Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

National Cost-Effectiveness of the Residential Provisions of the 2024 IECC

This analysis focuses on single-family and low-rise multifamily residential buildings based on the International Energy Conservation Code (IECC). The IECC is developed by the International Code Council (ICC) on a 3-year cycle through a public development and consensus process. While proponents of code changes often include the energy and cost-effectiveness criteria for their respective code change, the IECC process does not include an energy or cost-effectiveness analysis of the entire edition of the code. PNNL evaluated the cost effectiveness of the changes in the prescriptive and mandatory residential provisions of the 2024 edition of the IECC, hereafter referred as the 2024 IECC, compared to those in the prior edition, the 2021 IECC. The simulated performance path and the Energy Rating Index (ERI) path (introduced in the 2015 IECC) are not considered in this analysis due to the wide variation in building construction characteristics that are allowed.

2024 IECC↗

Energy Management Information Systems Technical Resources Report

Guide supports federal facility staff in understanding, designing, procuring, and implementing Energy Management Information Systems (EMIS) as a valuable component of their portfolio-level energy and water planning and management strategies. As a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance, EMIS tools present significant opportunities for federal sector energy savings and improved operational performance. EMIS are at the forefront of transforming energy management best practices by providing building owners and operators with well-organized building performance and energy consumption data, enabling a host of analytic capabilities. These capabilities include portfolio-wide energy benchmarking, data visualization, and key performance indicator tracking; automated fault detection and diagnostics (AFDD); artificial intelligence for predictive analytics and control; automated measurement and verification of energy conservation measures; and supervisory control enabling automated system optimization and demand management.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Guide to Energy Master Planning of High-Performance Districts and Communities

This guide was developed with partners throughout the United States to demonstrate how implementing district-scale high-performance strategies can be successful and scalable approaches to achieving deep energy savings that increase affordability, improve resilience, reduce emissions, and foster economic development. This document serves as a framework for districts, campuses, and communities, illustrating an iterative process of building support for, planning, and implementing high-performance districts by engaging stakeholders, setting aggressive energy goals, completing technical and financial planning, and implementing a high-performance energy master plan. The information in this guide is based on a 3-year U.S. Department of Energy Zero Energy District Accelerator and a range of real-world examples of emerging high-performance districts. It is particularly useful for architects, planners, engineers, local government agencies, and real estate developers in the early phases of planning a district with high-performance or other deep energy goals. For the purposes of this guide, a high-performance district is a multibuilding development that achieves aggressive energy and related goals such as zero energy, carbon neutrality, sustainability, ultra-efficiency, etc. High-performance districts optimize energy efficiency to reduce energy loads and use renewable energy resources to meet the remaining loads whenever possible. The Energy Independence and Security Act of 2007 defines a high-performance building as “a building that integrates and optimizes on a life cycle basis all major high-performance attributes, including energy conservation, environment, safety, security, durability, accessibility, cost-benefit, productivity, sustainability, functionality, and operational considerations.” High-performance districts are collections of such buildings that take advantage of the synergies available when energy consumption and production are considered at a district level rather than one building at a time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing Residential Energy Usage Baselines and Energy Efficiency Options

FCPC has been a leader in energy conservation not only in the State of Wisconsin, but nationally, as well. In 2016, the Environmental Protection Agency (EPA) ranked FCPC 11th in its Top 30 Local Government List as a result of the extensive measures the Tribe has taken toward its goal of achieving 100% carbon-neutral energy independence. Some of these efforts include the reduction of the Tribal government workweek to four days instead of five, the purchase of renewable energy certificates to more than offset the Tribe’s annual energy consumption, the installation of solar photovoltaic systems, and the completion of energy audits of Tribal government facilities. Until now, FCPC has focused on energy efficiency options for government and enterprise buildings, but it is now time to broaden the scope of energy efficiency to include the Tribe’s residential community. The Tribe’s Energy Working Group has identified the completion of home energy audits as one of its more imminent goals, as formal energy evaluations have yet to be completed on residential dwellings on the FCPC reservation. Tribal leadership is already looking ahead to the anticipated outcome of these energy audits and has taken steps to develop a cost sharing program that will assist Tribal homeowners to implement identified efficiency options as a result of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bay Area Regional Energy: Network Integrated Commercial Retrofits (BRICR) Project. Final Report

The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimizing PCM-integrated walls for potential energy savings in U.S. Buildings

Buildings in the United States account for nearly half of total U.S. energy use. The energy used for space conditioning can be reduced by utilizing thermal energy storage, such as phase change materials (PCMs), into building envelopes; however, the energy savings of PCM-integrated building envelopes reported in the literature vary widely. In the absence of established guidelines, thermophysical requirements of an optimal PCM, its method of application into the building envelope, and the corresponding energy savings under various climates remain unknown. Here, we perform an extensive numerical investigation on the integration of PCM into building walls to establish the key conditions required for effective utilization of PCM in reducing heat gains in the cooling season and heat losses in the heating season. We also determine the optimal transition temperature, optimal PCM location in the wall, and the energy-saving potential of the PCM-integrated building walls in five U.S. cities located in different International Energy Conservation Code climate zones. Results show that employing PCMs in building walls does not always lead to an improvement; in fact, incorrect applications of PCMs can substantially increase energy use in the buildings. In the climates we studied, PCMs were found effective in reducing heat gains during the cooling season while mostly ineffective in managing heat losses during heating season. Depending on the climate, optimized PCMs in U.S. building walls can provide reduction in the annual heat gain in the range of 3.5% to 47.2% and the annual heat loss in the range of -2.8% to 8.3%. Future consideration of buildings with substantial solar gains in winter may lead to more reduction in heat losses by PCMs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Model Building Energy Codes – Interim Update

The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates state and national impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, assessed the prospective impacts of national model building energy codes from 2010 through 2040. The model codes of interest in this report are the International Energy Conservation Code (IECC) for residential buildings and ASHRAE Standard 90.1 for commercial buildings. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions at the state and national levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling occupancy-driven building loads for large and diversified building stocks through the use of parametric schedules

Building energy modeling provides a fundamental tool to assess the potential for energy efficiency to contribute to reducing world energy consumption and global emissions. Occupancy-related operations are a key source of uncertainty for building energy analysis, particularly for aggregated building stocks. At a district or city level, it is critical to estimate aggregated power load profiles for sizing power grid infrastructure, power plant capacity allocation, and energy efficiency measures. The stochastic nature of behavior-related operations complicates the creation of models that accurately capture building load profiles for entire building stocks. This research introduces a new methodology called parametric schedules to model occupancy-driven schedules for large and diverse building stocks. In contrast to computationally expensive methodologies proposed in the literature, our work does not use a recursive time-consuming step. Occupancy is estimated by the extrapolation of operation times directly from metered electric consumption data; occupancy-related schedules are stochastically assigned to each building model, guaranteeing diversity of operation times in the stock. Our procedure has been tested on a large, diversified data-set of 25,000 commercial buildings in Los Angeles, California. It proved to be able to adequately represent the stochastic schedules diversity of the stock and to refine the stock calibration process by 1%. This innovative approach represents a useful asset for utility companies, grid operators, urban planners, and balancing authorities, seeking to improve building stock modeling and better estimate the impact of energy conservation measures. – This work is part of a larger stock modeling tool called ComStock, which is under development by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Model Building Energy Codes

The Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates state and national impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, assessed the prospective impacts of national model building energy codes from 2010 through 2040. The model codes of interest in this report are the International Energy Conservation Code (IECC) for residential buildings and ASHRAE Standard 90.1 for commercial buildings. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions at the state and national levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Model Building Energy Codes

The Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program. A 2016 study looked more broadly at overall code impacts and this report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced emissions at the state level and at aggregated levels. In 2021, DOE conducted an interim and limited update to its 2016 study to evaluate potential building code updates using the 2016 methodology. That interim update includes estimated savings resulting from updates to the model energy codes, including the ANSI/ASHRAE/IES Standard 90.1-2016 (ASHRAE 90.1-2016) and 2019 editions, as well as the 2018 and 2021 International Energy Conservation Code (IECC). In 2023, DOE developed a fully updated report that includes code updates (ASHRAE 90.1-2019 and 2021 IECC), as well as additional enhancements and updates, including updated energy prices, annual floorspace additions, state code adoption dates, and emission factors, among others. This current version is another fully updated report that includes code updates (ASHRAE 90.1-2022 and 2024 IECC), as well as additional enhancements and updates, including updated energy prices, state code adoption dates, emission factors, and renewable energy contribution among others. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when the new code is implemented and builders, architects, and engineers are required to comply with the new provisions. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. The contributions of all three phases are crucial to the overall impact of codes and are considered in this assessment. Figure ES.1 schematically describes the analysis framework. Energy savings are expressed in terms of energy use intensity (EUI) in the figure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Navigating the Use of Direct Current in Residential Settings: Merits and Obstacles

This review paper provides an in-depth analysis of the role of Direct Current (DC) power systems in residential settings, focusing on their safety, efficiency, and environmental advantages. It recognizes the significant contribution of the residential sector to global carbon dioxide emissions and explores how DC power systems can help mitigate these effects. The paper traces the historical evolution of DC power, its resurgence with renewable energy technologies, and the advancements in power electronics that facilitate its integration. Emphasizing the efficiency and safety benefits, especially in low-voltage applications, the paper highlights the seamless integration of DC systems with inherently DC-generating renewable sources like solar PV and wind. The review discusses the critical role of converter technologies in the transition to DC power and examines the compatibility of DC systems with energy storage solutions, underscoring their potential for enhanced energy management. It also addresses the environmental impacts of adopting DC power, aligning with global carbon reduction efforts. The paper analyzes regional case studies, exploring practical applications and outcomes, and addresses challenges such as the need for standardization. It concludes with recommendations for stakeholders and future research directions, emphasizing the economic, technological, and environmental aspects of DC power systems. Overall, the paper presents DC power as a viable and sustainable option for residential energy conservation, contingent upon ongoing technological progress, supportive policies, and standardization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating and Cooling Energy Modeling of 3D-Printed Concrete Construction of Residential Buildings [Slides]

3D printed concrete construction (C3DP) is an emerging technology that comes with the associated benefits of high thermal mass walls. We investigated using BEopt software the heating and cooling energy use of a single story C3DP-constructed house. We then compared the heating/cooling energy use of the C3DP house against the corresponding energy use in a traditional timber (wood) frame construction (WFC), as well as a concrete masonry unit (CMU) construction. Both peak energy use for heating and cooling (Btu), as well as base energy use for both heating and cooling (MMBtu/yr) of the C3DP design were compared against the WFC and CMU baseline construction of identical geometries and orientations across all eight climate zones defined in the International Energy Conservation Code (IECC). The BEopt models for all three constructions (C3DP, WFC, and CMU) were built to comply with the 2018 IECC code. Results indicate that C3DP construction has significant heating and cooling energy benefits in certain climate zones, with the highest peak cooling energy savings (9% compared to WFC, and 5% compared to CMU) in the IECC Climate Zone 1 in the month of July. The peak heating and cooling energy demand reduction of C3DP were found to be more significant than the base heating and cooling energy demand in all IECC climate zones. The 2018 IECC compliance-related U-Factor adjustments of all models also resulted in more peak energy savings of the C3DP design in the cooling-dominated climate zones (climate zones 1 and 2), moderate energy savings in moderate climate zones (climate zones 3, 4, and 6), and little to no change in energy savings in very cold climates (climate zones 7 and 8).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Analysis of ANN and LSTM Prediction Accuracy and Cooling Energy Savings through AHU-DAT Control in an Office Building

This paper proposes the optimal algorithm for controlling the HVAC system in the target building. Previous studies have analyzed pre-selected algorithms without considering the unique data characteristics of the target building, such as location, climate conditions, and HVAC system type. To address this, we compare the accuracy of cooling load prediction using ANN and LSTM algorithms, widely used in building energy research, to determine the optimal algorithm for HVAC control in the target building. We develop a simulation model calibrated with actual data to ensure data reliability and compare the energy consumption of the existing HVAC control method and the two algorithms-based methods. Results show that the ANN algorithm, with a CV(RMSE) of 12.7%, has a higher prediction accuracy than the LSTM algorithm, CV(RMSE) of 17.3%, making it a more suitable algorithm for HVAC control. Furthermore, implementing the ANN-based approach results in a 3.2% cooling energy reduction from the optimal control of Air Handling Unit (AHU) Discharge Air Temperature (DAT) compared to the fixed DAT at 12.8 °C in a representative day. This study demonstrates that ML-based HVAC system control can effectively reduce cooling energy consumption in HVAC systems, providing an effective strategy for energy conservation and improved HVAC system efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DSN energy data base preliminary design

The design and implementation of a computerized data base created to support the DSN Energy Conservation Project with data relating to energy use at Goldstone Deep Space Communications Complex are described. The results of development work to date, are presented along with work currently in progress or in the planning stage.

Cole, E. R.↗

High-Temperature, Wirebondless, Ultracompact Wide Bandgap Power Semiconductor Modules

Silicon carbide (SiC) and other wide bandgap semiconductors offer great promise of high power rating, high operating temperature, simple thermal management, and ultrahigh power density for both space and commercial power electronic systems. However, this great potential is seriously limited by the lack of reliable high-temperature device packaging technology. This Phase II project developed an ultracompact hybrid power module packaging technology based on the use of double lead frames and direct lead frame-to-chip transient liquid phase (TLP) bonding that allows device operation up to 450 degC. The new power module will have a very small form factor with 3-5X reduction in size and weight from the prior art, and it will be capable of operating from 450 degC to -125 degC. This technology will have a profound impact on power electronics and energy conversion technologies and help to conserve energy and the environment as well as reduce the nation's dependence on fossil fuels.

Elmes, John↗

Numerical Modeling of Boiling in a Heated Tube

This paper presents numerical models of boiling in a heated tube using the Generalized Fluid System Simulation Program (GFSSP), a finite-volume-based general-purpose flow network code developed at NASA/Marshall Space Flight Center. The heated tube is discretized into a one-dimensional array of nodes and branches to represent the flow of liquid and vapor in a tube with a prescribed pressure differential. The solid wall is also discretized into solid nodes and conductors to allow for heat transfer between the wall and the fluid. The conservation equations of mass, momentum, and energy of the fluid are solved simultaneously with the energy conservation equation for the solid wall. Two experimental configurations of fluid flowing in a vertical tube have been simulated, one with water and the other with liquid hydrogen. This paper compares experimental data with numerical predictions based on four different published correlations for boiling heat transfer coefficients. Three of these correlations are applicable to the saturated vertical flow conditions of the experiments. One of them is applicable to film boiling and has been used for the liquid hydrogen experiment, which was in film boiling regime. For the case of boiling water, the predictions of wall temperatures using the boiling heat transfer correlations agreed well with the experimental results. However, in the case of boiling hydrogen larger discrepancies were observed between the experimental data and numerical predictions.

Majumdar, Alok↗

Assessment of Existing OpenStudio Measures: Reviews, Interviews, and Future Developments

OpenStudio Measure development is continuously in progress and greatly propelled by the collaborative efforts within the building energy modeling community. To ensure the widespread adoption and benefit of OpenStudio Measures, developers must understand the current status of Measure development and the needs of OpenStudio Measure users. The first step involves a comprehensive review of existing content to prevent redundancy and gain insights into how OpenStudio Measures are used in the building energy modeling community. This knowledge can then be integrated into the Measure development process, and the expertise of practitioners and OpenStudio Measure users can be leveraged to shape future Measures. Numerous OpenStudio Measures have been created and shared on the Building Component Library (BCL). The BCL is an open-source repository housing various OpenStudio-related resources, including building component blocks, descriptive metadata, and Measures describing modifications to building energy models. The OpenStudio Measures in BCL encompass a wide range of energy conservation Measures from basic lighting power reduction to complex HVAC model transformation. They also enable users to generate customized reports and facilitate the integration of energy simulation with other analytical processes. This report presents review of 272 currently available OpenStudio Measures in BCL. The OpenStudio Measures were reviewed by category and subcategory. These Measures are summarized by their functionalities and keywords. To gain insights into how OpenStudio Measures are used in building energy modeling community, interviews were conducted. A total of 12 interview responses were collected from 6 individuals in the industry and 6 individuals in academia. The knowledge acquired from reviewing the existing Measures and interview results will be integrated into the Measure development process, and the expertise of practitioners and OpenStudio Measure users will be leveraged to shape future Measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prefabricated Zero Energy Retrofit Technologies: A Market Assessment

Part of the U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy’s (EERE’s) strategic goals is to stimulate the growth of a thriving domestic clean energy manufacturing industry. This report seeks to identify products in the European and U.S. markets that can enable a more integrated and standardized approach to conducting zero energy retrofits, leveraging off-site construction and manufacturing. Greater integration of energy conservation measures into prefabricated building components will further enable efficiency adoption, while reducing project complexity, risks, and costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗