large variations with different processing options, and earthquakes with complex source spectra deviating from the Brune-type source models tend to have larger scale factor than earthquakes without complexity. Based on these detailed comparisons, we make a few specific suggestions for data processing workflows that could help future studies of source parameters and interpretations.

58 GEOSCIENCES↗

Semianalytic continuum spectra of Type 2 supernovae

We extend the approximate radiative transfer analysis of Hershkowitz, Linder, & Wagoner (1986) to a more general class of supernova model atmospheres, using a simple fit to the effective continuum opacity produced by lines (Wagoner, Perez, & Vasu 1991). At the low densities considered, the populations of the excited states of hydrogen are governed mainly by photoionization and recombination, and scattering dominates absorptive opacity. We match the asymptotic expressions for the spectral energy density J(sub nu) at the photosphere, whose location at each frequency is determined by a first-order calculation of the deviation of J(sub nu) from the Planck function B(sub nu). The emergent spectral luminosity then assumes the form L(sub nu) = 4 pi(squared)r(squared)(sub *) zeta(squared)B(sub nu)(T(sub p)), where T(sub p)(nu) is the photospheric temperature zeta is the dilution factor, and r(sub *) is a fiducial radius (ultimately taken to be the photospheric radius r(sub p)(nu)). The atmosphere is characterized by an effective temperature T(sub e) (varies as L(sup 1/4)r(sup -1/2)(sub *)) and hydrogen density n(sub H) = dependence of zeta on frequency nu and the parameters T(sub p), r(sub p), and alpha. The resulting understanding of the dependence of the spectral luminosity on observable parameters which characterize the relevant physical conditions will be of particular use in assessing the reliability of the expanding photosphere method of distance determination. This is particularly important at cosmological distances, where no information about the progenitor star will be available. This technique can also be applied to other low-density photosphere.

Montes, Marcos J.↗

Deep space FM system, a concept

Deep space frequency modulation system permits transmission of data where the signal deviation is greater than 1/2 the predetection bandwidth. It provides satisfactory performance at great distances or with low signal levels.

Doland, G. D.↗

Airoscope telemetry system

The AIROscope (Ames Infrared Observatory telescope) telemetry system is described from signal conditioning on the gondola to display and storage at the ground station. All analog and digital data from the systems and experiments on the gondola go to a PCM encoder which formats the data into 10-bit words. Therefore, 0.1-percent resolution is inherently available for experimental data. The coded bit stream directly modulates the carrier of the FM transmitter. To insure reliable transmission over a 650-km range an 11-watt FM transmitter operating at 1483.5 MHz is used on the gondola. Modulation is narrow band FM with a maximum deviation of plus or minus 500 kHz. The maximum modulation frequency is determined by the data bit rate which could be as high as 500 kbps. Presently, a rate of 20.48 kbps is used. The ground station receiving system includes a steerable antenna (19-db gain), preamplifier (21-db gain) and receiver. All data are recorded on a tape recorder. The recorded signal then can be played back through the PCM decommutator unit at a later time for detailed data analysis by the experimenter.

Pitts, K. J.↗

Unified Analysis for Antenna Pointing and Structural Errors. Part 1. Review

A necessary step in the design of a high accuracy microwave antenna system is to establish the signal error budget due to structural, pointing, and environmental parameters. A unified approach in performing error budget analysis as applicable to ground-based microwave antennas of different size and operating frequency is discussed. Major error sources contributing to the resultant deviation in antenna boresighting in pointing and tracking modes and the derivation of the governing equations are presented. Two computer programs (SAMCON and EBAP) were developed in-house, including the antenna servo-control program, as valuable tools in the error budget determination. A list of possible errors giving their relative contributions and levels is presented.

Abichandani, K.↗

High-resolution Fourier transform spectroscopy of the Meinel system of OH

The infrared spectrum of the hydroxyl radical OH, between 1850 and 9000/cm has been measured with a Fourier transform spectrometer. The source, a hydrogen-ozone diffusion flame, was designed to study the excitation of rotation-vibration levels of the OH Meinel bands under conditions similar to those in the upper atmosphere which produce the nighttime OH airglow emission. Twenty-three bands were observed: nine bands in the Delta upsilon = 1 sequence, nine bands in the Delta upsilon = 2 sequence, and five bands in the Delta upsilon = 3 sequence. A global nonlinear least-squares fit of 1696 lines yielded molecular parameters with a standard deviation of 0.003/cm. Term values are computed, and transition frequencies in the Delta upsilon = 3, 4, 5, 6 sequences in the near-infrared are predicted.

Abrams, Mark C.↗

Performance Enhancement of Tunable Bandpass Filters Using Selective Etched Ferroelectric Thin Films

The inclusion of voltage-tunable barium strontium titanate (BSTO) thin films into planar band pass filters offers tremendous potential to increase their versatility. The ability to tune the passband so as to correct for minor deviations in manufacturing tolerances, or to completely reconfigure the operating frequencies of a microwave communication system, are highly sought-after goals. However, use of ferroelectric films in these devices results in higher dielectric losses, which in turn increase the insertion loss and decrease the quality factors of the filters. This study explores the use of patterned ferroelectric layers to minimize dielectric losses without degrading tunability. Patterning the ferroelectric layers enables us to constrict the width of the ferroelectric layers between the coupled microstrip lines, and minimize losses due to ferroelectric layers. Coupled one-pole microstrip bandpass filters with fundamental resonances at approx. 7.2 GHz and well defined harmonic resonances at approx. 14.4 and approx. 21.6 GHz, were designed, simulated and tested. For one of the filters, experimental results verified that its center frequency was tunable by 528 MHz at a center frequency of 21.957 GHz, with insertion losses varying from 4.3 to 2.5 dB, at 0 and 3.5 V/micron, respectively. These data demonstrate that the tuning-to-loss figure of merit of tunable microstrip filters can be greatly improved using patterned ferroelectric thin films as the tuning element, and tuning can be controlled by engineering the ferroelectric constriction in the coupled sections.

Miranda, Felix A.↗

Heart rate dynamics in patients with stable angina pectoris and utility of fractal and complexity measures

Dynamic analysis techniques may uncover abnormalities in heart rate (HR) behavior that are not easily detectable with conventional statistical measures. However, the applicability of these new methods for detecting possible abnormalities in HR behavior in various cardiovascular disorders is not well established. Conventional measures of HR variability were compared with short-term (< or = 11 beats, alpha1) and long-term (> 11 beats, alpha2) fractal correlation properties and with approximate entropy of RR interval data in 38 patients with stable angina pectoris without previous myocardial infarction or cardiac medication at the time of the study and 38 age-matched healthy controls. The short- and long-term fractal scaling exponents (alpha1, alpha2) were significantly higher in the coronary patients than in the healthy controls (1.34 +/- 0.15 vs 1.11 +/- 0.12 [p <0.001] and 1.10 +/- 0.08 vs 1.04 +/- 0.06 [p <0.01], respectively), and they also had lower approximate entropy (p <0.05), standard deviation of all RR intervals (p <0.01), and high-frequency spectral component of HR variability (p <0.05). The short-term fractal scaling exponent performed better than other heart rate variability parameters in differentiating patients with coronary artery disease from healthy subjects, but it was not related to the clinical or angiographic severity of coronary artery disease or any single nonspectral or spectral measure of HR variability in this retrospective study. Patients with stable angina pectoris have altered fractal properties and reduced complexity in their RR interval dynamics relative to age-matched healthy subjects. Dynamic analysis may complement traditional analyses in detecting altered HR behavior in patients with stable angina pectoris.

NASA Discipline Cardiopulmonary↗