Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Measurements of speed of response of high-speed visible and IR optical detectors

A technique for measuring speed of response of high speed visible and IR optical detectors to mode-locked Nd:YAG laser pulses is described. Results of measurements of response times of four detectors are presented. Three detectors that can be used as receivers in a 500-MHz optical communication system are tested.

Rowe, H. E.↗

Micromachined Thermoelectric Sensors and Arrays and Process for Producing

Linear arrays with up to 63 micromachined thermopile infrared detectors on silicon substrates have been constructed and tested. Each detector consists of a suspended silicon nitride membrane with 11 thermocouples of sputtered Bi-Te and Bi-Sb-Te thermoelectric elements films. At room temperature and under vacuum these detectors exhibit response times of 99 ms, zero frequency D* values of 1.4 x 10(exp 9) cmHz(exp 1/2)/W and responsivity values of 1100 V/W when viewing a 1000 K blackbody source. The only measured source of noise above 20 mHz is Johnson noise from the detector resistance. These results represent the best performance reported to date for an array of thermopile detectors. The arrays are well suited for uncooled dispersive point spectrometers. In another embodiment, also with Bi-Te and Bi-Sb-Te thermoelectric materials on micromachined silicon nitride membranes, detector arrays have been produced with D* values as high as 2.2 x 10(exp 9) cm Hz(exp 1/2)/W for 83 ms response times.

Foote, Marc C.↗

Ultraviolet and extreme ultraviolet response of charge-coupled-device detectors

Results of a program to enhance the ultraviolet and extreme ultraviolet response of charge-coupled devices are presented. The ultimate goal of the program is to develop a large format device with both high and stable quantum efficiency from 100 to 3000 A that can be used as a windowless imaging detector in a space environment. Ultraviolet quantum efficiency measurements have been made for several ion-implanted and laser-annealed test CCDs. Quantum efficiencies as high as 22 percent at 2500 A, where the absorption depth in silicon is about 55 A, have been observed in one such test CCD. Quantum efficiency measurements of standard back-illuminated CCDs are also presented.

Stern, R. A.↗

A large area multi-element telescope for measuring the cosmic ray isotope composition

To measure the isotopic composition of cosmic rays up to Fe an instrument is needed with good isotopic resolution and a large exposure. The large geometry needed for a balloon-borne detector has been obtained with large mapped detectors and a trajectory determining spark chamber. The instrument achieves isotopic resolution only for stopping particles. For low charge particles where there is no Cerenkov response the detector works as a multiple dE/dx-Range-Energy detector. For higher charges where scintillator saturation becomes important it becomes a Cerenkov-range measurement.

Fisher, A. J.↗

Dynamic-Range Compression For Infrared Imagery

Photorefractive crystals covering detectors prevent saturation. To make full use of information in image, desirable to compress dynamic range of input intensity to within region of approximately linear response of detector. Dynamic-range compression exhibited by measurements of attenuation in photorefractive GaAs. Effective dynamic-range-compressor plate, film, or coating reduces apparent contrast of scene imaged on detector plane to within dynamic range of detectors; original image contrast or intensity data recovered subsequently in electronic image processing because range-compression function and inverse known.

Cheng, Li-Jen↗

Performance of high resolution decoding with Multi-Anode Microchannel Array detectors

The Multi-Anode Microchannel Array (MAMA) is a microchannel plate based photon counting detector with applications in ground-based and space-based astronomy. The detector electronics decode the position of each photon event, and the decoding algorithm that associates a given event with the appropriate pixel is determined by the geometry of the anode array. The standard MAMA detector has a spatial resolution set by the anode array of 25 microns, but the MCP pore resolution exceeds this. The performance of a new algorithm that halves the pixel spacing and improves the pixel spatial resolution is described. The new algorithm does not degrade the pulse-pair resolution of the detector and does not require any modifications to the detector tube. Measurements of the detector's response demonstrate that high resolution decoding yields a 60 percent enhancement in spatial resolution. Measurements of the performance of the high resolution algorithm with a 14 micron MAMA detector are also described. The parameters that control high resolution performance are discussed. Results of the application of high resolution decoding to speckle interferometry are presented.

Kasle, David B.↗

Broad band X-ray astronomical spectroscopy

The Broad Band X-Ray Telescope (BBXRT) experiment has been designed for high sensitivity, moderate resolution spectrophotometry of cosmic sources in the range 0.5 to 12 keV. Principal elements are two co-aligned imaging telescopes with cooled Si(Li) detectors at each focus. The mirror design uses an approximate geometry of tightly nested, conical, foil reflectors that allow a large filling factor (high throughput) at small grazing angles (high energy response). Each detector consists of a cluster of five elements defined with grooves on a single crystal. This arrangement affords some spatial resolution as well as a means of substantial background reduction. Shuttle borne measurements will typically be of 2000 s duration for sources with a flux of 10 to the -12 erg/sq cm-s.

Serlemitsos, P. J.↗

Test results from a comparative evaluation of a condensation nuclei fire detector

The fire/smoke alarm response of a condensation nuclei fire detector (CNFD) was compared with photoelectric and ionization detectors. Tests were conducted in a former control room 8.5 m by 8.9 with a 2.7 m ceiling. The room had air supplied from above the ceiling and under the floor with return air exiting from ceiling grills. The environment was varied from 278 to 305 K and relative humidities from 8 to 65%. Four detection zones were located in the room. Each zone contained a sampling head for the CNDF, a photodetector, and an ionization detector so that each detector system had four opportunities to alarm during tests. The particle level in the test room was also monitored during tests with a condensation nuclei particle counter. The CNFD responded to 90% of exposures to smoldering plastic and 84% of exposures to visible fire. The photoelectric response was 43 and 12.5% respectively for the same conditions. The ionization response was 9 and 48 respectively.

Bricker, R. W.↗

MODIS Detector Differences Using Deep Convective Clouds and Desert Targets

An accurate on-orbit characterization of the Moderate Resolution Imaging Spectroradiometer (MODIS) sensors onboard the Terra and Aqua satellites is essential to satisfy the requirements from the scientific community for high-quality operational and research products. In this study, NASA’s C6.1 L1B data are utilized to assess the stability of the calibrated top of atmosphere reflectance retrieved from individual detectors within a spectral band over deep convective clouds (DCCs) and desert sites. The results from these invariant Earth targets show detector-to-detector (D2D) differences in the L1B reflectance products for select MODIS reflective solar bands. For Aqua MODIS, the D2D differences have no significant change over time for the bands studied. However, the D2D differences exhibit an increase in magnitude over time for Terra MODIS bands 1, 3-7, and 26, which can induce noticeable striping and higher uncertainties in the downstream data products. The D2D stability assessment results over DCCs are consistent with those observed over desert sites. In addition, the view-angle dependence of the D2D differences is investigated by separating the frames along scan into five zones. The D2D assessment is performed for each of the five zones, and the results will further benefit any improvements in the calibration of a detector-dependent response versus scan angle that can be considered for future MODIS Level 1B Collections.

MODIS↗

The response of a 0.03-cm silicon detector to a mixed neutron and gamma field as a function of shield material and thickness

The neutron and gamma radiation from a MHW-RTG was used to evaluate the total response of a shielded 0.3-mm silicon detector. The generator employs a 2200 W(th) PuO2 heat source concept known as the HELIPAK. The total integrated neutron and gamma ray fluxes at 100 cm away from the source along the radial direction were 1.67 x 1,000 n/sq cm/s and 1.49 x 10,000 gamma sq cm/s, respectively. Experimental values of the response function of the shielded silicon detector were used to determine the total counting rates due to photons at bias energies ranging from 50 to 200 keV. For neutrons, analytically computed response functions were used to determine the total counting rates at the same bias energies. It was found that for an aluminum shield the neutrons are not significant, regardless of the thickness of the shield. However, the magnitude of the total counting rate due to neutrons increases with increased atomic number of the shield and becomes comparable to the counting rate due to photons for a platinum shield thickness of 5 cm.

Taherzadeh, M.↗

NPP VIIRS Geometric Performance Status

Visible Infrared Imager Radiometer Suite (VIIRS) instrument on-board the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP) satellite is scheduled for launch in October, 2011. It is to provide satellite measured radiance/reflectance data for both weather and climate applications. Along with radiometric calibration, geometric characterization and calibration of Sensor Data Records (SDRs) are crucial to the VIIRS Environmental Data Record (EDR) algorithms and products which are used in numerical weather prediction (NWP). The instrument geometric performance includes: 1) sensor (detector) spatial response, parameterized by the dynamic field of view (DFOV) in the scan direction and instantaneous FOV (IFOV) in the track direction, modulation transfer function (MTF) for the 17 moderate resolution bands (M-bands), and horizontal spatial resolution (HSR) for the five imagery bands (I-bands); 2) matrices of band-to-band co-registration (BBR) from the corresponding detectors in all band pairs; and 3) pointing knowledge and stability characteristics that includes scan plane tilt, scan rate and scan start position variations, and thermally induced variations in pointing with respect to orbital position. They have been calibrated and characterized through ground testing under ambient and thermal vacuum conditions, numerical modeling and analysis. This paper summarizes the results, which are in general compliance with specifications, along with anomaly investigations, and describes paths forward for characterizing on-orbit BBR and spatial response, and for improving instrument on-orbit performance in pointing and geolocation.

Lin, Guoqing↗

Heat Transfer Issues in Thin-Film Thermal Radiation Detectors

The Thermal Radiation Group at Virginia Polytechnic Institute and State University has been working closely with scientists and engineers at NASA's Langley Research Center to develop accurate analytical and numerical models suitable for designing next generation thin-film thermal radiation detectors for earth radiation budget measurement applications. The current study provides an analytical model of the notional thermal radiation detector that takes into account thermal transport phenomena, such as the contact resistance between the layers of the detector, and is suitable for use in parameter estimation. It was found that the responsivity of the detector can increase significantly due to the presence of contact resistance between the layers of the detector. Also presented is the effect of doping the thermal impedance layer of the detector with conducting particles in order to electrically link the two junctions of the detector. It was found that the responsivity and the time response of the doped detector decrease significantly in this case. The corresponding decrease of the electrical resistance of the doped thermal impedance layer is not sufficient to significantly improve the electrical performance of the detector. Finally, the "roughness effect" is shown to be unable to explain the decrease in the thermal conductivity often reported for thin-film layers.

Barry, Mamadou Y.↗

The pyroelectric properties of TGS for application in infrared detection

The pyroelectric property of triglycine sulfate and its application in the detection of infrared radiation are described. The detectivities of pyroelectric detectors and other types of infrared detectors are compared. The thermal response of a pyroelectric detector element and the resulting electrical response are derived in terms of the material parameters. The noise sources which limit the sensitivity of pyroelectric detectors are described, and the noise equivalent power for each noise source is given as a function of frequency and detector area.

Kroes, R. L.↗

Measurements of electron detection efficiencies in solid state detectors.

Detailed laboratory measurement of the electron response of solid state detectors as a function of incident electron energy, detector depletion depth, and energy-loss discriminator threshold. These response functions were determined by exposing totally depleted silicon surface barrier detectors with depletion depths between 50 and 1000 microns to the beam from a magnetic beta-ray spectrometer. The data were extended to 5000 microns depletion depth using the results of previously published Monte Carlo electron calculations. When the electron counting efficiency of a given detector is plotted as a function of energy-loss threshold for various incident energies, the efficiency curves are bounded by a smooth envelope which represents the upper limit to the detection efficiency. These upper limit curves, which scale in a simple way, make it possible to easily estimate the electron sensitivity of solid-state detector systems.

Lupton, J. E.↗

Proton calibration of low energy neutron detectors containing (6)LiF

The purpose of the present calibrations is to measure the proton response of the detectors with accelerated beams having energies within the region of maximum intensities in the trapped proton spectrum encountered in near-Earth orbit. This response is compared with the responses of the spaceflight detectors when related to proton exposures. All of the spaceflight neutron measurements have been accompanied by TLD absorbed doses measurements in close proximity within the spacecraft. For purposes of comparison, the spaceflight TLD doses are assumed to be proton doses.

Benton, E. V.↗

Code CUGEL: A code to unfold Ge(Li) spectrometer polyenergetic gamma photon experimental distributions

A FORTRAN code was developed for the Univac 1108 digital computer to unfold lithium-drifted germanium semiconductor spectrometers, polyenergetic gamma photon experimental distributions. It was designed to analyze the combination continuous and monoenergetic gamma radiation field of radioisotope volumetric sources. The code generates the detector system response matrix function and applies it to monoenergetic spectral components discretely and to the continuum iteratively. It corrects for system drift, source decay, background, and detection efficiency. Results are presented in digital form for differential and integrated photon number and energy distributions, and for exposure dose.

Steyn, J. J.↗