Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Thermal Image Processing for Feature Extraction from Encapsulated Phase Change Materials

Encapsulated inorganic particles with high melting points (>300 °C) are desired as high-temperature Phase Change Materials (PCMs) for next-generation Latent Heat Thermal Energy Storage (LHTES) systems. One of the many challenges during the development of PCMs is to achieve a high throughput that in turn depends on accurately modeling the relation between process parameters and geometric & thermal properties of the PCMs particle. During the production of the PCMs, a high-speed infrared camera is used to acquire images of the encapsulated material under controlled illumination conditions. This research article focuses on the development of image processing techniques for both geometric and thermal feature extraction during the development of the PCMs. A user-friendly GUI has been designed in MATLAB and preliminary experimental results have demonstrated that the method is fast, accurate and reliable for a high throughput production. The extracted features will be used to develop Machine Learning (ML) models to predict the geometric and thermal properties of the PCM based on the process parameter settings. The ML model will accelerate the search for the optimized process settings to boost the throughput of the production.

25 ENERGY STORAGE↗

An Analytic Formula for Entraining CAPE in Midlatitude Storm Environments

Abstract This article introduces an analytic formula for entraining convective available potential energy (ECAPE) with an entrainment rate that is determined directly from an environmental sounding, rather than prescribed by the formula user. Entrainment is connected to the background environment using an eddy diffusivity approximation for lateral mixing, updraft geometry assumptions, and mass continuity. These approximations result in a direct correspondence between the storm-relative flow and the updraft radius and an inverse scaling between the updraft radius squared and entrainment rate. The aforementioned concepts, combined with the assumption of adiabatic conservation of moist static energy, yield an explicit analytic equation for ECAPE that depends entirely on state variables in an atmospheric profile and a few constant parameters with values that are established in past literature. Using a simplified Bernoulli-like equation, the ECAPE formula is modified to account for updraft enhancement via kinetic energy extracted from the cloud’s background environment. CAPE and ECAPE can be viewed as predictors of the maximum vertical velocity w max in an updraft. Hence, these formulas are evaluated using w max from past numerical modeling studies. Both of the new formulas improve predictions of w max substantially over commonly used diagnostic parameters, including undiluted CAPE and ECAPE with a constant prescribed entrainment rate. The formula that incorporates environmental kinetic energy contribution to the updraft correctly predicts instances of exceedance of by w max , and provides a conceptual explanation for why such exceedance is rare among past simulations. These formulas are potentially useful in nowcasting and forecasting thunderstorms and as thunderstorm proxies in climate change studies. Significance Statement Substantial mixing occurs between the upward-moving air currents in thunderstorms (updrafts) and the surrounding comparatively dry environmental air, through a process called entrainment. Entrainment controls thunderstorm intensity via its diluting effect on the buoyancy of air within updrafts. A challenge to representing entrainment in forecasting and predictions of the intensity of updrafts in future climates is to determine how much entrainment will occur in a given thunderstorm environment without a computationally expensive high-resolution simulation. To address this gap, this article derives a new formula that computes entrainment from the properties of a single environmental profile. This formula is shown to predict updraft vertical velocity more accurately than past diagnostics, and can be used in forecasting and climate prediction to improve predictions of thunderstorm behavior and impacts.

54 ENVIRONMENTAL SCIENCES↗

Using Convex Optimization to Efficiently Apportion Tracer and Pollutant Sources From Point Concentration Observations

Abstract Rivers transport elements, minerals, chemicals, and pollutants produced in their upstream basins. A sample from a river is a mixture of all of its upstream sources, making it challenging to pinpoint the contribution from each individual source. Here, we show how a nested sample design and convex optimization can be used to efficiently unmix downstream samples of a well‐mixed, conservative tracer in a steady state system into the contributions of their upstream sources. Our approach is significantly faster than previous methods. We represent the river's sub‐catchments, defined by sampling sites, using a directed acyclic graph. This graph is used to build a convex optimization problem which, thanks to its convexity, can be quickly solved to global optimality—in under a second on desktop hardware for data sets of ∼100 samples or fewer. Uncertainties in the upstream predictions can be generated using Monte Carlo resampling. We provide an open‐source implementation of this approach in Python. The inputs required are straightforward: a table containing sample locations and observed tracer concentrations, along with a D8 flow‐direction raster map. As a case study, we use this method to map the elemental geochemistry of sediment sources for rivers draining the Cairngorms mountains, UK. This method could be extended to non‐conservative and non‐steady state tracers. We also show, theoretically, how multiple tracers could be simultaneously inverted to recover upstream run‐off or erosion rates as well as source concentrations. Overall, this approach can provide valuable insights to researchers in various fields, including water quality, geochemical exploration, geochemistry, hydrology, and wastewater epidemiology.

Barnes, Richard↗

Non-equilibrium low-temperature plasma-assisted combustion of iso-octane: Perturbing pyrolysis and oxidation kinetics

Here, in this study, a plasma-coupled flow reactor facility is used to examine the effects of non-equilibrium low-temperature plasmas on perturbing the pyrolysis and oxidation kinetics of iso-octane. Experiments were performed in highly dilute reactive mixtures of nitrogen, at near isothermal conditions for temperatures ranging from 523 K to 1203 K. Experiments cumulatively demonstrated enhanced chemical reactivity with the plasma for temperatures below 900 K, and a lowering of the hot-ignition temperature. Detailed kinetic insight was derived from a 0D plasma-coupled kinetic model, utilizing a constructed mechanism that combined both plasma-specific chemistry and the neutral combustion chemistry. For pyrolysis conditions, the model displayed relatively good agreement with fuel consumption and the formation of most intermediates compared to the experimental data, demonstrating the model is able to accurately predict primary radical formation from the plasma directly interacting with the fuel. Enhanced reactivity was attributed to collisional quenching of excited-states of N 2 with fuel, which led to efficient fuel fragmentation and enhancement of the H-radical flux. For oxidation conditions, the model displayed satisfactory agreement with the experiments. Model predictions were able to accurately predict fuel consumption and most intermediate speciation data for T > 800 K, but most discrepancies were towards T < 800 K in particular with oxygenated intermediates. In the presence of oxygen, plasma effects were predominantly spent on efficient enhancement of O- and H-radical fluxes, leading to further fuel fragmentation and initiation of both the OH- and HO 2 -radical pools. Subsequent reactivity of iso-octane was then dictated by the response of the temperature-dependent neutral chemistry. At low-temperatures (T = 643 K), enhanced fuel radicals and O 2 -additon chemistry lead to the formation of oxygenated species, while at intermediate temperatures (T = 843 K) net decrease in OH-radical reactivity led to an increase in hydrocarbon speciation. Near the self-ignition threshold (T = 1163 K), radicals generated by high-temperature branching reactions dominate the oxidation process and effectively ignition. This study ultimately demonstrated that the enhancement of radicals afforded by the plasma causes a deviation in known understanding of iso-octane kinetics in some regards and warrants future studies to reconcile these discrepancies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2019 NETL Related Energy Diagrams

This document illustrates the energy production, consumption, use, flow, and CO 2 emission in the U.S. in 2019.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD Simulation of Biomass Pyrolysis Vapor Upgrading over a Pt/TiO 2 Catalyst in Fixed and Moving Beds

This report presents a comprehensive computational fluid dynamics (CFD) study of the biomass pyrolysis vapor phase upgrading and the catalyst regeneration in different reactors under various operational conditions. This study used the open-source software Multiphase Flow with Interphase eXchanges (MFiX), developed at National Energy Technology Laboratory (NETL) for simulating hydrodynamics, heat transfer, and chemical reactions in multiphase systems. This simulation solved the conservation of mass, momentum, energy, species for gas and solid phases with chemical reactions.

09 BIOMASS FUELS↗

Bipolar Membranes with an Electrospun 3D Junction

Freestanding bipolar membranes (BPMs) with an entirely new and transformative morphology were fabricated and characterized. The key disruptive design element was a water-splitting/water-generation junction layer of finite thickness composed of interwoven and interlocking electrospun anion-exchange polymer (AEP) fibers and cation-exchange polymer (CEP) fibers. Methods were developed to sandwich the 3D junction layer between two pre-formed dense AEP and CEP films., with the closure of all interfiber voids, where the processing steps are easily incorporated into a commercial roll-to-roll membrane manufacturing scheme. A series of membranes were made using different polymers and junction layers to identify the optimum morphology and composition for water-splitting and water-generation applications. For water splitting, the 3D junction BPMs worked remarkably well with operating current densities at/above 1.0 A/cm2 (10X greater than commercial BPMs) at a transmembrane voltage drop of only 1.1 V. In water generation mode, the 3D junction BPMs operated at 0.5 A/cm2, a world-record current density. The membranes were found to exhibit outstanding durability and can be manufactured at scale for low cost. The high operating current densities and stable long-term operation are due to the 3D junction layer design, where there is a high interfacial area for water splitting or water generation reactions and where the interlocking fibers prevent delamination of the outer films. These new BPMs are ideal candidate materials for both existing water-splitting electrodialysis separations and new electrochemical processes, such as large-scale direct air capture of CO 2 , reactors for CO 2 reduction, self-hydrating fuel cells, and redox flow batteries.

30 DIRECT ENERGY CONVERSION↗

Lagrangian and Dirac constraints for the ideal incompressible fluid and magnetohydrodynamics

The incompressibility constraint for fluid flow was imposed by Lagrange in the so-called Lagrangian variable description using his method of multipliers in the Lagrangian (variational) formulation. An alternative is the imposition of incompressibility in the Eulerian variable description by a generalization of Dirac’s constraint method using noncanonical Poisson brackets. Here it is shown how to impose the incompressibility constraint using Dirac’s method in terms of both the canonical Poisson brackets in the Lagrangian variable description and the noncanonical Poisson brackets in the Eulerian description, allowing for the advection of density. Both cases give the dynamics of infinite-dimensional geodesic flow on the group of volume preserving diffeomorphisms and explicit expressions for this dynamics in terms of the constraints and original variables is given. Since Lagrangian and Eulerian conservation laws are not identical, comparison of the various methods is made.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isotherm Modeling and Techno-Economic Analysis of Contactor Technologies for New Tetraamine-Appended MOF for NGCC Applications

Recently, a family of tetraamine-functionalized metal-organic frameworks (MOF) has been reported as promising sorbent materials for capturing CO2 from flue gas conditions relevant to natural gas combined cycle (NGCC) applications. The main advantages of these materials are their two-step cooperative CO2 adsorption, which gives rise to unusual two step-shaped CO2 adsorption profiles and their high thermal stability. This work presents the modelling of the two-transition isotherm of the tetraamine-appended MOF, N,N'-bis(3-aminopropyl)-1,4-diaminobutane (3-4-3)-appended Mg2(dobpdc), and the techno-economic analysis (TEA) of carbon capture processes utilizing this sorbent. Due to the unusual isotherm shapes of the experimental CO2 adsorption data for tetraamine-appended Mg2(dobpdc) and the strong nonlinearity of CO2 loading with respect to temperature and pressure, we tested two different models which use logistic functions for representing the different isotherm behaviors in the different pressure ranges. The first model uses the quadratic isotherm model in the low-pressure region, the Langmuir isotherm model in the middle pressure range, and the dual site Langmuir isotherm model in the high-pressure range. To model the transition between regions we used the arctangent functions independent of temperature and the thermal effect was accounted by using the Clausius-Clapeyron relation]. The second model is an extension of the weighted dual-site Langmuir isotherm model presented by Hughes et al.. In this extended model, the dual-site Langmuir isotherm is employed in the three transition regions, using temperature-dependent logistic functions to activate or deactivate the isotherm model in the low, middle, and high-pressure ranges. Both models fit the experimental data quite well with root mean squared errors (RMSE’s) of 0.41 and 0.17 for model 1 and model 2, respectively. Since model 2 resulted in a lower RMSE, it was leveraged for the development of the gas/solid contactor models used by the TEA. Specifically, two different contactor models, an axial-flow fixed bed and moving bed contactor, were developed as part of this work. These models are dynamic, pressure-driven, and consist of mass, energy, and momentum conservation equations. A kinetic model was also developed by performing parameter estimation using experimental fixed bed breakthrough data. These models are then used to simulate CO2 capture processes from the flue gas generated from a ~600 gross MW NGCC power plant. A cost model was developed which considers the capital cost of the reactors and the significant operating costs such as steam and electricity. Using NETL’s Framework for the Optimization and Quantification of Uncertainty of Uncertainty and Surrogates tool (FOQUS), which has the capability of linking models built using numerous modelling platforms with derivative-free optimization solvers, a techno-economic optimization of the carbon capture processes was performed which minimizes the cost of capture.

Caballero, Daison↗

Transfer and Flushing Evaluation for Potential Precipitated Solids in the 241-AP-106 to EMF Transfer Pipeline for DFLAW

Waste transfer pipeline flushing is necessary to maintain pipeline performance, but added flush fluid increases the nuclear waste inventory. During the Direct Feed Low-Activity Waste (DFLAW) mission, waste transfer lines from the Interim Low-Activity Waste Storage Tank (i.e., 241-AP-106) to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility must have the capability of being flushed to prevent accumulation of solids and to mitigate corrosion concerns. Operational experience at Hanford has shown that the solids precipitation occurs during processing operations from dilute Hanford liquids. Pacific Northwest National Laboratory was requested to evaluate the potential precipitated solid particle transport and flushing operational capabilities of the AP-106 through the Effluent Management Facility (EMF) low-point drain LAW feed pipeline. The evaluation results do not provide operational requirements, but rather provide a scoping basis for understanding the potential operational significance of solids precipitation in the pipeline. The salt and aluminum phase solids most likely to precipitate from the LAW feeds during cooling, evaporation, or mixing have particle densities that are estimated to range from 1.62 to 2.78 g/mL and a spherical particle size range of 8 to 2100 μm, depending on the solid phase considered. Application of the method to calculate the critical deposition velocity required by TFC-ENG-STD-26 at conservatively bounding estimates for the solids concentrations demonstrates that potentially precipitated solids may deposit on the bottom of the transfer pipe invert at the lower LAW feed pipeline flow rate, but the upper LAW feed pipeline flow rate will likely prevent deposition. The system pressure limit for the AP-106 through the EMF low-point drain LAW feed pipeline likely exceeds any pressure loss at a calculated critical deposition velocity even for the most adverse potential precipitated solid. However, should solids settle as a result of no-flow conditions, the flow capabilities of the AP-106 through the EMF low-point drain LAW feed pipeline are shown, based on the available literature, to be potentially inadequate for effective flushing operations to remove solids, even at solids concentrations below the maximum specified for LAW feed. Thus, stepwise solids accumulations over multiple transfers may be an issue, and eventual line plugging may occur. Further inadequacies may potentially be realized should the cohesive nature of certain precipitates be accounted for.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental investigation of power transient flow boiling

To advance the mechanistic understanding of power transients in flow boiling, experimental investigations are performed to capture the thermal response of four different kinds of cladding materials, including FeCrAls, to Fuchs reactivity initiated accident transients and linear ramp power transients. The transition boiling regime is phenomenologically reflected in power-transient flow boiling, which is different from steady-state boiling. In light of this, the critical heat flux that is usually featured with temperature overshooting does not indicate thermal safety margin of cladding materials as conservatively as the maximum heat flux, which is greater than critical heat flux in the power transient boiling curve. This is physically attributed to the thermal energy deposition on the cladding wall. In addition, the thermal energy released from the cladding wall results in different boiling heat transfer coefficient for the decreasing and increasing power stages respectively during the Fuchs power transient. The maximum heat flux difference gap, which appears due to changes in cladding materials and transient time scales, is appreciable under an intermediate heat convection regime. However, this difference gap is gradually weakened by the progressive increasing of mass flux and/or inlet subcooling due to the enhanced dominance of heat convection over heat conduction. Finally, the small difference gap of maximum heat flux is found to be insignificant under the weak heat convection because of power transient induced annular flow instability.

42 ENGINEERING↗

Mass transport limitations in polymer electrolyte water electrolyzers using spatially-resolved current measurement

Here this work utilizes spatially-resolved current measurements to provide insight into mass transport limitations in electrolyzers that are not observable from traditional polarization measurement. In this study, two types of flow-fields (parallel and triple-serpentine) and two types of diffusion media (patterned porous thin titanium foil LGDLs and Ir-coated titanium felt PTLs) were examined. A non-uniform current distribution dominated by mass transport limitations was observed to be instigated by the restriction of liquid water transport to catalyst sites. Additionally, conditions are revealed which yield similar polarization performance but dissimilar current distributions. In such cases, the transport limitations for different architectures and porous media affect polarization in different regions of the active area. Furthermore, the triple-serpentine flow-field used in this study performs better than the parallel flow-field under mass transport limited operating conditions. This indicates that the parallel flow-field used in this study is more susceptible to starvation than the triple-serpentine flow-field for the electrolyzer studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Separating Sensible and Latent Cooling with Electrically Charged Rotating Vortexes and Vapor Capturing Air Handler Technology

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air below its dew point temperature. This project investigated air dehumidification achieved by electrostatic and dielectrophoresis forces in electrosprays and centrifugal principles in cyclone separators. As a practical implementation of these processes, Electrospray Vortical Flow eXchanger (EVFX) prototypes were designed, fabricated, and tested. Electrosprays were employed to energize water droplets, which then captured water vapor via dielectrophoresis. A cyclone separator was positioned downstream of the electrosprays. This combination increased the dehumidification efficiency and controlled the flow of the water vapor condensate removed from the air.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine Learning Assisted Safety Modeling and Analysis of Advanced Reactors

With the advances in computational power and numerical methods, analysts can now rely on first-principle simulations to predict ultra-fine details in a variety of applications. Advances in machine learning (ML) have produced algorithms that can now learn high-level abstractions via hierarchical models. This project aims to leverage advances in ML techniques and the available high-resolution simulation data to develop a novel modeling and simulation (M\&S) methodology for reactor safety analysis. While application-agnostic ML techniques are available, complex physics constraints need to be incorporated into ML techniques to build ML-based closures for computationally efficient predictive simulations. This project intends to develop a physics-guided data-driven multi-scale methodology for M\&S of advanced reactors. The project focuses on thermal fluid (T/F) phenomena, which play major roles in advanced reactor safety. Specifically, we propose a data-driven coarse-mesh turbulence model based on local flow features for the transient analysis of thermal mixing and stratification in a sodium-cooled fast reactor (SFR). The model has a coarse-mesh setup to ensure computational efficiency, while it is trained by fine-mesh computational fluid dynamics (CFD) data with Reynolds-averaged Navier-Stokes (RANS) turbulence model to ensure accuracy. Three different neural networks are developed and tested for loss-of-flow transients in the hot pool of SFR, i.e. the densely connected convolutional neural network (DCNN), long-short-term-memory network based on proper orthogonal decomposition (POD-LSTM), and the DCNN informed by LSTM (DCNN-LSTM). The performances of these three neural networks are evaluated based on baseline models. The DCNN-LSTM model has been chosen for further hyperparameter optimization. Furthermore, based on a simplified two-dimensional case, uncertainty quantification (UQ) of the developed ML-based closure are investigated with three methods, i.e. Monte Carlo dropout, deep ensemble, and Bayesian neural network. The developed ML-based turbulent viscosity closure relation based on deep ensemble is then integrated into the system analysis module SAM and serves as a term in the conservation equations. Such a SAM-ML based procedure guarantees that the obtained results are consistent with the physical constraints of the thermal-fluid system. The SAM-ML simulation on the same loss-of-flow transient showed comparable accuracy with the CFD simulation but with a much coarser mesh setup. Last but not least, the ML-based closure improvement with the support of higher-fidelity data from large eddy simulation (LES) is discussed. As a first step towards this direction, a baseline LES simulation is performed to obtain comparable data with RANS results. Based on the early results, future investigation on further improving the ML-based closure is discussed. We believe the developed approach that combines scientific machine learning with nuclear system analysis code can benefit the advanced reactor community as more accurate safety analyses will better characterize reactor safety margins and reduce licensing efforts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Review of heat transfer enhancement techniques in two-phase flows for highly efficient and sustainable cooling

We show that two-phase internal flow is ubiquitous to many systems due to its ability to transfer large amounts of heat effectively. Recent advances motivated by sustainability have pushed towards augmenting the heat transfer between the tube and the two-phase working fluid. Augmenting heat transfer in two-phase flows enables process intensification, and compactness leading to reduced cost and material consumption. This review investigates the effect of heat transfer enhancement techniques on different fluids including R134a, R407C, R22, etc … The techniques are categorized into passive and active and focus on durable enhancement methods which do not include surface structuring or coating. Passive techniques utilize geometrical and surface modifications to induce better mixing. Several passive techniques are analyzed including fins, inserts, and more. In analyzing these techniques, the effect of changing geometric parameters is studied, and the limitations are highlighted. Further, active techniques that enable heat transfer enhancement through applying power are also investigated. Electrohydrodynamic approaches are analyzed and compared to passive techniques. Additionally, the implications of heat exchange enhancement in the context of global energy are discussed. An energy analysis discretized by the use sector is conducted, with an emphasis on predicting the future potential for renewable and sustainable development. Moreover, although active approaches provide the highest heat transfer enhancement, due to implementation difficulties, passive techniques are more frequently adopted. The review ends with discussion of next-generation heat exchangers which will rely more on additive manufacturing due to its flexibility and reduced cost per part as the technology matures.

Nusselt number↗

A Three-Dimensional, Analytical Wind Turbine Wake Model: Flow Acceleration, Empirical Correlations, and Continuity

A new, three-dimensional, analytical, steady-state wake model is presented that includes local flow acceleration near the rotor, improving the wake description compared to existing models. Wake structures such as the momentum deficit and regions of accelerated flow are concisely described with compound and normal Gaussian functions. Large-eddy simulations (LES) are used as training data to develop the model using two in-line turbines under various inflow conditions parameterized by hub-height wind speed and turbulence intensity. Mass conservation is considered by fixing two components of the wake velocity model and optimizing the third to best satisfy continuity; after which, the model performs comparably if not better than existing work with regards to both relative error and mass consistency. The final model demonstrates a high degree of flexibility, making use of empirical correlations to scale across different inflow conditions. The inclusion of these effects is capable of revealing unused opportunities for enhanced power generation by aligning wake trajectories with these regions of accelerated flow.

modeling↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced District Energy Controls for Improved Efficiency and Resilience

District energy (DE) systems have efficiently provided heat and cooling to buildings in the US for over a century by leveraging economies of scale through shared generation assets. However, optimizing DE boiler and chiller plants is complex due to the intricate mix of equipment and multiple operating flows. Sophisticated controls are necessary to achieve highest efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗