Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector control systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗

Technologies to Enable the Next Great Observatory

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is one of four mission concepts being studied by NASA for the 2020 Decadal Survey in Astronomy and Astrophysics. LUVOIR will be capable of a broad range of science, including: direct imaging and characterization of a wide range of exoplanets and the search for biosignatures on Earth-like planets around sun-like stars; studying galaxy formation and evolution; investigating star and planet formation; and remote sensing of bodies within the Solar System. Enabling a mission as ambitious as LUVOIR requires an array of technologies, such as ultra-stable structures and optics, precision metrology and wavefront sensing, high-contrast imaging techniques, large-format detectors with very low noise, and high-throughput ultraviolet instrumentation. Critically, a systems-level approach must be taken to developing these technologies, guided by architecture studies to place each technology in the appropriate system context.In this poster, we describe LUVOIR's technology needs, as well as current efforts that are actively developing these technologies. We will discuss recent advancements in: measuring picometer-level displacements of optical and structural elements; sub-milli-kelvin thermal sensing and control; non-contact vibration isolation for pointing and dynamic stability; coronagraph design for achieving 10-10 contrast on a segmented system; high-speed metrology for optical system alignment; low-order and out-of-band wavefront sensing for maintaining high-contrast images; low-noise detectors across the ultraviolet, optical, and near infrared bands; broadband coatings with high-reflectivity below Ly. We will also describe a systems approach to coordinating the development of these technologies to achieve the necessary maturity for a LUVOIR mission start in the next decade.

space telescopes↗

Instrumentation in astronomy VII; Proceedings of the Meeting, Tucson, AZ, Feb. 13-17, 1990

The topics discussed include IR detectors and instrumentation, detectors, other instrumentation, optical instrumentation, and space instrumentation. Papers are presented on the IR spectrometer/imager for the ESO VLT, the fiber-coupled high-resolution IR array spectrometer for the Kuiper Airborne Observatory, the Balloon-Borne Infrared Telescope for FIR spectroscopy, and a simple transputer-based CCD camera controller. Attention is given to CCD guidance system for William Herschel Telescope, the New Technology Telescope control/acquisition system as a prototype for the VLT, a control system for spincasting 8-m borosilicate honeycomb mirrors, echelle spectrographs for 8-m class telescopes, and fiber spectroscopy at Palomar Observatory. Other papers are on the Kitt Peak National Observatory fiber actuator device, a two-star photoelectric photometer, an ultrahigh-resolution XUV spectroheliograph, an optical monitor for X-ray satellites, and large-format electrographic and array detectors for a space Schmidt imaging telescope.

Crawford, David L.↗

Cool Star Binaries with ALEXIS

We proposed to search for high-temperature, flare-produced Fe XXIII line emission from active cool star binary systems using the ALEXIS all-sky survey. Previous X-ray transient searches with ARIEL V and HEAO-1, and subsequent shorter duration monitoring with the GINGA and EXOSAT satellites demonstrated that active binaries can produce large (EM approximately equals 10(exp 55-56/cu cm) X-ray flares lasting several hours or longer. Hot plasma from these flares at temperatures of 10(exp 7)K or more should produce Fe XXIII line emission at lambda = 132.8 A, very near the peak response of ALEXIS telescopes 1A and 2A. Our primary goals were to estimate flare frequency for the largest flares in the active binary systems, and, if the data permitted, to derive a distribution of flare energy vs. frequency for the sample as a whole. After a long delay due to the initial problems with the ALEXIS attitude control, the heroic efforts on the part of the ALEXIS satellite team enabled us to carry out this survey. However, the combination of the higher than expected and variable background in the ALEXIS detectors, and the lower throughput of the ALEXIS telescopes resulted in no convincing detections of large flares from the active binary systems. In addition, vignetting-corrected effective exposure times from the ALEXIS aspect solution were not available prior to the end of this contract; therefore, we were unable to convert upper limits measured in ALEXIS counts to the equivalent L(sub EUV).

Stern, Robert A.↗

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

When we last reported, our new microcalorimeter system was being prepared for delivery and permanent installation at the NIST EBIT. This occurred in June 2003 and check-out with the internal calibration source and EBIT plasma x-rays took place over the next several months during which time we modified several component parts to improve the performance. These changes included: 1) A redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) The microcalorimeter electronic circuit has been significantly improved to ensure long-term stability for the lengthy upcoming runs of the EBIT. Both the preamplifier feedback resistors were changed and the first stage of the preamplifier redesigned. Several photos of the new system are shown in slides 3 and 4. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours in our earlier system) and it will hold a temperature of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. The first x-ray spectra of the new calibration source made with the 4-element detector array is shown. An example of the temperature control capabilities of the ADR for a 23 hour interval is shown. The horizontal line shows the temperature stability (about +/- 3 micro kelvin). There are a few short-lived heating excursions caused by technical staff working on the EBIT machine simultaneously. During actual experimental runs these are absent. This temporal profile was interrupted to test additional components of the system; otherwise, the temperature controlling would have continued for another 24 hours.

Silver, Eric↗

Development of Biomorphic Flyers

Biomorphic flyers have recently been demonstrated that utilize the approach described earlier in "Bio-Inspired Engineering of Exploration Systems" (NPO-21142), NASA Tech Briefs, Vol. 27, No. 5 (May 2003), page 54, to distill the principles found in successful, nature-tested mechanisms of flight control. Two types of flyers are being built, corresponding to the imaging and shepherding flyers for a biomorphic mission described earlier in "Cooperative Lander- Surface/Aerial Microflyer Missions for Mars Exploration" (NPO-30286), NASA Tech Briefs, Vol. 28, No. 5 (May 2004), page 36. The common features of these two types of flyers are that both are delta-wing airplanes incorporating bio-inspired capabilities of control, navigation, and visual search for exploration. The delta-wing design is robust to approx.40 G axial load and offers ease of stowing and packaging. The prototype that we have built recently is shown in the figure. Such levels of miniaturization and autonomous navigation are essential to enable biomorphic microflyers (<1 kg) that can be deployed in large numbers for distributed measurements and exploration of difficult terrain while avoiding hazards. Individual bio-inspired sensors that will be incorporated in a biomorphic flyer have been demonstrated recently. These sensors include a robust, lightweight (~6 g), and low-power (~40 mW) horizon sensor for flight stabilization. It integrates successfully the principles of the dragonfly ocelli. The ocelli are small eyes on the dorsal and forward regions of the heads of many insects. The ocelli are distinct from the compound eyes that are most commonly associated with insect vision. In many insects, the ocelli are little more than single-point detectors of short-wavelength light and behavioral responses to ocelli stimuli are hard to observe. The notable exception is found in dragonflies, where flight control is notably degraded by any interference with the ocellar system. Our team has discovered recently that the ocelli are a dedicated horizon sensor, with substantial optical processing and multiple spectral sensitivity. To our knowledge, this is the world s first demonstrated use of a "biomorphic ocellus" as a flight-stabilization system. The advantage of the ocelli over a similarly sized system of rate gyroscopes is that both attitude control and rate damping can be realized in one device. A full inertial unit and significant processing would otherwise be required to achieve the same effect. As a prelude to full autonomy, substantial stability augmentation is provided to the pilot at very low cost in terms of space, power, and mass. The sensor is about 40 times lighter than a comparable inertial attitude reference system. Other significant features of the biomorphic flyer shown in the figure include its ability to fly at high angles of attack ~30 and a deep wing chord which allows scaling to small size and low Reynold s number situations. Furthermore, the placement of the propulsion system near the center of gravity allows continued control authority at low speeds. These attributes make such biomorphic flyers uniquely suited to planetary and terrestrial exploration where small size and autonomous airborne operation are required.

Thakoor, Sarita↗

Autonomous control of roving vehicles for unmanned exploration of the planets

The guidance of an autonomous rover for unmanned planetary exploration using a short range (0.5 - 3.0 meter) hazard detection system was studied. Experimental data derived from a one laser/one detector system were used in the development of improved algorithms for the guidance of the rover. The new algorithms which account for the dynamic characteristics of the Rensselaer rover can be applied to other rover concepts provided that the rover dynamic parameters are modified appropriately. The new algorithms will also be applicable to the advanced scanning system. The design of an elevation scanning laser/multisensor hazard detection system was completed. All mechanical and electronic hardware components with the exception of the sensor optics and electronic components were constructed and tested.

Yerazunis, S. W.↗

Analysis of a spatial tracking subsystem for optical communications

Spatial tracking plays a very critical role in designing optical communication systems because of the small angular beamwidth associated with the optical signal. One possible solution for spatial tracking is to use a nutating mirror which dithers the incoming beam at a rate much higher than the mechanical disturbances. A power detector then senses the change in detected power as the signal is reflected off the nutating mirror. This signal is then correlated with the nutator driver signals to obtain estimates of the azimuth and elevation tracking signals to control the fast scanning mirrors. A theoretical analysis is performed for a spatial tracking system using a nutator disturbed by shot noise and mechanical vibrations. Contributions of shot noise and mechanical vibrations to the total tracking error variance are derived. Given the vibration spectrum and the expected signal power, there exists an optimal amplitude for the nutation which optimizes the receiver performance. The expected performance of a nutator based system is estimated based on the choice of nutation amplitude.

Win, Moe Z.↗

In situ measurement of atomic hydrogen in the upper mesosphere

In situ measurements of H abundance between 73 and 93 km are reported for conditions of winter solstice, magnetic quiet, and a solar depression angle of 12 deg. The data were obtained by a rocket-borne instrument using the resonance fluorescence technique. A discharge source emitting photons at 1216 A was an integral part of the instrument. The instrument was radially deployed 80 cm by a boom from the front of the payload in order to avoid the shock created by the gas flow over the front of the payload. An attitude control system oriented the payload so that the gas flow was nearly perpendicular to the plane containing the incident and scattered photons, thus minimizing any correction for Doppler shift. The resonance radiation detector viewed a black backstop in order to minimize background radiation from the hydrogen geocorona; however, the background was not entirely eliminated. The signal-to-noise ratio was improved by summing the data in 1.8-s bins. The observed hydrogen concentration maximized at 85 km at 1.5 + or - 1.1 x 10 to the 8th atoms/cu cm.

Sharp, W. E.↗

Report of the Working Group on Space/Lunar Tradeoffs

The group discussed the advantages and disadvantages of five locations for an optical/infrared array: low-Earth orbit (LEO), Sun-synchronous Earth-orbit, geosynchronous orbit (GEO), Lagrangian points (L4 and L5), and the lunar surface. The factors affecting an array and our assessments of them are given and briefly discussed. In the discussions, two axioms are assumed: (1) Human expansion into space and to the Moon will occur; and (2) The Space Station will be constructed and operational. The major conclusion reached is that baselines of moderate size (greater than 300 m) are best done on the Moon and that large baselines (greater than 10 km) can be done only on the Moon. Three areas needing additional research were identified as follows. (1) Studies are needed on methods to steer long-baseline systems in orbit. This involves learning how to control free-flyers. It is not clear how the difficulty of control varies with orbital elevation. (2) More work is needed on the internal metrology of array systems, both orbital and lunar-surface systems.(3) We need to understand the radiation effects on detectors and electronics and learn how to mitigate them.

Source record↗

A multi-channel coronal spectrophotometer.

We describe a new multi-channel coronal spectrophotometer system, presently being installed at Mees Solar Observatory, Mount Haleakala, Maui. The apparatus is designed to record and interpret intensities from many sections of the visible and near-visible spectral regions simultaneously, with relatively high spatial and temporal resolution. The detector, a thermoelectrically cooled silicon vidicon camera tube, has its central target area divided into a rectangular array of about 100,000 pixels and is read out in a slow-scan (about 2 sec/frame) mode. Instrument functioning is entirely under PDP 11/45 computer control, and interfacing is via the CAMAC system.

Landman, D. A.↗

Motor power factor controller with a reduced voltage starter

A power factor type motor controller is disclosed in which the conventional power factor constant voltage command signal is replaced during a starting interval with a graduated control voltage. This continuation-impart of a pending patent application (Serial No. 199, 765: Three Phase Factor Controller) provides a means for modifying the operation of the system for a motor start-up interval of 5 to 30 second. Using a ramp generators, an initial ramp-like signal replaces a constant power factor signal supplied by a potentiometer. The ramp-like signal is applied to a 15 terminal where it is summed with an operating power factor signal from phase detectors in order to obtain a control signal for ultimately controlling SCR devices. The SCR devices are turned on at an advancing rate with time responsive to the combination signal described rather than simply a function of a ramp-like signal alone.

Nola, F. J.↗

Thermal Vacuum/Balance Test Results of Swift BAT with Loop Heat Pipe Thermal System

The Swift Burst Alert Telescope (BAT) Detector Array is thermally well coupled to eight constant conductance heat pipes (CCHPs) embedded in the Detector Array Plate PAP), and two loop heat pipes (LHPs) transport heat from the CCHPs to a radiator. The CCHPs have ammonia as the working fluid and the LHPs have propylene as the working fluid. Precision heater controllers, which have adjustable set points in flight, are used to control the LHP compensation chamber and Detector Array xA1 ASIC temperatures. The radiator has AZ-Tek's AZW-LA-II low solar absorptance white paint as the thermal coating, and is located on the anti-sun side of the spacecraft. A thermal balance (T/B) test on the BAT was successfully completed. It validated that the thermal design satisfies the temperature requirements of the BAT in the flight thermal environments. Instrument level and observatory level thermal vacuum (TN) cycling tests of the BAT Detector Array by using the LHP thermal system were successfully completed. This paper presents the results of the T/B test and T N cycling tests.

Choi, Michael K.↗

Hydrogen detection study

The effectiveness was assessed of a hydrogen (H2) detection concept for regenerative environmental control life support systems (EC/LSS). The concept evaluated was that utilized for the electrochemical depolarized concentrator (EDC) design, constructed, and tested for the EC/LSS space station prototype program. The EDC contains combustible gas detectors (CGDs) which were evaluated with H2. The CGDs were evaluated for linearity, position sensitivity, reproducibility, ambient effects, repeatability, speed of response, recovery time, and interchangeability. The effectiveness of CGDs located within the EDC for sensing H2 leaks at various line replaceable units in the subsystem was determined. The effects of H2 leak rate, H2 concentration of leaking gas and air currents in the vicinity of the EDC were determined. Proposed improvements for the H2 detection concept were documented and alternative H2 detection approaches were identified and analyzed.

Shumar, J. W.↗

The High Energy Astronomy Observatory X-ray Telescope

The High Energy Astronomy Observatory-Mission B (HEAO-B) is a satellite observatory for the purpose of performing a detailed X-ray survey of the celestial sphere. Measurements will be made of stellar radiation in the range 0.2 through 20 keV. The primary viewing requirement is to provide final aspect solution and internal alignment information to correlate an observed X-ray image with the celestial sphere to within one-and-one-half arc seconds. The Observatory consists of the HEAO Spacecraft together with the X-ray Telescope. The Spacecraft provides the required attitude control and determination system, data telemetry system, space solar power system, and interface with the launch vehicle. The X-ray Telescope includes a high resolution mirror assembly, optical bench metering structure, X-ray detectors, detector positioning system, detector electronics and aspect sensing system.

Miller, R.↗

The JPL Field Emission Spectrometer

The Jet Propulsion Laboratory (JPL) Field Emission Spectrometer (FES) was built by Designs and Prototypes based on a set of functional requirements supplied by JPL. The instrument has a spectral resolution of 6 wavenumbers (wn) and can acquire spectra from either the Mid Infrared (3-5 mu m) or the Thermal Infrared (8-12 pm) depending on whether the InSb or HgCdTe detector is installed respectively. The instrument consists of an optical head system unit and battery. The optical head which is tripod mounted includes the interferometer and detector dewar assembly. Wavelength calibration of the interferometer is achieved using a Helium-Neon laser diode. The dewar needs replenishing with liquid Nitrogen approximately every four hours. The system unit includes the controls for operation and the computer used for acquiring viewing and processing spectra. Radiometric calibration is achieved with an external temperature-controlled blackbody that mounts on the fore-optics of the instrument. The blackbody can be set at 5 C increments between 10 and 55 C. The instrument is compact and weighs about 33 kg. Both the wavelength calibration and radiometric calibration of the instrument have been evaluated. The wavelength calibration was checked by comparison of the position of water features in a spectrum of the sky with their position in the output from a high resolution atmospheric model. The results indicatethat the features in the sky spectrum are within 6-8 wn of their position ill the model spectrum. The radiometric calibration was checked by first calibrating the instrument using the external blackbody supplied with the instrument and then measuring the radiance from another external blackbody at a series of temperatures. The temperatures of these radiance spectra were then recovered by inventing Planck's law and the recovered temperatures compared lo the measured blackbody temperature. These results indicate that radiometric calibration is good to 0.5 C over the range of temperatures 10 to 55 C. The results also indicate that the instrument drifts slowly over time and should be recalibrated every 20 to 30 minutes in the field to ensure good radiometric fidelity. The instrument has now been extensively tested in the field in the United States and Australia. These in situ field measurements are being used to validate emissivity spectra recovered from the Thermal Infrared Multispectral Scanner (TIMS) and also the Australian CO2 Laser. The availability of in situ measurements is proving crucial to validation of the spectra derived from the airborne instruments since many natural surfaces cannot be easily transported back to the laboratory.

Hook, Simon J.↗

NASA Tech Briefs, February 2011

Topics covered include: Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly; Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection; Photocatalytic Active Radiation Measurements and Use; Computer Generated Hologram System for Wavefront Measurement System Calibration; Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System; SpaceCube 2.0: An Advanced Hybrid Onboard Data Processor; CMOS Imager Has Better Cross-Talk and Full-Well Performance; High-Performance Wireless Telemetry; Telemetry-Based Ranging; JWST Wavefront Control Toolbox; Java Image I/O for VICAR, PDS, and ISIS; X-Band Acquisition Aid Software; Antimicrobial-Coated Granules for Disinfecting Water; Range 7 Scanner Integration with PaR Robot Scanning System; Methods of Antimicrobial Coating of Diverse Materials; High-Operating-Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength; A Model of Reduced Kinetics for Alkane Oxidation Using Constituents and Species for N-Heptane; Thermally Conductive Tape Based on Carbon Nanotube Arrays; Two Catalysts for Selective Oxidation of Contaminant Gases; Nanoscale Metal Oxide Semiconductors for Gas Sensing; Lightweight, Ultra-High-Temperature, CMC-Lined Carbon/Carbon Structures; Sample Acquisition and Handling System from a Remote Platform; Improved Rare-Earth Emitter Hollow Cathode; High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement; Cryogenic Scan Mechanism for Fourier Transform Spectrometer; Piezoelectric Rotary Tube Motor; Thermoelectric Energy Conversion Technology for High-Altitude Airships; Combustor Computations for CO2-Neutral Aviation; Use of Dynamic Distortion to Predict and Alleviate Loss of Control; Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards; and A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks.

Source record↗

Closed Environment Air Revitalization System Based on Metal Organic Framework Adsorbents

This project utilized a systems engineering methodology to develop a vacuum swing adsorption system with full Labview automated control. The project was successful and provided students with an introduction to systems engineering and air revitalization. Specifically, two stainless steel adsorption beds were custom designed and manufactured and a sequence of computer controlled valves were used to deliver CO 2 laden, humid air, to the adsorbent where the CO 2 was removed from the air stream. Runs were completed using 13X zeolite and bed timing and switching was controlled by the computer based on the data output of a CO 2 detector. Adsorption runs using the MOF have not been completed upon the writing of this report; however, the MOF material is currently being synthesized and the runs will be completed upon receipt of the material. A follow up meeting with NASA has been tentatively planned to discuss the output of these experiments. Consistent with systems engineering practice, an end of project assessment of the class was conducted with the students and several items were realized. Specifically, the short period of performance of this grant makes it necessary to maintain a narrowly focused scope on the project such that multiple experiments after systems development (T&E) need to be limited to ensure timely completion of the proposed tasks. Also, procurement of parts may need to be moved forward in time to allow for delivery delays, and it may be necessary to request SDR, PDR, and CDR dates from NASA that are ahead of the NASA anticipated schedule. These types of lessons provided valuable to both the PI and the students and ultimately illustrate the necessity of proper systems engineering schedule risk assessment. The class met the objectives of the project and provided an introduction to systems engineering to undergraduate students. As a metric of that success, the lead engineer of the undergraduate design team acquired a job with an aerospace defense contractor, which he attributed to his knowledge of systems engineering concepts that were acquired via the X-Hab class.

T. Grant Glover↗