Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “discrimination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffusion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the scintillation region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the top quark mass using events with a single reconstructed top quark in pp collisions at $$ \sqrt{s} $$ = 13 TeV

A measurement of the top quark mass is performed using a data sample enriched with single top quark events produced in the t channel. The study is based on proton- proton collision data, corresponding to an integrated luminosity of 35.9 fb -1 , recorded at √s = 13 TeV by the CMS experiment at the LHC in 2016. Candidate events are selected by requiring an isolated high-momentum lepton (muon or electron) and exactly two jets, of which one is identified as originating from a bottom quark. Multivariate discriminants are designed to separate the signal from the background. Optimized thresholds are placed on the discriminant outputs to obtain an event sample with high signal purity. The top quark mass is found to be $172.13^{+0.76}_{-0.77}$ GeV, where the uncertainty includes both the statistical and systematic components, reaching sub-GeV precision for the first time in this event topology. The masses of the top quark and antiquark are also determined separately using the lepton charge in the final state, from which the mass ratio and difference are determined to be $0.9952^{+0.0079}_{-0.0104}$ and $0.83^{+1.79}_{-1.35}$ GeV, respectively. The results are consistent with CPT invariance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of simulated reduced injected dose on the assessment of amyloid PET scans

To investigate the impact of reduced injected doses on the quantitative and qualitative assessment of the amyloid PET tracers [ 18 F]flutemetamol and [ 18 F]florbetaben. Cognitively impaired and unimpaired individuals (N = 250, 36% Aβ-positive) were included and injected with [ 18 F]flutemetamol (N = 175) or [ 18 F]florbetaben (N = 75). PET scans were acquired in list-mode (90–110 min post-injection) and reduced-dose images were simulated to generate images of 75, 50, 25, 12.5 and 5% of the original injected dose. Images were reconstructed using vendor-provided reconstruction tools and visually assessed for Aβ-pathology. SUVRs were calculated for a global cortical and three smaller regions using a cerebellar cortex reference tissue, and Centiloid was computed. Absolute and percentage differences in SUVR and CL were calculated between dose levels, and the ability to discriminate between Aβ- and Aβ + scans was evaluated using ROC analyses. Finally, intra-reader agreement between the reduced dose and 100% images was evaluated. At 5% injected dose, change in SUVR was 3.72% and 3.12%, with absolute change in Centiloid 3.35CL and 4.62CL, for [ 18 F]flutemetamol and [ 18 F]florbetaben, respectively. At 12.5% injected dose, percentage change in SUVR and absolute change in Centiloid were < 1.5%. AUCs for discriminating Aβ- from Aβ + scans were high (AUC ≥ 0.94) across dose levels, and visual assessment showed intra-reader agreement of > 80% for both tracers. This proof-of-concept study showed that for both [ 18 F]flutemetamol and [ 18 F]florbetaben, adequate quantitative and qualitative assessments can be obtained at 12.5% of the original injected dose. However, decisions to reduce the injected dose should be made considering the specific clinical or research circumstances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Velocity Extraction Using Complete Time-Domain Waveform Data and Audio Machine Learning

We developed a new machine learning-based tool for extracting information from interferometry measurements: MIDWAZE (Modular Interferometry Direct Waveform AnalyZEr). This paper showcases MIDWAZE’s ability to extract an object’s velocity information from Photonic Doppler Velocimetry (PDV) data at near-human accuracy with little to no human intervention. MIDWAZE can extract velocities roughly 350 times as fast as a human analyst "rushing" to complete their extractions, with similar extraction accuracy. MIDWAZE’s most outstanding feature is that it operates directly in waveform/temporal space, freeing analysis from certain limitations imposed by traditional spectrogram-based approaches and opening the way to "phase aware" PDV analysis. MIDWAZE also has limited ability to discriminate between different solid objects, which we develop as a first step towards automated discrimination of different kinds of objects such as ejecta clouds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dielectrophoresis assisted rapid, selective and single cell detection of antibiotic resistant bacteria with G-FETs

Time-consuming, expensive and low sensitivity diagnostic methods used for monitoring bacterial infections lead to unnecessary or delays in prescription of the right antibiotic treatment. Determining an optimal clinical treatment requires rapid detection and identification of pathogenic bacteria and their sensitivity to specific antimicrobials. However, diagnostic devices that meet all of these criteria have proven elusive thus far. Graphene field effect transistors (G-FET) are a promising solution, since they are highly sensitive to chemical/biological modification, can have fast detection times and can be placed on different substrates. Here, by integrating specific peptide probes over G-FETs, we present a proof-of-concept study for species and strain specific label-free detection of clinical strains of pathogenic bacteria with high specificity and sensitivity. We found that pyrene-conjugated peptides immobilized on G-FETs were capable of detecting pathogenic Staphylococcus aureus at the single-cell level and discriminate against other gram-positive and gram-negative bacterial pathogens. A similar device was able to discriminate between antibiotic resistant and sensitive strains of Acinetobacter baumannii , suggesting that these devices can also be used for detecting antibiotic resistive pathogens. Furthermore, a new means of enhancing attachment, electric-field assisted binding, reduced the detection limit to 104 cells/ml and the detection time to below 5 minutes. Here, the combination of single step attachment, inexpensive production, rapid, selective and sensitive detection suggest G-FETs plus pyrene-conjugated peptides are a new platform for solving major challenges faced in point of care diagnostics to fight infectious diseases and antimicrobial resistance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Data analytics for leak detection in a subcritical boiler

For decades, boiler leaks have been the leading cause of forced outages in the coal-fired unit. The leak occurrences are currently escalating since the existing plants must satisfy faster-ramping rates to support grid operation. Data analytics including Principal Component Analysis, Canonical Variate, and Fisher Discriminant Analysis were combined for detecting and characterizing the leak in a commercial 650 MW subcritical coal-fired power plant. The combined approach was shown to be highly effective in the fault investigation that would not have been easily achieved by an individual technique. The variability in both training and validation datasets was first evaluated using PCA. Then, the CV-FDA was employed to discriminate among faults, and to categorize the processed data into two main groups: no-leak (0) and leak (1), providing the timeframe and location of the leak occurrence. Furthermore, about 8,014 observations from 81 process variables were initially included in the calculation, while the variable count was reduced to 4 with less than 1% misclassification rate in total observations. Finally, the leak was isolated in the waterwall section. Thus, the outcome of this research may provide early detection and isolation of faulty operations in the coal-fired power plant that involves a considerable number of process variables.

20 FOSSIL-FUELED POWER PLANTS↗

Time-Lapse Gravity Monitoring of CO2 Migration Based on Numerical Modeling of a Faulted Storage Complex

In this study, the performance of both surface and borehole time-lapse gravity monitoring to detect CO2 leakage from a carbon storage site is evaluated. Several hypothetical scenarios of CO2 migration in a leaky fault, and thief zones at different depths at the Kimberlina site (California, USA) constitute the basis of the approach. The CO2 displacement is simulated using the TOUGH2 simulator applied to a detailed geological model of the site. The gravity responses to these CO2 plumes are simulated using forward modeling with sensors at ground surface and in vertical boreholes. Results of inversion on one scenario are also presented. The surface-based gravity responses obtained for the different leakage scenarios demonstrate that leakage can be detected at the surface in all the scenarios but the time to detection is highly variable (10 to 40 years) and dependent on the detection threshold considered. Borehole measurements of the vertical component of gravity provide excellent constrains in depth when they are located in proximity of the density anomaly associated with the presence of CO2, thus discriminating multiple leaks in different thief zones. Joint inversion of surface and borehole data can bring valuable information of the occurrence of leakages and their importance by providing a reasonable estimate of mass of displaced fluids. This study demonstrates the importance of combining multiphase flow simulations with gravity modeling in order to define if and when gravity monitoring would be applicable at a given storage site.

Time-lapse gravity monitoring, leak detection, CCS↗

Some observations concerning "laminarization" in heated vertical tubes

For low "turbulent" Reynolds numbers in strongly-heated vertical gas flow, fundamental results of existing direct numerical simulation (DNS) databases have been examined to deduce differences between cases which "revert" to turbulent and those that yield integral parameters which correspond to laminar flow (henceforth laminarizing or laminarized). The objectives of this paper are (1) to examine the streamwise evolution of near-wall flow structures and (2) to determine which, if any, proposed laminarization parameters could be used to discriminate between turbulent and laminarizing flows resulting. Views of streamlines in r-θ cross sections showed evidence of a ring of irregular-shaped streamwise vortices near the wall at all locations. The transverse advection of these vortices is hypothesized to provide a path of least resistance to the transport of streamwise momentum in the wall-normal direction. It is demonstrated that a steady streamwise laminar vortex can provide apparent turbulent momentum transport (as a consequence of the Reynolds decomposition) such that a reasonable mean velocity profile is predicted near the wall. For the present cases, the values of the non-dimensional radius (y c,w + = Re τ,w ) and of the modified wall Reynolds number did discriminate whether turbulent or laminarizing flow resulted.

99 GENERAL AND MISCELLANEOUS↗

Post-remediation geophysical assessment: Investigating long-term electrical geophysical signatures resulting from bioremediation at a chlorinated solvent contaminated site

There is a growing need to assess long-term impacts of active remediation strategies on treated aquifers. A variety of biogeochemical alterations can result from interactions of the amendment with the aquifer, conceivably leading to a geophysical footprint of the long-term alteration of an aquifer. This concept of post-remediation geophysical assessment was investigated in a shallow, chlorinated solvent-contaminated aquifer six to eight years after amendment delivery. Surface resistivity imaging and cross-borehole resistivity and induced polarization (IP) imaging were performed on a transect that spanned treated and untreated zones of the aquifer. Established relationships between IP parameters and surface electrical conductivity were used to predict vertical profiles of electrolytic conductivity and surface conductivity from the inverted cross-borehole images. Aqueous geochemistry data, along with natural gamma and magnetic susceptibility logs, were used to constrain the interpretation. The electrical conductivity structure determined from surface and borehole imaging was foremost controlled by the electrolytic conductivity of the interconnected pore space, being linearly related to fluid specific conductance. The electrolytic conductivity (and thus the conductivity images alone) did not discriminate between treated and untreated zones of the aquifer. In contrast, inverted phase angles and surface conductivities did discriminate between treated and untreated zones of the aquifer, with the treated zone being up to an order of magnitude more polarizable in places. Supporting aqueous chemistry and borehole logging datasets indicate that this geophysical footprint of the long-term impact of the remediation on the aquifer is most likely associated with the formation of polarizable, dispersed iron sulfide minerals. The study opens the door to the possibility of employing time-lapse electrical geophysical measurements to assist with long-term environmental stewardship of legacy sites undergoing active remediation.

bioremediation↗

Phonon-mediated high-voltage detector with background rejection for low-mass dark matter and reactor coherent neutrino scattering experiments

We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. Furthermore, this new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast-neutron/gamma-ray radiography using a broad-energy neutron source

Transmission radiography is a well-established nondestructive examination technique with widespread application to fields ranging from medicine to security. Traditionally, inspection is performed using a single particle type (such as x-rays). However, the information available using a single probe for traditional radiography is limited. The present work evaluates material discrimination via transmission radiography using the attenuation ratio of monoenergetic gamma rays to a broad spectrum of fast neutrons. Here, the method was assessed using an 241 Am/Be radioisotope source that provides both 4.4 MeV gamma rays and a spectrum of fast neutrons up to 12 MeV. A total of 14 object configurations were measured: seven different materials each with two thicknesses (2.5 cm and 5 cm). The ability to distinguish materials was evaluated and shows more significant variation among atomic numbers than for high-energy x-rays alone, making it easier to distinguish between classes such as low-, mid-, and high-Z materials. These results suggest that superior material discrimination is also possible using a combination of monoenergetic gamma rays and broad-spectrum fast neutrons from a variety of nuclear reactions, such as 11 B(d,nγ) 12 C, that could be implemented in future inspection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A sub-5 ps jitter time-to-digital converter ASIC with back-gate delay tuning in 22 nm CMOS

We present the design of a Time-to-Digital Converter (TDC) ASIC together with performance characterization results at cryogenic temperature (6-8 K), and at room temperature using emulated Low-Gain Avalanche Detector (LGAD) signals. The TDC design uses a two-step architecture with a ring-oscillator based counter and a Vernier delay line fine TDC. The TDC is implemented in an FD-SOI process, and back-gate tuning is used not only to correct threshold variation due to cryogenic operation, but also as a novel way to tune TDC delay elements with very little overhead. Using this technique, we demonstrate a design with very low power (0.5 mW) and area (0.003 mm 2 ). We present test results using the Fermilab Constant Fraction Discriminator (FCFD) ASIC to produce discriminated signals from an internal charge injection mechanism that mimics the waveform and signal amplitude of minimum ionizing particles impinging on LGAD sensors. We characterize the time precision of the full system and verify that the TDC ASIC contributes a negligible amount to the total system time precision, fully consistent with the expected jitter contribution of less than 5 ps. In conclusion, the results presented here demonstrate the utility of our TDC for applications in physics and quantum communications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultracentral Collisions of Small and Deformed Systems at RHIC

We study a range of collision systems involving deformed ions and compare the elliptic and triangular flow harmonics produced in a hydrodynamics scenario versus a color glass condensate (CGC) scenario. For the hydrodynamics scenario, we generate initial conditions using TRENTO and work within a linear response approximation to obtain the final flow harmonics. For the CGC scenario, we use the explicit calculation of two-gluon correlations taken in the high-p T “(semi)dilute-(semi)dilute” regime to express the flow harmonics in terms of the density profile of the collision. Here, we consider ultracentral collisions of deformed ions as a testbed for these comparisons because the difference between tip-on-tip and side-on-side collisions modifies the multiplicity dependence in both scenarios, even at zero impact parameter. We find significant qualitative differences in the multiplicity dependence obtained in the initial conditions+hydrodynamics scenario and the CGC scenario, allowing these collisions of deformed ions to be used as a powerful discriminator between models. We also find that sub-nucleonic fluctuations have a systematic effect on the elliptic and triangular flow harmonics which are most discriminating in 0–1% ultracentral symmetric collisions of small deformed ions and in 0–10% d197Au collisions. The collision systems we consider are 238 U 238 U, d 197 Au, 9 Be 197 Au, 9 Be 9 Be, 3 He 3 He, and 3 He 197 Au.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Harmonizing solar induced fluorescence across spatial scales, instruments, and extraction methods using proximal and airborne remote sensing: A multi-scale study in a soybean field

Solar-induced chlorophyll fluorescence (SIF) has been widely used to track vegetation photosynthesis at different scales ranging from in-situ measurements to satellite products. Airborne platforms sample SIF data at a spatial scale intermediate between in-situ and satellite, matching that of ground measurement (e.g. flux tower footprints and other field sampling), enabling us to explore causes of SIF variation and validate satellite-based SIF products. However, harmonizing SIF across sensors and platforms (correcting for systematic errors to yield a consistent, comparable SIF product) is challenging because SIF can be retrieved in different absorption windows, with different instruments and methods complicating the comparison between different observational levels (i.e., ground, airborne, satellites) and between sites equipped with different instruments with varying optical properties (spectral resolution and sampling intervals, spatial resolution). Additionally, the spatial and temporal variability of atmospheric properties can influence the retrieval of the weak SIF signal. Because of these complications, direct comparisons of airborne and ground SIF across scales are rarely attempted. Here, in this study, we combined airborne SIF data with simultaneous ‘ground truth’ data collected by stationary and mobile platforms in a soybean field in Nebraska, USA. In this effort, we tested several SIF extraction methods, including Fraunhofer Line Discrimination (FLD), improved Fraunhofer Line Discrimination (iFLD), Spectral Fitting Method (SFM), SpecFit, and a Singular Vector Decomposition (SVD) method. The SpecFit method was sensitive to the 715–740 nm water bands and removing the water bands in the fitting process yielded better agreement between the airborne and ground SIF spectra. Accurate estimation of the ground level downwelling irradiance obtained by ground measurements over a calibration target improved agreement between airborne and ground SIF retrievals at the O 2 A band, and allowed us to derive a SIF dataset with improved agreement across platforms and sampling scales. This experimental approach provided a method for generating comparable SIF signals across instruments, methods and platforms, which is critical to understanding the SIF-GPP relationship at different scales and to cross-validate the diversity of platforms used for satellite products calibration and validation.

54 ENVIRONMENTAL SCIENCES↗

Heterogeneous response of cancer-associated fibroblasts to the glucose deprivation through mitochondrial calcium uniporter

Highlights: • CAFs from a tumor mass are heterogeneous under the glucose deficient condition. • CAFs survive under glucose deficient condition by activation of TGF-β and calcium. • Calcium influx to mitochondria is critical for survival of glucose-deficient CAFs. • MCU in CAFs could be a feasible target for the development of anticancer drugs. Cancer-associated fibroblasts (CAFs) are an abundant component of the tumor microenvironment and have distinct features from normal fibroblasts (NFs). However, the discriminative nature of heterogeneous CAFs under glucose starvation remains unknown. In this study, we investigated the changes in the mitochondrial calcium concentration and relevant intracellular machinery in CAFs under glucose-deficient conditions. Xenografted tumor masses were dissected into multiple pieces and subjected to the CAF isolation using magnetically activated cell sorting (MACS). NFs were separated from the normal lung and skin. Under glucose starvation, CAFs from the tumor mass exhibited heterogeneity in cell proliferation, ATP production and calcium concentration. Compared to NFs, mitochondrial calcium concentration was significantly higher in glucose-starved CAFs with upregulation of mitochondrial calcium uniporter (MCU) that led to enhancement of ATP production and cell growth. Intriguingly, treatment of glucose-starved CAFs with oligomycin increased apoptosis by disrupted calcium homeostasis following overactivation of the mPTP. Moreover, oligomycin-induced apoptosis was mitigated by calcium chelation. This study demonstrated that the discriminative calcium influx to mitochondria through MCU coordinated cell growth and apoptosis in glucose-starved CAFs but not in NFs.

60 APPLIED LIFE SCIENCES↗

Using low-coverage whole genome sequencing (genome skimming) to delineate three introgressed species of buffalofish ( Ictiobus )

Consumption of buffalofish has been sporadically associated with Haff disease-like illnesses involving sudden onset muscle pain and weakness due to skeletal muscle rhabdomyolysis, but determination of precisely which species are associated with these illnesses has been impeded by a lack of species-specific DNA-based markers. Here, three closely related species of buffalofish native to the Mississippi River Basin (Ictiobus bubalus, Ictiobus cyprinellus and Ictiobus niger) that have previously proven genetically indistinguishable using both mitochondrial and nuclear single-locus sequencing were reliably discriminated using low-coverage whole genome sequencing (‘genome skimming’). Using 44 specimens representing the three species collected from the mid/upper (Missouri) and lower (Louisiana) regions of the species’ native ranges, the SISRS (Site Identification from Short Read Sequences) bioinformatics pipeline was adapted to (1) identify over 620Mbp of putatively homologous nuclear sequence data and (2) isolate over 140,000 single-nucleotide polymorphisms (SNPs) that supported accurate species delimitation, all without the use of a reference genome or annotation data. These sites were used to classify Ictiobus spp. samples with genome-skim data, along with a larger set (n = 67) where ultraconserved elements (UCEs) were sequenced. Analyses of whole mitochondrial data revealed more limited signal. Nearly all samples matched their purported species based on morphologic identification, but two Missouri samples morphologically identified as I. niger grouped with samples of I. bubalus, albeit with significant enrichment of I. niger SNPs. To our knowledge this is the first report of a DNA-based tool to reliably discriminate these three morphologically distinct species.

59 BASIC BIOLOGICAL SCIENCES↗