Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed wind energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Exploring the Grid Value Potential of Offshore Wind Energy in Oregon

The grid value of Oregon's offshore wind resource is considered through the lenses of (i) resource complementarity with the hydroelectric system and other Variable Renewable Energy resources, (ii) load complementarity with the four balancing authorities with territory in Oregon, and (iii) spatial value to regional and coastal grids as represented through a Production Cost Model of the WECC system. Capacity implications of the interactions between offshore wind and the historical east-to-west power flows of the region are reviewed. The existing system is shown to accommodate 2GW of offshore wind interconnections without curtailment.

17 WIND ENERGY↗

Attack Surface of Wind Energy Technologies in the United States [Slides]

This slide deck presents an overview of the threat landscape for wind energy technologies. It highlights unique cybersecurity considerations for wind, the growing penetration and potential impact of an attack. Standard architectures are shared to highlight where vulnerabilities may exist and attack paths to reach critical infrastructure. We discuss threat actors and attack paths. Several recent events impacting wind assets or wind companies are explained.

17 WIND ENERGY↗

From Hydrometeor Size Distribution Measurements to Projections of Wind Turbine Blade Leading-Edge Erosion

Wind turbine blade leading-edge erosion (LEE) is a cause of increased operation and maintenance costs and decreased annual energy production. Thus, detailed, site-specific quantification of likely erosion conditions are critically needed to inform wind plant owner/operator decisions regarding mitigation strategies. Estimating the damage potential at a wind plant site requires accurate measurement of precipitation intensity, phase, droplet size distributions, wind speeds and their joint statistics. The current work quantifies the effect of disdrometer type on the characterization of LEE potential at a site in the US Southern Great Plains. using observations from three co-located disdrometers (an optical, an impact and a video disdrometer), along with hub-height wind-speed observations from a Doppler lidar and two LEE models: a kinetic energy model and the Springer model. Estimates of total kinetic energy of hydrometeor impacts over the four-year study period vary by as much as 38%, and coating lifetime derived from accumulated distance-to-failure estimates from the Springer model differ by an even greater amount, depending on disdrometer type. Damage potential at this site is concentrated in time, with 50% of impact kinetic energy occurring in 6–12 h per year, depending on which set of disdrometer observations is used. Rotor-speed curtailment during the most erosive 0.1–0.2% of 10 min periods is found to increase blade lifetimes and lead to the lowest levelized cost of energy.

17 WIND ENERGY↗

Assessment of wind power scenario creation methods for stochastic power systems operations

Probabilistic scenarios of renewable energy production, such as wind, have been gaining popularity for use in stochastic variants of power systems operations scheduling problems, allowing for optimal decision-making under uncertainty. The quality of the scenarios has a direct impact on the value of the resulting decisions, but until now, methods for creating scenarios have not been compared under realistic operational conditions. Here, we compare the quality of scenario sets created using three different methods, based on a simulated re-enactment of stochastic day-ahead unit commitment and subsequent dispatch for a realistic test system. We create scenarios using a dataset of forecasted and actual wind power values, scaled to evaluate the effects of increasing wind penetration levels. We show that the choice of scenario set can significantly impact system operating cost, renewable energy use, and the ability of the system to meet demand. This result has implications for the ability of system operators to efficiently integrate renewable production into their day-ahead planning, highlighting the need for the use of performance-based assessments for scenario evaluation.

17 WIND ENERGY↗

Energy 101 - Wind [Slides]

The Energy 101: Wind presentation, developed for the Energy Technology Innovation Partnership Project (ETIPP), provides an overview of wind energy. It covers fundamental concepts, technologies, considerations, case studies, and additional resources.

17 WIND ENERGY↗

Trends in Cybersecurity Threats to Clean Energy

As deployments of clean energy generation and storage assets continue to grow, the increased attack surface creates a greater risk for cyber threats, but is clean energy truly a target for cyber adversaries? This poster will present research on the trends in cyber incidents that have affected clean energy companies and assets as well as the trends in disclosed and exploited vulnerabilities. From a series of ransomware attacks on European wind manufacturers, to vulnerabilities exploited in solar assets to turn controllers into botnets, to attacks on communication infrastructure that have resulted in extended outages of remote control and monitoring, we explore the techniques used and the impacts to the clean energy sector. Key takeaways include understanding of how OT-focused malware is becoming more flexible and more destructive, how known vulnerabilities are being exploited, the growing number of IT and OT attacks that use built in tools and functionalities. Additionally, we highlight the presumed motivations and targeted sectors for various identified cyber adversaries. Viewers will leave with an understanding of how recent headlines fit into the development of cyberattack trends and what preventions they may need to take to protect against increasingly popular tactics.

14 SOLAR ENERGY↗

Distributed Wind-Hybrid Microgrids with Autonomous Controls and Forecasting

Distributed wind-hybrid microgrids have the potential to provide key resilience and economic benefits to both the customers they serve and the utility grids they are connected to. Such microgrids will likely be a key part of the grid of the future, whether connected to large utility grids or linked together in multi-microgrid systems. Through the hybridization of distributed wind and solar photovoltaics, autonomous device-level and system-level controls, battery energy storage systems with smart inverters, and forecasting, these microgrids could maintain local stability and provide grid services - all with renewable power. In the literature, these elements have been considered individually. However, they have not been combined and demonstrated at a high fidelity, which is essential to prove the concept's operation before moving to hardware-in-the-loop and physical demonstrations. In this work, we develop a high-fidelity MATLAB-Simulink model of a real distributed wind-hybrid microgrid that includes all these elements. We demonstrate the microgrid maintaining stability and production in a variety of islanded, grid-connected, and transition scenarios. This includes riding through faults and grid transitions, handling resource variability, and providing grid services. The results demonstrate, at a high fidelity, how distributed wind-hybrid microgrids can operate in an economic and resilient fashion. Finally, we provide recommendations for future research to move advanced distributed wind-hybrid microgrids toward deployment.

ancillary services↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoitaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy: Preprint

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data-Driven Generic Turbines for Distributed Wind Modeling, Optimization, and Economic Studies

As distributed energy resources (DER) become less expensive and more popular, utilities, project developers, and customers have an increasing need to model the performance of existing and proposed DER systems. Distributed wind has been shown to have widespread economic potential but is often represented by a simplified model in - or excluded from - DER modeling tools and studies. There is often no economic imperative to extend models and studies to give full consideration to distributed wind. We present a set of data-driven generic turbines derived from 16 years of annual distributed wind market survey data. The proposed methodology can be used to derive generic turbines from separate or updated data sets. Finally, a mixed-integer linear programming approach to optimal distributed wind project sizing is used to demonstrate the generic turbine models. Combined, these models and methods can reduce barriers to considering distributed wind in modeling tools and studies.

Reiman, Andrew P.↗

Accelerated cometary ions observed downstream of the Comet Halley bow shock

Results are presented of fluxes of energetic ions with energies exceeding 100 keV that were detected upstream of the bow shock of Comet Halley by the Tuende instrument on board the VEGA 1 spacecraft. Downstream of the shock, ion fluxes in the energy range 100 to 180 keV were observed. The measured ion fluxes were transformed into distribution functions in the solar wind frame using a variety of assumptions concerning the energy dependence of the distribution function and the identity of the ion species. The derived distribution function upstream of the shock falls off steeply with energy between 100 and 150 keV, with an effective temperature of about 7 keV or spectral index of about -15. The distribution function increases with decreasing cometocentric distance, on average, reaching a maximum at the bow shock. The measured distribution functions are compared with those obtained by similar instruments on Giotto and ICE as well as with the predictions of several theoretical models that employ different acceleration mechanisms.

Kecskemety, K.↗

Tangible Solutions for Grid Operation Upgrade

Many countries worldwide are setting clean energy targets to decarbonize the energy sector and add higher wind and solar capacities. Given their distributed nature, variable renewable energy (VRE) assets can have unique grid integration considerations, and require grid operation practices to be modernized. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage renewable energy resource operation in the system control center. Further, system operation planning is conducted with VRE and load forecasting to enable reliable real-time system operation. NREL has partnered with many system operators in the region to identify appropriate technology and grid modernization solutions. NREL and partners from system operators in the region will present on the challenges and some solutions that have been applied and share best practices such as energy management system upgrades, VRE forecasting framework, grid flexibility improvements, and staff training.

emerging economies↗

Case Study: Applying the INL Resilience Framework to Iowa Lakes Electric Cooperative Distributed Wind Systems

Traditional metrics and evaluation methods for resiliency are not sufficient to evaluate the effect that distributed wind systems will have, particularly in light of the challenges described above. While the concept of resiliency is not new, its application to the electric grid is neither standardized nor well-defined, and there is little to no guidance on how to evaluate resilience specifically for distributed wind systems. To fill this gap, the Idaho National Laboratory (INL), as part of the multi-laboratory Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project, has developed a resilience framework for electric energy delivery systems (EEDS). The framework provides detailed steps for evaluating resiliency in the planning, operational, and future stages, and encompasses five core functions of resilience. It allows users to evaluate the resilience of distributed wind, taking into consideration the resilience of the wind systems themselves, as well as the effect they have on the resiliency of any systems they are connected to. In this study, we evaluate the resilience of the distributed wind systems at Iowa Lakes Electric Cooperative to cybersecurity hazards. We show that the wind resource can benefit the overall system resilience during some hazards. We show that the practices in place make the wind subsystems resilient against some cybersecurity hazards but that there are still significant risks associated with other cybersecurity hazards

17 WIND ENERGY↗

Preliminary Assessment of Renewable Energy Options at the Sravasti Abbey [Slides]

Through the U.S. Department of Energy's Energy to Communities (E2C) program, NREL, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term clean energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional clean energy expertise to inform key upcoming decisions. This Expert Match request supported the Sravasti Abbey in Washington a preliminary assessment of distributed energy technology financial feasibility for their site. The outcome consists of low estimated savings from these technologies due to their already low energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sensitivity of fatigue reliability in wind turbines: effects of design turbulence and the Wöhler exponent

Fatigue assessment of wind turbines involves three main sources of uncertainty: material resistance, load, and the damage accumulation model. Many studies focus on increasing the accuracy of fatigue load assessment to improve the fatigue reliability. Probabilistic modeling of the wind's turbulence standard deviation is an example of an approach used for this purpose. Editions 3 and 4 of the IEC standard for the design of wind energy generation systems (IEC 61400-1) suggest different probability distributions as alternatives for the representative turbulence in the normal turbulence model (NTM) of edition 1. There are debates on whether the suggested distributions provide conservative reliability levels, as the established design safety factors are calibrated based on the representative turbulence approach. The current study addresses the debate by comparing annual reliability based on different scenarios of NTM using a probabilistic approach. More importantly, it elaborates on the relative importance of load assessment accuracy in defining the fatigue reliability. Using the DTU 10 MW reference wind turbine and the first-order reliability method (FORM), we study the changes in the annual reliability level and its sensitivity to the three main random inputs. We perform the study considering the blade root flapwise and the tower base fore–aft moments, assuming different fatigue exponents in each load channel. The results show that integration over distributions of turbulence in each mean wind speed results in less conservative annual reliability levels than representative turbulence. The difference in the reliability levels varies according to turbulence distribution and the fatigue exponent. In the case of the tower base, the difference in the annual reliability index after 20 years can be up to 50 %. However, the model and material uncertainty have much higher effects on the reliability levels compared to load uncertainty. Knowledge about such differences in the reliability levels due to the choice of turbulence distribution is especially important, as it impacts the extent of lifetime extension through reliability reassessments.

17 WIND ENERGY↗