Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “framing camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Polarimetric Imaging using Two Photoelastic Modulators

A method of polarimetric imaging, now undergoing development, involves the use of two photoelastic modulators in series, driven at equal amplitude but at different frequencies. The net effect on a beam of light is to cause (1) the direction of its polarization to rotate at the average of two excitation frequencies and (2) the amplitude of its polarization to be modulated at the beat frequency (the difference between the two excitation frequencies). The resulting modulated optical light beam is made to pass through a polarizing filter and is detected at the beat frequency, which can be chosen to equal the frame rate of an electronic camera or the rate of sampling the outputs of photodetectors in an array. The method was conceived to satisfy a need to perform highly accurate polarimetric imaging, without cross-talk between polarization channels, at frame rates of the order of tens of hertz. The use of electro-optical modulators is necessitated by a need to obtain accuracy greater than that attainable by use of static polarizing filters over separate fixed detectors. For imaging, photoelastic modulators are preferable to such other electrio-optical modulators as Kerr cells and Pockels cells in that photoelastic modulators operate at lower voltages, have greater angular acceptances, and are easier to use. Prior to the conception of the present method, polarimetric imaging at frame rates of tens of hertz using photoelastic modulators was not possible because the resonance frequencies of photoelastic modulators usually lie in the range from about 20 to about 100 kHz.

Wang, Yu↗

Infrared Camera System for Visualization of IR-Absorbing Gas Leaks

Leak detection and location remain a common problem in NASA and industry, where gas leaks can create hazardous conditions if not quickly detected and corrected. In order to help rectify this problem, this design equips an infrared (IR) camera with the means to make gas leaks of IR-absorbing gases more visible for leak detection and location. By comparing the output of two IR cameras (or two pictures from the same camera under essentially identical conditions and very closely spaced in time) on a pixel-by-pixel basis, one can cancel out all but the desired variations that correspond to the IR absorption of the gas of interest. This can be simply done by absorbing the IR lines that correspond to the gas of interest from the radiation received by one of the cameras by the intervention of a filter that removes the particular wavelength of interest from the "reference" picture. This can be done most sensitively with a gas filter (filled with the gas of interest) placed in front of the IR detector array, or (less sensitively) by use of a suitable line filter in the same location. This arrangement would then be balanced against the unfiltered "measurement" picture, which will have variations from IR absorption from the gas of interest. By suitable processing of the signals from each pixel in the two IR pictures, the user can display only the differences in the signals. Either a difference or a ratio output of the two signals is feasible. From a gas concentration viewpoint, the ratio could be processed to show the column depth of the gas leak. If a variation in the background IR light intensity is present in the field of view, then large changes in the difference signal will occur for the same gas column concentration between the background and the camera. By ratioing the outputs, the same signal ratio is obtained for both high- and low-background signals, even though the low-signal areas may have greater noise content due to their smaller signal strength. Thus, one embodiment would use a ratioed output signal to better represent the gas column concentration. An alternative approach uses a simpler multiplication of the filtered signal to make the filtered signal equal to the unfiltered signal at most locations, followed by a subtraction to remove all but the wavelength-specific absorption in the unfiltered sample. This signal processing can also reveal the net difference signal representing the leaking gas absorption, and allow rapid leak location, but signal intensity would not relate solely to gas absorption, as raw signal intensity would also affect the displayed signal. A second design choice is whether to use one camera with two images closely spaced in time, or two cameras with essentially the same view and time. The figure shows the two-camera version. This choice involves many tradeoffs that are not apparent until some detailed testing is done. In short, the tradeoffs involve the temporal changes in the field picture versus the pixel sensitivity curves and frame alignment differences with two cameras, and which system would lead to the smaller variations from the uncontrolled variables.

Youngquist, Robert↗

Radiation Imaging with Event Camera

Neuromorphic or event-based imaging is a new, commercially available sensor technology inspired by how the human eye works. Instead of measuring frames at a fixed rate, the camera measures changes in pixel intensity asynchronously. This difference in readout architecture results in a high dynamic range and low latency. Event-based cameras have been used in a variety of applications, including object tracking, navigation, and lidar technologies. However, event-based cameras have not been adequately researched for their ability to image high-energy particles. This report explores the use of an event camera for imaging alpha, beta, and X-rays particles, when coupled with scintillator screens to convert high-energy particles into visible light. Methods to process event data were developed and are presented here, along with the results. The event camera can measure alpha and beta particles with comparable performance to that of a conventional camera. Event cameras can also image higher-activity sources and offer the possibility of discriminating particle interaction types on the basis of timing differences, which typical cameras cannot do. Additionally, event cameras can image objects with an X-ray source when the source strength dynamically changes but does not create a high-contrast image during static X-ray measurement.

47 OTHER INSTRUMENTATION↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

Mode shape analysis using a commercially available peak store video frame buffer

Time exposure photography, sometimes coupled with strobe illumination, is an accepted method for motion analysis that bypasses frame by frame analysis and resynthesis of data. Garden variety video cameras can now exploit this technique using a unique frame buffer that is a non-integrating memory that compares incoming data with that already stored. The device continuously outputs an analog video signal of the stored contents which can then be redigitized and analyzed using conventional equipment. Historically, photographic time exposures have been used to record the displacement envelope of harmonically oscillating structures to show mode shape. Mode shape analysis is crucial, for example, in aeroelastic testing of wind tunnel models. Aerodynamic, inertial, and elastic forces can couple together leading to catastrophic failure of a poorly designed aircraft. This paper will explore the usefulness of the peak store device as a videometric tool and in particular discuss methods for analyzing a targeted vibrating plate using the 'peak store' in conjunction with calibration methods familiar to the close-range videometry community. Results for the first three normal modes will be presented.

Snow, Walter L.↗

Reaching the Diffraction Limit - Differential Speckle and Wide-Field Imaging for the WIYN Telescope

Speckle imaging allows telescopes to achieve diffraction limited imaging performance. The technique requires cameras capable of reading out frames at a very fast rate, effectively 'freezing out' atmospheric seeing. The resulting speckles can be correlated and images reconstructed that are at the diffraction limit of the telescope. These new instruments are based on the successful performance and design of the Differential Speckle Survey Instrument (DSSI).The instruments are being built for the Gemini-N and WIYN telescopes and will be made available to the community via the peer review proposal process. We envision their primary use to be validation and characterization of exoplanet targets from the NASA, K2 and TESS missions and RV discovered exoplanets. Such targets will provide excellent follow-up candidates for both the WIYN and Gemini telescopes. We expect similar data quality in speckle imaging mode with the new instruments. Additionally, both cameras will have a wide-field mode and standard SDSS filters. They will be highly versatile instruments and it is that likely many other science programs will request time on the cameras. The limiting magnitude for speckle observations will remain around 13-14th at WIYN and 16-17th at Gemini, while wide-field, normal CCD imaging operation should be able to go to much fainter, providing usual CCD imaging and photometric capabilities. The instruments will also have high utility as scoring cameras for telescope engineering purposes, or other applications where high time resolution is needed. Instrument support will be provided, including a software pipeline that takes raw speckle data to fully reconstructed images.

detector↗

Apollo 12 photography 70 mm, 16 mm, and 35 mm frame index

For each 70-mm frame, the index presents information on: (1) the focal length of the camera, (2) the photo scale at the principal point of the frame, (3) the selenographic coordinates at the principal point of the frame, (4) the percentage of forward overlap of the frame, (5) the sun angle (medium, low, high), (6) the quality of the photography, (7) the approximate tilt (minimum and maximum) of the camera, and (8) the direction of tilt. A brief description of each frame is also included. The index to the 16-mm sequence photography includes information concerning the approximate surface coverage of the photographic sequence and a brief description of the principal features shown. A column of remarks is included to indicate: (1) if the sequence is plotted on the photographic index map and (2) the quality of the photography. The pictures taken using the lunar surface closeup stereoscopic camera (35 mm) are also described in this same index format.

Source record↗

Reaching the Diffraction Limit - Differential Speckle and Wide-Field Imaging for the Gemini-N Telescope

Speckle imaging allows telescopes to achieve di raction limited imaging performance. The technique requires cameras capable of reading out frames at a very fast rate, e ectively `freezing out' atmospheric seeing. The resulting speckles can be correlated and images reconstructed that are at the di raction limit of the telescope. These new instruments are based on the successful performance and design of the Di erential Speckle Survey Instrument (DSSI) [2, 1]. The instruments are being built for the Gemini-N and WIYN telescopes and will be made available to the community via the peer review proposal process. We envision their primary use to be validation and characterization of exoplanet targets from the NASA K2 and TESS missions and RV discovered exoplanets. Such targets will provide excellent follow-up candidates for both the WIYN and Gemini telescopes [3]. Examples of DSSI data are shown in the gures below. We expect similar data quality in speckle imaging mode with the new instruments. Additionally, both cameras will have a wide- eld mode and standard SDSS lters. They will be highly versatile instruments and it is that likely many other science programs will request time on the cameras. The limiting magnitude for speckle observations, will remain around 13-14th at WIYN and 16-17th at Gemini, while wide- eld, normal CCD imaging operation should be able to go to much fainter, providing usual CCD imaging and photometric capabilities. The instruments will also have high utility as scoring cameras for telescope engineering purposes, or other applications where high time resolution is needed. Instrument support will be provided, including a software pipeline that takes raw speckle data to fully reconstructed images.

Gemini-N↗

Advanced High-Definition Video Cameras

A product line of high-definition color video cameras, now under development, offers a superior combination of desirable characteristics, including high frame rates, high resolutions, low power consumption, and compactness. Several of the cameras feature a 3,840 2,160-pixel format with progressive scanning at 30 frames per second. The power consumption of one of these cameras is about 25 W. The size of the camera, excluding the lens assembly, is 2 by 5 by 7 in. (about 5.1 by 12.7 by 17.8 cm). The aforementioned desirable characteristics are attained at relatively low cost, largely by utilizing digital processing in advanced field-programmable gate arrays (FPGAs) to perform all of the many functions (for example, color balance and contrast adjustments) of a professional color video camera. The processing is programmed in VHDL so that application-specific integrated circuits (ASICs) can be fabricated directly from the program. ["VHDL" signifies VHSIC Hardware Description Language C, a computing language used by the United States Department of Defense for describing, designing, and simulating very-high-speed integrated circuits (VHSICs).] The image-sensor and FPGA clock frequencies in these cameras have generally been much higher than those used in video cameras designed and manufactured elsewhere. Frequently, the outputs of these cameras are converted to other video-camera formats by use of pre- and post-filters.

Glenn, William↗

Application of Digital Image Correlation in Wind Tunnel

Digital image correlation (DIC) is a non-contact measurement technique that has been used in various applications in multiple industries, from microscopic specimens all the way to large scale structures. This project involved using DIC to capture wing deflection under simulated wind loading at various angles of attack (AoA). A subscale model of a fixed-wing aircraft, shown in Figure 1, was used in the 14-footby 22-footsubsonicwind tunnel at the NASA Langley Research Center. The setup used two pairs of cameras mounted on the ceiling of the tunnel to view the starboard and port side wings. Aluminum framing was used to rigidly mount the cameras to beams in the ceiling. Camera setup challenges due to the confined space included obtaining even lighting and working around infrared (IR) cameras that were used to capture the flow over the wing. Remote connection was used to access data acquisition computers from computers in the control room. Eight measurement locations on each wing were made of 1-inch-diametercircular silver dry transfer decals that did not alter the air flow across the wing. These circles were speckled with a black ink pen and were used for the IR camera as well as for DIC systems. A mock setup outside the wind tunnel was used to optimize the camera setup and verify that the speckled tape provided sufficient correlation. DIC was used to track the position of seven locations as the AoA of the subscale model changed from −10 degrees to +10 degrees in 1-degree increments. The model was rotated at a fixed height about the center of the fuselage from −7 degrees to +10 degrees. The height of the model had to be lowered to achieve AoA slower than −7degrees due to geometric constraints of the cart supporting the model and the wind tunnel. The source of light was stationary relative to the model, so the exposure time had to be adjusted for different wing regions and AoA values. The three-dimensional (3D) visualization of the markings and the two-dimensional (2D) projection of these points onto the port wing at 0-degree AoA is shown in Figure 2.

Matlock Mennu↗

Dictionary Learning with Accumulator Neurons

The Locally Competitive Algorithm (LCA) uses local competition between non-spiking leaky integrator neurons to infer sparse representations, allowing for potentially real-time execution on massively parallel neuromorphic architectures such as Intel's Loihi processor. Here, we focus on the problem of inferring sparse representations from streaming video using dictionaries of spatiotemporal features optimized in an unsupervised manner for sparse reconstruction. Non-spiking LCA has previously been used to achieve unsupervised learning of spatiotemporal dictionaries composed of convolutional kernels from raw, unlabeled video. We demonstrate how unsupervised dictionary learning with spiking LCA (\hbox{S-LCA}) can be efficiently implemented using accumulator neurons, which combine a conventional leaky-integrate-and-fire (\hbox{LIF}) spike generator with an additional state variable that is used to minimize the difference between the integrated input and the spiking output. We demonstrate dictionary learning across a wide range of dynamical regimes, from graded to intermittent spiking, for inferring sparse representations of both static images drawn from the CIFAR database as well as video frames captured from a DVS camera. On a classification task that requires identification of the suite from a deck of cards being rapidly flipped through as viewed by a DVS camera, we find essentially no degradation in performance as the LCA model used to infer sparse spatiotemporal representations migrates from graded to spiking. We conclude that accumulator neurons are likely to provide a powerful enabling component of future neuromorphic hardware for implementing online unsupervised learning of spatiotemporal dictionaries optimized for sparse reconstruction of streaming video from event based DVS cameras.

artificial intelligence↗

Crystallization kinetics and thermodynamics of an Ag–In–Sb–Te phase change material using complementary in situ microscopic techniques

The crystallization of an amorphous Ag–In–Sb–Te (AIST) phase change material (PCM) is studied using multiple in situ imaging techniques to directly quantify crystal growth rates over a broad range of temperatures. The measurable growth rates span from ≈ 10 –9 to ≈ 20 m/s. Recent results using dynamic transmission electron microscopy (TEM), a photoemission TEM technique, and TEM with sub-framed imaging are reported here and placed into the context of previous growth rate measurements on AIST. Dynamic TEM experiments show a maximum observed crystal growth rate for as-deposited films to be > 20 m/s. It is shown that crystal growth above the glass transition can be imaged in a TEM through use of subframing and a high-frame-rate direct electron detection camera. Challenges associated with the determination of temperature during in situ TEM experiments are described. Finally, preliminary nanocalorimetry results demonstrate the feasibility of collecting thermodynamic data for crystallization of PCMs with simultaneous TEM imaging.

36 MATERIALS SCIENCE↗

Artificial solar eclipse experiment MA-148

On July 19, 1975, the Apollo spacecraft successfully occulted the solar disk from the field of view of a camera mounted in the Soyuz spacecraft while performing a spacecraft separation maneuver to permit the outer solar corona to be viewable by the Soyuz camera. The camera operated automatically, and 55 frames were developed for scientific analysis.

Giuli, R. T.↗

Full color hybrid display for aircraft simulators

A full spectrum color monitor, connected to the camera and lens system of a television camera supported by a gantry frame over a terrain model simulating an aircraft landing zone, projects the monitor image onto a lens or screen visually accessible to a trainee in the simulator. A digital computer produces a pattern corresponding to the lights associated with the landing strip onto a monochromatic display, and an optical system projects the calligraphic image onto the same lens so that it is superposed on the video representation of the landing field. The optical system includes a four-color wheel which is rotated between the calligraphic display and the lens, and an apparatus for synchronizing the generation of a calligraphic pattern with the color segments on the color wheel. A servo feedback system responsive to the servo motors on the gantry frame produces an input to the computer so that the calligraphically generated signal corresponds in shape, size and location to the video signal.

Chase, W. D.↗

Space and time resolved emission of hard X-rays from a plasma focus

The X-ray emission from focused plasmas was observed with an image converter camera in the streak and framing modes. Use of a very high gain image intensifier enabled weak hard X-ray emission (above 25 keV) to be recorded. The use of an admixture of higher atomic number into the deuterium was avoided, and the role of the vapor from the anode surface could be discerned. The recorded bremsstrahlung emission seemed to be from a metallic plasma of copper released from the anode surface by bombardment from an intense electron beam. The intensity of emission was determined by the density of copper and the density and energy of the electron beam. The main emission recorded occurred several 100 nsec after the focus was over, which implies that the electric fields driving the beam existed for this duration. It is suggested that the fields were created by annihilation of magnetic flux for a time much longer than the focus duration.

Harries, W. L.↗

Shock induced radiation from minerals

Schmitt and Ahrens (1983) have concluded that the type of optical emission produced during shock compression was dependent upon phase changes taking place during shock compression. The present study is concerned with new observations of shock-induced optical radiation from Al2O3, MgO, NaCl, KCl, x-cut and fused SiO2, and LiF at various pressures up to 75 GPa. The experimental setup used in the study is similar to that employed by Schmitt and Ahrens. An Image Converter Camera with a three-frame plug-in unit was added to take two or three exposures of the radiation field during shock wave propagation through the sample, taking into account exposure times in the range from 50 to 500 nsec. The greybody emissions observed in LiF, which undergoes no phase transition, imply that localized heating and perhaps melting occurs in this material during shock deformation.

Schmitt, D.↗

Multicolor pyrometer for materials processing in space

This report documents the work performed by Physical Sciences Inc. (PSI), under contract to NASA JPL, during a 2.5-year SBIR Phase 2 Program. The program goals were to design, construct, and program a prototype passive imaging pyrometer capable of measuring, as accurately as possible, and controlling the temperature distribution across the surface of a moving object suspended in space. These goals were achieved and the instrument was delivered to JPL in November 1989. The pyrometer utilizes an optical system which operates at short wavelengths compared to the peak of the black-body spectrum for the temperature range of interest, thus minimizing errors associated with a lack of knowledge about the heated sample's emissivity. To cover temperatures from 900 to 2500 K, six wavelengths are available. The preferred wavelength for measurement of a particular temperature decreases as the temperature increases. Images at all six wavelengths are projected onto a single CCD camera concurrently. The camera and optical system have been calibrated to relate the measured intensity at each pixel to the temperature of the heated object. The output of the camera is digitized by a frame grabber installed in a personal computer and analyzed automatically to yield temperature information. The data can be used in a feedback loop to alter the status of computer-activated switches and thereby control a heating system.

Frish, M. B.↗

Photographic Investigation of Combustion in a Two-dimensional Transparent Rocket Engine

Motion pictures at camera speeds up to 3000 frames per second were taken of the combustion of liquid oxygen and gasoline in a 100-pound thrust rocket engine. The effect of seven methods of propellant injection on the uniformity of combustion was investigated. The flame front was generally found to extend to the injector faces and all the injection systems showed considerable nonuniformity of combustion. Pressure vibration records indicated combustion vibrations that corresponded to resonant-chamber frequencies.

Bellman, Donald R↗