Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “districts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Comparison of Landsat Thematic Mapper and Geophysical and Environmental Research Imaging Spectrometer data for the Cuprite mining district, Esmeralda, and Nye counties, Nevada

Landsat TM images and Geophysical and Environmental Research Imaging Spectrometer (GERIS) data were analyzed for the Cuprite mining district and compared to available geologic and alteration maps of the area. The TM data, with 30 m resolution and 6 broadbands, allowed discrimination of general mineral groups. Clay minerals, playa deposits, and unaltered rocks were mapped as discrete spectral units using the TM data, but specific minerals were not determined, and definition of the individual alteration zones was not possible. The GERIS, with 15 m spatial resolution and 63 spectral bands, permitted construction of complete spectra and identification of specific minerals. Detailed spectra extracted from the images provided the ability to identify the minerals alunite, kaolinite, hematite, and buddingtonite by their spectral characteristics. The GERIS data show a roughly concentrically zoned hydrothermal system. The mineralogy mapped with the aircraft system conforms to previous field and multispectral image mapping. However, identification of individual minerals and spatial display of the dominant mineralogy add information that can be used to help determine the morphology and genetic origin of the hydrothermal system.

Kierein-Young, Kathryn S.↗

Mapping alteration in the Goldfield Mining District, Nevada, with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

Analysis of the data acquired by the Airborne Visible/IR Imaging Spectrometer over the Goldfield Mining District, Nevada, demonstrates the unique capabilities of high resolution imaging spectrometers for alteration mapping and identification of mineralogy. The study focuses on the 2-2.45 micron window, as alteration minerals of interest have their distinctive spectral reflectance features in this region. An attempt was made to map the spatial distribution of the individual minerals and produce a mixture maps showing their relative abundance on a pixel-by-pixel basis, focussing on selected subareas. Software and SNR performances limited success in detailed mapping.

Carrere, Veronique↗

Research District Seeing Growth

Monthly economic diversity column for the Tri-City Herald (May 2012) - excerpt follows: It’s been a while since I’ve updated you on the Tri-Cities Research District, most certainly not for lack of new activity over the past several months. In fact, much has happened, and there’s more to come. I think many of us see new land development and construction as indicative of current or impending economic growth. So those of you who have ventured into North Richland either via Stevens Drive or George Washington Way lately have probably begun sensing and anticipating that such growth is afoot.

Madison, Alison L.↗

GATEWAY Report Brief: Tuning the Light in Classrooms: Evaluating Trial LED Lighting Systems in Three Classrooms at the Carrollton-Farmers Branch Independent School District in Carrollton, TX

Summary of GATEWAY report evaluating a trial installation of tunable-white LED lighting systems in three classrooms in the Carrollton-Farmers Branch Independent School District in Carrollton, TX. The report provides valuable insights into the use of this technology in a real-world setting.

GATEWAY, DOE, SSL, evaluation, demonstration, Texa↗

GATEWAY Report Brief: Tuning the Light in Classrooms: Evaluating Trial LED Lighting Systems in Three Classrooms at the Carrollton-Farmers Branch Independent School District in Carrollton, TX

Summary of GATEWAY report evaluating a trial installation of tunable-white LED lighting systems in three classrooms in the Carrollton-Farmers Branch Independent School District in Carrollton, TX. The report provides valuable insights into the use of this technology in a real-world setting.

GATEWAY, DOE, SSL, evaluation, demonstration, Texa↗

Clinical features and risk factors for adverse outcome in Ebola virus disease in Moyamba District Sierra Leone.

BACKGROUND The current outbreak of Ebola virus disease (EVD) in West Africa has attacked 24000 people, killed more than 10000 and disrupted social life. METHODS We studied retrospectively the clinical presentation and risk factors for fatal outcome in EVD among all patients admitted to the Ebola Treatment Center in Moyamba District, Sierra Leone. RESULTS Among a total of 88 admitted patients, eighty-two were tested by PCR and 31 (38%) were positive for Ebola virus. Ninety percent reported previous contact with EVD patients and 35% had participated in burials of EVD suspect deceased. No healthworkers were admitted. The most common symptoms on admission were weakness (97%), diarrhea (68%), fever (62%), loss of appetite (62%), vomiting (58%), pain in muscles (62%) and joints (55%), headache (55%), abdominal pain (45%) and conjunctivitis (42%). On admission, bleeding was present in one-third (11/31), while more than half (17/31) bled during the hospital stay. Fifty-eight percent (18/31) died, most within 4-11 days of onset. Significant predictors for fatal outcome were shorter time from onset to admission (P=0.02), high initial viral load (P<0.001), bleeding (P=0.004), and severe pain (P=0.001). The only two patients with hiccups died. CONCLUSIONS Bleeding was more common in our cohort than reported elsewhere during this epidemic, and predicted poor prognosis. Severe pain was common, particularly in fatal cases, and calls for improved and safe palliation, for instance with transdermal opiates. The lack of fever in one third of EBV cases may have implications for screening procedures and case definitions.

Haaskjold, Yngvar Lunde↗

Peña Station NEXT: Visualizing a net-zero energy district

Learn how NREL researchers are using advanced modeling and visualization tools to help create the planned net-zero energy district, Peña Station NEXT, near the Denver International Airport in Denver, Colorado. This project will result in tools for smart city design that can be applied across the country.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated Mobility Platforms (AMPs) for Versatile, Energy Efficient, Facility and District Scale Transport

The Automated Mobility Platforms (AMPs) concept is envisioned as an on-demand network of automated lightweight electric vehicles serving mobility needs in a large facility or district-scale setting. Supplanting the function of legacy automated people mover systems, AMPs is scalable to meet the needs of moving people in large interior spaces with destinations that are too distant for walking and in which larger motor vehicles would be unfeasible or undesirable. The AMPs system is designed for automated management and operation, extending to how and where the vehicles are sent to serve mobility needs, as organized through a supervisory management system. AMPs vehicles are requested by users via smartphone app or buttons located on interactive infrastructure elements. AMPs vehicles function similarly to elevators, though in the horizontal plane, wherein users summon vehicles, and are moved point-to-point, with user requested destinations set through intuitive interfaces. The concept targets extensibility, manageability, and performance improvements over legacy technologies, with accessibility and safety features integrally designed into the system.

ADA supportive modes↗

Home Energy Efficiency for the Hill District

The Hill District neighborhood in Pittsburgh, Pennsylvania worked with the U.S. Department of Energy through the Communities LEAP (Local Energy Action Program) pilot to explore strategies that improve residential energy efficiency, support the transition to renewable energy, and identify potential funding streams for increased neighborhood investment. Communities LEAP is supporting clean energy transitions in 24 communities across the United States that are facing energy-related challenges.

community↗

Geothermal Heat Pump Case Study: Berkeley County School District

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Berkeley County School District and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

15 GEOTHERMAL ENERGY↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

Well blowout rates in California Oil and Gas District 4--Update and Trends

Well blowouts are one type of event in hydrocarbon exploration and production that generates health, safety, environmental and financial risk. Well blowouts are variously defined as 'uncontrolled flow of well fluids and/or formation fluids from the wellbore' or 'uncontrolled flow of reservoir fluids into the wellbore'. Theoretically this is irrespective of flux rate and so would include low fluxes, often termed 'leakage'. In practice, such low-flux events are not considered well blowouts. Rather, the term well blowout applies to higher fluxes that rise to attention more acutely, typically in the order of seconds to days after the event commences. It is not unusual for insurance claims for well blowouts to exceed US$10 million. This does not imply that all blowouts are this costly, as it is likely claims are filed only for the most catastrophic events. Still, insuring against the risk of loss of well control is the costliest in the industry. The risk of well blowouts was recently quantified from an assembled database of 102 events occurring in California Oil and Gas District 4 during the period 1991 to 2005, inclusive. This article reviews those findings, updates them to a certain extent and compares them with other well blowout risk study results. It also provides an improved perspective on some of the findings. In short, this update finds that blowout rates have remained constant from 2005 to 2008 within the limits of resolution and that the decline in blowout rates from 1991 to 2005 was likely due to improved industry practice.

54 ENVIRONMENTAL SCIENCES↗

Metagenomes and metagenome-assembled genomes from microbial communities in a biological nutrient removal plant operated at Hamptons Road Sanitation District (HRSD) with high and low dissolved oxygen conditions

Aeration is a major cost at biological nutrient removal (BNR) plants. We report on microbial communities in a pilot-scale BNR system before and after a dissolved oxygen transition from 2.5 to 0.2 mg/L implemented over 18 months. Four PacBio metagenomes and 316 metagenome-assembled genomes are announced.

dissolved oxygen↗

Metagenomes and metagenome-assembled genomes from a nutrient removal plant at Los Angeles County Sanitation Districts (LACSD) that transitioned from high to low dissolved oxygen

Operating biological nutrient removal (BNR) wastewater treatment plants with low dissolved oxygen (DO) conditions can reduce energy costs. We report on five metagenomes and 492 metagenome-assembled genomes (MAGs) obtained from samples collected at the Pomona water reclamation plant before and after a DO reduction from 3.5 to 0.7 mg/L.

dissolved oxygen↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗