Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Causal mechanism of injection-induced earthquakes through the M w 5.5 Pohang earthquake case study

Causal mechanisms for fluid injection-induced earthquakes remain a challenge to identify. Past studies largely established spatiotemporal correlations. Here, we propose a multi-process causal mechanism for injection-induced earthquakes through a case study of the 2017 M w 5.5 induced earthquake near Pohang Enhanced Geothermal System, Korea, where detailed hydraulic stimulation and on-site seismicity monitoring data provide an unprecedented opportunity. Pore pressure modeling reveals that pore pressure changes initiate seismicity on critically stressed faults and Coulomb static stress transfer modeling reveals that earthquake interactions promote continued seismicity, leading to larger events. On the basis of these results, we propose the following causal mechanism for induced seismicity: pore pressure increase and earthquake interactions lead to fault weakening and ultimately triggering larger earthquakes later in the process. We suggest that it is prudent that pore pressure change, initial seismicity locations, and Coulomb static stress transfer from seismicity earlier in the sequence are assessed in real-time.

58 GEOSCIENCES↗

Metamorphism-facilitated faulting in deforming orthopyroxene: Implications for global intermediate-depth seismicity

Significance The exothermic metamorphic reaction in orthopyroxene (Opx), a major component of oceanic lithospheric mantle, is shown to trigger brittle failure in laboratory deformation experiments under conditions where garnet exsolution takes place. The reaction product is an extremely fine-grained material, forming narrow reaction zones that are mechanically weak, thereby facilitating macroscopic faulting. Oceanic subduction zones are characterized by two separate bands of seismicity, known as the double seismic zone. The upper band of seismicity, located in the oceanic crust, is well explained by dehydration-induced mechanical instability. Our newly discovered metamorphism-induced mechanical instability provides an alternative physical mechanism for earthquakes in the lower band of seismicity (located in the oceanic lithospheric mantle), with no requirement of hydration/dehydration processes.

58 GEOSCIENCES↗

Ultra High-Temperature Magnetic Bearing System for s-CO 2 Turbines/Expanders. Phase II Final Report

The goal of this project is to design and construct of a prototype of ultra-high temperature permanent magnet (UHT–PM), which provides the force to pull the spinning shaft towards the target position in the magnetic bearing (MB) clearance circle. This project will develop a PM biased MB system, that is actively cooled to the 550°C maximum operating temperature limit of PMs. The MB test environment will include 700°C, 40krpm and 4,000 psi requirements to advance the supercritical carbon dioxide (sCO 2 ) and other types of Brayton power cycle systems. The proposed novel MBs combine PMs for supplying the bias field and electromagnets for supplying the control field, both in UHT conditions. The choice of material is the UHT Sm-Co PMs (US patent 6,451,132) due to their significantly better thermal stability. The 6-pole homopolar design permits uninterrupted force delivery via a redundant control capability (US patent 7,429,811) even if 3 poles were to fail. The Phase I efforts was to focus on development and demonstration of component technologies and detailed design of full scale components and a demonstrator test rig for use in Phase II. UHT–PMs were produced and used in the MB actuator. The operating environment of the EEC-T550 Sm-Co magnet material could be extended by implementing active cooling. Electromagnetic coils imbedded in the MB provide forces to stabilize the shaft position at the target via sensing and control stages. Shaft position sensors enable to identify the present position of the spinning shaft relative to its desired target position in the MB clearance circle (air gap). Auxiliary bearings will be installed to provide a backup support system in the event that power to the MB fails or there is a fault in a device providing current to the MB coils. For control, reliability and safety reasons the sensors and auxiliary bearings are typically located as close as possible to the MBs, which exposes them to the same environmental conditions. Development of only the actuator for the UHT environment is an inadequate approach to complete integration of the MB system in the turbine/expander. Therefore the UHT sensor and auxiliary bearing were designed and developed along with the actively cooled, UHT-PM actuator development. Although shaft position sensors are commercially available (Kaman) they may cost up to $10k per channel, and a full 5 axis magnetic suspension is best implemented with up to 20 sensors. Once successfully completed, this project will significantly extend the operating environment capability for turbomachinery applications such as nuclear power, concentrated solar thermal, fossil fuel, geothermal, and shipboard propulsion. The further advancement of UHT-PM-MB will also strengthen the US position in PM technology, which is presently heavily dominated by China. The UHT Sm-Co magnet material that will be utilized in the proposed work has been developed exclusively by the project proposer. Many actuators, motors, generators and other MB applications will greatly benefit from the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Siting of EV Fleet Charging Station Considering EV Mobility and Microgrid Formation for Enhanced Grid Resilience

Coordinating infrastructure planning for transportation and the power grid is essential for enhanced reliability and resilience during operation and disaster management. This paper presents a two-stage stochastic model to optimize the location of electric vehicle fleet charging stations (FEVCSs) to enhance the resilience of a distribution network. The first stage of this model deals with the decision to place an FEVCS at the most favorable and optimized location, whereas the second stage aims to minimize the weighted sum of the value of lost load in multiple potential scenarios with different faults. Indeed, the second stage is a joint grid restoration scheme with network reconfiguration and microgrid formation using available distributed generators and fleet electric vehicles. The proposed model is tested on a modified IEEE-33 node distribution network and a four-node transportation network. Case studies demonstrate the effectiveness of the proposed model.

25 ENERGY STORAGE↗

Data requirements for improving the Quantitative Risk Assessment of liquid hydrogen storage systems

Quantitative Risk Assessment (QRA) supports the development of risk-informed safety codes and standards which are employed to enable the safe deployment of hydrogen technologies essential to decarbonize the transportation sector. System reliability data is a necessary input for rigorous QRA. Here, the lack of reliability data for bulk liquid hydrogen (LH 2 ) storage systems located on site at fueling stations limits the use of QRAs. In turn, this hinders the ability to develop the necessary safety codes and standards that enable worldwide deployment of these stations. Through a QRA-based analysis of a LH 2 storage system, this work focuses on identifying relevant scenario and probability data currently available and ascertaining future data collection requirements regarding risks specific to liquid hydrogen releases. The work developed consists of the analysis of a general bulk LH 2 storage system design located at a hydrogen fueling station. Failure Mode and Effect Analysis (FMEA) and traditional QRA modeling tools such as Event Sequence Diagrams (ESD) and Fault Tree Analysis (FTA) are employed to identify, rank, and model risk scenarios related to the release of LH 2 . Based on this analysis, scenario and reliability data needs to add LH 2 -related components to QRA are identified with the purpose of improving the future safety and risk assessment of these systems.

08 HYDROGEN↗

Mitigating Injection‐Induced Seismicity Along Basement Faults by Extraction: Application to 2016–2018 Pohang Earthquakes

Abstract The risk of induced earthquake is considered as the major obstacle for sustainable subsurface energy activities. As a mitigation approach, mechanistic risk assessment can be essential to minimize the potential of seismic hazard. Coupled hydro‐mechanical modeling approach is integrated with geomechanical analysis to better assess the occurrence of seismicity induced by injection and/or extraction, which will provide a basis to update operational conditions (e.g., number and location of mitigating wells, rate and duration of operations) for mitigating earthquake nucleation. The Coulomb stability analysis and seismicity rate estimates from this generic study indicate that simultaneous extraction can relieve injection‐induced pore‐pressure buildup, but also transfer and accumulate elastic energy along the faults. Field‐scale simulation with variation in well design for the Pohang EGS site, South Korea, show that multiple wells aligned across a preexisting fault form gradients of pressure and stress fields normal to the fault, which can enhance the direct impact of diffusion process and poroelastic stressing on the fault stability perturbation. Our mechanistic study suggests multiphysics‐oriented mitigation strategies that consider (1) possible mechanical deformation, caused by hydro‐mechanical coupling effects, and (2) proper configuration of well operations based on site‐specific geological characteristics.

Chang, K. W.↗

Characterization with dense array data of seismic sources in the shallow part of the San Jacinto fault zone

SUMMARY We analyse dominant sources identified in a catalogue of more than 156 000 localizations performed using a 26-d data set recorded by a dense array set on the San Jacinto fault near Anza, in California. Events were localized using an array processing technique called Match Field Processing. As for all array processing techniques, the quality of the event position decrease when the events are outside of the array. We thus separate localizations in and outside the array using simple geometrical conditions. We compare the time distribution of the localization to additional data such as meteorological data, day of human activity as well as existing catalogues to determine the nature of the dominant events located using our method. We find that most of the events located outside of the array could be attributed to a surface structure excited by wind. On the other hand, part of the localizations under the array occur during regional earthquakes and could correspond to diffraction on the fault's heterogeneities. The rest of the localizations inside the array could be generated by the fault itself.

Geochemistry & Geophysics↗

Optimizing Facility Operations by Applying Machine Learning to the Army Reserve Enterprise Building Control System (Final Report)

Thousands of U.S. Department of Defense (DoD) buildings have building automation systems (BASs) and/or advanced meters. Although these systems have a wealth of data, performance optimization requires time and expertise to review and act on that information. Machine learning (ML) can provide automated and actionable insights to controls operators. This demonstration implemented proven ML methods on the Army Reserve Enterprise Building Control System. ML refers to algorithms that “learn” from data and improve their performance on a given task over time. In the buildings domain these tasks range from predicting future energy consumption, to identifying operational issues before faults occur, to optimizing control decisions. To learn, ML requires input data, which – for buildings – typically consists of instrument data such as energy consumption data and subsystem controls information such as set-point temperatures, and context data consisting of information such as the physical location of the building, the area of the building, and the weather. ML models use the relationships learned from the input data to make predictions with new, previously unseen, data. The team was able to investigate and successfully implement the following ML use cases: labeling consumption data as anomalous or non-anomalous; baseline whole-building load prediction (unknown fault status); fault detection (validation not possible); and site prioritization for energy-related projects. Due to the constraints of the project, interventions were not able to be implemented during the demonstration; therefore, assessments of operational cost savings and maintenance avoided could not be performed. The project has been presented at two leading national building conferences and two additional publications to peer-reviewed journals are currently in preparation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rock Valley Direct Comparison Relocation Working Group Location Results and Recommendations (Version 4.0)

The Source Physics Experiments (SPE) were designed to improve our physics-based understanding of explosion sources for the purposes of nuclear test monitoring. Phase I consisted of 6 chemical explosions in the Climax Stock Granite of the Nevada National Security Site (NNSS), while Phase II consisted of 4 explosions in a contrasting dry alluvium geology (DAG) in Yucca Flat, providing essential data in various media and emplacement conditions to further modeling efforts. For Phase III, the Rock Valley Direct Comparison (RVDC) seeks to directly compare earthquake and explosion source types. An unusually shallow series of events in 1993 along the Rock Valley Fault Zone in the southeastern portion of the NNSS has been targeted for this direct comparison. Depth ranges for the events, previously estimated to be less than 3 km, is achievable by modern drilling techniques and accessibility to the epicentral locations would require minimal improvements to the infrastructure. The events providing this unique opportunity for direct comparison are the focus of this report.

58 GEOSCIENCES↗

Joint Focal Mechanism Inversion Using Downhole and Surface Monitoring at the Decatur, Illinois, CO2 Injection Site

ABSTRACT The three-year CO2 injection period at the Illinois Basin - Decatur Project site (Decatur, Illinois, United States) produced a number of microseismic events distributed in very distinct spatiotemporal clusters with different orientations. Further characterization of the microseismicity encompasses the determination of the event source mechanisms. Initially, the microseismic monitoring network consisted solely of borehole sensors, but has been extended with surface sensors, thereby significantly improving the data coverage over the focal sphere. This article focuses on 23 events from the northernmost microseismic cluster (about 2 km from the injection point) and takes advantage of both, surface and downhole, recordings. The resulting strike-slip east–west-oriented focal planes are all consistent with the east–west orientation of the cluster in map view. The injection-related increase of pore pressure is far below the formation fracture pressure; however, small stress-field changes associated with the pore-pressure increase may reach as far as to the investigated cluster location. Monte Carlo modeling of the slip reactivation potential within this cluster showed that the observed maximum stress-field orientation of N068° is the optimum orientation for fault reactivation of the east–west-oriented cluster. Our results suggest that the east–west orientation of the investigated cluster is the main reason for its activation, even though the cluster is about 2 km away from the low-pressure injection point.

Geochemistry & Geophysics↗

ERSAP: Toward Better NP Data-Stream Analytics With Flow-Based Programming

This paper presents an reactive, actor-model and FBP paradigm based framework that we develop to design data-stream processing applications for HEP and NP. This framework encourages a functional decomposition of the overall data processing application into small mono-functional artifacts. Artifacts that are easy to understand, develop, deploy and debug. The fact that these artifacts (actors) are programmatically independent they can be scaled and optimized independently, which is impossible to do for components of the monolithic application. One of the important advantages of this approach is fault tolerance where independent actors can come and go on the data-stream without forcing the entire application to crash. Furthermore, it also makes it is easy to locate the faulty actor in the data pipeline. Due the fact that the actors are loosely coupled, and that the data (inevitably) carries the context, they can run on heterogeneous environments, utilizing different accelerators. This paper describes the main design concepts of the framework and presents a ?proof of concept? application design and deployment results obtain processing on-beam calorimeter streaming data.

Gyurjyan, V.↗

Data Driven Fault Detection of Premixer Centerbody Degradation in a Swirl Combustor

This paper introduces a data-driven framework for combustor-focused, performance-based condition monitoring of gas turbines. Commercial condition monitoring systems typically generate huge amounts of data that make efficient onboard monitoring challenging. This paper focuses on quantifying combustor component degradation, using premixer centerbody degradation in a swirl stabilized combustor as a case study. The input for these analyses is acoustic pressure measurements acquired at various locations on the combustor. The diagnosis methodology is based on a classification framework and consists of 3 steps: 1) Data curation, 2) Feature Engineering, and 3) Diagnosis. Data curation ensures good quality of the data that is passed through the algorithm. Feature engineering deals with the extraction of the most informative features, from the most informative sensors, that can accurately capture the introduced fault. To perform diagnosis, the classification model is trained using experimentally acquired data and is then tested on a separate data set. The framework was able to achieve high classification accuracy (>99%) for training size as low as 30% of the total recorded observations. The low number of features required to achieve this accuracy suggests high potential for integration into existing onboard condition monitoring systems.

data driven methods, fault detection, swirl flames↗

A Play-Based Exploration of CO 2 Storage in the Illinois Basin (Final Technical Report)

This report documents the results of "A Play-Based Exploration of CO₂ Storage in the Illinois Basin" (DE-FE0032366), a project funded by the U.S. Department of Energy Office of Fossil Energy and Carbon Management and conducted by the Illinois State Geological Survey (ISGS) at the University of Illinois Urbana-Champaign in partnership with Visage Energy. The project adapted play-based exploration (PBE), a systematic basin-scale evaluation methodology from the petroleum industry, to screen areas of Illinois for commercial geologic carbon storage (GCS) in Cambro-Ordovician strata. The traditional play concept was expanded to encompass three play element groups, subsurface geologic factors, surface features, and societal factors, yielding 24 play elements with defensible suitability criteria applied through a five-tier classification scheme. An integrated geospatial database was assembled from ISGS, MGSC, MRCI, NATCARB, and public data sources, supported by significant data-improvement work including correction of legacy well locations, digitization of more than 1,300 well construction records using the DOE CATALOG team's OGRRE tool, compilation of a statewide 2D seismic database, and production of a refined fault and fold geodatabase.

58 GEOSCIENCES↗

Locating fast-varying line disturbances with the frequency mismatch

In an attempt to provide an efficient method for line disturbance identification in complex networks of diffusively coupled agents, we recently proposed to leverage the frequency mismatch. The frequency mismatch filters out the intricate combination of interactions induced by the network structure and quantifies to what extent the trajectory of each agent is affected by the disturbance. In this previous work, we provided some analytical evidence of its efficiency when the perturbation is assumed to be slow. Here we claim that the frequency mismatch performs actually well for most disturbance regimes. This is shown through a series of simulations and is backed up by an analytical argument. Therefore, we argue that the frequency mismatch is an efficient and elegant tool for line disturbance location in complex networks of diffusively coupled agents.

97 MATHEMATICS AND COMPUTING↗

Report on High Energy Arcing Fault Experiments

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for medium voltage electrical switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers four of the fourteen planned medium voltage electrical enclosure experiments. Subsequent reports will document the additional experiments performed in the future. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the United States Nuclear Regulatory Commission (NRC), the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setups and execution. The HEAF experiments were performed on four near-identical units of General Electric metal-clad medium voltage switchgear. The three-phase arcing fault was initiated on the primary cable connection bus. All four experiments used the same system voltage (6.9 kV) but varied the current and duration. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers and slug calorimeters at various locations around the electrical enclosures. Internal enclosure pressures were measured during the experiments. The experiments were documented with normal and high-speed videography, infrared imaging, and photography. Insights from the experimental series included timing information related to enclosure breach, event progression, mass loss measurements for electrodes and steel enclosures, peak pressure rise, particle analysis, along with visual and thermal imaging data to better understand and characterize the hazard. These results will be used in subsequent efforts to advance the state of knowledge related to HEAF.

42 ENGINEERING↗

Relation Inference among Sensor Time Series in Smart Buildings with Metric Learning

Smart Building Technologies hold promise for better livability for residents and lower energy footprints. Yet, the rollout of these technologies, from demand response controls to fault detection and diagnosis, significantly lags behind and is impeded by the current practice of manual identification of sensing point relationships, e.g., how equipment is connected or which sensors are co-located in the same space. This manual process is still error-prone, albeit costly and laborious.We study relation inference among sensor time series. Our key insight is that, as equipment is connected or sensors co-locate in the same physical environment, they are affected by the same real-world events, e.g., a fan turning on or a person entering the room, thus exhibiting correlated changes in their time series data. To this end, we develop a deep metric learning solution that first converts the primitive sensor time series to the frequency domain, and then optimizes a representation of sensors that encodes their relations. Built upon the learned representation, our solution pinpoints the relationships among sensors via solving a combinatorial optimization problem. Extensive experiments on real-world buildings demonstrate the effectiveness of our solution.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Plate motion in sheared granular fault system

Plate motion near the fault gouge layer, and the elastic interplay between the gouge layer and the plate under stick-slip conditions, is key to understanding the dynamics of sheared granular fault systems. Here, a two-dimensional implementation of the combined finite-discrete element method (FDEM), which merges the finite element method (FEM) and the discrete element method (DEM), is used to explicitly simulate a sheared granular gouge fault system. In this work we focus on investigating the influence of normal load, driving shear velocity and plate stiffness on the velocities and displacements in the direction parallel to the shear direction (x-direction) measured at locations on the upper and lower plates just adjacent to the gouge. The simulations show that during slip phases the magnitudes of the measured velocities on the upper and lower plates are proportional to the normal load and may be inversely proportional to the square root of the plate's shear modulus. Whereas, the driving shear velocity does not show distinct influence on the measured velocities. Additionally, large slip velocities are generally associated with large macroscopic friction coefficient drops. For the models subjected to smaller normal loads, larger shear velocities and with stiffer shear plates, the same magnitude of slip velocity could cause a larger drop of macroscopic friction coefficient. During stick phases, the velocities of the upper and lower plates are respectively slightly greater and slightly smaller than half of the driving shear velocity and are both in the same direction of shear. The shear strain rate of the gouge is calculated from this velocity difference between the upper and lower plate during stick phases and thus the gouge effective shear modulus can be calculated. The results show that the gouge effective shear modulus increases proportionally with normal load, while the influence of shear velocity and plate stiffness on gouge effective shear modulus is minor. The simulations address the dynamics of a laboratory-scale fault gouge system and may aid in revealing the complexities of earthquake frictional dynamics.

58 GEOSCIENCES↗

Microseismicity Modulation Due To Changes in Geothermal Production at San Emidio, Nevada, USA

Brief cessations of geothermal production can induce seismicity, a phenomenon that has drawn increasing attention in recent years. Such observations are rare, and the underlying mechanism requires careful analysis. In April 2022, a dense seismic and hydrologic monitoring system was deployed at the San Emidio geothermal field, Nevada, to accompany a planned power plant shutdown. Using the dense seismic array data, we detected and located ∼1,800 microseismic events (MSEs) and developed a high-resolution tomographic P-wave velocity model. We observed substantially increased microseismicity during shutdown. Most MSEs occurred on pre-existing normal faults, which are contained within extremely low-velocity zones that are likely damaged, fluid-filled, and hydraulically connected to nearby production wells. Hydrologic data show rapid fluid pressure increases of <60 kPa following the shutdown. We suggest that the cessation of production rapidly increased fluid pressures along pre-existing fault zones, activating critically stressed fault patches and fractures and producing microseismicity.

Guo, Hao [University of Wisconsin-Madison, WI (Uni↗