Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fluid bubbles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Stereo Imaging Velocimetry

Stereo imaging velocimetry (SIV) will permit the collection of quantitative, three-dimensional flow data from any optically transparent fluid that can be seeded with tracer particles. This includes such diverse experiments as the study of multiphase flow, bubble nucleation and migration, pool combustion, and crystal growth. This technique will be useful to the microgravity science community as our investigations of fluid behavior in reduced-gravity environments enhance our knowledge of heat transfer, surface tension, concentration-gradient-driven anomalies, and residual effects from g-jitter. In its proposed configuration, the NASA Lewis Research Center's Stereo Imaging Velocimeter will consist of at least two charged coupled device (CCD) cameras, oriented at some relative angle with respect to each other. The cameras will observe a fluid experiment that has been seeded with tracer particles that are neutrally buoyant to permit accurate flow tracking. Except for the tracer particles, this measurement technique will be nonintrusive. Velocity accuracies will be on the order of 1 to 5 percent of full field. Each camera will make a two-dimensional record of the motion of the seed particles in the observation volume. Three-dimensional data will be obtained by computationally combining the two-dimensional information.

Source record↗

Thermocapillary migration of bubbles and droplets

A discussion is presented concerning the motion of droplets in a surrounding fluid induced by a temperature gradient. Such 'thermocapillary migration' may be characterized as the tangential stress at the interface that is induced by the temperature gradient's variation of interfacial tension, causing motion in the neighboring fluid both inside and outside the droplet. As a result, the droplet moves in the direction of the pole with the lower interfacial tension. An analysis is conducted in the creeping flow limit, for the case of small Marangoni number values. The method of matched asymptotic expansions is used for the solution of the field equations.

Subramanian, R. S.↗

Experimental Investigation of Pool Boiling Heat Transfer Enhancement in Microgravity in the Presence of Electric Fields

In boiling high heat fluxes are possible driven by relatively small temperature differences, which make its use increasingly attractive in aerospace applications. The objective of the research is to develop ways to overcome specific problems associated with boiling in the low gravity environment by substituting the buoyancy force with the electric force to enhance bubble removal from the heated surface. Previous studies indicate that in terrestrial applications nucleate boiling heat transfer can be increased by a factor of 50, as compared to values obtained for the same system without electric fields. The goal of our research is to experimentally explore the mechanisms responsible for EHD heat transfer enhancement in boiling in low gravity conditions, by visualizing the temperature distributions in the vicinity of the heated surface and around the bubble during boiling using real-time holographic interferometry (HI) combined with high-speed cinematography. In the first phase of the project the influence of the electric field on a single bubble is investigated. Pool boiling is simulated by injecting a single bubble through a nozzle into the subcooled liquid or into the thermal boundary layer developed along the flat heater surface. Since the exact location of bubble formation is known, the optical equipment can be aligned and focused accurately, which is an essential requirement for precision measurements of bubble shape, size and deformation, as well as the visualization of temperature fields by HI. The size of the bubble and the frequency of bubble departure can be controlled by suitable selection of nozzle diameter and mass flow rate of vapor. In this approach effects due to the presence of the electric field can be separated from effects caused by the temperature gradients in the thermal boundary layer. The influence of the thermal boundary layer can be investigated after activating the heater at a later stage of the research. For the visualization experiments a test cell was developed. All four vertical walls of the test cell are transparent, and they allow transillumination with laser light for visualization experiments by HI. The bottom electrode is a copper cylinder, which is electrically grounded. The copper block is heated with a resistive heater and it is equipped with 6 thermocouples that provide reference temperatures for the measurements with HI. The top electrode is a mesh electrode. Bubbles are injected with a syringe into the test cell through the bottom electrode. The working fluids presently used in the interferometric visualization experiments, water and PF 5052, satisfy requirements regarding thermophysical, optical and electrical properties. A 30kV power supply equipped with a voltmeter allows to apply the electric field to the electrodes during the experiments. The magnitude of the applied voltage can be adjusted either manually or through the LabVIEW data acquisition and control system connected to a PC. Temperatures of the heated block are recorded using type-T thermocouples, whose output is read by a data acquisition system. Images of the bubbles are recorded with 35mm photographic and 16mm high-speed cameras, scanned and analyzed using various software packages. Visualized temperature fields HI allows the visualization of temperature fields in the vicinity of bubbles during boiling in the form of fringes. Typical visualized temperature distributions around the air bubbles injected into the thermal boundary layer in PF5052 are shown. The temperature of the heated surface is 35 C. The temperature difference for a pair of fringes is approximately 0.05 C. The heat flux applied to the bottom surface is moderate, and the fringe patterns are regular. In the image a bubble penetrating the thermal boundary layer is visible. Because of the axial symmetry of the problem, simplified reconstruction techniques can be applied to recover the temperature field. The thermal plume developing above the heated surface for more intensive heating is shown. The temperature distribution in the liquid is clearly 3D, and tomographic techniques have to be applied to recover the temperature distribution in such a physical situation. A sequence of interferometric images showing the temperature distribution around the rising bubble, recorded with a high-speed camera is shown. Again, the temperature distribution is 3D, and a more complex approach to the evaluation, the tomographic reconstruction has to be taken. Measurement of the temperature distribution from the fringe pattern temperature distributions that yield important information regarding heat transfer are determined. Two algorithms that allow the quantitative evaluation of interferometric fringe patterns and the reconstruction of temperature fields during boiling have been developed at the Heat Transfer Laboratory of the Johns Hopkins University. In the first algorithm the bubble is assumed to be axially symmetrical, which significantly reduces the computational effort for quantifying the temperature distribution around the bubble. For this purpose the thermal boundary layer around the bubble is divided into equidistant concentric shells, and the refractive index is assumed to be constant in each of the shells. Since large temperature gradients are expected in the vicinity of the bubble during boiling, the deflection of the light beam cannot be neglected in boiling experiments. Since the exit angle of the light beam is known, this allows to account for the deflections and phase shifts outside the boundary layer (in the bulk fluid and in the windows of the test cell). Three dimensional temperature distributions in the vicinity of the bubble are reconstructed using tomographic techniques. In tomography, the measurement volume is sliced into 2D planes. In the present study these planes are parallel to the heated surface. The objective is to determine the values of the field parameter of interest in form of the field function in these 2D planes. The field parameter is the change of the refractive index of the liquid in the measurement volume caused by temperature changes. By superimposing data for many 2D planes recorded at the same time instant, the 3D temperature distribution in the measurement volume is recovered.

Herman, Cila↗

Sizing and Selection of Pressure Relief Valves for High-Pressure Thermal–Hydraulic Systems

This study covers the critical concerns related to the sizing, selection, installation, maintenance, and testing of pressure safety valves (PSVs). The aim is to ensure the safety of pressurized systems, hydrostatic transmission systems, and hydraulic plants, including process plants, thermal power plants, and nuclear reactor systems. PSVs are devices that ensure the safety and reliability of pressurized vessels, lines, and systems during overpressure events. The task of selecting which PSV features are of greatest value for a specific purpose is complex—especially in the design of a high-pressure experimental thermal–hydraulic facility for hydrostatic and transient testing of the reactor system—when the systems are in the design and development phases and require qualification and demonstration to prove that they have reached a given level of technological readiness. The present study highlights the required steps for users to follow the associated rules, guidelines, and recommendations. As a part of this research, case studies are presented to help readers better understand the applicable strategy and standards. A discussion and a review of PSV performance degradation and failure are summarized to provide a better understanding of varied process applications and conditions, including fluid flow dynamics, boundary-layer formation and pressure drops, gas bubble formation and collapse, geometric configurations, inlet/outlet piping, abrupt pressure fluctuations, and acoustic resonance. Moreover, this study discusses the servicing and testing of PSVs in a multiphase pressurized system. Overall, it provides a basic overview of how PSVs ensure the safety of pressurized systems, supported by case studies and industrial practices.

02 PETROLEUM↗

In-flight flow visualization with pressure measurements at low speeds on the NASA F-18 high alpha research vehicle

In-flight results from surface and off-surface flow visualizations and from extensive pressure distributions document the vortical flow on the leading edge extensions (LEX) and forebody of the NASA F-18 high alpha research vehicle for low speeds and angles of attack up to 50 degs. Surface flow visualization data, obtained using the emitted fluid technique, were used to define separation lines and laminar separation bubbles. Off-surface flow visualization data, obtained by smoke injection, were used to document both the path of the vortex cores and the location of vortex core breakdown. The location of vortex core breakdown correlated well with the loss of suction pressure on the LEX and with the flow visualization results from ground facilities. Surface flow separation lines on the LEX and forebody corresponded well with the end of pressure recovery under the vortical flows. Correlation of the pressures with wind tunnel results show fair to good correlation.

Delfrate, John H.↗

In-flight flow visualization and pressure measurements at low speeds on the NASA F-18 high alpha research vehicle

Inflight results from surface and off surface flow visualizations and from extensive pressure distributions document the vortical flow on the leading edge extensions (LEXs) and forebody of the NASA F-18 high alpha research vehicle (HARV) for low speeds and angles of attack up to 50 deg. Surface flow visualization data, obtained using the emitted fluid technique, were used to define separation lines and laminar separation bubbles (LSB). Off surface flow visualization data, obtained by smoke injection, were used to document both the path of the vortex cores and the location of vortex core breakdown. The location of vortex core breakdown correlated well with the loss of suction pressure on the LEX and with the flow visualization results from ground facilities. Surface flow separation lines on the LEX and forebody corresponded well with the end of pressure recovery under the vortical flows. Correlation of the pressures with wind tunnel results show fair to good correlation.

John H Del Frate↗

Liquid Acquisition Device Testing with Sub-Cooled Liquid Oxygen

When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth s gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMD) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. Previous experimental test programs conducted at NASA have collected LAD data for a number of cryogenic fluids, including: liquid nitrogen (LN2), liquid oxygen (LOX), liquid hydrogen (LH2), and liquid methane (LCH4). The present work reports on additional testing with sub-cooled LOX as part of NASA s continuing cryogenic LAD development program. Test results extend the range of LOX fluid conditions examined, and provide insight into factors affecting predicting LAD bubble point pressures.

Jurns, John M.↗

Cavitation in a soft porous material

Abstract We study the collapse and expansion of a cavitation bubble in a deformable porous medium. We develop a continuum-scale model that couples compressible fluid flow in the pore network with the elastic response of a solid skeleton. Under the assumption of spherical symmetry, our model can be reduced to an ordinary differential equation that extends the Rayleigh–Plesset equation to bubbles in soft porous media. The extended Rayleigh–Plesset equation reveals that finite-size effects lead to the breakdown of the universal scaling relation between bubble radius and time that holds in the infinite-size limit. Our data indicate that the deformability of the porous medium slows down the collapse and expansion processes, a result with important consequences for wide-ranging phenomena, from drug delivery to spore dispersion.

Leng, Yu↗

Fluid surface behavior in low gravity. Center discretionary fund no. 83-21

Measurements of rotating equilibrium bubble shapes in the low-gravity environment of a free-falling aircraft are presented. Emphasis is placed on bubbles which intersect the container boundaries. These data are compared with theoretical profiles derived from Laplace's formula and are in good agreement with the measurements. Two types of instability are explored. The first occurs when the baffle spacing is too large for the bubble to intersect both the top and bottom boundaries. The second occurs when the hydrostatic pressure beneath a displaced free surface does not compensate for pressure change due to capillary forces. The interface shape depends on the contact angle, the radius of intersection with container, and the parameter F which is a measure of the relative importance of centrifugal force to surface tension. For isolated bubbles, F has a maximum value of 1/2. A further increase in F causes the bubble to break contact with the axis of rotation. For large values of F, the bubble becomes more cylindrical and the capillary rise occurs over a thinner layer so that the small radius of curvature can generate enough pressure drop to balance the increased hydrostatic contribution.

Leslie, F.↗

Gravity Effects in Diffusive Coarsening of Bubble Lattices: von Neumann's Law

von Neumann modelled the evolution of two-dimensional soap froths as a purely diffusive phenomenon; the area growth of a given cell was found to depend only on the geometry of the bubble lattice. In the model, hexagons are stable, pentagons shrink and heptagons grow. The simplest equivalent to the area growth law is / approximately t(sub beta). The result depends on assuming (1) an incompressible gas; (2) bubble walls which meet at 120 deg and (3) constant wall thickness and curvature. Each assumption is borne out in experiments except the last one: bubble wall thickness between connecting cells varies in unit gravity because of gravity drainage. The bottom part of the soap membrane is thickened, the top part is thinned, such that gas diffusion across the membrane shows a complex dependence on gravity. As a result, experimental tests of von Neumann's law have been influenced by effects of gravity; fluid behavior along cell borders can give non-uniform wall thicknesses and thus alter the effective area and gas diffusion rates between adjacent bubbles. For area plotted as a function of time, Glazier (J.A. Glazier, S.P. Gross, and I. Stavans, Phys. Rev. A. 36, 306 (1987); J. Stavans, J.A, Glazier, Phys. Rev. Lett. 62, 1318 (1989).) suggest that in some cases their failure to observe von Neumann's predicted growth exponent ((sup beta)theor(sup =1; beta)exp(sup =0.70 + 0.10)) may have been the result of such "fluid drainage onto the lower glass plate". Additional experiments which varied plate spacing gave different beta exponents in a fashion consistent with this suggestion. During preliminary long duration experiments (approximately 100 h) aboard Spacelab-J, a low-gravity test of froth coarsening has examined (1) power law scaling of von Neumann's law (beta values) in the appropriate diffusive limits; (2) new bubble lattice dynamics such as greater fluid wetting behavior on froth membranes in low gravity; and (3) explicit relations for the gravity dependence of the second moment (or disorder parameter) governing the geometric spread in cell-sidedness around the mean of perfect hexagonal filling. By reducing the gravity-induced distortion in lattice wall thickness, the diffusion-limited regime of bubble coarsening becomes available for performing critical tests of network dynamics.

Noever, David A.↗

Fundamentals of Plasma Sails Propulsion Concept

The Mini-Magnetospheric Plasma Propulsion (M2P2), originally proposed by Winglee et al. [2000], is based on the two-fluid plasma model and requires a 15-km frontal standoff distance (or 20-km cross-sectional diameter) in order for the magnetic bubble to absorb sufficient momentum from the SW to accelerate a spacecraft to the unprecedented speeds of 50-80 km/s after an acceleration period of about three months. Winglee et al. [2000] derived the above size requirement based on an extrapolation of their simulated results in which a system much smaller than a M2P2 was used (p. 21,074 of their study). We submit, however, that a fluid model has no validity for such a small scale size-even in the region near the plasma source! It is assumed in the MHD fluid model, normally applied to the magnetosphere, that the characteristic scale-size is much greater than the Larmor radius and ion skin depth of the SW. In the case of the M2P2, however, the size of the magnetic bubble is actually less than or, at best, comparable to, the scale of these characteristic parameters and, therefore, a kinetic approach, which addresses the smallscale physical mechanisms involved, must be used. A fully three-dimensional version of the hybrid code is used in our M2P2 (Plasma Sails) studies was originally developed by Delamere et al. [1999]. The M2P2 plasma sail is an excellent application for this hybrid code. The primary advantage of this code is the seamless interface between fluid and kinetic descriptions of the ion populations. A kinetic description is not necessary for the dense inner regions of the magnetic bubble and tremendous computational savings can be realized by treating this dense, magnetized ion population with the fluid description. It is essential, however, that the outer bubble regions be treated kinetically as well as the SW protons. Comparison of full size M2P2 simulation based on 3D MHD and kinetic models show that kinetic treatment introduces much more asymmetry to the considering problem and the possibility of kinetic instabilities development.

Khazanov, G. V.↗

Constrained Vapor Bubble

The nonisothermal Constrained Vapor Bubble, CVB, is being studied to enhance the understanding of passive systems controlled by interfacial phenomena. The study is multifaceted: 1) it is a basic scientific study in interfacial phenomena, fluid physics and thermodynamics; 2) it is a basic study in thermal transport; and 3) it is a study of a heat exchanger. The research is synergistic in that CVB research requires a microgravity environment and the space program needs thermal control systems like the CVB. Ground based studies are being done as a precursor to flight experiment. The results demonstrate that experimental techniques for the direct measurement of the fundamental operating parameters (temperature, pressure, and interfacial curvature fields) have been developed. Fluid flow and change-of-phase heat transfer are a function of the temperature field and the vapor bubble shape, which can be measured using an Image Analyzing Interferometer. The CVB for a microgravity environment, has various thin film regions that are of both basic and applied interest. Generically, a CVB is formed by underfilling an evacuated enclosure with a liquid. Classification depends on shape and Bond number. The specific CVB discussed herein was formed in a fused silica cell with inside dimensions of 3x3x40 mm and, therefore, can be viewed as a large version of a micro heat pipe. Since the dimensions are relatively large for a passive system, most of the liquid flow occurs under a small capillary pressure difference. Therefore, we can classify the discussed system as a low capillary pressure system. The studies discussed herein were done in a 1-g environment (Bond Number = 3.6) to obtain experience to design a microgravity experiment for a future NASA flight where low capillary pressure systems should prove more useful. The flight experiment is tentatively scheduled for the year 2000. The SCR was passed on September 16, 1997. The RDR is tentatively scheduled for October, 1998.

Huang, J.↗

Analysis of dynamic characteristics of fluid force induced by labyrinth seal

Flow patterns of the labyrinth seal are experimentally investigated for making a mathematical model of labyrinth seal and to obtain the flow induced force of the seal. First, the flow patterns in the labyrinth chamber are studied on the circumferential flow using bubble and on the cross section of the seal chamber using aluminum powder as tracers. And next, the fluid force and its phase angle are obtained from the measured pressure distribution in the chamber and the fluid force coefficients are derived from the fluid force and the phase angle. Those are similar to the expression of oil film coefficients. As a result, it is found that the vortices exist in the labyrinth chambers and its center moves up and down periodically. The pressure drop is biggest in the first stage of chambers and next in the last stage of chambers.

Iwatsubo, T.↗

Bubble Mass Transport Measurement in the Large-Scale Test Loops at Oak Ridge National Laboratory

Molten salts are complex fluids that incorporate multi-phase behavior depending on the chemistry and the physical properties of the entrained components. These components include the carrier salt, the actinide fuel, and fission, activation, and corrosion products, the concentrations of which depends on the burnup history of the salt. Radionuclide transport from the salt into the cover gas / off-gas system depends on volatility as predicted by thermochemistry, but data from the Molten Salt Reactor Experiment (MSRE) conducted in the late 1960s suggest that bubble formation and transport are also important. Anomalously high fractions of noble metals were found in the off-gas system and were attributed to transportation with parent salt aerosols and their association with rising noble gas bubbles. The prediction of such phenomena requires coupled neutronic, thermal hydraulic, and chemical equilibrium calculations, the framework of which is being developed within the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program supported by the US Department of Energy (DOE) Office of Nuclear Energy (NE). However, separate effects tests and models of experiments using tools such as SAM and Thermochimica can guide model developers through important processes. Conversely, model development guides the choice of experiments and systems to provide data that are relevant for validation. This report describes several experiments that tracked gas transport in molten salts, ranging from small-scale systems to large-scale loops. Gas transportation in a molten salt, LiCl-KCl, has been studied using the shadowgraph technique. Sensors such as residual gas analysis, Raman spectroscopy, and laser-induced breakdown spectroscopy have been tested for off-gas measurements. These data were used to interpret how the gases move through the upstream salt / cover gas and the interface between them. Differential pressure measurements were able to detect individual gas bubbles as they popped at the liquid–gas interface. Salt aerosols were collected on a cascade impactor. Their formation was also observed directly via the shadowgraph method, and most of these aerosols were launched ballistically into the cover gas. Fine mists could also be observed. Convection currents through the salt were visualized and can be used to calculate the thermophysical properties of the salt itself. The apparatuses described in this report and in a previous work (McFarlane et al. 2023) have been commissioned and are available for use in making further measurements of salt/surrogate fission product behavior. Novel approaches using neutron imaging are planned for the study of fluoride salts, which cannot be contained in quartz, so shadowgraph visualization is not available. Bubble transport in convective flow and in a slow-moving salt column are planned. The mobile laser-induced breakdown spectroscopy (LIBS) system is available for several applications, including iodine capture in a molten hydroxide scrubber, H2 transport though molten salts to complement Raman analysis, and online tracking of salt aerosol generation, transport, and deposition. This report summarizes the findings from FY24 and the plans for FY25. The work completes milestone M2AT-24OR0702013 of the DOE-NE Advanced Reactor Technology, Molten Salt Reactor Campaign, DOE-NE-5.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synchrotron radiography of Richtmyer–Meshkov instability driven by exploding wire arrays

We present a new technique for the investigation of shock-driven hydrodynamic phenomena in gases, liquids, and solids in arbitrary geometries. The technique consists of a pulsed power-driven resistive wire array explosion in combination with multi-MHz synchrotron radiography. Compared to commonly used techniques, it offers multiple advantages: (1) the shockwave geometry can be shaped to the requirements of the experiment, (2) the pressure (P > 300 MPa) generated by the exploding wires enables the use of liquid and solid hydrodynamic targets with well-characterized initial conditions (ICs), (3) the multi-MHz radiography enables data acquisition to occur within a single experiment, eliminating uncertainties regarding repeatability of the ICs and subsequent dynamics, and (4) the radiographic measurements enable estimation of compression ratios from the x-ray attenuation. In addition, the use of a synchrotron x-ray source allows the hydrodynamic samples to be volumetrically characterized at a high spatial resolution with synchrotron-based microtomography. This experimental technique is demonstrated by performing a planar Richtmyer–Meshkov instability (RMI) experiment on an aerogel–water interface characterized by Atwood number A0∼−0.8 and Mach number M∼1.5. The qualitative and quantitative features of the experiment are discussed, including the energy deposition into the exploding wires, shockwave generation, compression of the interface, startup phase of the instability, and asymptotic growth consistent with Richtmyer's impulsive theory. Additional effects unique to liquids and solids—such as cavitation bubbles caused by rarefaction flows or initial jetting due to small perturbations—are observed. It is also demonstrated that the technique is not shape dependent by driving a cylindrically convergent RMI experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A direct test of Auger cascade induced nucleation from heavy element contamination in C 3 F 8 bubble chambers

Understanding and quantifying the gamma-induced bubble nucleation background in clean nuclear recoil detection bubble chambers is of utmost importance to bubble chamber based dark matter searches. Here, we present data confirming the hypothesis that large Auger cascades from high-Z elements such as iodine and xenon dramatically increase the response of C 3 F 8 bubble chambers to gamma rays. These tests, performed with a small calibration bubble chamber filled with C 3 F 8 +$\mathcal{O}$ (10) ppm xenon, show that the probability of bubble nucleation scales with the rate of xenon inner-shell vacancies, reaching values >10% per K-Shell vacancy for Seitz thresholds of interest to future dark matter searches in bubble chambers. We also place an upper limit on bubble nucleation probability for argon Auger events, relevant to large future bubble chambers which may contain some residual atmospheric argon after the active fluid fill.

47 OTHER INSTRUMENTATION↗

Enhanced Boiling on Micro-Configured Composite Surfaces Under Microgravity Conditions

Two experimental setups: High Heat Flux Pool Boiling Setup and Optical system of Measuring Contact Angle and Spreading Parameters were established and a series of experiments was conducted. The experimental work on the nucleate boiling performance of both Freon-113 and water on the composite surfaces has been finished and the results show that the composite surface with 25% volume fraction of graphite fibers in the copper matrix has the best enhancing performance. Stronger enhancement was obtained for water compared to Freon-113. The wall superheat initiating boiling was reduced 40% and 35% and the heat flux of the nucleate boiling was augmented up to ten times and 6.7 times, respectively. A bubble departure model has been presented to explain the enhancement mechanism of the boiling heat transfer on the composite surfaces. A powerful optical method to measure contact angle and spreading parameters of liquids on solid surfaces, including both transparent and non-transparent substrates, has been developed and successfully used in the measurements for various liquid-solid systems. The experimental work on identification of profiles near three-phase line by laser shadowgraphy method has been finished and the characteristics of the three-phase line for different liquid-solid systems were unveiled, which is very important to understand the mechanism of boiling under microgravity conditions. The four basic patterns of sessile profile were discovered through caustics and caustic-diffraction analysis by applying wave theory in shadowgraphy technology, which contributes to clearly explain the different characteristics of wetting and spreading of various liquids on a solid surface, and therefore to further understand the bubble departure mechanisms. A new working pattern of heat pipes using working fluids with positive surface-tension gradient against temperature was discovered and analyzed, and then the new heat pipe systems using this kind of working fluids have been presented. Two patent devices, i.e. Shadowgraphic Method to Measure Properties of Sessile Drops and Heat Pipe Systems Using New Working Fluids, have been developed; the former has been approved by The United States Patent & Trademark Office and the latter is being examined.

Source record↗

RRM3 Fluid Management Device

The current development progress of the fluid management device (FMD) for the Robotic Resupply Mission 3 (RRM3) cryogen source Dewar is described. RRM3 is an on-orbit cryogenic transfer experiment payload for the International Space Station. The fluid management device is a key component of the source Dewar to ensure the ullage bubble is located away from the outlet during transfer. The FMD also facilitates demonstration of radio frequency mass gauging within the source Dewar. The preliminary design of the RRM3 FMD is a number of concentric cones of Mylar which maximizes the volume of liquid in contact with the FMD in the source Dewar. This paper describes the design of the fluid management device and progress of hardware development

cryogenic fluids↗