Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “digitized waveform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

CCD data acquisition systems at Lick and Keck Observatories

This paper will describe and compare two distinct but related CCD data acquisition systems (DAS) currently under development at Lick and Keck Observatories. Although these two systems have a number of major architectural differences, they share a considerable amount of common hardware and software. Both of these new systems build on a large body of proven software that is the foundation of the existing CCD DAS currently in use at Lick Observatory. Both will provide support for reading up to four on-chip amplifiers per CCD and/or reading out mosaics of CCD chips. In addition, they will provide the capability for interactive, real-time adjustment of CCD waveforms for engineering purposes. Each of these two systems is composed of three major subsystems: (1) an instrument computer and its software; (2) a data capture computer and its software; and (3) a CCD/dewar controller and its software. The instrument computer is a Unix workstation, and the functions it provides include user interfaces, the interactive real-time display of CCD images, and the recording of image and FITS header data to disk and/or tape. The data capture computer is responsible for the packaging and high-speed transfer of the CCD pixel data stream into a bulk RAM, and the subsequent transfer of this data to the instrument computer. The CCD/dewar controller generates the waveforms for clocking the CCD, digitizes the pixel data, and transmits it via high-speed link to the data capture computer. It is also responsible for monitoring and controlling the dewar temperature and cryogen levels. Given the number of different types of processors and high-speed data links employed in both systems, a major emphasis of this paper will be on the various forms of interprocessor communications utilized for data transfer and distributed process synchronization.

Kibrick, R. I.↗

Simultaneous Red - Blue Lidar and Airborne Impactor Measurements

Simultaneous two-color (0.6943 micrometers and 0.3472 micrometers) LIDAR measurements were made in the troposphere and lower stratosphere over Boulder, Colorado during March 1973. In addition, on the evening of March 26, airborne single-stage impactor measurements were made at four altitudes-- 10,500, 25,000, 33,000 and 43,000 feet MSL. These data were integrated at constant altitude for 15,45, 45, and 60 minutes respectively. The LIDAR data were taken with Langley's 48" LIDAR using a dichroic beamsplitter to separate the return at 0.6943 micrometers and 0.3472 micrometers. The analog waveforms for both colors were digitized simultaneously; one on an NCAR data acquisition system and the other on the 48" Langley data acquisition system. A discussion of the preliminary results from these measurements will be presented.

McCormick, M. P.↗

Design and Implementation of a Deep Space Communications Complex Downlink Array

This paper describes the design and implementation of a frequency domain beamformer that will downlink array the signals of up to eight 34-m or 70-m antennas at each of NASA’s three Deep Space Communications Complexes (DSCC). The array digitizes inputs with an Intermediate Frequency (IF) of 100 to 600 MHz, coherently combines the inputs digitally, and transforms the combined waveform back to analog. Real-time correlation measurements are used for delay and phase calibration, allowing the system to adjust for atmospheric variations. A DSCC Downlink Array system is operational at each DSCC. Initial results from passes with the New Horizons spacecraft are presented and system performance is analyzed.

Wang, Douglas↗

Petahertz electronics

Petahertz, or lightwave, electronics uses tailored optical waveforms to control charge carriers in an electronic circuit at petahertz frequencies. This may enable faster processing than conventional pulsed electronics, which cannot be scaled beyond gigahertz frequencies. In recent years, petahertz-scale currents driven by optical fields have been measured in solid-state systems and nanoscale structures, with several proof-of-principle demonstrations of sub-optical-cycle current generation and optical-field-resolved waveform detection at the sub-femtosecond to few-femtosecond scale. Recent work has taken the first steps towards digital and quantum operation by exploring optical-field-driven logic and memory functionality. Here, in this Review, we discuss the progress towards sub-cycle field-driven current injection, highlighting key theoretical concepts, experimental milestones, and questions remaining as we push towards realizing petahertz electronics for ultrafast optical waveform analysis, digital logic, communications, and quantum computation.

Heide, Christian↗

High-speed, multi-channel detector readout electronics for fast radiation detectors

In this project, we are developing a high speed digital spectrometer that a) captures detector waveforms at rates up to 500 MSPS b) has upgraded event data acquisition with additional data buffers for zero dead time operation c) moves energy calculations to the FPGA to increase spectrometer throughput in fast scintillator applications d) uses a streamlined architecture and high speed data interface for even faster readout to the host PC These features are in addition to the standard functions in our existing spectrometers such as digitization, programmable trigger and energy filters, pileup inspection, data acquisition with energy and time stamps, MCA histograms, and run statistics. In Phase I, we upgraded one of our existing spectrometer designs to demonstrate the key principle of fast waveform capture using a 500 MSPS, 12 bit ADC and a Xilinx Virtex-4 FPGA. This upgraded spectrometer, named P500, performed well in initial tests of energy resolution, pulse shape analysis, and timing measurements, thus achieving item (a) above. In Phase II, we are revising the P500 to build a commercial prototype with the improvements listed in items (b)-(d). As described in the previous report, two devices were built to pursue this goal, named the Pixie-500 and the Pixie-500 Express. The Pixie-500 has only minor improvements from the Phase I prototype and is intended as an early commercial product (its production and part of its development were funded outside the SBIR). It also allows testing of the ADC performance in real applications.The Pixie-500 Express (or Pixie-500e) includes all of the improvements (b)-(d). At the end of Phase II of the project, we have tested and debugged the hardware, firmware and software of the Pixie-500 Express prototype boards delivered 12/3/2010. This proved substantially more complex than anticipated. At the time of writing, all hardware bugs have been fixed, the PCI Express interface is working, the SDRAM has been successfully tested and the SHARC DSP has been booted with preliminary code. All new ICs and circuitry on the prototype are working properly, however some of the planned firmware and software functions have not yet been completely implemented and debugged. Overall, due to the unanticipated complexity of the PCI Express interface, some aspects of the project could not be completed with the time and funds available in Phase II. These aspects will be completed in self-funded Phase III.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geoscience Laser Altimeter System (GLAS) for the ICESat Mission

The Geoscience Laser Altimeter System (GLAS) is a new generation lidar and is the primary science payload for NASA's ICESat Mission. The GLAS design combines a 10 cm precision surface lidar with a sensitive dual wavelength cloud and aerosol lidar. GLAS will precisely measure the heights of the Earth's polar ice sheets, establish a grid of accurate height profiles of the Earth's land topography, and profile the vertical distribution of clouds and aerosols on a global scale. GLAS will be integrated onto a small spacecraft built by Ball Aerospace, and will be launched into a polar orbit with a 590-630 km altitude at an inclination of 94 degrees. ICESat is is currently planned to launch in winter 2002/03 and GLAS is designed to operate continuously in space for a minimum of 3 years. GLAS will measure the vertical distance from orbit to the Earth's surface with pulses from a ND:YAG laser at a 40 Hz rate. Each 6 nsec wide 1064 nm laser pulse is used to produce a single range measurement. On the surface, the laser footprints have 66 m diameter and approx. 170 m center-center spacings. The GLAS receiver uses a I m diameter telescope to detect laser backscatter and a Si APD to detect the 1064 nm signals. The detector's output is sampled by a digital ranging receiver, which records each transmitted pulse and surface echo waveform with 1 nsec (15 cm) resolution. Each echo pulse is digitized and is reported to ground with a record length of from 200 to 544 samples, depending on the spacecraft's location . The GLAS location and epoch times are measured by a precision GPS receiver carried on the ICESat spacecraft. Initial processing of the echo waveforms within GLAS permits discrimination between cloud and surface echoes for selecting appropriate waveform samples. This selection is guided by an on-board DEM which is used to set the boundaries for the echo pulse search algorithm. Subsequent ground-based echo pulse analysis, along with GPS-based clock frequency estimates, permit final determination of the range to the surface, degree of pulse spreading, and vertical distribution of any vegetation illuminated by the laser. Accurate knowledge of the laser beam's pointing angle is needed to prevent height biases when measuring over tilted surfaces, such as near the boundaries of ice sheets. For surfaces with 2 deg. slopes, knowledge of pointing angle of the beam's centroid angle to better than 10 urad is needed. GLAS uses a stellar reference system (SRS) to measure the pointing angle of each laser firing relative to inertial space. The SRS uses a high precision star camera oriented toward local zenith and a gyroscope to determine the inertial orientation of the SRS optical bench. The far field pattern of each laser is measured pulse relative to the star camera with a laser reference system (LRS). GLAS will also measure the vertical distributions of clouds and aerosols by recording the vertical profiles of laser pulse backscatter at both 1064 and 532 nm. The 1064 rim measurements use the Si APD detector and will be used to measure the height and echo pulse shape from thicker clouds. The lidar receiver at 532 nm uses a narrow bandwidth etalon filter and highly sensitive photon counting detectors. The 532 nm backscatter profiles will be used to measure the vertical extent of thinner clouds and the atmospheric boundary layer. The GLAS instrument component development is complete and the instrument is undergoing final testing and qualification at NASA-Goddard. The GLAS "as-built" characteristics and its expected measurement performance will be discussed.

Abshire, James B.↗

Method of achieving ultra-wideband true-time-delay beam steering for active electronically scanned arrays

The various embodiments presented herein relate to beam steering an array antenna by modifying intermediate frequency (IF) waveforms prior to conversion to RF signals. For each channel, a direct digital synthesis (DDS) component can be utilized to generate a waveform or modify amplitude, timing and phase of a waveform relative to another waveform, whereby the generation/modification can be performed prior to the IF input port of a mixer on each channel. A local oscillator (LO) signal can be utilized to commonly drive each of the mixers. After conversion at the RF output port of each of the mixers, each RF signal can be transmitted by a respective antenna element in the antenna array. Initiation of transmission of each RF signal can be performed simultaneously at each antenna. The process can be reversed during receive whereby timing, amplitude, and phase of the received can be modified digitally post ADC conversion.

Loui, Hung↗

A minimax technique for time-domain design of preset digital equalizers using linear programming

A linear programming technique is presented for the design of a preset finite-impulse response (FIR) digital filter to equalize the intersymbol interference (ISI) present in a baseband channel with known impulse response. A minimax technique is used which minimizes the maximum absolute error between the actual received waveform and a specified raised-cosine waveform. Transversal and frequency-sampling FIR digital filters are compared as to the accuracy of the approximation, the resultant ISI and the transmitted energy required. The transversal designs typically have slightly better waveform accuracy for a given distortion; however, the frequency-sampling equalizer uses fewer multipliers and requires less transmitted energy. A restricted transversal design is shown to use the least number of multipliers at the cost of a significant increase in energy and loss of waveform accuracy at the receiver.

Vaughn, G. L.↗

Surface Change Detection Using Large Footprint Laser Altimetry

Laser altimeters provide a precise and accurate method for mapping topography at fine horizontal and vertical scales. A laser altimeter provides range by measuring the roundtrip flight time of a short pulse of laser light from the laser altimeter instrument to the target surface. The range is then combined with laser beam pointing knowledge and absolute position knowledge to provide an absolute measurement of the surface topography. Newer generations of laser altimeters measure the range by recording the shape and time of the outgoing and received laser pulses. The shape of the return pulse can also provide unique information about the vertical structure of material such as vegetation within each laser footprint. Distortion of the return pulse is caused by the time-distributed reflections adding together and representing the vertical distribution of surfaces within the footprint. Larger footprints (10 - 100m in diameter) can support numerous target surfaces and thus provide the potential for producing complex return pulses. Interpreting the return pulse from laser altimeters has evolved from simple timing between thresholds, range-walk corrections, constant-fraction discriminators, and multi-stop time interval units to actual recording of the time varying return pulse intensity - the return waveform. Interpreting the waveform can be as simple as digitally thresholding the return pulse, calculating a centroid, to fitting one or more gaussian pulse-shapes to the signal. What we present here is a new technique for using the raw recorded return pulse as a raw observation to detect centimeter-level vertical topographic change using large footprint airborne and spaceborne laser altimetry. We use the correlation of waveforms from coincident footprints as an indication of the similarity in structure of the waveforms from epoch to epoch, and assume that low correlation is an indicator of vertical structure or elevation change. Thus, using vertically and horizontally geolocated waveforms as raw observables (i.e., waveforms tied to a common reference ellipsoid), we assess whether epoch-to-epoch vertical ground motion results in a decrease in the correlation of coincident waveforms over time, and whether this can be used to quantify the magnitude of the deformation. Results of computer models and an example over an area of eroded beachfront will be presented.

Blair, J. Bryan↗

A multi-threshold sampling method for TOF PET signal processing

As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multithreshold sampling method to generate samples of a PET event waveform with respect to a few user-defined amplitudes. In this sampling scheme, one can extract both the energy and timing information for an event. In this paper, we report our prototype implementation of this sampling method and the performance results obtained with this prototype. The prototype consists of two multi-threshold discriminator boards and a time-to-digital converter (TDC) board. Each of the multi-threshold discriminator boards takes one input and provides up to 8 threshold levels, which can be defined by users, for sampling the input signal. The TDC board employs the CERN HPTDC chip that determines the digitized times of the leading and falling edges of the discriminator output pulses. We connect our prototype electronics to the outputs of two Hamamatsu R9800 photomultiplier tubes (PMTs) that are individually coupled to a 6.25 x 6.25 x 25mm{sup 3} LSO crystal. By analyzing waveform samples generated by using four thresholds, we obtain a coincidence timing resolution of about 340 ps and an {approx}18% energy resolution at 511 keV. We are also able to estimate the decay-time constant from the resulting samples and obtain a mean value of 44 ns with an {approx}9 ns FWHM. In comparison, using digitized waveforms obtained at a 20 GSps sampling rate for the same LSO/PMT modules we obtain {approx}300 ps coincidence timing resolution, {approx}14% energy resolution at 511 keV, and {approx}5 ns FWHM for the estimated decay-time constant. Details of the results on the timing and energy resolutions by using the multi-threshold method indicate that it is a promising approach for implementing digital PET data acquisition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anti-multipath digital signal detector

Detector operates in conjunction with radio frequency portion of receiver to detect digital signals transmitted in known modulation formats. Signal is constructed by assigning known and distinct modulation waveforms to sequence of message symbols. It reconstructs transmitted digital sequence with minimum probability that any reconstructed digit will be in error.

Painter, J. H.↗

Improved neutron-gamma discrimination for a 3 He neutron detector using subspace learning methods

3 He gas based neutron linear-position-sensitive detectors (LPSDs) have been applied for many neutron scattering instruments. Traditional Pulse-Height Analysis (PHA) for Neutron-Gamma Discrimination (NGD) resulted in the neutron-gamma efficiency ratio on the orders of 10 5 -10 6 . The NGD ratios of 3 He detectors need to be improved for even better scientific results from neutron scattering. Digital Signal Processing (DSP) analyses of waveforms were proposed for obtaining better NGD ratios, based on features extracted from rise-time, pulse amplitude, charge integration, a simplified Wiener filter, and the cross-correlation between individual and template waveforms of neutron and gamma events. Fisher linear discriminant analysis (FLDA) and three multivariate analyses (MVAs) of the features were performed. The NGD ratios are improved by about 10 2 -10 3 times compared with the traditional PHA method. Finally, our results indicate the NGD capabilities of 3 He tube detectors can be significantly improved with subspace-learning based methods, which may result in a reduced data-collection time and better data quality for further data reduction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast spark-detection system for GEM detectors

The sPHENIX experiment is currently under commissioning at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab (BNL). The Time Projection Chamber (TPC) serves as a tracking detector for the experiment. The sPHENIX TPC uses a stack of four Gas Electron Multipliers (GEMs) as a gain stage in a reduced ion back-flow configuration. To mitigate the damaging effects of sparks in the GEMs, an online spark monitoring system was created. Once the system detects a spark in a GEM stack, the voltages across the GEMs in that stack can be lowered to prevent further sparking without affecting the gain and efficiency of the other modules. Spark signals are coupled out of the GEM stack by a pick-off capacitor attached to the bottom of the bottom GEM. Custom PCBs convert the oscillatory spark signal into a mono-polar pulse that is then digitized. The software then saves the waveform in a server and uses experimentally derived thresholds to determine how to react. As a result, the system has so far proven to be effective at improving the stability of the TPC and preventing damaging events while collecting cosmic ray data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A frequency and amplitude scanned quadrupole mass filter for the analysis of high m/z ions

Quadrupole mass filters (QMFs) are usually not used to analyze high m/z ions, due to the low frequency resonant circuit that is required to drive them. Here we describe a new approach to generating waveforms for QMFs. Instead of scanning the amplitude of a sine wave to measure the m/z spectrum, the frequency of a trapezoidal wave is digitally scanned. A synchronous, narrow-range (<0.2%) amplitude scan overlays the frequency scan to improve the sampling resolution. Because the frequency is the primary quantity that is scanned, there is, in principle, no upper m/z limit. The frequency signal is constructed from a stabilized base clock using a field programmable gate array. This signal drives integrating amplifiers which generate the trapezoidal waves. For a trapezoidal wave the harmonics can be minimized by selecting the appropriate rise and fall times. To achieve a high resolving power, the digital signal has low jitter, and the trapezoidal waveform is generated with high fidelity. The QMF was characterized with cesium iodide clusters. Singly and multiply charged clusters with z up to +5 were observed. A resolving power of ∼1200 (FWHM) was demonstrated over a broad m/z range. Resolution was lost above 20 000 Th, partly because of congestion due to overlapping multiply charged clusters. Ions were observed for m/z values well in excess of 150 000 Th.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital input is buffered to real-time analog display

Buffering technique utilizes nine-bit binary counter and holding register of eight flip-flops. These flip-flops form the memory device that allows precise asynchronous conversion of the digital source data. Counter generates a waveform which is passed through a low pass filter to recover data in analog form.

Bower, K. F.↗

Engineering studies related to Skylab program

The relationship between the S-193 Automatic Gain Control data and the magnitude of received signal power was studied in order to characterize performance parameters for Skylab equipment. The r-factor was used for the assessment and is defined to be less than unity, and a function of off-nadir angle, ocean surface roughness, and receiver signal to noise ratio. A digital computer simulation was also used to assess to additive receiver, or white noise. The system model for the digital simulation is described, along with intermediate frequency and video impulse response functions used, details of the input waveforms, and results to date. Specific discussion of the digital computer programs used is also provided.

Hayne, G. S.↗

Experimental investigation of aeronautical and maritime communications and surveillance using satellites

The experimental program described included an evaluation of every significant factor affecting the accuracy of position fixing by range measurements from geostationary satellites. The tone-code ranging technique was found to provide a precision of roughly 0.1 n mi at mid-lattitudes with one range measurement at L-band and one at VHF. The factors which introduce bias errors were studied analytically and experimentally, and means of rectifying the bias errors were developed. An operational system at L-band may be expected to provide position fix accuracy of 0.1 n mi over large regions of the earth. The ranging technique developed within this program is digital, and uses a single signalling waveform and a single modem for communications and ranging.

Anderson, R. E.↗