Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Analyzing the Adaptive Mesh Refinement (AMR) Characteristics of a High-Order 2D Cubed-Sphere Shallow-Water Model

Adaptive mesh refinement (AMR) is a technique that has been featured only sporadically in atmospheric science literature. This study aims to demonstrate the utility of AMR for simulating atmospheric flows. Several test cases are implemented in a 2D shallow-water model on the sphere using the Chombo-AMR dynamical core. This high-order finite-volume model implements adaptive refinement in both space and time on a cubed-sphere grid using a mapped-multiblock mesh technique. The tests consist of the passive advection of a tracer around moving vortices, a steady-state geostrophic flow, an unsteady solid-body rotation, a gravity wave impinging on a mountain, and the interaction of binary vortices. Both static and dynamic refinements are analyzed to determine the strengths and weaknesses of AMR in both complex flows with small-scale features and large-scale smooth flows. The different test cases required different AMR criteria, such as vorticity or height-gradient based thresholds, in order to achieve the best accuracy for cost. The simulations show that the model can accurately resolve key local features without requiring global high-resolution grids. The adaptive grids are able to track features of interest reliably without inducing noise or visible distortions at the coarse–fine interfaces. Finally and furthermore, the AMR grids keep any degradations of the large-scale smooth flows to a minimum.

54 ENVIRONMENTAL SCIENCES↗

A 1:8.7 Scale Water Tunnel Verification & Validation Test of an Axial Flow Water Turbine

As interest in waterpower technologies has increased over the last few years, there has been a growing need for a public database of measured data for these devices. This would provide a basic understanding of the technology and means to validate analytic and numerical models. Through collaboration between Sandia National Laboratories, Penn State University Applied Research Laboratory, and University of California, Davis, a new marine hydrokinetic turbine rotor was designed, fabricated at 1:8.7-scale, and experimentally tested to provide an open platform and dataset for further study and development. The water tunnel test of this three-bladed, horizontal-axis rotor recorded power production, blade loading, near-wake characterization, cavitation effects, and noise generation. This report documents the small-scale model test in detail and provides a brief discussion of the rotor design and an initial look at the results with comparison against low-order modeling tools. Detailed geometry and experimental measurements are released to Sandia National Laboratories as a data report addendum.

13 HYDRO ENERGY↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent). Because manufacturers’ accuracy estimates for their equipment do not include many of the sources of error found in actual field measurements (and replicated in the laboratory testing in this study) it is essential for a test method that could be used to determine the actual uncertainty in this specific application. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Self-Thickening Chemicals for Improved Conformance Control

The objective of this project is to identify single chemical agents that exhibit a desirable rheological property whereby if such a chemical is dissolved in salt water it increases the solution viscosity significantly with time. We term that behavior as 'self-thickening' and have nicknamed this as 'T85 technology'. As detailed in the original project proposal, such single chemical products can be applied to advantage as agents for selectively slowing or blocking high flow water channels in subsurface oil reservoirs. The net effect is a decrease in water and an increase in oil flow and production. The initial testing has focused on five different synthetic co-polymers that have two or more chemical groups. These chemicals were dissolved at a concentration of 2500 ppm into different salt solutions (sodium chloride, potassium chloride, and calcium chloride) that encompass a range of dissolved salt concentrations. For the sodium chloride and potassium chloride solutions the salt concentration ranged from 1-5 wt%. The calcium chloride dihydrate sample concentrations ranged from 0.1-1 wt%. One set of samples being aged at 25 C and a second set at 50 C. Viscosity measurements versus aging time show two of these agents may exhibit apparent self-thickening behavior under certain salinity and temperature conditions. Generally the effect is greater in lower salinity NaCl brines and at 25 C. Preliminary flow experiments confirm that the aged fluids exhibit increased effective viscosity while flowing through a porous medium (sand pack). These flow tests include the case of the chemical fluid being aged on the bench before injection into a sand pack, and also a second series of sand packs where fresh chemical fluid is injected and allowed to age in-situ. Thus, the results of the static ageing tests together with the flow tests are a technical validation of the T85 concept.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A finite element/Fourier treatment of the Fokker-Planck equation

A method is proposed for a finite element/Fourier solution of the Fokker-Planck (FP) equation describing Coulomb collisions between particles in a fully ionized, spatially homogeneous plasma. A linearized FP equation is obtained by assuming collisions between test particles and a static background are more important than between the test particles themselves. A full 3D velocity space dependence is maintained using cylindrical coordinates (v{sub Double-Vertical-Line },v{sub Up-Tack },{gamma}). When a magnetic field exists, v{sub Double-Vertical-Line} is aligned with it and {gamma} corresponds to gyroangle. Distribution functions are approximated by a Fourier representation in the azimuthal angle, {gamma}, and by a 2D finite element representation in the parallel and perpendicular directions. The FP equation can be solved in a fully implicit manner allowing large, stable timesteps and simulations that arrive quickly at equilibrium solutions. The results of several test problems are discussed including a calculation of the resistivity of a Lorentz plasma, the heating and cooling of a test particle distribution, the slowing down of a beam of test particles and the acquisition of a perpendicular flow for a non-flowing Maxwellian test distribution. Robust convergence upon refinement of the finite element/Fourier representation is highlighted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Durability test of a flowing-water target for isotope harvesting

A high intensity proton irradiation was performed with the flowing-water isotope harvesting target at the University of Wisconsin-Madison Cyclotron Laboratory to measure the rate of degradation of the target shell during irradiation conditions. The beam reached an intensity of 34 µA by the end of the irradiation and covered an area of 0.7 cm 2 on the target. Radiolysis products, such as H 2 O 2 , H 2 , and O 2 , were measured in the bulk water of the system and found to be present at much lower levels than predicted by literature escape yields. Radionuclides formed in the target shell were measured in the system water as a radiotracer for target degradation. Using a simple, beam intensity dependent model, a corrosion rate of 1.5E-6 μm/(μA*s) was found to match the measured radiotracer activities at various points in the irradiation. Furthermore, this rate was used to extrapolate the lifetime of future isotope harvesting targets at the NSCL and FRIB, using the areal power density of different ion beams to scale the corrosion rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scalable and Resilient Etched Metallic Micro- and Nanostructured Surfaces for Enhanced Flow Boiling

Flow boiling and evaporation in tubes and channels occur in a wide variety of energy systems, such as refrigeration, air conditioning, power generation, electronics cooling, distillation, and purification. In this work, we demonstrate remarkably increased heat transfer coefficients of 270% during refrigerant flow boiling in scalable microstructured (~40 µm), industrial-scale (~1 m long) aluminum (Al) tubes, when compared to smooth unstructured Al tubes. To achieve scalable nanomanufacturing, we create highly conformal and durable structured surfaces by relying on hydrochloric acid Al etching. Flow boiling tests were conducted in 6.35 mm diameter Al tubes using R134a refrigerant as the working fluid. To benchmark our approach and to elucidate the effect of the structure length scale, we also fabricated ultrascalable boehmite (AlO(OH)) nanostructured (~300 nm) Al tubes, showing that etched microscale features are necessary and key to enhancement. Durability tests conducted using a 28 day long continual flow boiling experiment demonstrated negligible degradation of the etched surfaces. The scalable and cost-effective techniques used to create these durable, etched-Al microstructures may significantly reduce manufacturing cost when contrasted with current enhancement approaches such as extrusion, drawing, and welding.

36 MATERIALS SCIENCE↗

Design and Preliminary Experimental Results on a Uniform-Field Test Fixture for Power Flow Experiments

Electrodes that produce a uniform electric field across their surfaces are desired for a variety of high-voltage systems including spark-gap switches and transversely excited atmospheric lasers. Here, the implementation of uniform-field electrodes to a parallel-plate load is described for the study of vacuum power flow under pulsed-power applications. We begin with an overview of general uniform-field geometries, and provide an open-source program that generates these geometries as described by Ernst. Following that, a modification to an existing power-flow experimental platform, that adopts a uniform-field geometry, is introduced and its utility is described. Lastly, preliminary experimental results are presented and future steps are outlined.

Capacitors↗

Comparative testing of various flow-cell detectors fabricated using CaF{sub 2} solid scintillator

A monitoring system based on a flow-cell detector was developed for measuring the tritium concentration in water. The flow-cell detector was fabricated using a granular CaF{sub 2} solid scintillator. This system does not use a liquid scintillation counting system and does not generate radioactive organic liquid waste. Moreover, continuous real-time measurements are possible, in contrast to a liquid scintillation counting system, which requires batch measurements. For further development of the system, four flow-cell detectors were fabricated. They included a single 3-mm-diameter cell, three 3-mm-diameter cells in series, a single 5-mm-diameter cell, and three 5-mm-diameter cells in series. Continuously flowing water containing tritium at various concentrations was passed through the flow cells, and tritium count were measured for 600 and 10000 s. Investigating the relation between the count rate and concentration, the three 5-mm-diameter cells were most sensitive, with a linear relation maintained down to approximately 2 Bq/ml and 10 Bq/ml for 10000- and 600-s measurements, respectively. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Additively Manufactured Monolithic SiC and SiC Ceramic Matrix Composites for Concentrating Solar Receiver Applications

Supported by an award from the Solar Technology Office, US Department of Energy, GE Aerospace Research in collaboration with Heliogen Holdings Inc, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR). We report the results of our study of the effective heat transfer characteristic of several candidate structure motifs, or feature geometries, made of SiC via additive manufacturing in a simulative laboratory test. The SiC structure motifs studied include different permutations of three-dimensional periodic lattices and defined shapes. The solar-thermal simulating laboratory test setup is constructed using a 4kW CO2 laser system with beam shaping optics to apply radiative heating power on one face of 2”-diameter cylindrical feature specimens representing the structure motifs of interest for receiver element design. Using the test setup, simulative test conditions representative of a concentrated solar flux of up to ~2000 suns could be achieved in the lab tests under varying air flow through the test structure. A numerical analysis scheme is developed to extract an effective or compound heat transfer coefficient representative of the test structure under steady-state heat flow conditions.

14 SOLAR ENERGY↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗