Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Picosecond laser generated plasma as a source of singly charged ions for external injection into an EBIS

The focus of this paper is on practical aspects of ion generation by picosecond lasers as a source of low charge state ions for external injection of ions into an electron beam ion source (EBIS). For a ps-laser, compared to a ns-laser currently used at Relativistic Heavy Ion Collier Electron Beam Ion Source (RHIC EBIS), the influence of heat conductivity in the solid target is almost negligible, which results in a lower target consumption rate and less vacuum pressure rise. By using a laser with high repetition rate, it is possible to produce quasi continuous 1+ ion beams for periods of tens of milliseconds, making it possible to take advantage of the ability of the EBIS to accumulate ions in the “slow” injection capture mode. Producing such an ion pulse train is now feasible since ps-lasers with pulse energy up to 10 mJ and rep-rate up to 10 kHz have recently become commercially available. The advantages of this lower current accumulation scheme include: (1) easier beam transport due to lower space charge of lower beam currents required compared to the present single pulse fast injection scheme, (2) better EBIS pulse to pulse ion output stability since pulse to pulse ion variations of the laser source are averaged over a long train of laser pulses, and (3) the possible addition of an isotope separator in which rare beams could be produced and selected at run time from less expensive (unenriched) targets. We studied the properties of plasmas generated by a ps-laser with 1.27 mJ energy within an 8 ps pulse and a repetition rate up to 400 Hz at Argonne National Laboratory to investigate feasibility and specify parameters for a laser ion source for RHIC EBIS using a “slow” injection mode. Al, Ti, Cu, Nb, and Ta targets were tested with various target translation speeds. Here, we demonstrated that a both “slow” and “fast” injection modes are accessible with a single ion source geometry and single injection line, providing the most attractive option for an ion source for external injection into RHIC EBIS trap based on a ps-laser.

43 PARTICLE ACCELERATORS↗

IsoDAR@Yemilab: Preliminary design report—volume I (cyclotron driver)

This Preliminary Design Report (PDR) describes the IsoDAR electron-antineutrino source in two volumes which are mostly site-independent and describe the cyclotron driver providing a 10 mA/60 MeV proton beam (this Volume); and the medium energy beam transport line (MEBT) and target (Volume II). The IsoDAR driver and target will produce about 1.15 x 10 23 electron-antineutrinos over 5 years while operating with the anticipated 10 mA/60 MeV beam at an estimated 80% duty factor. Paired with a kton-scale liquid scintillator detector, it will enable a broad particle physics program including searches for new symmetries, new interactions and new particles. Here in Volume I, we describe the driver, which includes the ion source, low energy beam transport, and cyclotron. The latter features Radio-Frequency Quadrupole (RFQ) direct axial injection and represents the first accelerator purpose-built to make use of so-called vortex motion.

Winklehner, Daniel (ORCID:0000000207156310)↗

Thermionic microwave gun for terahertz and synchrotron light sources

Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.

47 OTHER INSTRUMENTATION↗

Design of high-performance guns for the HL-LHC HEL

The High Luminosity LHC project (HL-LHC) foresees the construction and installation of important new equipment to increase the performance of the LHC machine. The Hollow Electron Lens (HEL) is a promising system to control the beam halo. It improves the beam collimation system of the HL-LHC and mitigates possible equipment damage in case of failure scenarios from halo losses. The halo can store up to 30 MJ energy. The specifications for this new device are quite demanding. The source, an electron gun with an annular shaped cathode, must deliver a current up to 5 A. Additionally, this is five times higher than the current in the existing electron lenses in Fermi and Brookhaven national laboratories. This note describes the programme carried out to design and test high-perveance guns equipped with two types of high-performance scandate cathodes. The size of the final gun for the HL-LHC lenses is now considerably smaller than the one of the first prototype, allowing a reduction of diameter and cost of the superconducting magnet system used to steer the electron beam. The tests carried out at FNAL, BVERI and BJUT demonstrated that the developed cathodes fulfil the specifications and can supply a 5 A fully Space Charge Limited (SCL) current.

43 PARTICLE ACCELERATORS↗

The DREAM Endstation at the Linac Coherent Light Source

Free-electron lasers (FEL), with their ultrashort pulses, ultrahigh intensities, and high repetition rates at short wavelength, have provided new approaches to Atomic and Molecular Optical Science. One such approach is following the birth of a photo electron to observe ion dynamics on an ultrafast timescale. Such an approach presents the opportunity to decipher the photon-initiated structural dynamics of an isolated atomic and molecular species. It is a fundamental step towards understanding single- and non-linear multi-photon processes and coherent electron dynamics in atoms and molecules, ultimately leading to coherent control following FEL research breakthroughs in pulse shaping and polarization control. A key aspect for exploring photoinduced quantum phenomena is visualizing the collective motion of electrons and nuclei in a single reaction process, as dynamics in atoms/ions proceed at femtosecond (10 –15 s) timescales while electronic dynamics take place in the attosecond timescale (10 –18 s). Here, we report on the design of a Dynamic Reaction Microscope (DREAM) endstation located at the second interaction point of the Time-Resolved Molecular and Optical (TMO) instrument at the Linac Coherent Light Source (LCLS) capable of following the photon–matter interactions by detecting ions and electrons in coincidence. The DREAM endstation takes advantage of the pulse properties and high repetition rate of LCLS-II to perform gas-phase soft X-ray experiments in a wide spectrum of scientific domains. With its design ability to detect multi-ions and electrons in coincidence while operating in step with the high repetition rate of LCLS-II, the DREAM endstation takes advantage of the inherent momentum conservation of reaction product ions with participating electrons to reconstruct the original X-ray photon–matter interactions. In this report, we outline in detail the design of the DREAM endstation and its functionality, with scientific opportunities enabled by this state-of-the-art instrument.

47 OTHER INSTRUMENTATION↗

Temperature of Suprathermal Electron Strahl at ACE as an Indicator of Solar Coronal Origin Temperature [Slides]

Determine the effectiveness of using electron strahl temperature to infer coronal source temperature. Suprathermal electron strahl temperature derived from measurements at 1 AU does retain information regarding the coronal source temperature from which it originates. This correlation is most strongly measured during the leading edges of coronal hole events but is generally also present in full event measurements. This correlation is also observed in CME events during a coronal hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Rnf and Fix Have Specific Roles during Aerobic Nitrogen Fixation in Azotobacter vinelandii

Biological nitrogen fixation requires large amounts of energy in the form of ATP and low potential electrons to overcome the high activation barrier for cleavage of the dinitrogen triple bond. The model aerobic nitrogen-fixing bacteria, Azotobacter vinelandii, generates low potential electrons in the form of reduced ferredoxin (Fd) and flavodoxin (Fld) using two distinct mechanisms via the enzyme complexes Rnf and Fix. Both Rnf and Fix are expressed during nitrogen fixation, but deleting either rnf1 or fix genes has little effect on diazotrophic growth. However, deleting both rnf1 and fix eliminates the ability to grow diazotrophically. Rnf and Fix both use NADH as a source of electrons, but overcoming the energetics of NADH's endergonic reduction of Fd/Fld is accomplished through different mechanisms. Rnf harnesses free energy from the chemiosmotic potential, whereas Fix uses electron bifurcation to effectively couple the endergonic reduction of Fd/Fld to the exergonic reduction of quinone. Different reaction stoichiometries and condition-specific differential gene expression indicate specific roles for the two reactions. This work's complementary physiological studies and thermodynamic modeling reveal how Rnf and Fix balance redox homeostasis in various conditions. Specifically, the Fix complex is required for efficient growth under low oxygen concentrations, while Rnf is presumed to maintain reduced Fd/Fld production for nitrogenase under standard conditions. This work provides a framework for understanding how the production of low potential electrons sustains robust nitrogen fixation in various conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Electron energization during merging of self-magnetized, high-beta, laser-produced plasmas

Electron energization during merging of magnetized plasmas is studied using the OMEGA and OMEGA EP laser facilities by colliding two plasma plumes, each containing a Biermann-battery self-generated magnetic field. Two neighbouring plasma plumes are produced by intense laser beams, and the anti-parallel Biermann fields merge and reconnect in the process of the plumes’ expansion and collision. To isolate the merging as an acceleration source, the electron energy spectra obtained from two-plume collision shots are compared with the spectra from single-plume shots. Single-plume shots exhibit an energized electron tail with energies up to ${\sim }250\ \textrm {keV}$ . The electrons in merging experiments are additionally accelerated by ${\sim }50\text {--}100$ keV compared to single-plume shots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray free-electron laser based dark-field X-ray microscopy: a simulation-based study

Dark-field X-ray microscopy (DFXM) is a nondestructive full-field imaging technique providing three-dimensional mapping of microstructure and local strain fields in deeply embedded crystalline elements. This is achieved by placing an objective lens in the diffracted beam, giving a magnified projection image. So far, the method has been applied with a time resolution of milliseconds to hours. In this work, the feasibility of DFXM at the picosecond time scale using an X-ray free-electron laser source and a pump–probe scheme is considered. Thermomechanical strain-wave simulations are combined with geometrical optics and wavefront propagation optics to simulate DFXM images of phonon dynamics in a diamond single crystal. Using the specifications of the XCS instrument at the Linac Coherent Light Source as an example results in simulated DFXM images clearly showing the propagation of a strain wave.

47 OTHER INSTRUMENTATION↗

Design and construction of a compact, high-repetition-rate ultrafast electron diffraction instrument

We present the design and performance of a compact ultrafast electron diffraction instrument. The diffractometer provides a means of examining time-resolved ultrafast dynamical properties of solids. The system’s utilization is discussed in terms of instrument parameters and diffraction data from selected condensed matter samples. Here, the difractometer’s performance is highlighted in terms of detection sensitivity, instrumental temporal resolution, and the electron beam transverse coherence length. Following specific details of the construction, we present a practical discussion of parameters such as repetition rate and provide advice on general construction approaches for laboratory-based, keV ultrafast electron diffractometers. In addition, design guidance for constructing a compact electron gun source that is well-suited for studying diffraction from hard condensed matter is given. A unique data acquisition scheme, utilizing high laser repetition rates, is presented.

47 OTHER INSTRUMENTATION↗

Inorganic Halide Perovskitoid TlPbI 3 for Ionizing Radiation Detection

Room temperature semiconductor detector (RTSD) materials for γ-ray and X-ray radiation are in great demand for the nonproliferation of nuclear materials as well as for biomedical imaging applications. Halide perovskites have attracted great attention as emerging and promising RTSD materials. In this contribution, the material synthesis, purification, crystal growth, crystal structure, photoluminescence properties, ionizing radiation detection performance, and electronic structure of the inorganic halide perovskitoid compound TlPbI 3 are reported on. This compound crystallizes in the ABX 3 non-perovskite crystal structure with a high density of d = 6.488 g·cm –3 , has a wide bandgap of 2.25 eV, and melts congruently at a low temperature of 360 °C without phase transitions, which allows for facile growth of high quality crystals with few thermally-activated defects. High-quality TlPbI 3 single crystals of centimeter-size are grown using the vertical Bridgman method using purified raw materials. A high electrical resistivity of ≈10 12 Ω·cm is readily obtainable, and detectors made of TlPbI 3 single crystals are highly photoresponsive to Ag K α X-rays (22.4 keV), and detects 122 keV γ-rays from 57 Co radiation source. The electron mobility-lifetime product µ e τ e was estimated at 1.8 × 10 –5 cm 2 ·V –1 . A high relative static dielectric constant of 35.0 indicates strong capability in screening carrier scattering and charged defects in TlPbI 3 .

36 MATERIALS SCIENCE↗

On the Source of Conductivity in Alkaline Zn Anodes: Zn Percolation and ZnO Bridging

Alkaline Zn anodes are fundamental to commercial Zn-MnO 2 batteries as well as emerging rechargeable designs. In these electrodes, Zn particles are both the active material and source of electronic conduction. However, there are known cases in which electronic connectivity between Zn particles or the current collecting pin is lost even though the battery continues to function. Here we use X-ray computed tomography (CT) of AA batteries to demonstrate several examples of Zn particle-to-particle connectivity breakdown, which is observed even in cases at relatively high discharge rate. This indicates maintenance of the electronic network through the less-conductive ZnO discharge product. We introduce a new equation for electronic conductivity maintained through bridges of ZnO formed between percolating Zn particles. This necessitates discarding the Bruggeman correlation and instead redefining effective electronic conductivity using percolation theory. We demonstrate that such a model for conduction enables prediction of an inverted reaction zone, which is an experimentally observed case in which significant Zn dissolution and ZnO formation occurs heavily near the current collecting pin. Current computational Zn-MnO 2 models never predict an inverted reaction zone, and thus the updated conductivity enables models to accurately explain a wider range of experimental conditions.

Guida, Dominick P. [Northeastern Univ., Boston, MA↗

Preface to the JPCM special issue on intense radiation sources in condensed matter and materials physics

This special issue is designed to honour the contributions of our colleague Neville Greaves who was among the first to apply newly-available synchrotron x-ray techniques to study the synthesis, structures and properties of advanced materials [1, 2]. His wide ranging work on ceramics, glasses and nanomaterials was celebrated in a recent issue of the J. Non-Cryst. Solids [3]. Neville's contributions to synchrotron research, highlighted here, focussed on design and construction of new beamline capabilities and sample environments to probe materials under different physical and chemical conditions, integrating various techniques to obtain complementary data on structure and bonding. The innovative nature of his work is illustrated by his studies of liquids and glasses, where he incorporated aerodynamic levitation into these experimental techniques, using both synchrotron x-ray and neutron beams to probe the structural transformations and dynamics combined with molecular dynamics simulations to study atomic scale organisation. His work has had a major impact on fundamental condensed matter physics and chemistry as well as applied materials science; and in this issue, we present contributions from colleagues using and developing new experimental techniques at current and next-generation synchrotron, neutron and free-electron laser sources and in their own laboratories, that probe the fundamental physics, chemistry and functional properties of novel materials and processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A sensitive high repetition rate arrival time monitor for X-ray free electron lasers

X-ray free-electron laser sources enable time-resolved X-ray studies with unmatched temporal resolution. To fully exploit ultrashort X-ray pulses, timing tools are essential. However, new high repetition rate X-ray facilities present challenges for currently used timing tool schemes. Here we address this issue by demonstrating a sensitive timing tool scheme to enhance experimental time resolution in pump-probe experiments at very high pulse repetition rates. Our method employs a self-referenced detection scheme using a time-sheared chirped optical pulse traversing an X-ray stimulated diamond plate. By formulating an effective medium theory, we confirm subtle refractive index changes, induced by sub-milli-Joule intense X-ray pulses, that are measured in our experiment. The system utilizes a Common-Path-Interferometer to detect X-ray-induced phase shifts of the optical probe pulse transmitted through the diamond sample. Owing to the thermal stability of diamond, our approach is well-suited for MHz pulse repetition rates in superconducting linear accelerator-based free-electron lasers.

47 OTHER INSTRUMENTATION↗

Electron Cloud Simulations for the Electron-Ion Collider in Brookhaven National Laboratory

For high-intensity circular accelerators and storage rings, if the secondary electron emission yield (SEY) of the vacuum chamber surfaces is high, an EC (Electron Cloud) could build up with the passage of the circulating beam. The presence of EC can strongly affect the beam quality, such as transverse instabilities, transverse emittance growth, and beam loss. Furthermore, the heat load from EC can exceed the available cryogenic capability. For the RHIC superconducting (SC) arc magnets, to be used for the hadron storage ring of the Electron-Ion Collider (EIC), the dynamic heat load budget is 0.5 W/m to the 4.5 K stainless steel beam pipe. This can limit the maximum beam bunches or intensity of the EIC, hence diminishing the luminosity provided by the EIC. The EC has affected the beam instability and significantly contributed to cryogenic heat load in the Large Hadron Collider (LHC). Positron storage rings for which ECs have been a critical factor in the design and performance include KEKB in Japan and EC buildup remains one of the concerns for future high-intensity accelerators design. EC considerations have driven the SuperKEKB collider design and the positron damping ring for the proposed International Linear Collider (ILC). The LHC luminosity upgrade is contingent on reducing the bunch spacing to 25 ns; at this bunch spacing, severe EC buildup has been observed. The success of the upgrade is likely contingent on limiting EC buildup. To study the EC heat load, we did some EC simulations with PyECLOUD code for the dipole, quadrupole, sextupole magnets, and the warm (drift) section of the EIC hadron storage ring. PyECLOUD is an EC simulation code developed by CERN. The code has been validated and used to study EC in the LHC, SPS, and PS. To eliminate EC buildup, the sources of electrons must be minimized. First, we will reduce the production of electrons due to residual gas ionization by specifying the maximum gas density, which requires a vacuum chamber with low electron-stimulated desorption (ESD) yields and a sufficient (preferably distributed) pumping speed. Second, we should reduce the secondary electrons with a lower secondary electron yield (SEY) material.

43 PARTICLE ACCELERATORS↗

Modular multi-interface nanocrystals for enhanced ethanol oxidation electrocatalysis

Electrochemical processes that utilize biomass-derived ethanol as a source of electrons and protons offer a sustainable energy strategy, yet their practical implementation is limited by sluggish ethanol oxidation reaction (EOR) kinetics and catalyst poisoning. Here, in this study, we report a modular multi-interface nanocrystal catalyst comprising core/shell Co 2 P/Pd and Pd-Au heterostructured interfaces that exhibit complementary functions for the enhanced EOR catalysis. The Co 2 P/Pd interface boosts Pd atom utilization and lowers the kinetic barriers for ethanol-to-acetate conversion, while the Pd-Au interface effectively alleviates CO poisoning caused by C–C bond cleavage of ethanol. In-depth analyses using in situ attenuated total reflectance-surface-enhanced infrared absorption spectroscopy, differential electrochemical mass spectrometry, and density functional theory calculations elucidate the mechanistic roles of these interfaces. The optimized Co 2 P/Pd-Au 0.08 nanorods achieve an excellent mass activity, underscoring the potential of modular, multi-interface nanocrystals for advancing EOR catalysis and offering a generalizable strategy for broader catalytic innovations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On ultrafast x-ray scattering methods for magnetism

With the introduction of x-ray free electron laser sources around the world, new scientific approaches for visualizing matter at fundamental length and time-scales have become possible. As it relates to magnetism and ‘magnetic-type’ systems, advanced methods are being developed for studying ultrafast magnetic responses on the time-scales at which they occur. We describe three capabilities which have the potential to seed new directions in this area and present original results from each: pump-probe x-ray scattering with low energy excitation, x-ray photon fluctuation spectroscopy, and ultrafast diffuse x-ray scattering. By combining these experimental techniques with advanced modeling together with machine learning, we describe how the combination of these domains allows for a new understanding in the field of magnetism. Finally, we give an outlook for future areas of investigation and the newly developed instruments which will take us there.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗