Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “directional heat flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Evaluation of advanced component concepts for an integrated environmental control/life support, resistojet control system

Flow restricting devices were studied for their suitability as liquid water propellant flow limiters for the biowaste resistojet. Flow limiting during the start-up transient is required to prevent thrustor instabilities and icing which could result in heater failure in the electrical resistance heated thrustor (resistojet). The study was directed toward simple devices which would function passively (i.e., without power except from the propellant flow itself), and would offer high reliability and simplicity. In addition to the flow limiting devices, a thermal pumping system was studied to determine whether CO2, desorbed from molecular sieves could be pumped thermally in a space station application. The thermal pump is considered a possible replacement for mechanical pumps. It involves a cyclic, constant volume cryopumping system which employs space radiators to achieve the cryotemperatures. The frozen CO2 would be vaporized periodically, using a waste heat loop, to attain sufficient pressure to transfer a large portion of the trapped CO2 to storage tanks.

Halbach, C. R.↗

TACT1, a computer program for the transient thermal analysis of a cooled turbine blade or vane equipped with a coolant insert. 1. Users manual

A computer program to calculate transient and steady state temperatures, pressures, and coolant flows in a cooled, axial flow turbine blade or vane with an impingement insert is described. Coolant side heat transfer coefficients are calculated internally in the program, with the user specifying either impingement or convection heat transfer at each internal flow station. Spent impingement air flows in a chordwise direction and is discharged through the trailing edge and through film cooling holes. The ability of the program to handle film cooling is limited by the internal flow model. Sample problems, with tables of input and output, are included in the report. Input to the program includes a description of the blade geometry, coolant supply conditions, outside thermal boundary conditions, and wheel speed. The blade wall can have two layers of different materials, such as a ceramic thermal barrier coating over a metallic substrate. Program output includes the temperature at each node, the coolant pressures and flow rates, and the inside heat-transfer coefficients.

Gaugler, R. E.↗

Jet array impingement heat transfer characteristics

Two dimensional arrays of circular air jets impinging on a heat transfer surface parallel to the jet orifice plate are considered. The jet flow, after impingement, is constrained to exit in a single direction along the channel formed by the jet orifice plate and the heat transfer surface. In addition to the crossflow which originates from the jets following impingement, an initial crossflow is present which approaches the array through an upstream extension of the channel. The configurations considered are intended to model the impingement cooled midchord region of gas turbine airfoils in cases where an initial crossflow is also present. A major objective is determination of the effect of initial crossflow air temperature relative to jet array air temperature on impingement surface heat fluxes.

Florschuetz, L. W.↗

Self-generated magnetic fields in the hot spot of direct-drive cryogenic implosions at Omega

This work reports that Biermann self-generated magnetic fields of ≈200 MG and Hall parameters of ≈1.5 are produced in the stagnation phase of direct-drive cryogenic implosions at Omega. The magnetic fields produce a drop of 2.4% in fusion yield and 1% in ion temperature. A quantitative estimate of the effect of self-generated magnetic fields on yield and ion temperature is essential, since direct measurements of these fields are not available. Reconstructed simulations of the 50 Gbar implosions, with all the stagnation measurements reproduced simultaneously by a combination of mid- and low-mode asymmetries as degradation mechanisms [Bose et al., Phys. Plasmas 25, 062701 (2018)], are used to obtain the estimates. The magnetic fields cause a decrease in yield due to the Righi–Leduc heat flow, which exceeds any benefits from heat flow suppression due to magnetization. It is important to note that both direct-drive Omega-scale implosions and indirect-drive National Ignition Facility (NIF)-scale implosions [Walsh et al., Phys. Rev. Lett. 118, 155001 (2017)] produce similar estimates for the magnetic field strength, and both show a decrease in fusion yield, with the Righi–Leduc transport as the loss mechanism. However, the yield degradation at Omega is small and lower by ≈5× compared to the indirect-drive ignition-scale NIF estimate.

Physics↗

Influence of extreme fracture flow channels on the thermal performance of open-loop geothermal systems at commercial scale

Abstract Adequate stewardship of geothermal resources requires accurate forecasting of long-term thermal performance. In enhanced geothermal systems and other fracture-dominated reservoirs, predictive models commonly assume constant-aperture fractures, although spatial variations in aperture can greatly affect reservoir permeability, fluid flow distribution, and heat transport. Whereas previous authors have investigated the effects of theoretical random aperture distributions on thermal performance, here we further explore the influence of permeability heterogeneity considering field-constrained aperture distributions from a meso-scale field site in northern New York, USA. Using numerical models of coupled fluid flow and heat transport, we conduct thermal–hydraulic simulations for a hypothetical reservoir consisting of a relatively impervious porous matrix and a single, horizontal fracture. Our results indicate that in highly channelized fields, most well design configurations and operating conditions result in extreme rates of thermal drawdown (e.g., 50% drop in production well temperatures in under 2 years). However, some other scenarios that account for the risks of short-circuiting can potentially enhance heat extraction when mass flow rate is not excessively high, and the direction of geothermal extraction is not aligned with the most permeable features in the reservoir. Through a parametric approach, we illustrate that well separation distance and relative positioning play a major role in the long-term performance of highly channelized fields, and both can be used to help mitigate premature thermal breakthrough.

Rangel-Jurado, Nicolás↗

Three-dimension heat transfer program

An IBM 7094, three dimensional, heat transfer program for satellite application is discussed. The program may be applied to all phases of spacecraft life, from launch to orbital quasi-steady state. Launch phase heating includes inputs by radiation from the hot fairing and free molecule flow heating after nose cone ejection. Orbital heat fluxes are accounted for by direct sunlight, earth-reflected sunlight, and earth-emitted input to the satellite. Internal heat exchange by conduction and radiation is determined, provided the appropriate conductances, radiation view factors, and effective emittances are known. A simplified analysis of an active thermal controlled spacecraft is incorporated into the program. One or more surfaces may contain shutter systems which have optical properties specified as a function of shutter opening. The program evaluates the feasibility of any configuration based upon maintaining an internal component within its tolerable temperature limits. The program employs a matrix inversion subroutine (Gauss Elimination Method) to solve the heat balance equations.

COMPUTER PROGRAM↗

Airflow Assists Solar Receiver

Heat loss by convection reduced. Simplified solar receiver concept involves inwardly directed flow of cooling air and "air door" to reduce loss by convection. Receiver is constructed from inexpensive materials.

Revere, W. R.↗

Phase Separators And Fountain-Effect Pumps For He 11

Fused-glass microchannel arrays for use as HE 11 phase separators and fountain-effect pumps. Microchannel devices for use in low-gravity storage and cooling systems containing superfluid helium. Phase separators and pumps take advantage of thermomechanical effect peculiar to He 11 in restricted spaces. By creating thermal gradient in porous plug, direction of flow reversed, turning phase separator into pump. However, addition of heat disadvantage. Thermal gradient created by using Peltier effect to transfer heat across array, removing heat from He 11 supply and overcoming undesirable addition of heat.

Whitehouse, Paul L.↗

The correspondence between X-ray bright points and evolving magnetic features in the quiet sun

The results of a study of X-ray bright points (XBPs) and small-scale evolving magnetic structures are presented. X-ray images obtained during rocket flights, full-disk magnetograms, and time-lapse magnetograms of multiple fields make up the coordinated data set. XBPs were found to be more frequently associated with pre-existing magnetic features of opposite polarity which appeared to be cancelling than with new or emerging flux regions. Most of the XBPs appeared to correspond to opposite polarity magnetic features which were converging towards each other, and some of which had not yet begun cancelling. It is suggested that most XBPs are created when converging flow brings together oppositely directed field lines. This leads to reconnection and heating in the low corona of the newly-formed loops.

Webb, D. F.↗

Direct numerical simulation of hot jets

The ultimate motivation of this work is to investigate the stability of two dimensional heated jets and its implications for aerodynamic sound generation from data obtained with direct numerical simulations (DNS). As pointed out in our last report, these flows undergo two types of instabilities, convective or absolute, depending on their temperature. We also described the limits of earlier experimental and theoretical studies and explained why a numerical investigation could give us new insight into the physics of these instabilities. The aeroacoustical interest of these flows was also underlined. In order to reach this goal, we first need to succeed in the DNS of heated jets. Our past efforts have been focused on this issue which encountered several difficulties. Our numerical difficulties are directly related to the physical problem we want to investigate since these absolutely or almost absolutely unstable flows are by definition very sensitive to the smallest disturbances and are very likely to reach nonlinear saturation through a numerical feedback mechanism. As a result, it is very difficult to compute a steady laminar solution using a spatial DNS. A steady state was reached only for strongly co-flowed jets, but these flows are almost equivalent to two independent mixing layers. Thus they are far from absolute instability and have much lower growth rates.

Jacob, Marc C.↗

Heat transfer characteristics for inline and staggered arrays of circular jets with crossflow of spent air

Heat transfer characteristics were measured for two dimensional arrays of jets impinging on a surface parallel to the jet orifice plate. The impinging flow was constrained to exit in a single direction along the channel formed by the jet plate and the heat transfer surface. Both mean Nusselt numbers and streamwise Nusselt number profiles are presented as a function of Reynolds number and geometric parameters. These are the streamwise and transverse hole spacings ranging from 5 to 10 and 4 to 8 jet orifice diameters, respectively; the channel height ranging from 1 to 6 diameters; and the hole pattern which includes both inline and staggered arrays. The results show that significant periodic variations occur in the streamwise Nusselt number profiles, persisting downstream for at least ten rows of jet holes. Channel height can have a significant effect on the chordwise profiles, smoothed across the periodic variations. For the smaller channel heights, Nusselt numbers first decrease and then increase downstream. Where significant differences exist, inline hole patterns provide better heat transfer than staggered ones. These and other effects of the geometric parameters are presented and discussed.

Metzger, D. E.↗

Combined Radiation and Forced Convection for Flow of a Transparent Gas in a Tube with Sinusoidal Axial Wall Heat Flux Distribution

An analysis is made of the influence that radiation exchanges between elements on the inside surface of a tube have on the wall and gas temperature distributions for forced-convection flow. The wall heat generation has a chopped sine distribution with length along the tube, which is a distribution often encountered in nuclear-reactor channels. The flowing gas is assumed transparent to thermal radiation and hence does not participate directly in the radiative exchange process. Axial heat conduction is neglected in the gas and tube wall, and the convective-heat-transfer coefficient and fluid properties are assumed constant. Several numerical examples are given to illustrate the effects of eight independent parameters such as wall emissivity, Stanton number, and length-diameter ratio. In some instances the radiation exchanges reduced the peak wall temperature or caused a reduction in the exit gas temperature because of radiation losses from the tube end openings.

TUBE↗

Temperature distribution in internally heated walls of heat exchangers composed of nonnuclear flow passages

In the walls of heat exchangers composed of noncircular passages, the temperature varies in the circumferential direction because of local variations of the heat-transfer coefficients. A prediction of the magnitude of this variation is necessary in order to determine the region of highest temperature and in order to determine the admissible operating temperatures. A method for the determination of these temperature distributions and of the heat-transfer characteristics of a special type of heat exchanger is developed. The heat exchanger is composed of polygonal flow passages and the passage walls are uniformly heated by internal heat sources. The coolant flow within the passages is assumed to be turbulent. The circumferential variation of the local heat-transfer coefficients is estimated from flow measurements made by Nikuradse, postulating similarity between velocity and temperature fields. Calculations of temperature distributions based on these heat-transfer coefficients are carried out and results for heat exchangers with triangular and rectangular passages are presented.

Eckert, E R G↗

Heat transfer and pressure measurements for the SSME fuel turbine

A measurement program is underway using the Rocketdyne two-stage Space Shuttle Main Engine (SSME) fuel turbine. The measurements use a very large shock tunnel to produce a short-duration source of heated and pressurized gas which is subsequently passed through the turbine. Within this environment, the turbine is operated at the design values of flow function, stage pressure ratio, stage temperature ratio, and corrected speed. The first stage vane row and the first stage blade row are instrumented in both the spanwise and chordwise directions with pressure transducers and heat flux gages. The specific measurements to be taken include time averaged surface pressure and heat flux distributions on the vane and blade, flow passage static pressure, flow passage total pressure and total temperature distributions, and phase resolved surface pressure and heat flux on the blade.

Dunn, Michael G.↗

Periodic steamwise variations of heat transfer coefficients for incline and staggered arrays of circular jets with crossflow of spent air

Heat transfer characteristics were measured for inline and staggered arrays of circular jets impinging on a surface parallel to the jet orifice plate. The impinging flow was constrained to exit in a single direction along the channel formed by the jet plate and the heat transfer surface. In this configuration the air discharged from upstream transverse rows of jet holes imposes a crossflow of increasing magnitude on the succeeding downstream jet rows. Streamwise heat transfer coefficient profiles were determined for a streamwise resolution of one-third the streamwise hole spacing, utilizing a specially constructed test surface.

Florschuetz, L. W.↗

Compact Instruments Measure Helium-Leak Rates

Compact, lightweight instruments have been developed for measuring small flows of helium and/or detecting helium leaks in solenoid valves when the valves are nominally closed. These instruments do not impede the flows when the valves are nominally open. They can be integrated into newly fabricated valves or retrofitted to previously fabricated valves. Each instrument includes an upstream and a downstream thermistor separated by a heater, plus associated analog and digital heater-control, signal- conditioning, and data-processing circuits. The thermistors and heater are off-the-shelf surface mount components mounted on a circuit board in the flow path. The operation of the instrument is based on a well-established thermal mass-flow-measurement technique: Convection by the flow that one seeks to measure gives rise to transfer of heat from the heater to the downstream thermistor. The temperature difference measured by the thermistors is directly related to the rate of flow. The calibration curve from temperature gradient to helium flow is closely approximated via fifth-order polynomial. A microprocessor that is part of the electronic circuitry implements the calibration curve to compute the flow rate from the thermistor readings.

Stout, Stephen↗

Joule Thomson refrigerator

A bi-directional Joule Thomson refrigerator is described, which is of simple construction at the cold end of the refrigerator. Compressed gas flowing in either direction through the Joule Thomson expander valve and becoming liquid, is captured in a container in direct continuous contact with the heat load. The Joule Thomson valve is responsive to the temperature of the working fluid near the valve, to vary the flow resistance through the valve so as to maintain a generally constant flow mass between the time that the refrigerator is first turned on and the fluid is warm, and the time when the refrigerator is near its coldest temperature and the fluid is cold. The valve is operated by differences in thermal coefficients of expansion of materials to squeeze and release a small tube which acts as the expander valve.

Chung K Chan↗

The Effect of Air Bleed on the Heat Transfer and Pressure Distribution on 30 Conical Flares at a Mach Number of 6.8

The effect of a boundary-layer bleed at the start of a 30 deg half-angle flare upon the shape of the flow boundaries, the pressure distribution on the flare, and the heat transfer to the flare was studied at a Mach number of 6.8. The forebody was an ogive cylinder. Test Reynolds numbers, based on forebody length, ranged from 1 x 10(exp 6) to 7.4 x 10(exp 6). Schlieren photographs showed the effect produced upon the flow boundaries by varying the dimensions of the bleed in both the radial and axial directions and by blunting the lip at the leading edge of the flare. The heat transfer and pressure distribution on the flare were correlated with the shape and nature of the flow boundaries.

Crawford, Davis H.↗