Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Advancing Mass Timber Buildings: Novel Methods Improve Thermal Assessment and Material Use

For nearly a century, thermal demand calculations for buildings have relied on simplified models developed to match the technical constraints of their era. The first standards, introduced in Germany and Austria in 1929, established climate zones and material conductivity coefficients that, with only incremental updates, still underpin many current assessments. Yet, methods such as Hot box testing, originally designed for lightweight insulation, continue to be applied for mass timber buildings, overlooking thermodynamic characteristics confer real-world advantages. Recent research at Oak Ridge National Laboratory incorporates updated methodologies, aligned with ASHRAE Standard 55 (ASHRAE, 2023) accounting for factors such as thermal inertia, inner surface temperatures, emissivity, solar gains, and dynamic outdoor conditions. These factors better reflect observed heating and cooling loads and highlight opportunities for efficient use of materials in mass timber construction. This work provides a framework for designing comfortable, resilient, and resource-efficient buildings while aligning with performance expectations in energy codes.

Pickett, Robert [International Mass Timber Allianc↗

OC6 project Phase III: validation of the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure

Abstract. This paper provides a summary of the work done within Phase III of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project, under the International Energy Agency Wind Technology Collaboration Programme Task 30. This phase focused on validating the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure. Numerical models of the Technical University of Denmark 10 MW reference wind turbine were validated using measurement data from a 1:75 scale test performed during the UNsteady Aerodynamics for FLOating Wind (UNAFLOW) project and a follow-on experimental campaign, both performed at the Politecnico di Milano wind tunnel. Validation of the models was performed by comparing the loads for steady (fixed platform) and unsteady (harmonic motion of the platform) wind conditions. For the unsteady wind conditions, the platform was forced to oscillate in the surge and pitch directions under several frequencies and amplitudes. These oscillations result in a wind variation that impacts the rotor loads (e.g., thrust and torque). For the conditions studied in these tests, the system aerodynamic response was almost steady. Only a small hysteresis in airfoil performance undergoing angle of attack variations in attached flow was observed. During the experiments, the rotor speed and blade pitch angle were held constant. However, in real wind turbine operating conditions, the surge and pitch variations would result in rotor speed variations and/or blade pitch actuations, depending on the wind turbine controller region that the system is operating. Additional simulations with these control parameters were conducted to verify the fidelity of different models. Participant results showed, in general, a good agreement with the experimental measurements and the need to account for dynamic inflow when there are changes in the flow conditions due to the rotor speed variations or blade pitch actuations in response to surge and pitch motion. Numerical models not accounting for dynamic inflow effects predicted rotor loads that were 9 % lower in amplitude during rotor speed variations and 18 % higher in amplitude during blade pitch actuations.

17 WIND ENERGY↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗

Balance of Plant Modeling and Real-Time Hardware-in-the-Loop Integration with the Microreactor Automated Control System

The advent of novel microreactor technology has driven a focused effort to explore safety and efficiency improvements that can be achieved through the use of automated system control. Development of control strategies, especially for initial demonstration, requires an adequate surrogate environment to safely research failure modes and control integration with realistic hardware delay. However, efficiency gains from control strategies are improved when the scope of controller action is expanded to include system-level dynamics such as downstream heat extraction and mass flow. For this reason, a balance-of-plant (BOP) model of a representative microreactor system has been developed using the TRANsient Simulation Framework of Reconfigurable Models library in Modelica. This model captures a reactor and primary NaK coolant loop that represent corresponding system components of the Microreactor Applications Research Validation and EvaLuation (MARVEL) design as well as a secondary coolant loop and heat extraction representative of the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET). This model configuration allows for hardware-in-the-loop (HIL) integration with microreactor automated control system (MACS) hardware in real time through a Python-based gRPC client. Real-time simulation of model performance with emulated hardware and communication delay suggests that under independent proportional-integral-derivative control of BOP model drum dynamics and downstream heat extraction, stable power load following is achievable. A slight delay in load following, filtering of high-frequency dynamics, and localized temperature fluctation suggest room for improvement through the development of higher-level control strategies. The simulated coupling of the MAGNET facility lays the groundwork for future digital twin analysis with a coupled MACS-MAGNET HIL demonstration.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

MRT 7365 Power flow physics and key physics phenomena: EMPIRE verification suite

This milestone work baselines electromagnetic particle-in-cell capability of the EMPIRE plasma simulation code to model key processes germane to the physics of electrode plasmas arising in magnetically-insulated transmission lines operating at or near 20 MA. This evaluation is done so through the provision of benchmark verification problems designed to exercise the individual and combined physics models on a small-scale surrogate geometry for the final-feed-to-load region of the Z accelerator under representative operating conditions. In this report, we overview our test designs, and present a portfolio of simulation results along with performance assessments which altogether establish state-of-the-art. In particular, two main verification categories are covered this report: (1) Z-relevant desorption physics (Temkin isotherm), and (2) two approaches to simulate electrode plasma creation and dynamics (automatic creation versus self-consistent creation through direct simulation Monte Carlo collisions).

43 PARTICLE ACCELERATORS↗

Heavy-Duty Nonroad Material Handler Electrification Part 2: Energy Efficiency and Performance Evaluation

Decarbonization efforts achieved through electrification in nonroad mobile machinery can realize a reduction in fuel consumption of more than 20%, thanks to concepts familiar to light-duty passenger vehicles. This case study compares the results of a hybrid-electric material handler to its conventional counterpart, utilizing machine-specific drive cycles presented in part one of this paper series. The hybrid prototype features an extended-range electric vehicle (EREV) powertrain that demonstrated substantial energy efficiency improvements. Specifically, there was a reduction in equivalent fuel consumption of 75% when operating in electric-only mode, and 33% when maintaining the battery by charging with an on-board generator. Together, the efficiency improvements can be extrapolated over a low-intensity, 8-h shift characterized by significant idle time and highly dynamic engine load for a 47% reduction in net energy consumption. Key technologies that led to this improvement included engine downsizing and decoupling, regenerative braking, and an electrohydraulic pump unit with advanced controls. Finally, his study explains details of the powertrain architecture and subsystems that were implemented on a demonstration vehicle, control strategies used to meet project goals, and an analysis of energy consumption from testing on a closed course. Also included in this study is a discourse on comparison metrics that can be used for quantifying the energy consumption differences between hybrid-electric and conventional diesel powertrains in nonroad mobile machinery.

25 ENERGY STORAGE↗

Determining the Solubility Behavior of Kogarkoite in Simulated Nuclear Waste

Kogarkoite (Na 3 FSO 4 ) is a sparingly soluble fluoride–sulfate double salt that has been identified in high level nuclear waste sludge at the Hanford Site and, more recently, in sludge batch compilation samples at the Savannah River Site (SRS). Due to its complex dissolution behavior, which exhibits an inverse dependence on sodium ion activity, the presence of this mineral poses significant challenges to waste retrieval and processing. Incomplete dissolution during sludge washing can lead to the retention of fluoride and sulfate in the high-level waste feed, potentially causing the formation of corrosive, immiscible molten salt layers, known as "glass gall,” in vitrification melters. Current efforts to optimize flowsheet parameters and wash-water volumes are hindered by the absence of a commercially available, certified reference material, which prevents the accurate calibration of analytical methods and the verification of dissolution kinetics. To address this critical gap, this research focuses on the laboratory synthesis of pure Kogarkoite to serve as a standard for comprehensive solubility and washing performance testing. A coupled synthesis and simulant campaign was executed using an evaporative crystallization protocol designed to replicate the dynamic concentration effects observed in tank farm operations. Thirteen simulant matrices were prepared by dissolving systematically varied ratios of sodium fluoride (NaF) and sodium sulfate (Na 2 SO 4 ) in deionized water under three distinct caustic regimes: 0.0 g (control), 4.0 g (~1 M), and 12.0 g (~3 M) sodium hydroxide (NaOH). While thermodynamic equilibrium models suggest that high-caustic environments should favor the stability of the double salt7, results from this evaporative study at 25 0 C revealed a distinct kinetic divergence. Simulants with high hydroxide loading predominantly yielded large, blocky crystals of sodium sulfate decahydrate (Na 2 SO 4 .10H 2 O). Successful synthesis of pure Kogarkoite was achieved exclusively in specific NaOH-free compositional windows, where the precipitate manifested as fine, opaque granular aggregates. Ion chromatography (IC) analysis confirmed phase purity through the simultaneous stoichiometric depletion of both fluoride and sulfate from the supernatant. This successful synthesis establishes a reproducible route to generate bulk Kogarkoite, enabling the subsequent phase of quantitative dissolution testing using inhibited water to optimize sludge-batch assembly.

Sarker, Md Sharif [Florida International Univ. (FI↗

Thermal Analysis Evaluations Using the Dry Cask Simulator

Different thermal analysis models were developed to simulate the dry cask simulator (DCS). The DCS is an experiment designed to simulate dry storage of a single boiling water reactor fuel assembly under a variety of heat loads and internal pressures. The DCS was set up and tested in both a vertical and horizontal configuration to determine cladding temperatures in vertical and horizontal dry cask storage systems. The models included a detailed STAR-CCM+ model with the fuel assembly geometry explicitly modeled, a porous STAR-CCM+ model with the fuel assembly geometry modeled as porous media region with calculated effective properties, and a COBRA-SFS model. COBRA-SFS is a thermal-hydraulic code developed for steady-state and transient analysis of multi assembly spent-fuel storage and transportation systems. STAR-CCM+ is a commercial computation fluid dynamics (CFD) code. Both a detailed and porous STARCCM+ model were developed to look at the effective thermal conductivity (keff) approach to modeling a fuel assembly. A keff fuel model is typically model in CFD thermal analyses due to its significantly lower computational costs. The models were run for a combination of low and high canister pressures (100 kPa and 800 kPa) and low and high internal heat loads (0.5 kW and 5 kW). Results from all three models were compared against experimental data taken from the DCS for the peak cladding temperature (PCT) and inlet air mass flow.

Suffield, Sarah R.↗

Effect of Fatigue on the Capacity and Performance of Structural Concrete

The goal of this project was to enhance the understanding of the fatigue behavior of concrete structures for the purpose of improving the design and assessment of towers and foundations that support wind turbines, which must endure repeated loadings from wind, waves, operations, and other dynamic effects that cause material degradation. This was achieved through physical experiments, a review of the technical literature, and collaboration with experts in key subject areas. The project produced a comprehensive database of publicly available fatigue data, several technical papers presenting the research findings, and two Technotes to be published by the American Concrete Institute that advance best practices in fatigue testing and enable the development of concrete-specific fatigue (S-N) (stress-life) curves. These contributions are expected to enhance the durability and cost-effectiveness of wind turbine support structures.

17 WIND ENERGY↗

Compressive strength of the plastic-bonded explosive surrogate idoxuridine under quasistatic and dynamic compression

Inert simulant materials, or “mocks”, are often used as surrogates for plastic-bonded explosives (PBX) in non-detonative tests in order to mitigate hazards. Mocks should reproduce as many non-detonative properties of the explosive as possible, including structural behavior in a variety of thermal and mechanical environments. Recently, the molecular crystal idoxuridine (IDOX) has been identified as an ideal mock for the main component in the explosive polymer-matrix composite PBX 9501, and has performed favorably under quasistatic loading conditions. Here, in order to assess robustness over a range of mechanical environments, plastic-bonded IDOX was compression tested from 0.001/s to 2000/s strain rates and compared to PBX 9501 historical data. Plastic-bonded IDOX showed good agreement to PBX 9501 across these strain rates, justifying continued development and production as a mock.

Burch, Alexandra C.↗

Informing the planning of rotating power outages in heat waves through data analytics of connected smart thermostats for residential buildings

Abstract With climate change, heat waves have become more frequent and intense. Rotating power outages happen when the power supply is unable to meet the cooling demand increase resulting from extreme high temperatures. Power outages during heat waves expose residents to high risks of overheating. In this study, we propose a novel data-driven inverse modelling approach to inform decision makers and grid operators on planning rotating power outages. We first infer the building thermal characteristics using the connected smart thermostat data, and used the estimated thermal dynamics to simulate the thermal resilience during a heat wave event. Our proposed method was tested for the California power outage in August 2020 by using the open source Ecobee Donate Your Data dataset. We found in California the power outage should not last more than two hours during heat waves to avoid overheating risks. Informing the residents in advance so they can prepare for it through pre-cooling is a simple but effective strategy to expand the acceptable power outage duration. In addition to assisting power outage planning, the proposed method can be used for other applications, such as to evaluate a building energy efficiency policy, to examine fuel poverty, and to estimate the load shifting potential of building stocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Scientific/Technical Report-FREE-piston Zero Emissions Refrigerator (FREEZER)

The FREE-piston Zero Emissions Refrigerator (FREEZER™) is a natural refrigerant Stirling-cycle cooler developed by AMSC in partnership with Heatcraft, targeted as a replacement refrigeration system for walk-in coolers or freezers found commonly in restaurants, convenience stores, supermarkets, etc. The FREEZER™, combined with a closed-loop CO2 heat-transfer system, had the goal to provides an efficient (Target COP = 1.4), zero ODP (Ozone Depletion Potential) and near zero GWP (Global Warming Potential) refrigeration solution with no synthetic, flammable, or toxic refrigerants. Other near zero GWP refrigeration systems do not exist at the scale and performance level of FREEZER. ARPA-E Continuation Funding enabled the design and fabrication of one Advanced Development Unit (ADU) cooler and two Field Test Unit (FTU) coolers, and a new revised Field Test Unit (new FTU). Heatcraft was to extensively test the various coolers at their facilities, which closely simulate real-world conditions. The original plan was to install and operate FREEZER FTUs alongside a traditional cooling solution at one or more customer locations to obtain data on direct performance comparisons with existing commercial refrigeration systems. Success in this FREEZER refinement and field-test project will establish the basis for a new class of environmentally friendly refrigeration systems that will revolutionize the industry. The hardware developed under the program is shown below in Figure 1. Five Stirling-cycle machines were built within the program, with a sixth cooler still under construction. The original DU and the ADU coolers met the performance target with a coefficient of performance (COP) of 1.2. The FTU was underperforming during the initial tuning of the free-piston Stirling cycle dynamics when there was a catastrophic failure of the fasteners on pressure boundary. This caused a pause to the program while the failure mechanism was investigated. The root cause was an inadequate flange design that allowed an excessive cyclic loading on the fasteners, leading to a fatigue failure. It was determined that existing FTU design could not be reasonably salvaged in a safe manner, and that fact, combined with the lower-than-expected performance of the new experimental heat exchanger modules lead to the design of the “new FTU” with a more conventional shell-and-tube heat exchanger design which should get close to the design target COP of 1.4, but have a higher overall machine cost. The program ran out of time before the fabrication of the new FTU was completed, but AMSC is still working on the cooler, with the majority of the parts fabricated, and hopes to have the unit under test sometime in early 2022, after which it will be shipped to Heatcraft for additional testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High strain rate nanoindentation testing: Recent advancements, challenges and opportunities

Recent advancements in electronics have renewed the interest in high strain rate nanoindentation testing, resulting in the development of new high strain rate nanoindentation test equipment and test methodologies. Here, in this work, the current state-of-the-art in high strain rate nanoindentation testing is critically reviewed, with focus on three key aspects - the testing equipment's dynamic mechanical and electronic response, test methodology, and post-processing of raw data to obtain hardness and strain rate. The challenges in instrument hardware design and post-test data analysis are discussed, along with optimal strain rate window for accurate high strain rate measurements. Specific focus will be on instrumented high strain rate testing using self-similar indenters at strain rates in excess of 100 s -1 , wherein load and depth of penetration into the sample are both measured or applied.

36 MATERIALS SCIENCE↗

Effects of a CFD-improved dimple stepped-lip piston on thermal efficiency and emissions in a medium-duty diesel engine

Diesel piston-bowl shape is a key design parameter that affects spray-wall interactions and turbulent flow development, and in turn affects the engine’s thermal efficiency and emissions. It is hypothesized that thermal efficiency can be improved by enhancing squish-region vortices as they are hypothesized to promote fuel-air mixing, leading to faster heat-release rates. However, the strength and longevity of these vortices decrease with advanced injection timings for typical stepped-lip (SL) piston geometries. Dimple stepped-lip (DSL) pistons enhance vortex formation at early injection timings. Previous engine experiments with such a bowl show 1.4% thermal efficiency gains over an SL piston. However, soot was increased dramatically [SAE 2022-01-0400]. In a previous study, a new DSL bowl was designed using non-combusting computational fluid dynamic simulations. This improved DSL bowl is predicted to promote stronger, more rotationally energetic vortices than the baseline DSL piston: it employs shallower, narrower, and steeper-curved dimples that are placed further out into the squish region. In the current experimental study, this improved bowl is tested in a medium-duty diesel engine and compared against the SL piston over an injection timing sweep at low-load and part-load operating conditions. No substantial thermal efficiency gains are achieved at the early injection timing with the improved DSL design, but soot emissions are lowered by 45% relative to the production SL piston, likely due to improved air utilization and soot oxidation. However, these benefits are lost at late injection timings, where the DSL piston renders a lower thermal efficiency than that of the SL piston. Energy balance analyses show higher wall heat transfer with the DSL piston than with the SL piston despite a 1.3% reduction in the piston surface area. Vortex enhancement may not necessarily lead to improved efficiency as more energetic squish-region vortices can lead to higher convective heat transfer losses.

42 ENGINEERING↗

Prime Time for Model-Predictive Control? Assessing the Technical and Market Readiness of Advanced Controls in Buildings

Despite three decades of extensive research and field testing that have consistently validated the benefits of Model Predictive Control (MPC) in building applications, the technology has seen limited market adoption. This paper evaluates the readiness of MPC for widespread deployment, showcases recent demonstrations and field tests across diverse building types, including residential, small commercial, large commercial, and campus settings. Our results demonstrate that MPC can optimize system operations to achieve load shifting, minimize curtailment of on-site generation, and reduce energy costs by up to 80 %, while maintaining or improving occupant comfort. We also show that MPC can effectively control large assets, such as MW-sized thermal storage systems, and respond to dynamic pricing signals. However, achieving scale remains difficult due to labor-intensive workflows, reliance on a “PhD-in-the-loop” for MPC design and maintenance, susceptibility to fragile data infrastructure, and persistent workforce education and acceptance barriers. To bridge this gap, we outline a transition from bespoke, labor intensive prototypes toward streamlined, segment-targeted deployment strategies that leverage model templates, semantic tools, and generative AI. By automating control configuration and reducing engineering effort, these recommendations provide a pathway for transforming successful research demonstrations into scalable, market ready solutions for MPC-based controls.

Pritoni, Marco↗

Crashworthiness of recycled carbon fiber composite sinusoidal structures at dynamic rates

Fiber reinforced polymer composites are finding applications in the automotive space for structurally critical applications including crash management. The use of recycled carbon fiber reinforcement can greatly reduce carbon emissions. In this study, recycled carbon fiber composites were manufactured into a self-supporting geometry using three matrices: polyphenylene sulfide (PPS), acrylonitrile butadiene styrene (ABS), and a structural epoxy, and subsequently crushed between flat platens at dynamic rates ranging from 4.6 to 9.1 ms -1 at temperatures in a range of -40°C to 80°C. Load-displacement data was used to evaluate their specific energy absorption, crush efficiency, and steady-state crush stress. Further, the energy absorption of the ABS composites was strongly sensitive to temperature, while the PPS composites exhibited strong crush efficiency dependence with both rate and temperature. The epoxy composites exhibited stable crush behavior at dynamic crush rates but exhibited a dramatic reduction in crush efficiency relative to quasi-static tests. The results of this study indicate that recycled fiber composites can achieve very high energy absorption levels (50–80kJkg -1 at room temperature) that make them an excellent alternative to more expensive and less environmentally friendly continuous virgin fiber laminates.

42 ENGINEERING↗

The high explosives & affected targets (HEAT) dataset

Artificial Intelligence (AI) surrogate models offer a computationally efficient alternative to full-physics simulations, yet no existing datasets are publicly available for training, testing, and validation of machine learning models of the dynamics of high-explosive driven shocks through multiple materials. Shock propagation through materials is a computationally challenging problem because simulations must include material-specific equations of state (EOS) along with descriptions of other physical processes such as plastic deformation, phase change, damage processes, fluid instabilities, and multi-material interactions. Shocks are typically initiated by high-velocity impacts or explosive loading. The latter case necessitates the addition of models of reactive materials to represent high-explosive (HE) detonation. Here, to address the lack of an expansive dataset for multi-material shock propagation in the AI/ML community, we present the High-Explosives and Affected Targets (HEAT) Dataset. HEAT is a physics-rich collection of two-dimensional, cylindrically symmetric, simulations generated using an Eulerian, multi-material, shock-propagation code developed at Los Alamos National Laboratory. The dataset includes two partitions: (1) the expanding shock-cylinder (CYL) simulations, Figs. 1, and (2) the Perturbed Layered Interface (PLI) simulations, Fig. 2. Entries in both partitions consist of time series of arrays of thermodynamic fields (pressure, density, and temperature), kinematic fields (position and velocity), and additional fields that depend on thermodynamic and/or kinematic fields (e.g., material stress). Materials in the CYL partition include solids (aluminium, copper, depleted uranium, stainless steel, tantalum, and a generic polymer), a liquid (water), gases (air, nitrogen), and a generic detonating material (high explosive, HE). The PLI partition spans a highly varying geometry but consists of fixed materials across entries: Copper, aluminium, stainless steel, generic polymer, and generic HE. HEAT captures critical phenomena such as momentum transfer, shock propagation, plastic deformation, and thermal effects, making HEAT a valuable benchmark for development of AI/ML emulation of multi-material shock propagation.

36 MATERIALS SCIENCE↗

A Simulation and Optimization Framework for Managing Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability as measured by both acceleration and deformation, focusing on the stability differences between positive and negative tilt angles.

fluid structure interaction↗