Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

NSC 800, 8-bit CMOS microprocessor

The NSC 800 is an 8-bit CMOS microprocessor manufactured by National Semiconductor Corp., Santa Clara, California. The 8-bit microprocessor chip with 40-pad pin-terminals has eight address buffers (A8-A15), eight data address -- I/O buffers (AD(sub 0)-AD(sub 7)), six interrupt controls and sixteen timing controls with a chip clock generator and an 8-bit dynamic RAM refresh circuit. The 22 internal registers have the capability of addressing 64K bytes of memory and 256 I/O devices. The chip is fabricated on N-type (100) silicon using self-aligned polysilicon gates and local oxidation process technology. The chip interconnect consists of four levels: Aluminum, Polysi 2, Polysi 1, and P(+) and N(+) diffusions. The four levels, except for contact interface, are isolated by interlevel oxide. The chip is packaged in a 40-pin dual-in-line (DIP), side brazed, hermetically sealed, ceramic package with a metal lid. The operating voltage for the device is 5 V. It is available in three operating temperature ranges: 0 to +70 C, -40 to +85 C, and -55 to +125 C. Two devices were submitted for product evaluation by F. Stott, MTS, JPL Microprocessor Specialist. The devices were pencil-marked and photographed for identification.

Suszko, S. F.↗

Radiation-Resistant Photon-Counting Detector Package Providing Sub-ps Stability for Laser Time Transfer in Space

We are reporting on a design, construction and performance of photon-counting detector packages based on silicon avalanche photodiodes. These photon-counting devices have been optimized for extremely high stability of their detection delay. The detectors have been designed for future applications in fundamental metrology and optical time transfer in space. The detectors have been qualified for operation in space missions. The exceptional radiation tolerance of the detection chip itself and of all critical components of a detector package has been verified in a series of experiments.

radiation hardness↗

Quad-Port Transceivers For A Dual-CRR LAN

Quad-port fiber-optic transceivers demonstrated successfully as physical-layer interface units in WhisperNet - local-area network (LAN) of computers and other devices in communication with each other. Each node of Dual-CRR LAN contains quad-port transceiver serving four pairs of optical fibers. Quad-port transceiver consists of two dual-port transceivers and ancillary equipment in compact package. Transceiver serves as interface between optical fibers and external computing devices. Because of high reliability, availability and "fail-soft" nature, network well suited to military and critical commercial applications.

Wiencko, Joseph A., Jr.↗

Packaging Technologies for 500 C SiC Electronics and Sensors: Challenges in Material Science and Technology

This paper presents ceramic substrates and thick-film metallization based packaging technologies in development for 500C silicon carbide (SiC) electronics and sensors. Prototype high temperature ceramic chip-level packages and printed circuit boards (PCBs) based on ceramic substrates of aluminum oxide (Al2O3) and aluminum nitride (AlN) have been designed and fabricated. These ceramic substrate-based chip-level packages with gold (Au) thick-film metallization have been electrically characterized at temperatures up to 550C. The 96 alumina packaging system composed of chip-level packages and PCBs has been successfully tested with high temperature SiC discrete transistor devices at 500C for over 10,000 hours. In addition to tests in a laboratory environment, a SiC junction field-effect-transistor (JFET) with a packaging system composed of a 96 alumina chip-level package and an alumina printed circuit board was tested on low earth orbit for eighteen months via a NASA International Space Station experiment. In addition to packaging systems for electronics, a spark-plug type sensor package based on this high temperature interconnection system for high temperature SiC capacitive pressure sensors was also developed and tested. In order to further significantly improve the performance of packaging system for higher packaging density, higher operation frequency, power rating, and even higher temperatures, some fundamental material challenges must be addressed. This presentation will discuss previous development and some of the challenges in material science (technology) to improve high temperature dielectrics for packaging applications.

dielectric properties↗

Phase Calibration of Microphones by Measurement in the Free-field

Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.

Shams, Qamar A.↗

Fluid Dynamics of Small, Rugged Vacuum Pumps of Viscous-Drag Type

The need to identify spikes in the concentration of hazardous gases during countdowns to space shuttle launches has led Kennedy Space Center to acquire considerable expertise in the design, construction, and operation of special-purpose gas analyzers of mass-spectrometer type. If such devices could be miniaturized so as to fit in a small airborne package or backpack them their potential applications would include integrated vehicle health monitoring in later-generation space shuttles and in hazardous material detection in airports, to name two examples. The bulkiest components of such devices are vacuum pumps, particularly those that function in the low vacuum range. Now some pumps that operate in the high vacuum range (e.g. molecular-drag and turbomolecular pumps) are already small and rugged. The present work aims to determine whether, on physical grounds, one may or may not adopt the molecular-drag principle to the low-vacuum range (in which case viscous-drag principle is the appropriate term). The deliverable of the present effort is the derivation and justification of some key formulas and calculation methods for the preliminary design of a single-spool, spiral-channel viscous-drag pump.

Russell, John M.↗

Deep Space 1: Testing New Technologies for Future Small Bodies Missions

Launched on October 24, 1998, Deep Space 1 (DS1) was the first mission of NASA's New Millennium Program, chartered to validate in space high-risk, new technologies important for future space science programs. The advanced technology payload that was tested on DS1 comprises solar electric propulsion, solar concentrator arrays, autonomous on-board navigation and other autonomous systems, several telecommunications and microelectronics devices, and two low-mass integrated science instrument packages. The mission met or exceeded all of its success criteria. The 12 technologies were rigorously exercised so that subsequent flight projects would not have to incur the cost and risk of being the fist users of these new capabilities. Examples of the benefits to future small body missions from DS1's technologies will be described.

Deep Space 1 (DS1)↗

A Study of Shape Memory Polymer Based Slat-Cove Filler

Aircraft noise reduction is an application of current intense interest for which smart materials show significant potential. Specifically, the aeroacoustic noise produced by the unsteady aerodynamic flow about the leading-edge high-lift device, such as leading-edge slat, of typical transport-aircraft wings is of particular interest. Concepts with the most promise to mitigate this noise source, most notably the slat-cove filler concept, have focused on highly reconfigurable structures that change shape between different phases of the flight envelope. These shape changes often involve large deformation, which has stimulated the consideration of shape memory materials. In recent years, shape memory materials (SMMs) have drawn greater interest for applications such as smart fabrics, intelligent medical devices, self-deployable space structures, morphing structures and packaging. Compared to other shape memory materials, like shape memory alloys (SMAs) or shape memory ceramics (SMCs), shape memory polymers (SMPs) have desirable advantages such as high elastic deformation to enable large shape change, broad tailorability of mechanical properties, potential biocompatibility and biodegradability, ductility, light weight and ease of processing. However, SMPs still have some critical disadvantages such as insufficient mechanical and thermal characteristics for structural applications, low recovery stress, and long response time. The new LaRC shape memory thermosetting polymer composite (LaRC-SMPC) discussed herein was synthesized with nontoxic monomers and conductive/magnetic fillers to yield enhanced thermal/mechanical characteristics and faster response times. LaRC-SMPCs with a variety of fiber reinforcements [Kevlar®, carbon fiber (standard and thin-ply), and carbon-nanotube (CNT) sheet] were fabricated to tailor the physical properties and test for suitability as a slat-cove filler (SCF). The performance of SCF prototypes fabricated with the developed LaRC-SMPCs was evaluated using a bench-top test apparatus. The SCFs made of Kevlar® fiber fabric or carbon fiber fabric infused shape memory polymer composite (SMPC) exhibited kinking during simulated deployment and stowage, which can be problematic during operation. The SCF made of CNT sheet/SMP composite did not exhibit kinking, but the deployment was sluggish compared to carbon fiber fabric/SMP composite. This report documents the evolution of designing SMPCs as slat-cove fillers for aircraft noise reduction. In the course of the investigation, several 2 approaches were investigated to address shortcomings in material characteristics based on performance requirements of operational slat-cove fillers.

Kang, Jin Ho↗

NEPP non-volatile memory : FY09 summary report

This report documents the activities and results of the fiscal year 2009 (FY09) funding for the NASA Electronic Parts and Packaging (NEPP) program for non-volatile memory (NVM) devices. The FY09 task was divided into two main efforts: 1. Development of in-house measurement capability for flash devices 2. Reliability characterization of multi-level vs. single-level flash devices The FY09 NEPP Non Volatile Memory study was organized into these two sections in recognition of the continued and increasing importance of NVM to NASA. All NASA missions use NVM for boot code storage and some limited data archiving. Space-grade NVM has lagged commercial NVM development by many orders of magnitude, however. This gap in density only continues to increase as space-grade memories remain constant in the 1–16 Mbit levels, while commercial flash-based devices shrink in size and double in capacity every 18 months. Commercial flash devices are now at the 32 Gbit level, 10,000 times denser than current NASA NVM. This FY marks the beginning of a significant technological transition in NVM for NASA. The aggressive scaling of commercial NVMs has, as a by-product, made some of the flash devices radiation-tolerant enough to be at least considered for low-level radiation environment missions [Irom 2008]. This NEPP task is focused on understanding the reliability and potential future applications of such highly scaled flash memories.

Heidecker, Jason↗

High Precision Piezoelectric Linear Motors for Operations at Cryogenic Temperatures and Vacuum

The Jet Propulsion Laboratory evaluated the use of an electromechanical device for optically positioning a mirror system during the pre-project phase of the Pluto-Fast-Flyby (PFF) mission. The device under consideration was a piezoelectric driven linear motor functionally dependent upon a time varying electric field which induces displacements ranging from submicrons to millimeters with positioning accuracy within nanometers. Using a control package, the mirror system provides image motion compensation and mosaicking capabilities. While this device offers unique advantages, there were concerns pertaining to its operational capabilities for the PFF mission. The issues include irradiation effects and thermal concerns. A literature study indicated that irradiation effects will not significantly impact the linear motor's operational characteristics. On the other hand, thermal concerns necessitated an in depth study.

piezoelectric motors↗

Nimbus D RMP program

The development of an advanced long life rate measuring package, designed for a five year useful life as a meteorological satellite control sensor is discussed. The primary function of the rate mesuring package is to provide rate information for the reaction wheel and gas jet torquing devices that are used to damp spacecraft oscillations and to constrain the spacecraft to the required attitude with respect to the orbital plane. The specifications for the rate measuring package sensor are described. Application of the rate measuring package to the Nimbus D satellite is proposed.

Source record↗

The Rocketdyne Multifunction Tester. Part 1: Test Method

The Rocketdyne Multifunction Tester is a general purpose test apparatus which utilizes axial and radial magnetic bearings as shaft excitation devices. The tester is modular in design so that different seal and bearing packages can be tested on the same test stand. The tester will be used for rotordynamic coefficient extraction, as well as life and fluid/material compatibility evaluations. Use of a magnetic bearing as a shaft excitation device opens up many possibilities for shaft excitation and rotordynamic coefficient extraction. In addition to describing the basic apparatus, some of the excitation and extraction methods are described. Some of the excitation methods to be discussed include random, aperiodic, harmonic, impulse and chirp.

Murphy, Brian T.↗

A new RF package suitable for aeronautical commercial and DSCS satellite applications

Higher levels of integration through the use of GaAs and silicon MMIC devices, a die-cast housing, and the reduction of the number of subassemblies has enabled a large reduction of the size and weight of the electronics package for commercial and military satellite communications. This paper presents an electronics architecture and hardware that utilizes many new integrated circuits and design techniques, and allows flexibility for future satellite frequency changes and expansion. Key features of the radio are extended C-band, InSat, Defense Satellite Communications System (DSCS), and Ku-band coverage options; 70 (or 140) MHz transponder bandwidth or L-band block bandwidth IFs; integrated RS-232 control through local handheld terminal or remote computer; remote control of crystal reference oscillator for aging and temperature compensation; integrated 2 or 5 watt solid-state power amplifiers (SSPA); optional integrated solid-state booster amplifiers to 40 watts; optional external amplifiers to 100 watts; integral beacon tracking with second integrated downcoverter for antenna positioning; radio, including low-noise block converter (LNB) and SSPA, weighs 8.5 kg and measures 32 x 23 x 16.5 cm; environmentally ruggedized for -40 to +60 C; O-ring sealed for waterproofing; passive (convection) cooling; and simple cabling and installation, with a single cable between radio and LNB, and two cables between radio and IF interface. The small size and light weight of the radio make it ideal for mounting on stabilized antenna platforms (gyroscopic or servo). Several input power options (110 or 220 VAC; +48, +12, or -24 VDC) facilitate operation on multiple platforms.

Hamilton, Robert J., Jr.↗

High temperature superconductivity space experiment (HTSSE)

An experiment dealing with high-temperature superconducting devices and components in space is discussed. A variety of devices (primarily passive microwave and millimeter-wave components) has been procured and will be integrated with a cryogenic refrigerating and data acquisition system to form the space package, which will be launched in late 1992. This space experiment is expected to demonstrate that this technology is sufficiently robust to survive the space environment and that the technology has the potential to improve the operation of space systems significantly. The devices for the initial launch have been evaluated electrically, thermally, and mechanically, and will be integrated into the final space package early in 1991. The performance of the devices is summarized, and some potential applications of this technology in space systems are outlined.

Ritter, J. C.↗

Test equipment data package for the KC-135 fiber pulling apparatus

The Fiber Pulling Apparatus (FPA) is a device designed to produce continuous glass fibers from simulated lunar soil, and to determine the effects of reduced gravity, specifically 1/6 g on fiber formation and resultant properties. Briefly, pre-melt simulated lunar soil will be placed in a pint crucible and heated to 1200 C or higher, up to a maximum temperature of 1400 C. At a given temperature, a quartz fiber will be immersed into the melt and then pulled through a chill block and wound onto a cylindrical bobbin using a servo motor control. A high resolution video camera will record the fiber as it is being pulled. This assembly wil be enclosed in Plexiglas. Before fiber pulling commences, the apparatus will be backfilled with dry nitrogen. A separate data acquisition system will support this apparatus. This system will contain a personal computer, video recorder, and monitor. Temperature, acceleration, winding speed, and video images will be controlled and recorded using the data acquisition system. Thus, the FPA will consist of two hardware packages, the fiber production assembly and the data acquisition rack. The primary objective of this test is to determine the effects of 1/6 g on the formation of continuous glass fiber made from simulated lunar soil. Baseline studies using the FPA on the ground will provide a reference for the 1/6 g studies. Of particular interest will be the effect of 1/6 g on the free fluid zone where the fiber exits the crucible. In the fiber spinning parlance this zone is known as the upper jet region, where the boundary slope is greater than one tenth. The properties of the resulting glass fiber will depend on the jet shape as well as distributions of velocity, temperature and tension within the jet. It is unknown at this time how 1/6 g will effect these parameters.

Kosten, Sue↗

Adaptive Mesh Refinement for Microelectronic Device Design

Finite element and finite volume methods are used in a variety of design simulations when it is necessary to compute fields throughout regions that contain varying materials or geometry. Convergence of the simulation can be assessed by uniformly increasing the mesh density until an observable quantity stabilizes. Depending on the electrical size of the problem, uniform refinement of the mesh may be computationally infeasible due to memory limitations. Similarly, depending on the geometric complexity of the object being modeled, uniform refinement can be inefficient since regions that do not need refinement add to the computational expense. In either case, convergence to the correct (measured) solution is not guaranteed. Adaptive mesh refinement methods attempt to selectively refine the region of the mesh that is estimated to contain proportionally higher solution errors. The refinement may be obtained by decreasing the element size (h-refinement), by increasing the order of the element (p-refinement) or by a combination of the two (h-p refinement). A successful adaptive strategy refines the mesh to produce an accurate solution measured against the correct fields without undue computational expense. This is accomplished by the use of a) reliable a posteriori error estimates, b) hierarchal elements, and c) automatic adaptive mesh generation. Adaptive methods are also useful when problems with multi-scale field variations are encountered. These occur in active electronic devices that have thin doped layers and also when mixed physics is used in the calculation. The mesh needs to be fine at and near the thin layer to capture rapid field or charge variations, but can coarsen away from these layers where field variations smoothen and charge densities are uniform. This poster will present an adaptive mesh refinement package that runs on parallel computers and is applied to specific microelectronic device simulations. Passive sensors that operate in the infrared portion of the spectrum as well as active device simulations that model charge transport and Maxwell's equations will be presented.

Cwik, Tom↗

The Apollo X-ray fluorescence spectrometer

The Apollo X-ray fluorescence spectrometer was a part of a geochemical package flown on the Apollo 15 and 16 missions. The device was to map the concentrations of aluminum, magnesium, and silicon in the lunar regolith along the spacecraft ground track. A functional description of the spectrometer is given and the telemetry data format is discussed together with the pulse height analyzer, the pulse shape discriminator, questions of in-flight calibration, and the flight results.

Jagoda, N.↗