Nonthermal Bonding Origin of a Novel Photoexcited Lattice Instability in SnSe

Lattice dynamics measurements are often crucial tools for understanding how materials transform between different structures. Here, we report time-resolved x-ray scattering-based measurements of the nonequilibrium lattice dynamics in SnSe, a monochalcogenide reported to host a novel photoinduced lattice instability. By fitting interatomic force models to the fluence dependent excited-state dispersion, we determine the nonthermal origin of the lattice instability to be dominated by changes of interatomic interactions along a bilayer-connecting bond, rather than of an intralayer bonding network that is of primary importance to the lattice instability in thermal equilibrium.

36 MATERIALS SCIENCE↗

Dynamical Decoupling for Measuring and Suppressing Crosstalk

Dynamical decoupling (DD) is a noise-mitigating strategy in which sequences of pulses are applied to single qubits to average out their interaction with the environment. DD has been extensively studied and demonstrated for suppressing single-qubit decoherence and can be tailored for different noise spectrum. We report another important adaptation of DD where crosstalk between qubits are suppressed. We demonstrate the efficiency of this procedure on quantum circuits on superconducting transmon-based quantum devices. We designed a family of syncopated DD sequences that effectively suppress ZZ coupling between qubit pairs, which is the dominating crosstalk form on the device. We insert DD to a quantum circuit whenever single qubits are idle (often during two-qubits gates on other qubits). While standard periodic DD suppress crosstalk between these qubits and their neighbors, the syncopated DD further decouples crosstalk between these qubits. We further designed short sequences that maximize the application of DD without adding time to the quantum circuit execution. Such DD sequences yield significant improvement of the performance of the algorithm on the hardware. The performance is further boosted by combining DD with another mitigation strategy, randomized compilation. Our work demonstrated that syncopated DD is effective and practical way to suppress crosstalk in quantum circuits and serves as a great probe to characterize the crosstalk and inform hardware design.

Quantum Computing↗

Further development of the dynamic gas temperature measurement system. Volume 1: Technical efforts

A compensated dynamic gas temperature thermocouple measurement method was experimentally verified. Dynamic gas temperature signals from a flow passing through a chopped-wheel signal generator and an atmospheric pressure laboratory burner were measured by the dynamic temperature sensor and other fast-response sensors. Compensated data from dynamic temperature sensor thermoelements were compared with fast-response sensors. Results from the two experiments are presented as time-dependent waveforms and spectral plots. Comparisons between compensated dynamic temperature sensor spectra and a commercially available optical fiber thermometer compensated spectra were made for the atmospheric burner experiment. Increases in precision of the measurement method require optimization of several factors, and directions for further work are identified.

Elmore, D. L.↗

Instantaneous stroke volume in man during lower body negative pressure /LBNP/

Results of an examination of the instantaneous time course of the stroke volume (SV) and cardiac output (Q) in response to the onset and release of -50 torr lower body negative pressure (LBNP) are reported. Six male subjects were sealed into a LBNP box up to the iliac crest while being monitored by echocardiograph for centerlamina blood velocity, fluid displacement, stroke volume, heart rate, and leg volume. Particular use was made of pulsed ultrasonic Doppler velocity meters for measuring the blood velocities and flow dynamics. Measurements were made of the subjects continuously beginning from 20 sec prior to and one min after LBNP onset and release. A linear fall in the SV was observed with LBNP at 49% of the baseline value after 33 sec. A 62% drop, the lowest, was detected after 8 min of LBNP. The leg volume was inversely related to Q for the duration of the experiment.

Loeppky, J. A.↗

FLEET and PLIF Velocimetry Within A Mach 10 Hypersonic Air Flow

Femtosecond laser electronic excitation tagging (FLEET) and planar laser-induced fluorescence (PLIF) velocity measurements utilizing molecular tagging velocity (MTV) methods from three recent test campaigns conducted at the 31-in Mach 10 Air Tunnel at the NASA Langley Research Center are highlighted within. The FLEET measurements reported here include the first direct measurement of freestream velocity at this hypersonic wind tunnel facility. Measurement challenges were exasperated by the low gas density of the Mach 10 air freestream (~0.4% of standard temperature and pressure conditions) and even lower gas densities within the hypersonic wake of a 70-degree sphere-cone model. In addition, the hypersonic freestream and very low speed velocities in the wake also tested the measurement dynamic range. To complement the FLEET measurements in the wake of the sphere-cone model, PLIF velocimetry using seeded nitric oxide was also performed. While NO-PLIF velocimetry has been performed at this facility several times by previous researchers, the use of a 1D diffractive optical element for NO-PLIF velocimetry is reported here for the first time. The 1D DOE enabled the generation of up to 75 laser lines simultaneously and improved the spatial extent of the measurement three times compared to previous work. This enabled a wide velocity measurement plane of approximately 130 mm x 130 mm. The velocimetry methods demonstrated here are expected to improve wind tunnel characterization, provide critical data to validate CFD codes, and improve the design of flight vehicles for planetary entry.

FLEET↗

FLEET and PLIF Velocimetry Within A Mach 10 Hypersonic Air Flow

Femtosecond laser electronic excitation tagging (FLEET) and planar laser-induced fluorescence (PLIF) velocity measurements utilizing molecular tagging velocity (MTV) methods from three recent test campaigns conducted at the 31-in Mach 10 Air Tunnel at the NASA Langley Research Center are highlighted within. The FLEET measurements reported here include the first direct measurement of freestream velocity at this hypersonic wind tunnel facility. Measurement challenges were exasperated by the low gas density of the Mach 10 air freestream (~0.4% of standard temperature and pressure conditions) and even lower gas densities within the hypersonic wake of a 70-degree sphere-cone model. In addition, the hypersonic freestream and very low speed velocities in the wake also tested the measurement dynamic range. To complement the FLEET measurements in the wake of the sphere-cone model, PLIF velocimetry using seeded nitric oxide was also performed. While NO-PLIF velocimetry has been performed at this facility several times by previous researchers, the use of a 1D diffractive optical element for NO-PLIF velocimetry is reported here for the first time. The 1D DOE enabled the generation of up to 75 laser lines simultaneously and improved the spatial extent of the measurement three times compared to previous work. This enabled a wide velocity measurement plane of approximately 130 mm x 130 mm. The velocimetry methods demonstrated here are expected to improve wind tunnel characterization, provide critical data to validate CFD codes, and improve the design of flight vehicles for planetary entry.

FLEET↗

Mechanism continuously measures static and dynamic cable loads

Pulley mechanism measures the tensile loads on a cable under static and dynamic conditions, without disturbing the continuity of operation of the system. A set of takeoff pulleys are mounted on a pivoted frame that is linked to a strain gage which measures the frame displacement as a function of the static or dynamic tensile load on the cable.

Source record↗

Using Satellite Measurements of N2O to Remove Dynamical Variability from HCl Measurements

Column HCl measurements show deviations from the expected slow decline following the regulation of chlorine-containing compounds by the Montreal Protocol. We use the simultaneous measurements of N2O and HCl by the Microwave Limb Sounder (MLS) instrument on the Aura satellite to examine this problem. We find that the use of N2O measurements at a specific altitude to represent the impact of dynamical variability on HCl results in a derived linear trend in HCl that is negative (ranging from -2.5 to 5.3%decade-1) at all altitudes between 68 and 10 hPa. These trends are at or near 2 sigma statistical significance at all pressure levels between 68 and 10 hPa. This shows that analysis of simultaneous measurements of several constituents is a useful approach to identify small trends from data records that are strongly influenced by dynamical interannual variability.

Stolarski, Richard↗

Wall Boundary Layer Measurements for the NASA Langley Transonic Dynamics Tunnel

Measurements of the boundary layer parameters in the NASA Langley Transonic Dynamics tunnel were conducted during extensive calibration activities following the facility conversion from a Freon-12 heavy-gas test medium to R-134a. Boundary-layer rakes were mounted on the wind-tunnel walls, ceiling, and floor. Measurements were made over the range of tunnel operation envelope in both heavy gas and air and without a model in the test section at three tunnel stations. Configuration variables included open and closed east sidewall wall slots, for air and R134a test media, reentry flap settings, and stagnation pressures over the full range of tunnel operation. The boundary layer thickness varied considerably for the six rakes. The thickness for the east wall was considerably larger that the other rakes and was also larger than previously reported. There generally was some reduction in thickness at supersonic Mach numbers, but the effect of stagnation pressure, and test medium were not extensive.

Wieseman, Carol D.↗

Further development of the dynamic gas temperature measurement system

A compensated thermocouple measurement method was experimentally verified. Dynamic signal content from an atmospheric pressure laboratory burner was measured by the dynamic temperature sensor and a relatively delicate fine-wire resistance thermometer. Compensated data from the two dynamic temperature sensor thermoelements were compared with the compensated fine-wire data in the frequency domain. Absolute differences between spectral line amplitudes measured with different sensors are small relative to the mean temperature and verify the compenation method. Increases in precision of the measurement method require optimization of several factors, and directions for further work are identified.

Elmore, D. L.↗

Optimal post-experiment estimation of poorly modeled dynamic systems

Recently, a novel strategy for post-experiment state estimation of discretely-measured dynamic systems has been developed. The method accounts for errors in the system dynamic model equations in a more general and rigorous manner than do filter-smoother algorithms. The dynamic model error terms do not require the usual process noise assumptions of zero-mean, symmetrically distributed random disturbances. Instead, the model error terms require no prior assumptions other than piecewise continuity. The resulting state estimates are more accurate than filters for applications in which the dynamic model error clearly violates the typical process noise assumptions, and the available measurements are sparse and/or noisy. Estimates of the dynamic model error, in addition to the states, are obtained as part of the solution of a two-point boundary value problem, and may be exploited for numerous reasons. In this paper, the basic technique is explained, and several example applications are given. Included among the examples are both state estimation and exploitation of the model error estimates.

Mook, D. Joseph↗

Quasielastic and Inelastic Neutron Scattering Study of Ultraconfined Water in Natural Mordenite ((Ca,Na 2 ,K 2 )Al 2 Si 10 O 24 ·7H 2 O)

Mordenite ((Ca,Na 2 ,K 2 )Al 2 Si 10 O 24 ·7H 2 O) is a natural and synthetic nanoporous zeolite containing several channels of different sizes in its structure. Because of this, its structure provides an important opportunity to study the relationship between confined and ultraconfined water as these channels have sizes between those typical of these water environments. In this study, the properties of water molecules in these environments were analyzed using inelastic and quasielastic neutron spectroscopy of a natural mordenite. The quasielastic spectra showed the presence of nonfreezing, mobile water molecules through the entire temperature range of the measurements, but very little anisotropy of the dynamics measured along and perpendicular to the channels. Faster and slower quasi-elastic neutron scattering (QENS) components may be consistent with the presence of two separate classes of water molecules in mordenite. Inelastic neutron spectroscopy also found no evidence of directional anisotropy. In conclusion, the strong intensity characteristic of neutron recoil on protons from highly mobile water molecules at low temperature (5 K), along with a significant shift of water librational band to lower energies and the O–H stretching modes to high energies, indicate that the hydrogen bonds acting on these water molecules in mordenite resemble those in liquid water rather than ice.

Crystal structure↗

To develop a spectral analyzer for physiological and medical use

Scientific requirements necessary to develop a spectral analyzer for monitoring mammalian subjects, are discussed. The analyzer measures dynamic or time dependent data as a measure of the subjects operating status. Measurable data include metabolic rate, body temperature, and blood constituents like glucose, oxygen, and carbon dioxide, and lactic acid. Metabolic cycles were found with periodicities in the range of minutes and hours; longer cycles in body weight (3 1/2 days and 60 days), indicative of metabolic processes, were also found.

Iberall, A.↗

Flight measurements of the dynamic longitudinal stability of several airplanes and a correlation of the measurements with pilots' observations of handling characteristics

The dynamic longitudinal stability characteristics of eight airplanes as defined by the period and damping of the longitudinal oscillations were measured in flight to determine the degree of stability that may be expected in conventional airplanes. An attempt was made to correlate the measured stability with pilots' opinions of the general handling characteristics of the airplanes in order to obtain an indication of the most desirable degree of dynamic stability. The results of the measurements show that the period of oscillation increases with speed. At low speeds a range of periods from 11 to 23 seconds was recorded for the different airplanes. At high speeds the periods ranged from 23 to 64 seconds. The damping showed no definite trend with speed.

Soule, Hartley A↗

MEASURING THE MASS OF 4UO900-40 DYNAMICALLY

Accurate measurements of neutron star masses are needed to constrain the equation of state of neutron star matter - of importance to both particle physics and the astrophysics of neutron stars - and to identify the evolutionary track of the progenitor stars that form neutron stars. The best measured values of the mass of 4UO900-40 (= Vela XR-l), 1.86 +/- 0.16 Msun (Barziv et al. 2001) and 1.93 +/- 0.20 Msun (Abubekerov et al. 2004), make it a leading candidate for the most massive neutron star known. The direct relationship between the maximum mass of neutron stars and the equation of state of ultra-dense matter makes 4UO900-40 an important neutron star mass to determine accurately. The confidence interval on previous mass estimates, obtained from observations that include parameters determined by non-dynamical methods, are not small enough to significantly restrict possible equations of state. We describe here a purely dynamical method for determining the mass of 4UO900-40, an X-ray pulsar, using the reprocessed UV pulses emitted by its BO.5Ib companion. One can derive the instantaneous radial velocity of each component by simultaneous X-ray and UV observations at the two quadratures of the system. The Doppler shift caused by the primary's rotational velocity and the illumination pattern of the X-rays on the primary, two of the three principal contributors to the uncertainty on the derived mass of the neutron star, almost exactly cancel by symmetry in this method. A heuristic measurement of the mass of 4UO900-40 using observations obtained previously with the High Speed Photometer on HST is given in Appendix A.

Dolan, J. F.↗

Second Target Station Project (CHESS Technical Report)

CHESS is a direct geometry neutron spectrometer designed to detect and analyze weak signals intrinsic to small cross-sections (e.g., small mass, small magnetic moments or neutron absorbing materials). This instrument is optimized to enable unprecedented characterization of quantum materials, spin liquids, thermoelectric and battery materials, liquids, and soft matter. The ability to simultaneously measure dynamic processes over a wide energy range for very small samples will make CHESS the spectrometer of choice for the initial exploration of new materials. The broad dynamic range will also be well matched to measurements of relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of STS enables use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single experiment. An essential feature of CHESS is the capability for polarization analysis to separate nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials, and better understanding spin-anisotropic correlations. This instrument will employ advanced sample environments such as high-pressure cells, dilution refrigerators, high field cryo-magnets and polarization devices, as well as combinations of these, to solve problems at the forefront of materials research. CHESS will be one of the flagship spectrometers of the Second Target Station (STS), providing world leading capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Furthur development of the dynamic gas temperature measurement system

Candidate concepts capable of generating dynamic temperatures were identified and analyzed for use in verifying experimentally the frequency response of the dynamic gas temperature measurement system. A rotating wheel concept and one other concept will be selected for this purpose. Modifications to the data reduction code algorithms developed were identified and evaluated to reduce substantially the data reduction execution time. These modifications will be incorporated in a new data reduction program to be written in FORTRAN IV.

Elmore, D. L.↗

Internal Electrostatic Discharge Monitor - IESDM

A document discusses an innovation designed to effectively monitor dielectric charging in spacecraft components to measure the potential for discharge in order to prevent damage from internal electrostatic discharge (IESD). High-energy electrons penetrate the structural materials and shielding of a spacecraft and then stop inside dielectrics and keep accumulating. Those deposited charges generate an electric field. If the electric field becomes higher than the breakdown threshold (approx. =2 x 10(exp 5) V/cm), discharge occurs. This monitor measures potentials as a function of dielectric depth. Differentiation of potential with respect to the depth yields electric field. Direct measurement of the depth profile of the potential in a dielectric makes real-time electronic field evaluation possible without simulations. The IESDM has been designed to emulate a multi-layer circuit board, to insert very thin metallic layers between the dielectric layers. The conductors serve as diagnostic monitoring locations to measure the deposited electron-charge and the charge dynamics. Measurement of the time-dependent potential of the metal layers provides information on the amount of charge deposited in the dielectrics and the movement of that charge with time (dynamics).

Kim, Wousik↗