Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Characterization of the ATLAS Liquid Argon Front-End ASIC ALFE2 for the HL-LHC upgrade

In this study, ALFE2 is an ATLAS Liquid Argon Calorimeter (LAr) Front-End ASIC designed for the HL-LHC upgrade. ALFE2 comprises four channels of pre-amplifiers and CR-(RC) 2 shapers with adjustable input impedance. ALFE2 features two separate gain outputs to provide 16-bit dynamic-range coverage and an optimum resolution. ALFE2 is characterized using a Front-End Test Board (FETB) based on a Zynq UltraScale+ MPSoC and two octal-channel 16-bit high-speed ADCs. The test results indicate that ALFE2 fulfills or greatly exceeds all specifications on gain, noise, linearity, uniformity, and radiation tolerance.

47 OTHER INSTRUMENTATION↗

The Mu2e experiment

The Mu2e experiment, currently under construction at Fermilab, will search for neutrinoless mu->e conversion in the field of an aluminum atom. A clear signature of this chargedlepton flavor violating two-body process is given by the monoenergetic conversion electron of 104.97 MeV produced in the final state.An 8 GeV/c pulsed proton beam interacting on a tungsten target will produce the pions decaying in muons; a set of superconducting magnets will drive the negative muon beam to a segmented aluminum target where the stopped muons will eventually convert to electrons; a set of detectors will be used to both identify conversion electrons and reject beam and cosmic backgrounds.The experiment will need 3-5 years of data-taking to achieve a factor of $10^4$ improvement on the current best limit on the conversion rate.After an introduction to the physics of Mu2e, we will report on the status of the different components of the experimental apparatus. The updated estimate of the experiment’s sensitivity and discovery potential will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A neutrino floor for the Migdal effect

Neutrino-nucleus scatterings in the detector could induce electron ionization signatures due to the Migdal effect. We derive prospects for a future detection of the Migdal effect via coherent elastic solar neutrino-nucleus scatterings in liquid xenon detectors, and discuss the irreducible background that it constitutes for the Migdal effect caused by light dark matter-nucleus scatterings. Furthermore, we explore the ionization signal induced by some neutrino electromagnetic and non-standard interactions on nuclei. In certain scenarios, we find a distinct peak on the ionization spectrum of xenon around 0.1 keV, in clear contrast to the Standard Model expectation.

Experimental Nuclear Physics↗

Experimental evidence of hole injection through V-defects in long wavelength GaN-based LEDs

Hole injection through V-defect sidewalls into all quantum wells (QWs) of long wavelength GaN light emitting diodes had previously been proposed as means to increase efficiency of these devices. In this work, we directly tested the viability of this injection mechanism by electroluminescence and time-resolved photoluminescence measurements on a device in which QW furthest away from the p-side of the structure was deeper, thus serving as an optical detector for presence of injected electron–hole pairs. Emission from the detector well confirmed that, indeed, the holes were injected into this QW, which could only take place through the {$10\bar{1}1$} V-defect sidewalls. Unlike direct interwell transport by thermionic emission, this transport mechanism allows populating all QWs of a multiple QW structure despite the high potential barriers in the long wavelength InGaN/GaN QWs.

Atomic force microscopy↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV detector

We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of 6.1 g · days of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as 1 MeV/𝑐 2 , as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses >1.2 eV/𝑐 2 probed via absorption processes.

dark matter direct detection↗

Real-time data reduction at 100 Tbps: Challenge and opportunity for AI-based data reduction for next-generation large-scale nuclear physics collider experiment

The modern large-scale nuclear physics (NP) experiments in high-energy particle colliders utilize streaming-readout electronics to digitize detector response at O(100) Tbps bandwidth. Prominent examples at Brookhaven National Lab (BNL) include the sPHENIX experiment at Relativistic Heavy Ion Collider (RHIC), which is under construction, and the experiments proposed for the Electron-Ion Collider (EIC), planned for the 2030s . One of the main challenges for these streaming readout systems is to manage the data rate with sufficient data reduction in real time so the end-data fit persistent storage for offline analysis, which is typically at O(1000) times smaller and O(100) Gbps. Such data reduction traditionally is achieved via real-time high level triggers, which select and save a small subset of collisions of interest. Although triggering is applicable to high energy collider experiments such as those at the Large Hardron Collider at CERN, it is insufficient for these nuclear physics experiments which study diverse collision topologies. And traditional triggering approach is inefficient to preserve the max information harvested from the operation of colliders that costs O(100)M per year to DOE. Meanwhile, in recent years, ML-based high-throughput data reduction has emerged as a promising approach to efficiently preserve max information for a given space of persistent storage, e.g. via AI data compression, feature extraction, and noise filtering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low mass dark matter-electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross-sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axion-like particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20–300 GeV/c

The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly read out by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Measurement of the Electron-Neutrino Charged-Current Pion Production Cross Section on Carbon with the T2K Near Detector

The T2K Collaboration presents the first measurement of electron neutrino-induced charged-current pion production on a predominantly carbon target in a restricted kinematical phase space. This is performed using data from the 2.5° off-axis near detector, ND280. The differential cross sections with respect to the outgoing electron and pion kinematics, in addition to the total flux-integrated cross section, are obtained. Comparisons between the measured and predicted cross-section results using the neut, genie, and nuwro Monte Carlo event generators are presented. The measured total flux-integrated cross section is [2.52 ± 0.52⁢(stat) ± 0.30⁢(syst)] × 10 −39 cm 2 nucleon −1 , which is lower than the event generator predictions.

Neutrinos↗

Development and test of a mini-Data Acquisition system for the High-Luminosity LHC upgrade of the ATLAS Monitored Drift Tube detector

New front-end electronics including ASICs and FPGA boards are under development for the ATLAS Monitored Drift Tube (MDT) detector to handle the large data rates and harsh environment expected at high-luminosity LHC runs. A mobile Data Acquisition (miniDAQ) system is designed to perform integration tests of these front-end electronics. In addition, it will be used for surface commissioning of 96 small-radius MDT (sMDT) chambers and for integration and commissioning of new front-end electronics on the present ATLAS MDT chambers. Details of the miniDAQ hardware and firmware are described in this article. Here, the miniDAQ system is also used to read out new front-end electronics on an sMDT prototype chamber using cosmic muons and results obtained are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector architecture and data flow of the CMS HGCAL Phase-2 Endcap Calorimeter Upgrade

The CMS High Granularity Calorimeter (HGCAL) is the Phase-2 endcap calorimeter upgrade for the High-Luminosity Large Hadron Collider, designed to provide precise spatial, energy, and timing measurements in a high-radiation, high-pileup environment. This work presents an overview of the HGCAL assembly process, detector architecture, and end-to-end data flow. The data flow goes from signal generation in silicon sensors and scintillator tiles through front-end electronics, optical transmission, and back-end data acquisition. The study highlights how the integrated detector, electronics, and readout systems enable efficient event reconstruction and support the physics objectives of the HL-LHC.

Osei Boakye, Prince [Grambling State U.]↗

A radiation tolerant clock generator for the CMS endcap timing layer readout chip

Here, we present the test results of a low jitter Phase Locked Loop (PLL) prototype chip for the CMS Endcap Timing Layer readout chip (ETROC). This chip is based on the improved version of a clock synthesis circuit named ljCDR from the Low Power Gigabit Transceiver (lpGBT) project. The ljCDR is tested in its PLL mode. An automatic frequency calibration (AFC) block with the Triple Modular Redundancy (TMR) register is developed for the LC-oscillator calibration. The chip was manufactured in a 65 nm CMOS process with 10 metal layers. The chip has been extensively tested, including Total Ionizing Dose (TID) testing up to 300 Mrad and Single Event Upset (SEU) testing with heavy ions possessing a Linear Energy Transfer (LET) from 1.3 to 62.5 MeV × cm 2 /mg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytic model of electron transport through and over non-linear barriers

Tunneling barriers are an essential component of electron sources, sensors, detectors, and vacuum nanoelectronics, and a pivotal factor in their performance, but the barriers themselves routinely depart from the analytic models used to model their behavior. Here, a new formalism is developed to analytically and accurately model emission through and over barriers associated with depletion layers, nanotip barriers, and MIM structures. The transmission probability for depletion layer and metal-insulator-metal (MIM) and metaloxide-semiconductor (MOS) barriers is accurately modeled as the electron energy exceeds the barrier height using approaches designed for rapid implementation demanded by simulation codes, and extensible to general barriers. The models supersede conventional thermal and field models in depletion and MIM/MOS barrier studies. Thermal-field methods are used to treat the transmission probability, and shape factor methods to treat the tunneling factor. Analytic formulae for current density are obtained. The methods ease device simulation and characterization of current-voltage relations for emerging technologically interesting barriers with better accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accounting for electron-beam-induced warping of molecular nanocrystals in MicroED structure determination

High-energy electrons induce sample damage and motion at the nanoscale to fundamentally limit the determination of molecular structures by electron diffraction. Using a fast event-based electron counting (EBEC) detector, we characterize beam-induced, dynamic, molecular crystal lattice reorientations (BIRs). These changes are sufficiently large to bring reciprocal lattice points entirely in or out of intersection with the sphere of reflection, occur as early events in the decay of diffracted signal due to radiolytic damage, and coincide with beam-induced migrations of crystal bend contours within the same fluence regime and at the same illuminated location on a crystal. These effects are observed in crystals of biotin, a series of amino acid metal chelates, and a six-residue peptide, suggesting that incident electrons inevitably warp molecular lattices. The precise orientation changes experienced by a given microcrystal are unpredictable but are measurable by indexing individual diffraction patterns during beam-induced decay. Reorientations can often tilt a crystal lattice several degrees away from its initial position before irradiation, and for an especially beam-sensitive Zn(II)-methionine chelate, are associated with dramatic crystal quakes prior to 1 e − Å −2 electron beam fluence accumulates. Since BIR coincides with the early stages of beam-induced damage, it echoes the beam-induced motion observed in single-particle cryoEM. As with motion correction for cryoEM imaging experiments, accounting for BIR-induced errors during data processing could improve the accuracy of MicroED data.

Vlahakis, Niko (ORCID:0000000250920265)↗

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗