Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Trust Model Utilization for Energy Grid Communication

The internet information that is used by the Energy Grid of Things requires both preventative security measures as well as surveillance measures. The preventative security measures include certificates, encryption, and all of the basic security protocols as defined by published standards. The surveillance measures include monitoring information flow activities and evaluating these messages for indications of potential security attacks. We describe in this paper the utilization of a Distributed Trust Model that was developed specifically for monitoring communication within an Energy Grid of Things. The goal for the Distributed Trust Models is to provide a level of aggregate trust that a Distributed Energy Resource Management System can meet its grid service obligations, as opposed to a detailed individual Distributed Energy Resources assessment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FiberFlex: Real-time FPGA-based Intelligent and Distributed Fiber Sensor System for Pedestrian Recognition

In recent years, security monitoring of public places and critical infrastructure has heavily relied on the widespread use of cameras, raising concerns about personal privacy violations. To balance the need for effective security monitoring with the protection of personal privacy, we explore the potential of optical fiber sensors for this application. This article proposes FiberFlex, an intelligent and distributed fiber sensor system. Ultizing Field Programmable Gate Arrays (FPGA) high-level synthesis (HLS) acceleration, FiberFlex offers real-time pedestrian detection by co-designing the entire pipeline of optical signal acquisition, processing, and recognition networks based on the principles of optical fiber sensing. As a promising alternative to traditional camera-based monitoring systems, FiberFlex achieves pedestrian detection by analyzing the vibration patterns caused by pedestrian footsteps, enabling security monitoring while preserving individual privacy. FiberFlex comprises three modules: First , fiber-optic sensing system: A fiber-optic distributed acoustic sensing (DAS) system is built and used to measure the ground vibration waves generated by people walking. Second , algorithms: We first collect the training data by measuring the ground vibration waves, label the data, and use the data to train the neural network models to perform pedestrian recognition. Third , hardware accelerators: We use HLS tools to design hardware modules on FPGA for data collection and pre-processing and integrate them with the downstream neural network accelerators to perform in-line real-time pedestrian detection. The final detection results are sent back from FPGA to the host CPU. We implement our system FiberFlex with the in-house built DAS system and AMD/Xilinx Kintex7 FPGA KC705 board and verify the whole system using the real-world collected data. We conduct recognition tests on five test subjects of varying ages, heights, and weights in a fixed sensing area. Each subject experienced 20 real-time recognition tests using their daily walking habits, and the subjects were given adequate rest between tests. After 100 tests on five test subjects, the overall real-time recognition accuracy exceeded \(88.0\%\) . The whole system uses 55 W of power, 33 W in the optical DAS system and 22 W in the FPGA. Relying on its end-to-end interdisciplinary design, FiberFlex seamlessly combines fiber-optic sensors with FPGA accelerators to enable low-power real-time security monitoring without compromising privacy, making it a valuable addition to the existing security monitoring network. According to FiberFlex, more valuable research can be conducted in the future, such as fall monitoring for the elderly, migration of identification networks between different application scenarios, and improvement of anti-interference performance in more complex environments. In future perception networks, where the “eyes” are not feasible, let’s use fiber optic touch instead.

Distributed↗

Distributed Energy Resource Visual Emulator: Phase 1

To help federal energy managers assess, monitor, and manage cybersecurity while achieving decarbonization, the National Renewable Energy Laboratory's Distributed Energy Resource Cybersecurity Framework (DER-CF) offers a comprehensive, web-based assessment tool focusing on cyber governance or policies, technical management, and physical security. The DER-CF currently presents users with a series of pertinent cybersecurity questions, which are used to generate a site-specific report and recommendations. This paper outlines a technical approach to integrate the DER-CF with another key asset—NREL's Advanced Research on Integrated Energy Systems (ARIES) Cyber Range—to visualize cybersecurity resilience and compliance and to enhance the usability and accessibility of the DER-CF. The result is a new tool called the Distributed Energy Resource Visual Emulator (DER-VE). Its development will include regular conversations with stakeholders to assess the effectiveness of these efforts, refine the visualization capability, and ensure its value to our partners. Phase 0 of the integration project was concluded in 2021. Phase 1, completed in 2022, has two components: The first is developing a working visualization of system compliance using the DER-CF, and the second is planning the design of a server application that takes input data from the DER-CF and creates a personal emulated environment of the user's system or a selected reference architect. Major components that were addressed in this phase are the DER-CF output, compliance visualization, data model, and compliance server design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Authentication of smart grid communications using quantum key distribution

Smart grid solutions enable utilities and customers to better monitor and control energy use via information and communications technology. Information technology is intended to improve the future electric grid’s reliability, efficiency, and sustainability by implementing advanced monitoring and control systems. However, leveraging modern communications systems also makes the grid vulnerable to cyberattacks. Here we report the first use of quantum key distribution (QKD) keys in the authentication of smart grid communications. In particular, we make such demonstration on a deployed electric utility fiber network. The developed method was prototyped in a software package to manage and utilize cryptographic keys to authenticate machine-to-machine communications used for supervisory control and data acquisition (SCADA). This demonstration showcases the feasibility of using QKD to improve the security of critical infrastructure, including future distributed energy resources (DERs), such as energy storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Risk Profiles for Distributed Energy Resource Management Systems

Managing the digitalization of increasingly diversity energy resources is a complex challenge for energy systems planners and managers. As the penetration of solar photovoltaics (PV) and other distributed renewable energy resources (DERs) expands, distributed energy resource management systems (DERMS) will play an increasingly important role in managing, monitoring, and controlling DERs as electric systems before more distributed, interconnected, and networked. However, the cybersecurity implications of DERMS deployments are not well understood today. A lack of understanding around the cybersecurity implications of DERMS deployments and variability in the security posture of DERMS vendors, owners, and operators could introduce new security risks to evolving electric power systems. This paper describes cybersecurity attack scenarios on DERMS, identifies related cybersecurity standards and guidelines, reviews the security features of state-of-the-art DERMS solutions, and offers cybersecurity guidance for DERMS vendors, owners, and operators to protect DERMS' unique capabilities. Standardizing cybersecurity requirements for DERMS could help improve the security of DERMS integrations and improve innovations that are more secure by design. The cybersecurity guidance found in this paper is intended to offer a unified approach and lay the foundation for future standardization of DERMS cybersecurity to reduce risk to the solar industry and other renewable energy stakeholders when integrating these technologies with electric power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A distributed voltage inference framework for cyber-physical attacks detection and localization in active distribution grids

The transition to active distribution grids with real-time monitoring and control depends on the proliferation of advanced communication networks and devices. This paradigm shift towards a cyber-physical architecture also introduces new vulnerabilities for adversaries to exploit and launch sophisticated cyber-physical attacks targeting grid observability. Current research highlights the challenges in distinguishing attacks on voltage phasor or nodal injection measurements and isolating multi-source attack locations in a multiphase distribution grid. The attack detection and localization methods in literature face accuracy issues, applications across diverse attack scenarios, or scalability limits. Here, to bridge these gaps, this paper proposes a distributed Voltage Inference framework for real-time detection and localization of cyber-physical attacks, addressing scalability, adaptability, and accuracy challenges in state-of-the-art methods. The proposed methodology leverages the distributed nature of the Voltage Inference framework through a two-step process of prediction and correction, together with a tractable graph partitioning approach, providing a reliable solution to identify compromised measurement sources and facilitate isolation. Extensive testing on IEEE 13 and 123-node distribution feeders underscores the algorithm’s efficacy, enhancing the security and resilience of active distribution grids against evolving cyber threats. Additionally, Hardware-in-the-Loop (HIL) implementation validates the proposed strategy’s practical applicability in real-world scenarios.

active distribution grids↗

Seismic monitoring of a small CO 2 injection using a multi-well DAS array: Operations and initial results of Stage 3 of the CO 2 CRC Otway project

Active time-lapse seismic is widely employed for monitoring CO 2 geosequestration due to its ability to track the distribution of fluids in space and time. However, standard 4D seismic monitoring suffers from several challenges, including high cost, disruption to other land uses, and, consequently, relatively large intervals between monitor surveys. Some of these challenges can be mitigated using permanently installed sources and receivers. Such an approach was tested at the CO 2 CRC Otway site by continuous offset VSP monitoring of 15,000 t of supercritical CO 2 injected into an aquifer 1,500 m deep with nine permanent seismic sources (surface orbital vibrators or SOVs) and five downhole fibre-optic receivers. This continuous monitoring is complemented by multi-well 4D VSP using a mobile vibroseis source and the same DAS receivers, which included one baseline and two monitor surveys after injection of 4,000 and 12,000 t of CO 2 . The continuous DAS-SOV monitoring detected an abrupt increase of travel times below the injection interval on the second day of injection (after injection of 300 t of CO 2 ) and tracked the growth of the areal CO 2 plume by mapping changes of reflection amplitudes. The plume is also detected by time-lapse changes of reflection amplitudes in multi-well 4D VSPs. The plume images obtained from continuous offset VSP and 4D VSP are broadly consistent with each other but with some differences due to differences in illumination, lateral variations of velocities and seismic anisotropy. Furthermore, these differences also serve as a measure of uncertainty of 4D VSP images.

4D VSP↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyberattacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyberattack scenarios on matrix completion. Realistic cyberattack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation: Preprint

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyber attacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyber attack scenarios on matrix completion. Realistic cyber attack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Permanent Source - Distributed Acoustic Sensing (PESO-DAS) v1

The SOV/DAS software program focuses on seismic monitoring and data processing of permanent seismic sources Surface Orbital Vibrators (SOVs) and fiber-optics sensing Distributed Acoustic Sensing (DAS). Its key features include automated data processing of the continuous seismic monitoring data acquired with DAS, and output of processed shot gathers and QC plots. The software supports timelapse seismic for long-term reservoir monitoring, and is used for monitoring of geological carbon storage sites, geothermal reservoirs, and oil and gas, and in general subsurface resource management.

dos Santos Maia Correa, Julia [Lawrence Berkeley N↗

Biotic predictors improve species distribution models for invasive plants in Western U.S. Forests at high but not low spatial resolutions

Invasions by non-native plants threaten forest health and sustainability. The ability to predict areas at greatest risk to invasion is essential for informing both monitoring and management of invasive species. Species distribution models (SDMs) are often used to identify environmental correlates of a species’ occurrence and predict geographic areas that may be suitable for its presence and are commonly constructed using solely abiotic predictors. However, mounting evidence implies that not including biotic predictors in SDMs may yield less accurate models at some resolutions typical of landscape-scale models, although this possibility has rarely been evaluated in invasive plants. In this study, we determined whether including descriptors of the biotic environment improved the accuracy of SDMs built at five decreasing spatial resolutions for infestations of five common invasive plants in forests of California, Oregon, and Washington, USA and described environmental correlates of each species’ presence. Predictors of occurrence often echoed those identified in previous studies of the focal species, indicating that our models accurately identified important environmental drivers of occurrence. Including biotic predictors in the SDMs consistently improved model accuracy only at the highest resolution we examined, which may be due to the spatial scale at which biotic interactions primarily act to constrain species’ distributions, the particular biotic predictors we used in our models, or correlations between attributes of the abiotic and biotic environment. This finding suggests that, while the practice of building SDMs using abiotic predictors alone may generally yield models whose accuracy does not differ substantially from those that also include biotic predictors, the effects of biotic interactions on the distribution of invasive plants in forests may be detectable at larger scales than previously thought.

59 BASIC BIOLOGICAL SCIENCES↗

Synchronized Waveforms – A Frontier of Data-Based Power System and Apparatus Monitoring, Protection, and Control

Voltage and current waveforms contain the most authentic and granular information on the behaviors of power systems. In recent years, it has become possible to synchronize waveform data measured from different locations. Thus large-scale coordinated analyses of multiple waveforms over a wide area are within our reach. This development could unleash a set of new concepts, strategies, and tools for monitoring, protecting, and controlling power systems and apparatuses. This paper presents an in-depth review and analysis of the advancements in synchronized waveform data, including measurement devices, data characteristics, use cases, and comparisons with synchrophasor data. Based on the findings, five strategies are proposed to discover and develop synchronized waveform based applications over multiple application areas. The paper also presents three complementary measurement platforms and two data screening algorithms for application implementation. It further discusses committee activities and standard developments useful to explore the full potential of the data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Heat Flow and Current Distribution Analysis in the Bottom Anode of an Electric Arc Furnace Using Fiber-Optic Sensors

A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.

Bottom Anode↗

Sequential Perturbation-based FDIA Detection using DERs for Unbalanced Distribution System

The power distribution system with its reliance on automated monitoring and control infrastructure makes it a complicated cyber-physical system and vulnerable to various cyber-attacks. This paper proposes a moving target defense inspired false data injection attack (FDIA) detection mechanism for an unbalanced distribution system. In the proposed grid diagnosis service framework, the distribution system operator judiciously manipulates power outputs of a subset of inverter-based distribution energy resources (DERs) to create secret low magnitude voltage perturbations which are inconsequential to the normal operation of the grid. A mixed-integer-linear-programming algorithm is developed to select the optimal set of DERs that can create a voltage perturbation signal of the required magnitude at each sensor location at a minimum cost. Then, a sequential detector is applied that detects for the FDIA as measurements are received from individual sensors. The performance of the proposed perturbation-based FDIA detection framework is demonstrated via simulation of the IEEE 123 bus test system.

Attack Detection↗

Trust Model Measurements for the Energy Grid of Things

Information security is essential for the reliable operation of an Energy Grid of Things (EGoT). In addition to basic information security protocols as defined by published standards, there is a need for a monitoring function that measures the trustworthiness of the various actors participating in an EGoT. We describe in this paper the implementation and evaluation of a Distributed Trust Model that was developed specifically for monitoring communication within an EGoT. We then show how the model parameters are set using statistical measures for hypothesis testing.

Energy Grid of Things, EGoT, Smart Grid Security, ↗

Leveraging operational information from wastewater injection wells to evaluate CO 2 injection performance for carbon storage applications in the Appalachian Basin

Abstract Geologic parameters, geophysical logging, injection testing, and operational metrics from wastewater injection wells were integrated to develop a preliminary design of a carbon storage facility in the Appalachian Basin. A scattered group of 10–20 commercial wastewater injection wells dispose off produced water from oil and gas wells in the region, utilizing a sequence of stacked deep saline formations for injection zones. These wastewater injection wells provide practical benchmarks for understanding the feasibility of carbon dioxide (CO 2 ) storage. Geologic models were developed based on characterization data from the wastewater injection wells. Reservoir simulations were calibrated according to injection testing and operational data from the wastewater injection wells. Long‐term operational data on injection flow rates and pressures measured in the wastewater injection wells were especially useful to evaluate the performance of carbon storage applications. The simulations were used to estimate injection pressures, radius of CO 2 saturation, and pressure response for industrial scale CO 2 storage applications. Results were also used to provide a design basis in terms of number of injection wells, well spacing, area of review, injection system components, monitoring plan, and CO 2 pipeline distribution system. The analysis demonstrates that there is sufficient injectivity in the deep saline formations in the west‐central Appalachian Basin to store commercial volumes of anthropogenic CO 2 . The geologic system appears suitable for supporting CO 2 injection rates of 0.5–1.0 million metric tons per year at injection pressures below formation fracture pressure in a single well. The long‐term operational data of wastewater injection wells within the study area suggested a lower permeability‐thickness values than indicated by initial reservoir tests. A workflow for developing realistic permeability values for input into reservoir simulations is presented. © 2020 Society of Chemical Industry and John Wiley & Sons, Ltd.

Valluri, Manoj↗

Litter production and foliar nutrient resorption in fast- and slow-growing tree species in the Central Amazon

Litterfall is crucial for forest maintenance, serving as a primary mechanism for nutrient return to the nutrient-poor soils of tropical forests. Foliar nutrient resorption likewise represents an important nutrient-conservation mechanism. Yet, little is known about how these processes vary between fast- and slow-growing species in post-logging areas of the Amazon forest. Here, the objective of this study was to quantify litterfall production and the resorption of foliar nutrients in fast-growing and slow-growing tree species of the Central Amazon, in a forest that was experimentally logged in 1987. The study was conducted from May 2022 to April 2023. Litterfall was collected biweekly using four collectors that were systematically distributed beneath the canopy of each monitored tree, totaling 72 collectors. Three fast-growing and three slow-growing species were selected, each with three replicates, totaling 18 monitored individuals. Species-specific samples of fresh (green) and senesced (litter) leaves were collected and analyzed for their nutrient content and resorption efficiency. Fast-growing species had a monthly leaf litter deposition of 13.53 ± 1.6 g m −2 month −1 , compared to 2.59 ± 0.4 g m −2 month −1 for slow-growing species. The average annual litter production across both functional types was 8.6 ± 2.6 Mg ha −1 year −1 . Nutrient inputs through litterfall were higher in fast-growing species for all elements, particularly nitrogen (N), with 21.92 ± 4.9 kg ha −1 year −1 . Phosphorus (P) and potassium (K) exhibited the highest foliar resorption. P resorption efficiency was 68.3 % in fast-growing species and 57.8 % in slow-growing species. For K, efficiencies were 59.0 % and 41.7 %, respectively. These results highlight the substantial role that fast-growing species play in restoring forest productivity in managed Amazon forests, both through higher litter deposition and nutrient fluxes, and through nutrient conserving-mechanisms such as foliar nutrient resorption.

Amazon forest↗