Effect of type of load on stress analysis of thin-walled ducts

The standard procedure for qualifying the design of duct (pipe) systems in the Space Shuttle Main Engine (SSME) has been fairly well defined. However, since pipe elbows are quite common and important in the SSME duct systems, a clear understanding of the detailed stress profile of the components is necessary for accurate structural and life assessments. This study was initiated to predict the stress profile at/near the tangent point along the cross section of the duct under various types of loads. Also, this study was further extended to understand the stiffening effect on stresses due to pressure at the tangent point. The intention of this study was to identify the importance of selecting proper locations for mounting strain gauges and to utilize the obtained results to anchor dynamic models for accurate structural and life assessments of the SSME ducts under a dynamic environment. The finite element method was utilized in this study.

Min, J. B.↗

A computational study of advanced exhaust system transition ducts with experimental validation

The current study is an application of CFD to a 'real' design and analysis environment. A subsonic, three-dimensional parabolized Navier-Stokes (PNS) code is used to construct stall margin design charts for optimum-length advanced exhaust systems' circular-to-rectangular transition ducts. Computer code validation has been conducted to examine the capability of wall static pressure predictions. The comparison of measured and computed wall static pressures indicates a reasonable accuracy of the PNS computer code results. Computations have also been conducted on 15 transition ducts, three area ratios, and five aspect ratios. The three area ratios investigated are constant area ratio of unity, moderate contracting area ratio of 0.8, and highly contracting area ratio of 0.5. The degree of mean flow acceleration is identified as a dominant parameter in establishing the minimum duct length requirement. The effect of increasing aspect ratio in the minimum length transition duct is to increase the length requirement, as well as to increase the mass-averaged total pressure losses. The design guidelines constructed from this investigation may aid in the design and manufacture of advanced exhaust systems for modern fighter aircraft.

Wu, C.↗

Navier-Stokes analysis of three-dimensional S-ducts

Full 3D Navier-Stokes computational results are presented for compressible flows within nondiffusing and diffusing S-ducts. The present study provides an understanding of the performance characteristics of typical S-ducts with attached and separated flows and provides a frame of reference for future computational fluid dynamic studies of internal flows with strong secondary flows. The predicted results, which were obtained using both H- and O-grids, are compared with the experimental wall pressures, static and total pressure fields, and velocity vectors. In addition, computed boundary-layer thickness, velocity profiles in wall coordinates and skin friction values are presented. The inviscid contributions to the secondary flows are quantified. The S-duct entrance Mach number was 0.6, and the Reynolds number was 1.76 x 10 exp 6 based on the upstream duct diameter.

Harloff, G. J.↗

Experimental and numerical investigation of supersonic turbulent flow in an annular duct

Experimental and numerical results are presented for developing supersonic turbulent flow in an annular duct formed by a circular centerbody and outer shroud. The experimental results are based on data taken in a new flow facility that was designed to generate a shock-free, supersonic annular flow. Numerical computations were performed using the Baldwin-Lomax turbulence model for comparison with experimentally measured profiles. The results demonstrate that computed and measured profiles are in excellent agreement, so that studies can now be conducted of shock wave/boundary layer interaction phenomena within the duct, such as those induced by changes in downstream duct geometry or by the placement of struts between the duct walls.

Williams, K. E.↗

Numerical simulation of a shock wave/turbulent boundary layer interaction in a duct

A numerical investigation of the interaction of an incident oblique shock wave with a turbulent duct flow is presented. The investigation consists of solving the three-dimensional, unsteady, compressible, mass averaged Navier-Stokes equations, using an implicit finite volume, lower-upper time marching code and incorporates the three-dimensional Baldwin-Lomax turbulence model. Computed results are obtained Mach number 2.9 for a turning angle of 13 degrees and Reynolds number based on duct width of 1.36 x 10 exp 7. Under various inlet conditions, the results clearly depict the flow characteristics, including the shock geometry, the separated flow region, the wall pressure distribution, and the skin friction distribution. The findings provide a physical understanding of the three-dimensional vortex structure of the flow in a duct in which a shock wave interacts with a turbulent boundary layer. The results show that the ratio of the boundary layer thickness to the duct width is the critical parameter in determining the separation structure.

Yang, Wei-Li↗

Cooling Tests of an Airplane Equipped with an NACA Cowling and a Wing-duct Cooling System

Cooling tests were made of a Northrop A-17A attack airplane successively equipped with a conventional.NACA cowling and with a wing-duct cooling system. The method of cooling the engine by admitting air from the propeller slipstream into wing ducts, passing it first through the accessory compartment and then over the engine from rear to front, appeared to offer possibilities for improved engine cooling, increased cooling of the accessories, and better fairing of the power-plant installation. The results showed that ground cooling for the wing duct system without cowl flap was better than for the NACA cowling with flap; ground cooling was appreciably improved by installing a cowl flap. Satisfactory temperatures were maintained in both climb and high-speed flight, but, with the use of conventional baffles, a greater quantity of cooling air appeared to be required for the wing duct system.

Turner, L I , Jr↗

Experimental investigations on freely exposed ducted radiators

This report deals with the relation between the open areas, the drag, and the air flow as observed on freely exposed, ducted radiators - the air conductivity being modified from zero to one unit. In conjunction with theoretical results, the individual components of the drag of ducted radiators are discussed and general rules established for low-loss ducts. The influence of the wall thickness of the ducts, of the length ratio of the exit, and the effects of sonic velocity on diffusers are dealt with by special measurement.

Linke, W↗

Mixing characteristics of directly opposed rows of jets injected normal to a crossflow in a rectangular duct

An experimental investigation of the mixing of nonreacting opposed rows of inline jets injected perpendicular to a uniform crossflow has been conducted in a rectangular duct. Planar Mie-scattering was used to measure the time-average concentration distribution of the jet fluid in planes perpendicular to the duct axis. Orifice configurations with geometric blockages ranging from 0.59 to 0.89 had similar mixing performance when compared at one-half duct height downstream of injection. Blockage was varied by changing the orifice aspect ratio from 1-to-1 to 1-to-1.5 while maintaining orifice spacing-to-duct height (S/H) at 0.425, jet-to-mainstream mass flow ratio (MR) at 2.0, and jet-to-mainstream momentum-flux ratio (J) at 48. The result indicates that the design correlating expression (at MR = 2) for optimum in line mixing of 2.5 approximately equal to (S/H)(square root of J) is independent of the Webb between adjacent orifices and therefore independent of orifice width. Experimental and numerical results for an orifice aspect ratio 1-to-1 case were in good agreement. The results of a comparison of inline 45 degrees slanted slot and round orifice configuration indicate that in order to obtain equivalent mean concentration distributions at the same J it is necessary to use a smaller S/H for the round orifice configuration. Conclusions about the performance of various orifice shapes can only be obtained from comparison of optimized configurations. Inline jets with different momentum-flux ratios on opposite sides were compared at a constant mass flow ratio. The orifice spacing chosen was previously found to be an optimum configuration when opposing values of J were equal and also an optimum for single side injection. Experimental and empirical results were in good agreement.

Liscinsky, D. S.↗

Periodic Time-Domain Nonlocal Nonreflecting Boundary Conditions for Duct Acoustics

Periodic time-domain boundary conditions are formulated for direct numerical simulation of acoustic waves in ducts without flow. Well-developed frequency-domain boundary conditions are transformed into the time domain. The formulation is presented here in one space dimension and time; however, this formulation has an advantage in that its extension to variable-area, higher dimensional, and acoustically treated ducts is rigorous and straightforward. The boundary condition simulates a nonreflecting wave field in an infinite uniform duct and is implemented by impulse-response operators that are applied at the boundary of the computational domain. These operators are generated by convolution integrals of the corresponding frequency-domain operators. The acoustic solution is obtained by advancing the Euler equations to a periodic state with the MacCormack scheme. The MacCormack scheme utilizes the boundary condition to limit the computational space and preserve the radiation boundary condition. The success of the boundary condition is attributed to the fact that it is nonreflecting to periodic acoustic waves. In addition, transient waves can pass rapidly out of the solution domain. The boundary condition is tested for a pure tone and a multitone source in a linear setting. The effects of various initial conditions are assessed. Computational solutions with the boundary condition are consistent with the known solutions for nonreflecting wave fields in an infinite uniform duct.

Watson, Willie R.↗

The Effects of Acoustic Treatment on Pressure Disturbances From a Supersonic Jet in a Circular Duct

The pressure disturbances generated by an instability wave in the shear layer of a supersonic jet are studied for an axisymmetric jet inside a lined circular duct. For the supersonic jet, locally linear stability analysis with duct wall boundary conditions is used to calculate the eigenvalues and the eigenfunctions at each axial location. These values are used to determine the growth rates and phase velocities of the instability waves and the near field pressure disturbance patterns. The study is confined to the dominant Kelvin-Helmholtz instability mode and to the region just downstream of the nozzle exit where the shear layer is growing but is still small in size compared to the radius of the duct. Numerical results are used to study the effects of changes in the outer flow, growth in the shear layer thickness, wall distance, and wall impedance, and the effects of these changes on non-axisymmetric modes. The primary results indicate that the effects of the duct wall on stability characteristics diminish as the outer flow increases and as the jet azimuthal mode number increases. Also, wall reflections are reduced when using a finite impedance boundary condition at the wall; but in addition, reflections are reduced and growth rates diminished by keeping the imaginary part of the impedance negative when using the negative exponential for the harmonic dependence.

Dahl, Milo D.↗

Effects of Acoustically Lined Cylindrical Ducts on Instability Waves in Confined Supersonic Jets

The pressure disturbances generated by an instability wave in the shear layer of a supersonic jet are studied for an axisymmetric jet inside a lined cylindrical duct. For the supersonic jet, locally linear stability analysis with duct wall boundary conditions is used to calculate the eigenvalues and the eigenfunctions. These values are used to determine the growth rates and phase velocities of the instability waves and the radial pressure disturbance patterns. The study is confined to the dominant Kelvin-Helmholtz instability mode and to the region just downstream of the nozzle exit where the shear layer is growing but is still small in size compared to the radius of the duct. Numerical results are used to study the effects of changes in the outer flow, growth in the shear layer thickness, wall distance, wall impedance, and frequency. Results indicate that the effects of the duct wall on shear layer growth rates diminish as the outer flow increases. Also, wall reflections cause variations in growth rates depending on wall height and Strouhal number. These variations are due to the phase relationship between the outgoing and the reflected incoming pressure disturbances at the shear layer. The growth rate variations can be reduced and the maximum growth rate minimized by keeping the imaginary part of the impedance negative.

Dahl, Milo D.↗

Radiation of Sound From a Point Source in a Short Duct

It is the purpose of this paper to provide, in relatively brief form, a summary of a boundary integral approach that has been developed for calculating the sound field radiated from short ducts in uniform axial motion. The method was devised primarily to study sound generated by rotating sources in the duct, as is of current practical interest in connection with ducted-fan aircraft engines. Detailed background on the fan source application of the technique can be found. The author has not previously discussed the simpler monopole source case of interest in these proceedings. However, readers desiring a more detailed treatment than will be included here should have little difficulty in extracting it from those references after making the relatively minor modifications necessary to adapt the analyses to the monopole case. It should be noted that other authors have also considered radiation from short ducts. In particular, readers may find the finite-element approach of Eversman of interest as well as the alternate boundary integral method treatments of Martinez and of Dunn, Tweed, and Farassat.

Myers, M. K.↗

TBIEM3D: A Computer Program for Predicting Ducted Fan Engine Noise

This document describes the usage of the ducted fan noise prediction program TBIEM3D (Thin duct - Boundary Integral Equation Method - 3 Dimensional). A scattering approach is adopted in which the acoustic pressure field is split into known incident and unknown scattered parts. The scattering of fan-generated noise by a finite length circular cylinder in a uniform flow field is considered. The fan noise is modeled by a collection of spinning point thrust dipoles. The program, based on a Boundary Integral Equation Method (BIEM), calculates circumferential modal coefficients of the acoustic pressure at user-specified field locations. The duct interior can be of the hard wall type or lined. The duct liner is axisymmetric, locally reactive, and can be uniform or axially segmented. TBIEM3D is written in the FORTRAN programming language. Input to TBIEM3D is minimal and consists of geometric and kinematic parameters. Discretization and numerical parameters are determined automatically by the code. Several examples are presented to demonstrate TBIEM3D capabilities.

Dunn, M. H.↗

Euler/Navier-Stokes Solvers Applied to Ducted Fan Configurations

Due to noise considerations, ultra high bypass ducted fans have become a more viable design. These ducted fans typically consist of a rotor stage containing a wide chord fan and a stator stage. One of the concerns for this design is the classical flutter that keeps occurring in various unducted fan blade designs. These flutter are catastrophic and are to be avoided in the flight envelope of the engine. Some numerical investigations by Williams, Cho and Dalton, have suggested that a duct around a propeller makes it more unstable. This needs to be further investigated. In order to design an engine to safely perform a set of desired tasks, accurate information of the stresses on the blade during the entire cycle of blade motion is required. This requirement in turn demands that accurate knowledge of steady and unsteady blade loading be available. Aerodynamic solvers based on unsteady three-dimensional analysis will provide accurate and fast solutions and are best suited for aeroelastic analysis. The Euler solvers capture significant physics of the flowfield and are reasonably fast. An aerodynamic solver Ref. based on Euler equations had been developed under a separate grant from NASA Lewis in the past. Under the current grant, this solver has been modified to calculate the aeroelastic characteristics of unducted and ducted rotors. Even though, the aeroelastic solver based on three-dimensional Euler equations is computationally efficient, it is still very expensive to investigate the effects of multiple stages on the aeroelastic characteristics. In order to investigate the effects of multiple stages, a two-dimensional multi stage aeroelastic solver was also developed under this task, in collaboration with Dr. T. S. R. Reddy of the University of Toledo. Both of these solvers were applied to several test cases and validated against experimental data, where available.

Keith, Theo G., Jr.↗

The Reduction of Ducted Fan Engine Noise Via A Boundary Integral Equation Method

The development of a Boundary Integral Equation Method (BIEM) for the prediction of ducted fan engine noise is discussed. The method is motivated by the need for an efficient and versatile computational tool to assist in parametric noise reduction studies. In this research, the work in reference 1 was extended to include passive noise control treatment on the duct interior. The BEM considers the scattering of incident sound generated by spinning point thrust dipoles in a uniform flow field by a thin cylindrical duct. The acoustic field is written as a superposition of spinning modes. Modal coefficients of acoustic pressure are calculated term by term. The BEM theoretical framework is based on Helmholtz potential theory. A boundary value problem is converted to a boundary integral equation formulation with unknown single and double layer densities on the duct wall. After solving for the unknown densities, the acoustic field is easily calculated. The main feature of the BIEM is the ability to compute any portion of the sound field without the need to compute the entire field. Other noise prediction methods such as CFD and Finite Element methods lack this property. Additional BIEM attributes include versatility, ease of use, rapid noise predictions, coupling of propagation and radiation both forward and aft, implementable on midrange personal computers, and valid over a wide range of frequencies.

Tweed, J.↗

A Flight Study of the Conversion Maneuver of a Tilt-Duct VTOL Aircraft

Flight records are presented from an early flight test of a wing-tip mounted tilting-ducted-fan, vertical-take-off and landing (VTOL) aircraft configuration. Time histories of the aircraft motions, control positions, and duct pitching-moment variation are presented to illustrate the characteristics of the aircraft in hovering, in conversion from hovering to forward flight, and in conversion from forward flight to hovering. The results indicate that during essentially continuous slow level- flight conversions, this aircraft experiences excessive longitudinal trim changes. Studies have shown that the large trim changes are caused primarily by the variation of aerodynamic moments acting on the duct units. Action of the duct-induced downwash on the horizontal stabilizer during the conversion also contributes to the longitudinal trim variations. Time histories of hovering and slow vertical descent in the final stages of landing in calm air show angular motions of the aircraft as great as +/- 10 deg. about all axes. Stick and pedal displacements required to control the aircraft during the landing maneuver were on the order of 50 to 60 percent of the total travel available.

Tapscott, Robert J.↗

Stability and Control Characteristics of a Model of an Aerial Vehicle Supported by Four Ducted Fans

The stability and control characteristics of a simple, lightly loaded model approximately one-third the size of a full-scale vehicle have been investigated by a series of free-flight tests. The model is representative of a type of vertically rising aircraft which would utilize four ducted fans as its sole source of lift and propulsion. The ducts were arranged in a rectangular pattern and were fixed to the airframe so that their axes of revolution were vertical for hovering flight. Control moments were provided by remotely controlled compressed-air jets at the sides and ends of the model. In hovering, the model in its original configuration exhibited divergent oscillations about both the roll and pitch axes. Because these oscillations were of a rather short period., the model was very difficult to control by the use of remote controls only. The model could be completely stabilized by the addition of a sufficient amount of artificial damping. The pitching oscillation was made easier to control by increasing the distance between the forward and rearward pairs of ducts. In forward flight, with the model in its original configuration, the top speed was limited by the development of an uncontrollable pitch-up. Large forward tilt angles were required for trim at the highest speeds attained. With the model rotated so that the shorter axis became the longitudinal axis, the pitch trim problem was found to be less than with the longer axis as the longitudinal axis. The installation of a system of vanes in the slipstream of the forward ducts reduced the tilt angle but increased the power required.

Parlett, Lysle P.↗

Stability and Control Characteristics of a Small-Scale Model of an Aerial Vehicle Supported by Two Ducted Fans

An investigation has been made to determine the stability and control characteristics in hovering and in forward flight of a free-flight model representing a type of vertical-take-off-and-landing aircraft which utilizes two fixed ducted fans as its sole source of lift and propulsion. The model, having fans 28 inches in diameter, was considered to be approximately one-third the size of a full-scale aircraft. Control moments for most of the hovering tests and all the forward-flight tests were provided by remotely controlled compressed-air jets at the sides and ends of the model. For one brief phase of the hovering investigation a system of vanes in the duct slipstreams was substituted for the jets as a means of roll control. During the forward-flight tests, the model was flown with both the tandem and side-by-side duct arrangements. In hovering the model exhibited strongly divergent oscillations about the pitch and roll axes. The pitching oscillation of the tandem configuration was of a fairly long period and was not particularly difficult to control; the rolling oscillation, however, was of a relatively short period and was extremely difficult to control. Both oscillations could be completely eliminated by the addition of a sufficient amount of artificial damping. The control moments produced by the vane-type roll control system were weak and were accompanied by a side force of appreciable magnitude and undesirable direction. In forward flight the model required an undesirably large nose-down tilt angle for equilibrium at any appreciable speed. A vane was placed transversely in the slipstream of the forward duct of the tandem configuration in an attempt to reduce this tilt angle. The vane was effective in reducing the tilt angle but apparently caused an increase in the power requirements and in the angle-of-attack instability. Without the vane, a forward speed of 30 knots (full scale) required a nose-down tilt angle of about 300. A powerful pitch control moment was required not only to maintain the trim attitude but also to 2 overcome the effects of instability with angle of attack. Less pitch control moment was required for the tandem configuration than for the side-by-side configuration at any given forward speed. The instability in roll increased with forward speed. No forward speeds in excess of about 20 knots (full scale) were achieved until the artificial damping in roll and the yaw control moment were increased appreciably above values which had proved satisfactory for hovering flight.