Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Diagnosis of Factors Impacting Yield in Multilayer Devices for Superconducting Electronics

The ability to localize defects in order to understand failure mechanisms in complex superconducting electronics circuits, while operating at low temperature, does not yet exist. Here, this work applies thermally-induced voltage alteration (TIVA), to a biased superconducting electronics (SCE) circuit at ambient temperature. TIVA is a commonly used, laser-based failure analysis technique developed for silicon-based microelectronics. The non-operational circuit consisted of an arithmetic logic unit (ALU) in a high-frequency test bed designed at HYPRES and fabricated by MIT Lincoln Laboratory using their SFQ5ee process. Localized TIVA signals were correlated with reflected light images at the surface, and these sites were further investigated by scanning electron microscopy imaging of focused ion-beam cross-sections. The areas investigated, where prominent TIVA signals were observed, showed seams in the Nb wiring layers at contacts to Josephson junctions or inductors and/or disrupted junction morphologies. Finally, these results suggest that the TIVA technique can be used at ambient temperature to diagnose fabrication defects that may cause low temperature circuit failure.

36 MATERIALS SCIENCE↗

ITAR: A modified TAR method to determine depth dose distribution for an ophthalmic device that performs kilovoltage x-ray pencil-beam stereotaxy

Purpose: New technology has been developed to treat age-related macular degeneration (AMD) using 100 kVp pencil-beams that enter the patient through the radio-resistant sclera with a depth of interest between 1.6 and 2.6 cm. Measurement of reference and relative dose in a kilovoltage x-ray beam with a 0.42 cm diameter field size and a 15 cm source to axis distance (SAD) is a challenge that is not fully addressed in current guidelines to medical physicists. AAPM's TG-61 gives dosimetry recommendations for low and medium energy x-rays, but not all of them are feasible to follow for this modality. Methods: An investigation was conducted to select appropriate equipment for the application. PTW's Type 34013 Soft X-Ray Chamber (Freiburg, Germany) and CIRS's Plastic Water LR (Norfolk, VA) were found to be the best available options. Attenuation curves were measured with minimal scatter contribution and thus called Low Scatter Tissue Air Ratio (LSTAR). A scatter conversion coefficient (C{sub scat}) was derived through Monte Carlo radiation transport simulation using MCNPX (LANL, Los Alamos, NM) to quantify the difference between a traditional TAR curve and the LSTAR curve. A material conversion coefficient (C{sub mat}) was determined through experimentation to evaluate the difference in attenuation properties between water and Plastic Water LR. Validity of performing direct dosimetry measurements with a source to detector distance other than the treatment distance, and therefore a different field size due to a fixed collimator, was explored. A method—Integrated Tissue Air Ratio (ITAR)—has been developed that isolates each of the three main radiological effects (distance from source, attenuation, and scatter) during measurement, and integrates them to determine the dose rate to the macula during treatment. Results: LSTAR curves were determined to be field size independent within the range explored, indicating that direct dosimetry measurements may be performed with a source to detector distance of 20 cm even though the SAD is 15 cm during treatment. C{sub scat} varied from 1.102 to 1.106 within the range of depths of interest. The experimental variance among repeated measurements of C{sub mat} was larger than depth dependence, so C{sub mat} was estimated as1.019 for all depths of interest. Conclusions: Equipment selection, measurement techniques, and formalism for the determination of dose rate to the macula during stereotaxy for AMD have been determined and are strongly recommended by the authors of this paper to be used by clinical medical physicists.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Future of Electronic Device Design: Device and Process Simulation Find Intelligence on the World Wide Web

We are on the path to meet the major challenges ahead for TCAD (technology computer aided design). The emerging computational grid will ultimately solve the challenge of limited computational power. The Modular TCAD Framework will solve the TCAD software challenge once TCAD software developers realize that there is no other way to meet industry's needs. The modular TCAD framework (MTF) also provides the ideal platform for solving the TCAD model challenge by rapid implementation of models in a partial differential solver.

Biegel, Bryan A.↗

Overview of the Exploration Exercise Device Validation Study Plans

The NASA has determined that a multi-functional exercise device will be developed for use as an exercise device during exploration missions. The device will allow for full body resistance and metabolic exercise necessary to minimize physiological losses during space flight and to maintain fitness necessary to perform critical mission tasks. Prior to implementation as an exercise device on an Exploration vehicle, there will be verification and validation testing completed to determine device efficacy at providing the necessary training stimuli to achieve desired goals. Because the exploration device will be new device that has yet be specified, specific Verification and Validation (V&V) protocols have yet to be developed. Upon delivery of an exploration exercise device training unit, stakeholders throughout NASA will develop V&V plans that include ground-based testing and testing on the International Space Station (ISS). Stakeholders will develop test protocols that include success criterion for the device. Ground tests will occur at NASA Johnson Space Station prior to flight testing. The intents of the ground tests are to allow crew, spaceflight medicine, science, engineering, Astronaut Strength, Conditioning, and Reconditioning staff, and others to gain experience in the best utilization of the device. The goal is to obtain an evidence base for recommending use of the device on the ISS. The developed protocol will be created to achieve multiple objectives, including determining if the device provides an adequate training stimulus for 5th - 95th percentile males and females, allows for exercise modalities that protect functional capability, and is robust and can withstand extensive human use. Although protocols are yet to be determined, current expectations include use of the device by test subjects and current crew in order to obtain quantitative and qualitative feedback. Information obtained during the ground tests may be used to influence device modifications during design iterations. Assuming successful ground tests, the device will be installed on the ISS for testing during space flight. Spaceflight testing is envisioned to include an activation and checkout (ACO) phase and a V&V phase. During the ACO phase, 1-2 crewmembers will exercise with the device to ensure proper function. ACO is expected to last multiple months because of the many modes and methods of exercise that need to be assessed. However, the goal is to complete the ACO as quickly as possible. Once successful ACO occurs, the crew will be free to use the device for normal exercise pending concurrence from stakeholders. V&V tests on the ISS will ideally consist of crew using the device for all of their exercise for an entire mission. Exercise prescriptions will be supplied that replicate expected prescriptions during exploration missions. Crew that are not enrolled in the V&V studies would be also free to use the device as their schedule permits. As experience is gained by users, exercise protocols could change. The intent of all V&V testing is to ensure that all have thorough understanding of experience at optimizing device capability

DeWitt, J. K.↗